Jenn-Air JXI5036WS Dimension Guide

JENN-AIR® DETAILED PLANNING DIMENSIONS
H
I
J
K
A
B
C
D
G
F
E
H
I
J
K
36" GLASS COLLECTION ISLAND-MOuNT CANOPy HOOD
JXI5036WS – 36" x 363/4-573⁄4" x 251⁄4"
PRODuCT DIMENSIONS
MODEL # JXI5036WS
A
Width of chimney extension 14
A
Width of chimney 15 38.2
B
Width of hood without glass mantle 19
C
Width of glass mantle 36 91.4
D
FRONT VIEW
B
G
E
F
C
D
H
Height of glass mantle
E
Height of hood below glass mantle 1
F
Overall height with vented installation (min.-max.)
G
Overall height with non-vented (recirculating) installation (min.-max.)
Depth of chimney extension 13
H
Depth of chimney 13
I
Depth of hood without glass mantle 14
J
Depth of glass mantle 25
K
Vent collar diameter 7
L
Width from chimney to edge
M
of glass mantle
Depth from chimney to back edge
N
of canopy
in cm
7
8 37.8
3
4 50.0
1
4 0.7
1
2 4.0
3
36
4-
3
54
4
3
36
4-
3
57
4
1
4 33.6
3
8 33.8
3
4 37.5
1
4 64.0
7
8 20.0
1
2 26.7
10
6 15.2
1 of 4
93.4-
139.1
93.4-
146.7
SIDE VIEW
TOp VIEW
I
J
K
N
I
L
K
M
B
D
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JRC120065A 07/2012
JENN-AIR® DETAILED PLANNING DIMENSIONS
36" GLASS COLLECTION ISLAND-MOuNT CANOPy HOOD
JXI5036WS – 36" x 363/4-573⁄4" x 251⁄4"
OPENING/CLEARANCE DIMENSIONS
D
B
A
C
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 15-amp fused, electrical circuit is required.
VENTING REQUIREMENTS
The hood is factory set for venting through the roof. For non-vented (recirculating) installation, refer to recirculation kit instructions for further information.
LOCATION REQUIREMENTS
Ceiling structure must be able to support 80 lb (36.6 kg). For vented installation, the chimney can be adjusted for ceilings
between 8' (2.4 m) and 9' 11" (3.0 m). For non-vented (recirculating) installation, the chimney can be
adjusted for ceilings between 8' (2.4 m) and 10' 4" (3.1 m).
2 of 4
FRONT VIEW
MODEL # JXI5036WS
in cm
Ceiling height
A
Suggested distance from hood to electric cooking surface (min.-max.) 24-36 61.0-91.4
B
Suggested distance from hood to gas cooking surface (min.-max.) 27-36 68.6-91.4
Countertop height
C
Height from bottom of hood to ceiling (A – B – C = D)
D
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JRC120065A 07/2012
Loading...
+ 2 hidden pages