PRODUCT MODEL NUMBERS
VENTING REQUIREMENTS
JXP5032W
●
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
32" (81.3 cm) Wall-Mount Perimetric Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274314A
10/26/09
ELECTRICAL REQUIREMENTS
This range hood is factory set for 8" (20.3 cm) round venting through the roof
or wall. An 8" (20.3 cm) round vent system is needed for installation (not
included). To vent through the wall, a 90° elbow is needed.
This range hood can also be set for 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular
venting out the back using the 3¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper
(supplied). See the “Connect Vent System” section for details for installing the
damper and vent system.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure
and air turbulence that greatly reduce performance.
NOTE: This hood can be installed without the chimney covers when venting
directly out the back or when using the recirculation kit with the top grille cap.
See “For non-vented (recirculating) installations without vent only:” section.
For non-vented (recirculating) installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood
can be used in the non-vented (recirculating) version, fitting a charcoal filter
and the deflector for installations using vent covers or fitting a charcoal filter
and top grille cap for installations without the vent covers.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet
(meters) for each vent piece used in the system.
Vent Piece 8" (20.3 cm) Round
45° elbow 2.5 ft
(0.8 m)
90° elbow 5.0 ft
(1.5 m)
Maximum equivalent vent length is 35 ft (10.7 m).
Example Vent System
The following example falls within the maximum vent length of 35 ft
(10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m)
1 - wall cap = 0.0 ft (0.0 m)
8 ft (2.4 m) straight = 8.0 ft (2.4 m)
System length = 13 ft (3.9 m)
LOCATION REQUIREMENTS
IMPORTANT: Observe all governing codes and ordinances. Have a
qualified technician install the range hood. It is the installer's
responsibility to comply with installation clearances specified on the
model/serial rating plate. The model/serial rating plate is located behind
the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as
windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical Requirements”
section.
The canopy hood is factory set for venting through the roof or wall. For
non-vented (recirculating) Installation see “Non-vented (recirculating)
Installations” in “Prepare Location” section. Recirculation Kit Part
Number W10272062 is available from your dealer or an authorized parts
distributor.
All openings in ceiling and wall where canopy hood will be installed must
be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured
Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly
the Federal Standard for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home Sites,
Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or
with local codes.
Page 1 of 2
Roof Venting Wall Venting Rear Venting
A
B
B
B
A
A
A. Roof cap
B. 8" (20.3 cm)
round vent
Non-vented
(recirculating) with
vent covers
A. Wall cap
B. 8" (20.3 cm)
round vent
without vent covers
A. Wall cap
B. 3¼" x 10" (8.3 x
25.4 cm) vent
Non-vented
(recirculating)
A
B
A
90 elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Wall cap
A. Deflector
B. 8" (20.3 cm)
round vent
A. Top grille cap
PRODUCT DIMENSIONS
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10274314A
10/26/09
Page 2 of 2
*For non-vented (recirculating) installations
IMPORTANT:
Minimum distance "X": 18" (45.7 cm) from electric cooking surface.
Minimum distance "X": 22" (55.9 cm) from gas cooking surfaces.
Suggested maximum distance "X": 24" (61.0 cm)
For vented installations, the chimneys can be adjusted for ceilings
between 7’ 11" (2.4 m) and 9' 3" (2.8 m).
For non-vented (recirculating) installations, the chimneys can be
adjusted for ceilings between 7’ 11" (2.4 m) and 9' 7" (2.9 m).
*NOTE: The range hood chimneys are adjustable and designed to meet
varying ceiling or soffit heights depending on the distance “X” between
the bottom of the range hood and the cooking surface. For higher
ceilings, a Chimney Extension Kit Part Number W10272075 (stainless)
or W10272074 (white) is available from your dealer or an authorized
parts distributor. The chimney extension replaces the upper chimney
shipped with the range hood.
10¹⁄₂"
(26.7 cm)
13"
(33.0 cm)
10" (25.4 cm) min.
13" (33.0 cm) max.
9¹⁄₂" (24.1 cm)
2" (5.1 cm) min.
9" (22.9 cm) min.*
(38.7 cm)
32"
(81.3 cm)
*For non-vented (recirculating) installations
**For vented installations
*43³⁄₄" (111.1 cm) min.
56³⁄₄" (144.1 cm) max.
**43³⁄₄" (111.1 cm) min.
53" (134.6 cm) max.
15¹⁄₄"
26"
(66.0 cm)
20¹⁄₂"
(52.1 cm)
10" (25.4 cm) min.
13" (33.0 cm) max.
Side
cabinet
bottom of
canopy
to cooking
surface
17" (43.2 cm)*
32" (81.3 cm)
"X"
Vent and power
supply cable
entry location
Side
cabinet
Centerline