Jenn-Air JXI5042WS0, JXI5042WS, JXI5036WS0, JXI5036WS Owner’s Manual

JENN-AIR_36"AND 42"(91.4CM, AND 106.7CM)
HOOD
HOTTEDECUISINIEREJENN-AIR_EN|LOT
DE36"ET42"(91,4CM ET106,7CM)
InstallationInstructionsand Use&CareGuide
For questions about features, operation/performance, parts, accessories, or service in the U.S.A., call:
1-800-JENNAIR (1-800-536-6247) or visit our website at www.jennair.com.
In Canada, call: 1-800-807-6777, or visit our website at www.jennair.ca.
Au Canada, pour assistance, installation ou service, composez le 1-800-807-6777 ou visitez notre site web & www.jennair.ca.
Table of Contents/Table des matieres ................................... 2
IMPORTANT: READ AND SAVE THESE INSTRUCTIONS.
FOR RESIDENTIAL USE ONLY.
IMPORTANT : LIRE ET CONSERVER CES INSTRUCTIONS.
POUR UTILISATION Ri_SIDENTIELLE UNIQUEMENT.
JENN-AIR°
LI3U2A/W10274308E
TABLEOF CONTENTS
TABLEDESMATIERES
RANGE HOOD SAFETY ................................................................. 2
INSTALLATION REQUIREMENTS ................................................ 3
Tools and Parts ............................................................................ 3
Location Requirements ................................................................ 4
Venting Requirements .................................................................. 5
Electrical Requirements ............................................................... 6
INSTALLATION INSTRUCTIONS .................................................. 6
Prepare Location .......................................................................... 6
Install Range Hood ....................................................................... 7
Make Electrical Connection ......................................................... 8
Install Duct Covers ....................................................................... 8
Install Filters.................................................................................. 9
Complete Installation ................................................................... 9
RANGE HOOD USE ........................................................................ 9
Display .......................................................................................... 9
Light............................................................................................ 10
Timer........................................................................................... 10
Fan Speed Buttons .................................................................... 10
RANGE HOOD CARE ................................................................... 10
Cleaning ...................................................................................... 10
WIRING DIAGRAM ...................................................................... 12
ASSISTANCE OR SERVICE ......................................................... 13
In the U.S.A................................................................................ 13
In Canada ................................................................................... 13
Accessories ................................................................................ 13
WAR RANTY .................................................................................. 14
SECURITE DE LA HOTTE DE CUlSINIERE ............................... 15
EXIGENCES D'INSTALLATION ................................................... 17
Outils et pieces ........................................................................... 17
Exigences d'emplacement ......................................................... 17
Exigences concernant I'evacuation ........................................... 18
Specifications electriques .......................................................... 19
INSTRUCTIONS D'INSTALLATION ............................................. 20
Preparation de I'emplacement ................................................... 20
Installation de la hotte ................................................................ 20
Raccordement electrique ........................................................... 22
Installation des cache-conduits ................................................. 22
Installation des filtres.................................................................. 23
Achever I'installation .................................................................. 23
UTILISATION DE LA HOTTE ....................................................... 23
Afficheur ..................................................................................... 23
Eclairage ..................................................................................... 24
Minuterie ..................................................................................... 24
Boutons de vitesse du ventilateur.............................................. 24
ENTRETIEN DE LA HO'I-rE DE CUlSINIF:RE ............................. 25
Nettoyage ................................................................................... 25
SCHEMA DE CABLAGE .............................................................. 26
ASSISTANCE OU SERVICE ......................................................... 27
Accessoires ................................................................................ 27
GARANTIE ..................................................................................... 28
RANGE HOOD SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow instructions.
All safety messages willtell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
2
iMPORTANT SAFETY iNSTRUCTiONS
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
Use this unit only in the manner intended by the manufacturer. If you have questions, contact the
manufacturer.
Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
Do not operate any fan with a damaged cord or plug. Discard fan or return to an authorized service facility for examination and/or repair.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), the American Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
When cutting or drilling into wall or ceiling; do not damage electrical wiring and other utilities.
Ducted fans must always be vented outdoors.
CAUTION: For general ventilating use only. Do not use
to exhaust hazardous or explosive materials and vapors.
CAUTION: To reduce risk of fire and to properly exhaust
air, be sure to duct air outside - do not vent exhaust air into spaces within walls or ceilings, attics or into crawl spaces,
or garages.
WARNING: TO REDUCE THE RISK OF FIRE, USE ONLY
METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF A RANGE TOP
GREASE FIRE: [] Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
[] Always turn hood ON when cooking at high heat or when
flambeing food (i.e. Crepes Suzette, Cherries Jubilee,
Peppercorn Beef Flamb6).
[] Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
[] Use proper pan size. Always use cookware appropriate for
the size of the surface element.
