36" LOW PROFILE WALL-MOUNT PERIMETRIC CANOPY HOOD
JXW8936DS – 36" x 331⁄8-543⁄4" x 219⁄16"
PRODUCT DIMENSIONS
MODEL # JXW8936DS
Width of chimney 13
A
Width of hood 36 91.4
B
Height of hood 1
C
A
B
FRONT VIEW
E
D
C
Height of chimney 25
D
Overall height with vented installation (min.-max.)
E
Depth of chimney 12
F
Depth of hood 21
G
Vent collar diameter 6 15.2
H
Width from chimney to edge of hood 12
I
in cm
1
8 33.4
5
8 4.2
1
2 64.8
1
8-
33
3
54
4
3
8 31.4
9
16 54.8
3
8 31.4
1 of 2
84.1-
139.1
SIDE VIEW
F
TOP VIEW
F
G
H
G
I
A
B
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
8796 BdZw 616
JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
A
36" LOW PROFILE WALL-MOUNT PERIMETRIC CANOPY HOOD
JXW8936DS – 36" x 331⁄8-543⁄4" x 219⁄16"
OPENING/CLEARANCE DIMENSIONS
2 of 2
FRONT VIEW
H
v
D
v
B
E
MODEL # JXW8936DS
in cm
Width of entry location for vent and power supply – ceiling option (min.-
A
10-13
max.)
Width of entry location for vent and
B
power supply – wall option (min.-max.)
Width of cabinet opening (min.) 36 91.4
C
10-13
25.4-
33.0
25.4-
33.0
Minimum height from entry location
C
F
G
to ceiling for vent and power supply – wall option (vented installation)
D
Minimum height from entry location to ceiling for vent and power supply – wall option (non-vented installation)
2 5.1
9 22.9
Height from hood to entry location for vent and power supply – wall option
E
17 43.2
(min.)
Suggested distance from hood to electric cooking surface (min.-max.)
F
Suggested distance from hood to gas cooking surface (min.-max.)
Height from upper cabinet to
G
countertop (min.)
Depth of entry location for vent and
H
power supply – ceiling option
Recommended vent and power supply
v
entry location
24-36
30-36
18 45.7
9
61.0-
91.4
76.2-
91.4
1
2 24.1
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof or wall. For non-vented (recirculating) installation, refer to recirculation kit instructions for further information.
LOCATION REQUIREMENTS
Ceiling structure must be able to support 80 lb (36.6 kg). For vented installation, the chimney can be adjusted for ceilings between
7' 10" (2.39 m) and 10' 4" (3.15 m). For non-vented (recirculating) installation, the chimney can be adjusted
for ceilings between 7' 10" (2.39 m) and 10' 4" (3.15 m).
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide