Jenn-Air PRO-STYLE JGRP430W, PRO-STYLE JGRP536W, PRO-STYLE JGRP436W, PRO-STYLE JGRP548W, JDRP430W Installation Instructions Manual

...
30" (76.2 CM), 36" (91.4 CM) AND 48" (121.9 CM) PRO-STYLE
®
GAS CONVECTION RANGES
PRODUCT MODEL NUMBERS PRODUCT DIMENSIONS
GAS SUPPLY REQUIREMENTS
A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this range be provided.
Electronic ignition systems operate within wide voltage limits, but proper grounding and polarity are necessary. Check that the outlet provides 120-volt power and is correctly grounded.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10349769A
1/4/11
Type of Gas
Natural Gas:
This range is design-certified by CSA International for use with Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. The model/serial rating plate located under the console on the right-hand side has information on the types of gas that can be used. If the types of gas listed do not include the type of gas available, check with the local gas supplier.
LP Gas conversion:
Conversion must be done by a qualified service technician. No attempt shall be made to convert the range from the gas specified on the
model/serial rating plate for use with a different gas without consulting the serving gas supplier. To convert to LP gas, use the LP gas conversion kit provided with your range and see the “Gas Conversions” section. The parts for this kit are in the literature package supplied with the range.
Gas Supply Line
Provide a gas supply line of ³⁄₄" (1.9 cm) rigid pipe to the range location. A smaller size pipe on longer runs may result in insufficient gas supply. With LP gas, piping or tubing size can be ¹⁄₂" (1.3 cm) minimum. Usually, LP gas suppliers determine the size and materials used in the system. NOTE: Pipe-joint compounds that resist the action of LP gas must be used. Do not use TEFLON
®†
tape.
†®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
JGRP430W JGRP436W JGRP536W JGRP548W
ELECTRICAL REQUIREMENTS
E
E
Page 1 of 2
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSA-A240-latest edition, or with local codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
LOCATION REQUIREMENTS
30" (76.2 cm) models
B
C
D
36" (91.4 cm) models
B
C
A
A
D
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10349769A
1/4/11
Page 2 of 2
CABINET DIMENSIONS
Cabinet opening dimensions shown are for 25" (64 cm) countertop depth, 24" (61 cm) base cabinet depth and 36" (91.4 cm) countertop height. Dimensions must be met in order to ensure a flush fit to back wall.
IMPORTANT: If installing a range hood or hood liner above the range, follow the range hood or hood liner installation instructions for dimensional clearances above the cooktop surface.
*NOTE: Receptacle must be rotated 90° for Canadian installation.
**NOTE: Minimum Clearances
30" (76.2 cm) models: 30" (76.2 cm) minimum clearance between the
top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
36" (91.4 cm) models: 42" (106.7 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
48" (121.9 cm) models: 42" (106.7 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
***NOTE: If back wall is constructed of a combustible material and a
backguard is not installed, a 3" (7.6 cm) minimum clearance is required for all models.
E
*NOTE: When installed in a 24" (61.0 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1⁷⁄₈" (4.8 cm) beyond 24" (61.0 cm) base cabinet.
PRODUCT DIMENSIONS (cont.)
48" (121.9 cm) models
B
C
D
A
C
**
D
B
O***
A
E
F
J
F
I
H
I
G
Gas installation area
J
Electrical installation area*
K
L
N
M
Loading...