WARNING: TO REDUCE THE RISK OF INJURY TO
PERSONS IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: a
[] SMOTHER FLAMES with a close fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
[] NEVER PICK UP A FLAMING PAN - you may be burned. [] DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
[] Use an extinguisher ONLY if:
- You know you have a class ABC extinguisher, and you already know how to operate it.
- The fire is small and contained in the area where it started.
- The fire department is being called.
- You can fight the fire with your back to an exit.
aBased on "Kitchen Fire Safety Tips" published by NFPA. [] WARNING: To reduce the risk of fire or electrical shock,
do not use this fan with any solid-state speed control device.
READ AND SAVE THESE INSTRUCTIONS
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed
here.
Tools needed
Level
Drill with 11¼"(3.0 cm), %" (9.5 mm), %4" (2.75 mm) and V8"(3.0 mm) drill bits
Pilot hole drill bits (determined by chimney support attachment method)
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver Parts needed
Home power supply cable
2 - 1/2"(12.7 mm) UL listed or CSA approved strain reliefs
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also need:
Recirculation Kit Part Number W10272065 for non-vented (recirculating) installations only. See "Assistance or Service"
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with ventilator and light bulbs installed
8 vertical supports
2 glass mounting brackets
Glass mantle
Mounting template
Upper horizontal support
Horizontal support
4 plastic brackets (for lower chimney fixings)
2 plastic brackets (for upper chimney fixings)
68-4x8mmscrews
4 - 3.5 x 9.5 mm glass mantle mounting screws
4-5x45mmscrews
Product Dimensions
133/8" 15" (38.0 Ore)
25W' (64.0 crn)
_t_ (4.0crn)
36" - 42" (91.4 om to 106.7 ore)
*Vented installations only
**Non-vented (recirculating) installations only
Installation Clearances
IMPORTANT: Observe all governing codes and ordinances. Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating
plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical Requirements" section.
Because of the size and weight of this island hood, the chimney support must be securely attached to the ceiling.
For plaster or drywall ceilings, the chimney support must be attached to joists. If this is not possible, you must build a
support structure behind the plaster or drywall. The support structure must be able to support 80 Ibs (36.6 kg).
The range hood is factory set for venting through the roof or wall. For non-vented (recirculating) Installation see "Non-vented
(recirculating) Installations" in "Install Range Hood" section. Recirculation Kit Part Number W10272065 is available from your
dealer or an authorized parts distributor. All openings inceiling and wall where range hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24
CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such
standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and
Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
1
B*
1
C
1
A. Ceiling height B. Hood height from ceifing to bottom of the
range hood: A-C-D=B
C. Hood height: 24" (61.0 cm) min. from
electric cooking surface, 30" (76.2 cm) min. from gas cooking surface, suggested 36" (91.4 cm) max
D. Countertop height
IM PO RTANT:
Minimum distance "C": 24" (61.0 cm) from electric cooking surface.
Minimum distance "C": 27" (68.6 cm) from gas cooking surfaces.
Suggested maximum distance "C": 36" (91.4 cm)
For vented installations, the chimneys can be adjusted for ceilings between 8' (2.4 m) and 9' 11" (3.0 m).
For non-vented (recirculating) installations, the chimneys can be adjusted for ceilings between 8' (2.4 m) and 10' 4" (3.1 m).
*NOTE:Therangehoodchimneysareadjustableanddesigned tomeetvaryingceilingorsoffitheightsdependingonthe distance"C"betweenthebottomoftherangehoodandthe cookingsurface.Forhigherceilings,aStainlessSteelChimney ExtensionKitPartNumberW10272072isavailablefromyour dealeroranauthorizedpartsdistributor.Thechimneyextension replacestheupperchimneyshippedwiththerangehood.
(ve_"_ed modes @_y}
Vent system must terminate to the outdoors, except for non- vented (recirculating) installations.
Do not terminate the vent system in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-type wall cap.
Use metal vent only. Rigid metal vent is recommended. Plastic or metal foil vent is not recommended.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
For the most efficient and quiet operation:
Use no more than three 90° elbows.
Make sure there is a minimum of 24" (61.0 cm) of straight vent between the elbows if more than 1 elbow is used.
Do not install 2 elbows together.
Use clamps to seal all joints in the vent system.
Use caulking to seal exterior wall or roof opening around the cap.
The size of the vent should be uniform.
Cold Weather Installations
An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to
minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal
break. The break should be as close as possible to where the vent
system enters the heated portion of the house.
Non-vented (recirculating) Roof Venting
A. Deflector
B. 8" (20.3 cm) round vent
NOTE: Wall venting can be an option for 2-story homes.
Calculating Vent System Length
To calculate the length of the system you need, add the equivalent feet (meters) for each vent piece used in the system.
