Jenn-Air UXT5230ADB, UXT5230ADQ, UXT5230ADS, UXT5230ADW, UXT5236ADB Installation Guide

...
RANGE HOOD
Model Number: UXT5230AD" UXT5430AD*
UXTS236AD" UXT5436AD*
Manufacturer Number: MK5500 MK5800 Size: 30" & 36" 30" & 36"
INSTALLATION
GUIDE
TABLE OF CONTENTS
Mounting Heights ......................... 2
Ductmg .................... 3-7-9
Installation ........ 5-6
=JENN-AIR
Form No A/04/03 Part No IMKS558-0303A @2003 Maytag Appliances Sales Co Litho U S A
MODELS: UXT5230AD" UXT5236AD ° UXT5430AD" UXT5436AD"
Installation
Theinstallationinthismanualisintendedforqualifiedinstallers,servicetechniciansorpersons
withs[rnilarqualifiedbackground,DONOTattempttoinstallthisapplianceyourself.Injurycould resultfrominstaltingtheunitduetolackofappropriateelectricalandtechnicalbackground.
Allelectricalwiringmustbepropedyinstalled,insulatedandgrounded.Overlyaccumulated greaseinoldductworkshouldbecleanedoutor ductworkshouldbereplacedifnecessaryto
avoidthepossibilityofa greasefire.Checkalljoints onductworktoinsureproperconnection andalljointashouldbeproperlytaped,
Pleasecheckfor latestspecificationrevisionsbeforeanycustomworkor cutouts.
INSTALLATION
MOUNTINGHEIGHTS
9B"
36,,
DUCTING Aminimumof6"roundor3-1/4"x10"rectangular
ductmustbeusedtomaintainmaximumairflow
efficiency.
Alwaysuserigid-type metalductsonly.
Flexibleductscouldrestrict air flow by up to 50%,
Alsousecalculation(onright)to compute total
availableductrun whenusingelbows,transitions
andcaps.
ALWAYS,whenpossible,reducethenumberof
transitionsandturns.If longductrunis required,
increaseductsizefrom6"to 7or8".Ifa reducer isused,installa longreducerinsteadofapancake
reducer.Reduceductsizeasfarawayfromopen- ingaspossible.
if turnsortransitionsarerequired: Installasfar awayfromopeningandasfar apart,between2,aspossible.
Minimummountingheightbetweenrangetop tohoodbottomsh_ld benolessthan24",
Maximummountingheightshouldbenohigh- erthan32".
itisimportanttoinstallthehoodatthe propermountingheight.Hoodsmountedtoo lowcouldresultinheatdamageandfire hazard',whilehoodsmountedtoohighwillbe hardtoreachandwillloseperformanceand efficiency.
if available,alsorefer to range manufacturer's heightclearancerequirementsandrecom- mendedhoodmountingheightaboverange.
DuctRunCalculation: Maximumrun 6"or3-1/4"x 10" duct
Deduct: each90Elbowused 15 FT
each45elbowused 9 FT each5"to 3/14x 10"
transitionused 1 FT each3/14xlO"to 6"
each3/14x10"to 6" _ansitionused 5 FT
SideVial]Capw/damper 30FT
RoofCap 30FT
_- I mofcap,2xgOelbows,1 45elbowused:
=30'÷30'÷ 9' =69'used,31"availableforstraightductruns.
IOOR"
INSTALLATION
DUCTING
_rjr_lmlJTl.,1.-j _ iiL_JellI I:| =11-"P.lrl.*l ;_elB
NEVERexhaustairorterminateductworkintospacesbetweenwalls,crawlspaces,ceiling,atticsor
garages.Allexhaustmustbeductedtotheoutside. UseMetalductwerkonly, Fastenallconnectionswithsheetmetalscrewsandtapealljointsw/certifiedSilverTapeorDuctTape.
SomeDuctingOptions:
;idewallcap
wl gravitydarnpm
J
¢.w ] u-
r :l
i ]
i i
J " side cap
SofFaorcrawlspace
w/9 ( darnpe_
SPECIFICATIONS
155/8"
INSTALLATION
-30"or 36"-
I ': 1e
I I
CIL
3 114"
ll_ III
V
6"
30" or 36"
1/2" Elec.K.O,
INSTALLATION
MOUNTINGTHERANGEHOOD
ELECTRICAL
AllElectricalworkmustbyperformedbyqualifiedelectricianorpersonwithsimilartechnical knowhowandbackground.
Forpersonalsafety,removehousefuseoropencircuitbreakerbeforebeginninginstallation. Donotuseextensioncordoradapterplugwiththisappliance.
FollowNationalelectricalcodesorprevailinglocalcodesandordinances. ElectricalSupply:
Thisappliancerequiresa 120V60Hzelectricalsupply,connectedtoanindividual,properlygrounded
branchcircuit,protectedbya 15or20amperecircuitbreakerortimedelayfuse.Wiringmustbe2
wirew/ground.PleasealsoreferElectricalDiagramlabeledonproduct.
