Jenn-air JXW9048WP, JXW9036WP Dimension Guide

PRODUCT MODEL NUMBERS
ELECTRICAL REQUIREMENTS
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
LOCATION REQUIREMENTS
Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located inside the range hood on the rear wall of the range hood.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
VENTING REQUIREMENTS
A 10" (25.4 cm) round vent system is needed for installation (not included). The hood exhaust opening is 10" (25.4 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates back pressure and air turbulence that greatly reduce performance.
Vent system can terminate either through the roof or wall.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
The maximum equivalent vent lengths are: 10" (25.4 cm) round vents - 60 ft (18.3 m)
30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) Commercial Style Wall-Mount Canopy Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274316
10/08/09
JXW9030W JXW9036W
JXW9048W
Roof Venting
A. Roof cap B. 10" (25.4 cm) round vent*
A. Wall cap B. 10" (25.4 cm) round vent*
A
A
B*
B*
Wall Venting
Example vent system
The following example falls within the maximum recommended vent length.
PRODUCT DIMENSIONS
Front view
Back view
Vent Piece Equivalent Length
45° elbow 2.5 ft (0.8 m)
90° elbow 5.0 ft (1.5 m)
1 - 90° elbow 1 - wall cap 8 ft (2.4 m) straight
= 5.0 ft (1.5 m) = 0.0 ft (0.0 m) = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
A
Page 1 of 2
90 elbow
2 ft
(0.6 m)
6 ft (1.8 m)
Wall cap
18¹⁄₁₆" (45.9 cm) for 48" (121.9 cm) Hood 12¹⁄₁₆" (30.6 cm) for 36" (91.4 cm) Hood 9¹⁄₁₆" (23.0 cm) for 30" (76.2 cm) Hood
CL
6¹⁄₂" (16.5 cm)
2¹⁄₄" (5.7 cm)
25" (63.5 cm)
30" (76.2 cm) 36" (91.4 cm) 48" (121.9 cm)
12" (30.5 cm)
18" (45.7 cm)
8³⁄₈" (21.3 cm)
9⁷⁄₈" (25.0 cm)
D
CL
A
B
E
C
18¹³⁄₁₆" (47.8 cm) for 48" (121.9 cm) Hood 12¹³⁄₁₆" (32.5 cm) for 36" (91.4 cm) Hood 9¹³⁄₁₆" (24.9 cm) for 30" (76.2 cm) Hood
. Top of hood
B. Wood support
C. Bottom of hood D. Home wiring location
E. Knockout into terminal box
18" (45.7 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10274316
10/08/09
Optional Full-Width Duct Cover Installations
Installation Dimensions IMPORTANT:
Minimum distance X: 30" (76.2 cm)
Suggested maximum distance X: 36" (91.4 cm)
Page 2 of 2
12"
(30.5 cm)
12"
(30.5 cm)
18"
(45.7 cm)
A. Optional full-width duct cover B. Vent hood
A
30" (76.2 cm), 36" (91.4 cm),
or
B
48"
cabinet opening width
(If installed between cabinets)
c
tneVrevo
p
onaC
cm)
(121.9
d
e
su
f
i()
Min. cabinet
opening width
y
A B
18" (45.7 cm)
clearance upper
cabinet to countertop
min.
36" (91.4 cm)
countertop height
A. 84" (213.4 cm) minimum for
installations with canopy only.
X
Bottom of canopy
to cooking surface
B. 96" (243.8 cm) minimum for
installations with optional duct cover.
13" (33.0 cm)
Loading...