Jenn-air JXD7030YS, JXD7036YS Dimension Guide

A
H
30" (76.2 cm) and 36" (91.4 cm) Retractable (Pop-Up) Downdraft Vent System
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10342490C
2/8/2012
Page 1 of 3
COUNTERTOP CUTOUT DIMENSIONS
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
JXD7030Y JXD7036Y
Electrical
A 120 Volt, 60 Hz., AC only 15-amp fused, electrical circuit is required.
Top trim widths: 30" (76.2 cm) 36" (91.4 cm)
13¹⁄₂" (34.3 cm)
retractable vent height
27" (68.6 cm) for 30" (76.2 cm) vent 33" (83.8 cm) for 36" (91.4 cm) vent
16¹⁄₂" (42.0 cm)
10"
(25.4 cm)
2¹⁄₈" (5.4 cm)
28¹⁄₂"
(72.4 cm)
³⁄₈" (0.95 cm)
1¹⁄₂" (3.8 cm)
13¹⁄₈" (33.4 cm)
5¹⁄₄"(13.3 cm) for 30" (76.2 cm) vent 8¹⁄₄"(21.0 cm) for 36" (91.4 cm) vent
³⁄₄
(1.9 cm)
LOCATION REQUIREMENTS
NOTE: Downdraft vent is installed directly behind the cooktop. Install the
downdraft vent first, then install the cooktop. IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the downdraft vent. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the terminal box cover.
Downdraft vent location should be away from strong draft areas, such as windows, doors, and strong heating vents or fans.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Consult the cooktop manufacturer installation instructions before making any cutouts.
Check that the downdraft vent and cooktop location will clear the cabinet walls, backsplash, and rear wall studs inside the cabinet.
Check for the minimum distance between the front edge of the countertop and the front edge of the cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent.
All openings in ceiling and wall where the downdraft vent will be installed must be sealed.
Grounded electrical outlet is required. See “Electrical Requirements” section.
When installing the downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to the cabinet.
Cabinet Construction:
Downdraft vent is designed for use in a cabinet with a depth of 24" (61 cm). Some installations require a countertop deeper than 25" (63.5 cm). See the Countertop Cutout Dimensions section.
The maximum depth of the overhead cabinet is 13" (33 cm). Overhead cabinets installed at either side of the downdraft vent must be 18" (45.7 cm) above the cooking surface.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local codes.
NOTES:
See cooktop manufacturer’s instructions for cooktop cutout depth and width.
Use dimensions for vent system cutout location that applies to your installation.
Interior mounted blower systems connect with 6" (15.2 cm) round vent. The cutout locations for this vent system will depend on your specific installation.
CABINET DIMENSIONS
IMPORTANT: Countertops with a bull-nosed front edge are not
recommended for these installations.
Some models require a countertop deeper than 25" (63.5 cm); see the following Countertop Cutout Dimensions section.
To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.
See Cooktop Installation Instructions for complete cutout dimensions, location dimensions and installation details.
Interior-mounted blower motor model
7⁵⁄₈" (19.4 cm)
D
E
F
B
C
G
A= ¹⁄₂" (12.7 mm) minimum
21⁄₁₆" (54.1 cm)
All cutouts are for 6" (15.2 cm) diameter vent system.
Locate power supply junction box at lower left hand rear corner of the cabinet.
23³⁄₄" (60.3 cm)
Centerline of cooktop cutout
21⁄₁₆" (54.1 cm)
A
. Downdraft vent B. Cooktop C. Measurement of cooktop rear
overhang.
D. D = Measurement of cooktop rear
overhang (C) + 1¹³⁄₁₆" [46.2 mm] (E)
F. ½" (12.7 mm) minimum G. ¼" (6.4 mm) minimum H. Countertop and backsplash
I. ½" (12.7 mm) minimum
I
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. W10342490C
2/8/2012
Page 2 of 3
VENTING METHODS - INTERIOR MOUNTED VENT MOTOR ONLY
Determine which venting method is best for your application. Vent system can terminate through either the wall or floor.
A
NOTE: For island locations, the blower motor can be mounted for right, left, or rear venting if needed for your application. Most island applications would still require the venting to be directed down through the floor.
g
Island Location Vent system installed under a concrete slab using PVC sewer
pipe.
B
IMPORTANT: Make sure there is proper clearance within the wall or floor before making exhaust vent cutouts.
Use heavy (rigid) metal vent.
Venting system must terminate to the outside.
Do not terminate the vent system in an attic or other enclosed area.
Do not use 4" (10.2 cm) laundry-type wall caps.
Do not install 2 elbows together.
Do not use plastic or metal foil vent.
The length of vent system and number of elbows should be kept to a minimum to provide efficient performance.
Use no more than three 90° elbows
Make sure there is a minimum of 24" (61 cm) of straight vent between the elbows if more than one elbow is used.
Use clamps or duct tape to seal all joints in the vent system.
Use caulking tape to seal the exterior wall or floor opening around cap.
Do not cut joist or stud. If vent cutout falls over a joist or stud, a supporting frame must be constructed.
Flexible metal vent is not recommended. If it is used, calculate each foot of flexible vent as 2 ft (0.6 m) of rigid metal vent.
Flexible elbows count twice as much as standard elbows.
Recommended Vent System Length:
For either interior-mounted or exterior-mounted blower installations, the vent system length should not exceed the maximum lengths listed in the Maximum Length of Vent System chart. See Calculating Vent System Length in the Venting Methods section in the Installation Instructions.
Cold Weather Installations
An additional back draft damper should be installed to minimize backward cold air flow and a thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break.
The break should be as close as possible to where the vent system enters the heated portion of the house.
Makeup Air
Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
VENTING REQUIREMENTS
D
Island location
C
Front (standard) mounted
blower motor
Rear mounted blower
motor
A
A. ½" (12.7 mm) minimum to
backsplash or rear wall
B. ³⁄₄" (19.1 mm) maximum
backsplash depth
C. 27¹⁄₂" (69.9 cm) on 30" (76.2 cm)
models
¹⁄₂" (85.9 cm) on 36" (91.4 cm)
33 models
D. D = Measurement of cooktop rear
overhang + 1
¹³⁄₁₆" (46.2 mm)
A
A. Down vent
B
A
A. Down vent B. Left vent
ht vent
C. Ri
C
Front (Standard) Mounted Blower Motor
B
A
M
L
K
J
D
C
E
F
G
H
I