www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Downdraft Electric Grill-Range Ovens:
S136, S136W, S156, S156W, S176 and S176W
29 15/16"
26 3/8"
• Dimensions (Actual Size) •
Width:
29 15/16"
Depth:
26 3/8"
Height:
Door swing:
Height at full leg adjustment:
Height at 0" leg adjustment:
• Additional Information •
• Units can be installed as a Freestanding unit or
Slide-In unit. Slide-in installation does NOT allow for
use of a backsplash or side panels. If either is desired,
use the free-standing cutout and instructions.
between the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet. 24" minimum
when bottom of wood or metal cabinet is protected by
not less than 1/4" flame retardant millboard covered
with not less than no. 28 MSG sheet steel, 0.015"
stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage
is to be provided, the hazard can be reduced by
installing a range hood that projects horizontally a
minimum of 5" beyond the bottom of the cabinets.
• Range complies with U.L. requirements for 1"
clearance from the range to adjacent vertical side walls
and 7/8" from rear wall. Abnormal surface unit
operation could result in possible scorching of vertical
walls and pose potential fire hazard. Therefore, a 6"
minimum spacing is recommended.
• For Free-standing installations the cutout opening
width is 30 1/8" ± 1/16" minimum. The height of the
countertop is 36" and countertop depth is 25". The
cooktop does NOT need to be notched for
Free-standing installations.
• See page 2 for Slide-in installation specifications
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
If the countertop overhangs the cabinet 1/2"
to 1" the overall cutout depth is 22 7/8".
If the countertop overhangs the cabinet 1" to
1 3/4" the overall cutout depth is 23 3/16".
36"
countertop height
rear countertop opening
1 5/8" Maximum
21 1/8" from rear
Cabinet opening and
from notch edge to
notch edge
cutout to notch
(cabinet face)
29 7/8"
Slide-in/Drop-in instalation
29 3/8" countertop
opening
25" from top of
countertop to top of
under range panel
Cutout opening
(not to scale)
1/4"
• There MUST be 25" clear between the top of countertop and the top of under range panel.
• The appliance rests on the floor, so there CAN NOT be any cabinetry behind the under
range panel (shaded area) and toe kick.
• The under range panel and toe kick MUST be supplied by the builder.
• The under range panel (shaded area) must be removable for inspection and service.
Avoid attaching mounting hardware to adjacent cabinets, it will interfere with range removal.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
8 3/4"
8"2"
14"
Additional duct needed when venting left or right:
Make a cutout in the cabinet
floor of EITHER the left or the
right cabinet as shown by the
shaded areas
(1) 5" to 3 1/4" x 10" transition (P/N A453).
(2) Wood spacers (right side only) 1 1/2" thick x 9" long.
Unit is rated at a maximum of 60 feet of straight duct, 300CFM of
"make-up" is required. The blower has 2 range settings; Low range
is used when equivalent duct length is up to 30 feet and high range
is used when equivalent duct length is between 31 and 60 feet.
1. Use 6" diameter round or 3 1/4" x 10" rectangular only, except
for equivalent duct lengths of 10 feet or less that vent straight out
the back of the cooktop and directly through the wall. Equivalent
duct lengths of 10 feet or less can use 5" round duct. A transition
from 5" round duct is necessary when connecting to 6" round or
3 1/4" x 10" duct.
2. Do not use 5" elbows except in a 5" system. Instead use a 5" to
6" transition followed by a 6" elbow, or a 5" to 3 1/4" x 10" elbow
transition.
3. Use quality metal duct of at least 26 gauge galvanized or 24 gauge
aluminum. Inferior quality pipe fittings can cause up to twice the
restriction and is a poor value. 6" diameter PVC sewer pipe can be
used for under slab installations. Local codes may require a heavier
gauge material or restrict PVC. Check your local codes.
4. Distance between adjacent fittings (elbows, transitions etc.)
should be at least 18". The farther the better. Closer distance
promotes turbulence which reduces airflow.
5. The number of downstream elbows or transitions should be
limited to three. The initial 5" to 6" straight transition, if used, need
not be counted in this number.
6. Handmade crimps are likely to cause restrictions.
7. If an alternate wall or roof cap is used, be certain duct size is not
reduced, and there is a backdraft damper. It is best to use listed caps
to be certain of proper performance.
8. Thermal breaks: In areas of extreme cold weather, it may be
necessary to provide a short length of nonmetallic duct as close to
the wall as possible, to prevent conduction along the metal duct.
9. High altitude installations: It is advisable to reduce allowable duct
run by 20%.
10. In Canada, the installation must conform with local codes.
11. Elbows, wall caps and other fittings are shown below with their
equivalent straight duct length. Each fitting value must be added to
the amount of straight duct length used, to determine overall straight
duct equivalent length (60 feet maximum).
12. When using flexible duct multiply length of flexible duct by 2.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.