JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
36" LOW PROFILE WALL-MOUNT CANOPY HOOD
JXW8736DS – 36" x 337⁄8-551⁄2" x 193⁄4"
PRODUCT DIMENSIONS
MODEL # JXW8736DS
Width of chimney 131⁄8 33.4
A
Width of hood 36 91.4
B
Height of hood 23⁄8 6.0
C
FRONT VIEW
A
B
E
D
C
Height of chimney 251⁄2 64.8
D
Overall height with vented installation (min.-max.)
E
Depth of chimney 123⁄8 31.4
F
Depth of hood 193⁄4 50.1
G
Vent collar diameter 6 15.2
H
Width from chimney to edge of hood 123⁄8 31.4
I
in cm
337⁄8-
551⁄2
1 of 2
86.0-
141.0
SIDE VIEW
F
TOP VIEW
F
G
H
G
I
A
B
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8315B dZw1114
JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
36" LOW PROFILE WALL-MOUNT CANOPY HOOD
JXW8736DS – 36" x 337⁄8-551⁄2" x 193⁄4"
OPENING/CLEARANCE DIMENSIONS
2 of 2
FRONT VIEW
H
v
D
v
B
E
MODEL # JXW8736DS
in cm
Width of entry location for vent and
power supply – ceiling option (min.-
A
10-13
max.)
Width of entry location for vent and
B
power supply – wall option (min.-max.)
Width of cabinet opening (min.) 36 91.4
C
10-13
25.4-
33.0
25.4-
33.0
Minimum height from entry location
C
F
G
to ceiling for vent and power supply –
wall option (vented installation)
D
Minimum height from entry location
to ceiling for vent and power supply –
wall option (non-vented installation)
2 5.1
9 22.9
Height from hood to entry location for
vent and power supply – wall option
E
17 43.2
(min.)
Suggested distance from hood to
electric cooking surface (min.-max.)
F
Suggested distance from hood to gas
cooking surface (min.-max.)
Height from upper cabinet to
G
countertop (min.)
Depth of entry location for vent and
H
power supply – ceiling option
Recommended vent and power supply
v
entry location
24-36
30-36
18 45.7
91⁄2 24.1
61.0-
91.4
76.2-
91.4
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof or wall. For
non-vented (recirculating) installation, refer to recirculation kit instructions
for further information.
LOCATION REQUIREMENTS
Ceiling structure must be able to support 100 lb (45.4 kg).
For vented installation, the chimney can be adjusted for ceilings between
7' 10" (2.39 m) and 10' 4" (3.15 m).
For non-vented (recirculating) installation, the chimney can be adjusted
for ceilings between 7' 10" (2.39 m) and 10' 4" (3.15 m).
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8315B dZw1114