Jenn-Air JXI8536DS User Manual

JENN-AIR® DETAILED PLANNING DIMENSIONS
C
F
G
A
B
E
D
C
F
G
36" PYRAMID-STYLE ISLAND-MOUNT CANOPY HOOD
JXI8536DS – 36" x 321⁄2-529⁄16" x 27
PRODUCT DIMENSIONS
MODEL # JXI8536DS
Width of chimney 133⁄16 33.5
A
Width of canopy 36 91.4
B
Height of trim 23⁄8 6.1
C
A
B
FRONT VIEW
E
Height of canopy 5 12.7
D
Overall height with vented installation (min.-max.)
E
Overall height with non-vented (recirculating)
D
installation (min.-max.)
Depth of chimney 121⁄4 31.0
F
Depth of canopy 27 68.6
G
Width of vent collar 61⁄4 15.8
H
Depth of vent collar 33⁄4 9.5
I
Width from chimney to edge of canopy 117⁄16 29.0
J
Depth from chimney to back edge of canopy 73⁄8 18.7
K
in cm
321⁄2-
461⁄2
321⁄2­529⁄16
1 of 2
82.6-
118.0
82.6-
133.5
SIDE VIEW
TOP VIEW
F
G
K
I
F
H
A
B
J
G
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8316BAdZw1114
JENN-AIR® DETAILED PLANNING DIMENSIONS
36" PYRAMID-STYLE ISLAND-MOUNT CANOPY HOOD
JXI8536DS – 36" x 321⁄2-529⁄16" x 27
OPENING/CLEARANCE DIMENSIONS
MODEL # JXI8536DS
Ceiling height
A
D
Suggested distance from hood to electric cooking surface (min.-max.)
B
Suggested distance from hood to gas cooking surface (min.-max.)
Countertop height
C
Height from bottom of hood to ceiling (A – B –
D
C = D)
in cm
24-36
27-36
2 of 2
61.0-
91.4
68.6-
91.4
A
FRONT VIEW
B
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof. For non-vented (recirculating) installation, refer to recirculation kit instructions for further information.
LOCATION REQUIREMENTS
Ceiling structure must be able to support 100 lb (45.4 kg). For vented installation, the chimney can be adjusted for ceilings between 7' 9" (2.36 m)
and 9' 10" (3.00 m). For non-vented (recirculating) installation, the chimney can be adjusted for ceilings
between 7' 9" (2.36 m) and 10' 4" (3.15 m).
C
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation. All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8316BAdZw1114
Loading...