Vent piece 8" (20.3 cm) round
45° elbow 2.5 ft
90° elbow 5.0 ft
A. Roof cap B. 8" (20.3 cm) round vent
(0.8 m)
(1.5m)
Makeup Air
Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your
area.
Venting Methods
This range hood is factory set for venting through the roof. A 8" (20.3 cm) round vent system is needed for installation (not
included). The hood exhaust opening is 8" (20.3 cm) round. NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce performance.
For Non-Vented (recirculating) Installations
If it is not possible to vent cooking fumes and vapors to the outside, the hood can be used in the non-vented (recirculating) version, using a Recirculation Kit (which includes charcoal filters and a deflector). To order, see the "Assistance or Service"
section.
Maximum equivalent vent length is 35 ft (10.7 m).
Example vent system
90° e, bow I .......W aHcap
The following example falls within the maximum recommended vent length of 35 ft (10.7 m).
1 - 90° elbow = 5.0 ft (1.5 m) 1 - wall cap = 0.0 ft (0.0 m) 8 ft (2.4 m) straight = 8.0 ft (2.4 m)
Length of system = 13.0 ft (3.9 m)
Observeallgoverningcodesandordinances. Ensurethattheelectricalinstallationisadequateandin
conformancewithNationalElectricalCode,ANSI/NFPA70(latest edition),orCSAStandardsC22.1-94,CanadianElectricalCode, Part1andC22.2No.0-M91(latestedition)andalllocalcodes
andordinances. Ifcodespermitandaseparategroundwireisused,itis
recommendedthataqualifiedelectriciandeterminethatthe groundpathisadequate.
Acopyoftheabovecodestandardscanbeobtainedfrom:
NationalFireProtectionAssociation
OneBatterymarchPark
Quincy,MA02269
CSAInternational
8501EastPleasantValleyRoad
Cleveland,OH44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.
If the house has aluminum wiring, follow the procedure below:
1. Connect a section of solid copper wire to the pigtail leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices. Wire sizes and connections must conform with the rating of
the appliance as specified on the model/serial rating plate. The model/serial plate is located behind the filter on the rear wall of the range hood.
Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA
Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and
ordinances.
INSTALLATIONINSTRUCTIONS
It is recommended that the vent system be installed before 6. Tape template in place on the ceiling at the marked the range hood is installed, centerline.
Before making cutouts, make sure there is proper clearance within the ceiling for exhaust vent.
Range hood is to be installed 24" (61.0 cm) min. for electric cooking surfaces, 27" (68.6 cm) min. for gas cooking surfaces, to a suggested maximum of 36" (91.4 cm) above the cooking
surface.
Check your ceiling height and the range hood height maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall or non- vented.
3. Select a flat surface for assembling the range hood. Place covering over that surface.
Excessive Weight Hazard
Use two or more people to move and install range hood.
Failure to do so can result in back or other injury.
4,
Using 2 or more people, lift range hood onto covered surface.
5.
Determine and mark the centerline on the ceiling where the range hood will be installed, considering the requirements for ceiling support structures. See the "Location Requirements" section. Make sure the range hood is centered over the cooking surface.
7,
Use a pencil to mark the mounting screws, wire access and duct hole locations on the ceiling.
NOTE: Mounting hole locations should be into the ceiling support structure.
Remove the template.
8.
Drill 4 - 3Ae"(4.8 mm) pilot holes for mounting the upper horizontal support.
9.
Determine the required location for the home power supply cable and drill a 1/2"(1.3 cm) diameter hole for wire access.
10.
Run wire through the home power supply cable according to the National Electrical Code or CSA Standards and local
codes and ordinances. There must be enough 1/2"conduit and wires from the fused disconnect (or circuit breaker) box
to make the connection in the hood's electrical terminal box. NOTE: Do not reconnect power until installation is complete.
Use caulk to seal all openings.
11. (For vented installations only.) Using a jigsaw or keyhole saw, cut a 81/2"(21.6 cm) diameter hole for the vent duct.
6
12. Attach the upper horizontal support bracket with 4 - 5 x 5. Connect glass mantle to range hood with the 2 glass 45 mm wood screws, mounting brackets and 4 - 3.5 x 9.5 mm screws.
A
B A
I
i
A. Upper horizontal support
1. Position the 4 vertical supports (A) with the notches at the bottom and attach to the range hood using 16 - 4 x 8 mm
screws.
2. Attach the horizontal support (B) using 8 - 4 x 8 mm screws.
6=
Attach the range hood assembly to the upper horizontal
A. Glass mounting bracket B. 3.5 x 9.5 mm screws
support attached to the ceiling using 16 - 4 x 8 mm screws and tighten.
A
_m..............
C ..................................................
