www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Over the Range Microwaves:
M438W, M438B and M457B
Kit: MF110
• Dimensions (Actual Size) •
Cabinet opening depth:
Cabinet opening width:
13"
30"
Minimum mounting height from floor: 66" Min.
Minimum mounting height from
cooking surface:
Unit front height:
Unit rear height:
Unit depth:
Unit width:
Distance from unit face to open door:
30"
14 5/8"
16 1/2"
13"
30"
20 1/2
• Additional Information •
• Electrical requirements: Voltage 120, single phase,
60Hz. AC. Ampere 15 or 20. 2 wire with ground circuit
required. Locate outlet box in the cabinet above in the
lower right hand corner, cut a 1 1/2" hole in the back
right hand corner of the cabinet above for the units
cord.
• Wall construction should be a minimum of 2"x4" wood
studding and 3/8" thickness drywall or plaster/both.
• M438W and M438B are designed for use above all
Jenn-Air non-grilling gas and electric ranges and
cooktops (not recommended over grill-ranges or
cooktops with grilling capability unless the range or
cooktop is equipped with downdraft ventilation).
• M457B : is designed for use above all gas and
electric grill-ranges and grill-range cooktops.
• Units can exhaust outside vertically, outside
horizontally or Ductless (with the use of charcoal filter
kit MF110), see page 3 for duct locations.
• Outside ventilation requires hood exhaust duct. The
hood exhaust has been designed to mate with a
standard 3 1/4" x 10" duct. If round is required, a
transition adaptor must be used. Do not use less than
6" round duct.
• Maximum duct length: The total duct length of 3 1/4" x
10" or 6" round duct should not exceed 140 equivalent
feet. When calculating the total duct length add
equivalent lengths of all transitions and adaptors plus
the lengths of all straight duct sections.
• 240 CFM Vertical exhaust (3 1/4" x 10" duct).
• 260 CFM Horizontal exhaust (3 1/4" x 10" duct).
66" Min.
Minimum
mounting
height from
floor
20 1/2
Door Open
height from
(not to scale)
30"
Minimum
mounting
cooking
surface
13"
Exhaust outlet
connects to
3 1/4" X 10" duct
30"
16 1/2"
14 5/8"
Bottom of
unit is angled
13"
30"
See page 2-3 for additional information
Subject to change without notice. This system is designed to
be updated daily if necessary. Dimension Express is not
responsible for use of superseded, voided, or outdated data
sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall
not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
131
BN232 • A131B278C150 • 31469 • 002906 • 114434 • 13804
Wall View (not to scale)
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Equivalent lengths of typical duct adaptors: 3 1/4" x 10" 45° elbow =
5 feet straight. 3 1/4" x 10" 90° elbow = 25 feet straight.
3 1/4" x 10" transition to 6" round = 5 feet straight. 6" round 45° elbow
= 5 feet straight. 6" round 90° elbow = 10 feet straight.
6" round wall cap = 40 feet straight. Roof cap = 24 feet straight.
• M438W : White.
• M438B : Black.
• M457B : Black, high performance exhaust.
Wall View
(not to scale)
Shaded area must be free of obstruction.
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Over the Range Microwaves:
M438W, M438B and M457B
Kit: MF110
Kit:
• MF110 : Charcoal filter used when NOT exhausting to the outside
Grounded
electrical outlet.
Locate power
supply hole in
the rear corner.
30"
16 1/4"
30" minimum
2" min.
from cooking
surface
66"
minimum
from floor
Range (or Cooktop) below
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or
outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00.
Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 •
notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory •
it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am •
Sheets for each project, as opposed to the problems, time, costs, and risks
associated with reusing old Data Sheets.
BN232 • A131B278C150 • 31469 • 002906 • 114434 • 13804
278