CableLock: Acablelockingconnector(notsupplied)mightalsorequiredbylocalcodes.Checkwithlocal
requirementsandcodes,purchaseandinstallappropriateconnectorifnecessary.
INSTALLATION D
MOUNTINGTHE RANGEHOOD
1. Thisrangehoodismountedundera kitchencabinetunit.
2. Selectpreferredductlocationonrearor
topofunit.Forductlessconversion,no
ductingisrequired.
3. Begininstallationbytemporarilyremoving thediffuserandfilterpanels.
4. Temporarilypositiontherangehoodin thedesiredmountingIocatien. Measureandmarkthemountingholes,
ductandelectricalaccesslocationswith a pencil.
5. Drill/cutoutthe requiredopeningsfor
ductandelectricalaccess;makesurethe ductopeningislargeenoughtoapply
ducttape.
G. Fastenmountingscrewsonto
cabinetasmarked,donottighten, leavinghalflengthofscrewsexposed.
7. installelectrical.
8. Hanghoodontoscrewsthroughkey
holes,andtighten.
9. installductworkandduct-tape.
10.Reinst_l[thedifuserpanels.
11.Poweruphoodandcheckforleaks
aroundduct-tape.
duct/silver tape
INSTALLATION
CONVERTIBLEOPTIONS
This range hoodis equippedwith the optionof a 6" vertical discharge,3 1/4"x10" vertical discharge, or 3 114"x10"rear discharge.Additionalaccessoriesareprovidedto convertto eitherof the above
dischargemethods.
ConvertibleOptions
Verticaldischarge 6" round Verticaldischarge 3 114"x10"
Horizontalrear discharge 3 1/4"x10"
3 1/4"x10" Vertical Discharge
ConvertibleAccesodes Roundto rectangulartransitionadaptor
Rectangularto round transition adaptor(pre-mounted)
Gasket(pre-mounted)
Rectangularrearcap(preomounted) 3 114"x10"starting collar
1, Removepre-mounted6"transitionadaptororduct opening.Leaveattachedgasketinitsoriginalplace,
/
3.Mountthe 3-1/4"x10"starlingcollarontop of
transitionpiecewithremainingscrews.
2, Placerectangulartransitionadaptorasshownover gasketandbyfirst installing4 screwsonhalfround
section.
CONVERTIBLEOPTIONS
3 1/4"x10" Rear Discharge
INSTALLATION
1.At rearofrange hood,removeal!screwsonpre- mountedrearrectangularcapandremovecap.
_3
/
3.Mountrectangulartransitionpieceat openingwith
gasketas shown.
2. Removetoppre-mountedtransitionpiece.Leave attachedgasketinitsoriginalplace.
! )
4.Mountrectangularcap(previouslyremoved)ontop
oftransitionadaptor.
5,Mountstartingcollar(provided)atreardischarge openingwithgasket,
INSTALLATION
DUCTLESSCONVERSION
Ductlessconversionisintendedforapplicationswhereanexhaustductworkisnotpossibletobe
installed.Whenconverted,thehoodfunctionsasa "purifying"hoodratherthananexhausthood, FumesandexhaustfromconkingaredrawnandfilteredbyasetofoptionalCarbonFilters.Theair isthenpurifiedandre-circulatedbackwithinthehome.
WerecommendtoALWAYSexhaustairoutsideofthehomebyemployingexistingorinstalling
newductwork,ifpossible.ThehoodismosteffectiveandefficientasanExhaustunit.Onlywhen
theexhaustoptionisnotpossibleshouldyourecoursetoconvertingthehoodintoa"purifying"unit.
Whenconvertedtobea"purifying"unit,a CarbonFiltersKitisrequired.Orderaccordingto itsPart
numberbelow.ThestandardMetalFiltersareintendedtocaptureresiduefromcookingandthe optionalCarbonFiltershelptopurifyfumesexhaustedfromcookingforre-circulation.
CarbonFilters(Required)
1.PurchaseductlessCarbonFiltersKitasfollow:
HoodModel: partNo. Filtersin pkg.
I UXTS230AD* HCFLTUXT3O 2
UXT5236AD* HCFLTUXT36 3
UXT5430AD* HCFLTUXT30 2
HCFLTUXT36 3
2.Theductlessconversionhousingmustbe installedpriortoinstallationoftherange
hood,
3.Removethediffuserpanelsonthehood.
4,Clipcarbonfilterontobracketof
diffuserpanels,
5,Re-instafldiffuserpanels.
6.CarbonFiltersmustbereplacedafter every120hoursofuse(orapproximately
every2to3 monthsbasedontheaverage
of1-2hrs.ofdailyconkingtime).
7. Referinstallationmanualprovidedwith
ductlesscarbonfilterskit,