[
A. Vertical supports B. Horizontal support
C. Notched end
3=
Attach a second set of vertical supports (A) and set the vertical height (B). See "Installation Clearances" in the "Location Requirements" section to help determine the desired dimension for vertical height "B."
A
B
I I
A. Verticalsuppoarts B. Verticalheight
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii i1i!i!!ii
! !
A.Mounting screws
Connect Vent System
1. Install vent system.
2. Push duct over the exhaust outlet. Seal all connections with vent clamps.
Non-Vented (recirculating) Installation
1. Attach the air deflector to the upper horizontal support using 4 mounting screws.
4. Using 2 people, place the glass mantle onto the range hood.
A. Glass mantle
A. Deflector B. Mounting screws
2=
Measure the length of 8" (20.3 cm) duct (not included) needed to connect the transition to the deflector.
NOTE: Vent should fit up inside the deflector 1" (2.5 cm) minimum.
3. Install vent between the transition and the deflector. NOTE: To make vent installation easier, temporarily remove
the deflector from the chimney support bracket and replace after vent section is in place.
4. Seal all connections with vent clamps.
Electrical Shock Hazard
Disconnect power before servicing. Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1=
Disconnect power.
2.
Remove terminal box cover.
3.
Remove the knockout in the terminal box cover and install a UL listed or CSA approved 1/2"strain relief.
4=
Run 3 wires, black, white and green (14AWG), in 1/2"conduit from service panel to terminal box. Use caulking to seal opening.
g ......................................F _
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire in terminal box.
Failure to do so can result in death or electrical shock.
7. Connect green (or bare) ground wire from home power supply to yellow-green ground wire (E) in terminal box using UL listed
wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Check all light bulbs are secure in their sockets.
11. Reconnect power.
1. Attach the vertical duct cover supports using 4 - 4 x 8 mm screws.
D
E c
A. UL listed or CSA approved strain refief
B. Home power supply cable
C. Terminal box D. Black wires
E. Green (or bare) wire connected to yellow-green wire F. White wires
5. Use UL listed wire connectors and connect black wires (D) together.
6. Use UL listed wire connectors and connect white wires (F) together.
B
A. Screws B. Vertical duct cover support
2. Slide upper duct covers into place until springs "click."
A. Upper duct cover B. Spring
8
3. Attach lower duct covers using a plastic bracket at each corner (4 needed).
3=
Position the upper cap and fix it in place using the cap lock spring provided.
C
A. Upper duct cover B. Lower duct cover
C. Plastic bracket
For non-vented (recirculating installations):
1. Install optional charcoal filter, wrapping it around the grease filter.
2. Place the charcoal filter mat around the grease filter and fix it in place by using the cap lock springs provided.
RANGE HOOD USE
The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the
kitchen.
Control Panel
The range hood controls arelocated onthe front side of the
canopy.
A B C D E
B
A. Charcoal filter mat B. Grease filter C. Charcoal filter side
lock springs
For all installations:
4. Install the grease filter. See "Range Hood Care" section.
Check Range Hood Operation
If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown.
NOTE: To get the most efficient use from your new range hood, read the "Range Hood Use" section.
Charcoal Filter Saturation Alarm
After 120 hours of fan function, the display will show "Replace Charcoal Filter" when the fan is active. When this icon shows in
the display, the charcoal filters should be replaced. See "Range Hood Care" section.
To reset the charcoal filter saturation alarm, press and hold the POWER DECREASE button for 5 seconds. The "Replace Charcoal Filter" icon will no longer be displayed.
D. Upper cap
E. Cap lock spring F. Grease filter support
=. o............7,o,88-88
Ir I
A. Power decrease D. Light
B. Power increase E. Timer
C. Display
Grease Filter Saturation Alarm
After 30 hours of fan function, the display will show "Clean Grease Filter" when the fan is active. When this icon shows in the
display, the installed grease filters should be washed. See "Range Hood Care" section.
To reset the grease filter saturation alarm, press and hold the POWER INCREASE button for 5 seconds. The "Clean Grease
Filter" icon will no longer be displayed.
Audible Signal Activation and Deactivation
The audible signals can be activated or deactivated by pressing the "LIGHT" button for 5 seconds.
If the audible signal is activated, a tone will sound, and "Snd" will appear on the display for 3 seconds.
If the audible signal is deactivated, "Snd" will appear on the display for 3 seconds.
Charcoal Filter (Recirculation Accessory) Inclusion and Exclusion
When the charcoal filter is in use (recirculating mode), press and hold the POWER DECREASE and POWER INCREASE buttons at
the same time for 5 seconds. "Able" will appear on the display for 3 seconds.
If the charcoal filter is not used (vented mode), press and hold the POWER DECREASE and POWER INCREASE buttons at the
same time for 5 seconds. "None" will appear on the display for 3 seconds.
Loading...