Jenn-Air JXI8742DS User Manual

JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
G
H
A
B
E
F
D
C
G
H
42"/36" LOW PROFILE ISLAND-MOUNT CANOPY HOODS
JXI8742DS – 36" x 303⁄8-475⁄8" x 24 JXI8736DS – 42" x 303⁄8-475⁄8" x 24
PRODUCT DIMENSIONS
MODEL # JXI8742DS JXI8736DS
Width of chimney 13 33.0 13 33.0
A
Width of hood 42 106.7 36 91.4
B
FRONT VIEW
F
A
B
E
D
C
Height of hood 23⁄8 6.0 23⁄8 6.0
C
Height of chimney 213⁄4 55.2 213⁄4 55.2
D
Overall height of chimney
E
with extension
Overall height with vented
F
installation (min.-max.)
Depth of chimney 111⁄4 28.6 111⁄4 28.6
G
Depth of hood 24 61.0 24 61.0
H
Vent collar diameter 6 15.2 6 15.2
I
Width from chimney to edge
J
of hood
Depth from chimney to back
K
edge of hood
1 of 2
in cm in cm
28-
451⁄4
303⁄8-
475⁄8
141⁄2 36.8 111⁄2 29.2
63⁄8 16.2 63⁄8 16.2
71.0-
115.0
77.2-
120.1
28-
451⁄4
303⁄8-
475⁄8
71.0-
115.0
77.2-
120.1
SIDE VIEW
G
TOP VIEW
G
H
K
I
A
B
H
J
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
8315AdZw 1114
JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
42"/36" LOW PROFILE ISLAND-MOUNT CANOPY HOODS
JXI8742DS – 36" x 303⁄8-475⁄8" x 24 JXI8736DS – 42" x 303⁄8-475⁄8" x 24
OPENING/CLEARANCE DIMENSIONS
MODEL # JXI8942DS JXI8936DS
Ceiling height
A
D
B
A
C
Suggested distance from hood to electric cooking surface (min.-max.)
B
Suggested distance from hood to gas cooking surface (min.-max.)
Countertop height
C
Height from bottom of hood
D
to ceiling (A – B – C = D)
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof. For non-vented (recirculating) installation, refer to recirculation kit instructions for further information.
LOCATION REQUIREMENTS
Ceiling structure must be able to support 100 lb (45.4 kg). For vented installation, the chimney can be adjusted for ceilings between 7' 6" (2.29 m)
and 10' (3.04 m). For non-vented (recirculating) installation, the chimney can be adjusted for ceilings
between 7' 6" (2.29 m) and 10' (3.04 m).
in cm in cm
24-36
30-36
61.0-
91.4
76.2-
91.4
24-36
30-36
2 of 2
61.0-
91.4
76.2-
91.4
FRONT VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
8315AdZw 1114
Loading...