www.dexpress.com DIMENSION EXPRESS Fax on Demand (775) 833-3600
|
|
This Data Sheet Includes Information On |
|
|
|
Jenn-Air |
|
• |
Product Model Number (s): |
• |
|
|
|
Over the Range Microwaves: |
|
|
|
M438W, M438B and M457B |
|
|
|
Kit: MF110 |
|
• |
Dimensions (Actual Size) |
• |
|
|
|
Cabinet opening depth: 13" |
|
|
|
Cabinet opening width: 30" |
|
|
|
Minimum mounting height from floor: 66" Min. |
|
|
|
Minimum mounting height from |
|
|
|
cooking surface: 30" |
|
|
|
Unit front height: |
14 5/8" |
|
|
Unit rear height: |
16 1/2" |
|
|
Unit depth: |
13" |
|
|
Unit width: |
30" |
|
|
Distance from unit face to open door: |
20 1/2 |
|
• |
Additional Information |
• |
•Electrical requirements: Voltage 120, single phase, 60Hz. AC. Ampere 15 or 20. 2 wire with ground circuit required. Locate outlet box in the cabinet above in the lower right hand corner, cut a 1 1/2" hole in the back right hand corner of the cabinet above for the units cord.
•Wall construction should be a minimum of 2"x4" wood studding and 3/8" thickness drywall or plaster/both.
•M438W and M438B are designed for use above all Jenn-Air non-grilling gas and electric ranges and cooktops (not recommended over grill-ranges or cooktops with grilling capability unless the range or cooktop is equipped with downdraft ventilation).
•M457B : is designed for use above all gas and electric grill-ranges and grill-range cooktops.
•Units can exhaust outside vertically, outside horizontally or Ductless (with the use of charcoal filter kit MF110), see page 3 for duct locations.
•Outside ventilation requires hood exhaust duct. The hood exhaust has been designed to mate with a standard 3 1/4" x 10" duct. If round is required, a transition adaptor must be used. Do not use less than 6" round duct.
•Maximum duct length: The total duct length of 3 1/4" x 10" or 6" round duct should not exceed 140 equivalent feet. When calculating the total duct length add equivalent lengths of all transitions and adaptors plus the lengths of all straight duct sections.
•240 CFM Vertical exhaust (3 1/4" x 10" duct).
•260 CFM Horizontal exhaust (3 1/4" x 10" duct).
See page 2-3 for additional information
Subject to change without notice. This system is designed to |
|
be updated daily if necessary. Dimension Express is not |
|
responsible for use of superseded, voided, or outdated data |
|
sheets. Because of the difficulty or impracticability of deter- |
|
mining actual damages, liability of Dimension Express shall |
|
not exceed $50.00. |
|
Copyright © Dimension Express, 2000. |
131 |
Exhaust outlet connects to
3 1/4" X 10" duct
13"
30"
20 1/2
16 1/2"
Door Open
14 5/8"
(not to scale)
Bottom of unit is angled
|
66" Min. |
|
|
30" |
|
Minimum |
|
|
Minimum |
|
mounting |
|
mounting |
|
|
height from |
|
height from |
|
|
floor |
|
cooking |
|
|
|
|
|
surface |
|
|
|
|
|
|
|
|
|
|
13" |
30" |
Wall View (not to scale)
• NEVER reuse Data Sheets. Data Sheets are subject to change without |
• Call Dimension Express if you have any questions at (775) 833-3633 • |
notice. Dimension Express is a FREE service bureau and is updated daily, |
• Always refer to a current Code at a Glance or manufacturer directory • |
it makes far more sense to spend the time necessary to request new Data |
• Data Sheet codes change on the first of odd numbered months at 12:01am • |
Sheets for each project, as opposed to the problems, time, costs, and risks |
BN232 • A131B278C150 • 31469 • 002906 • 114434 • 13804 |
associated with reusing old Data Sheets. |