These installation instructions cover different models. The
appearance of your particular model may differ slightly from the
illustrations in these Installation Instructions.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
For proper installation, the following minimum clearances must
exist above and below the cutout opening.
NOTE: Upper oven must have heat deector kit installed to
direct exhaust away from microwave console (Refer to Wall Oven
Manual for Deector Kit Installation)
Parts supplied
The Microwave Drawer is preassembled.
■ 1" (2.5 cm) mounting screws (4)
■ 1" (2.5 cm) deector screws (2)
■ Flush mount deector (1)
Optional Parts
■ 27" (68.6 cm) Trim Kit (W11170223) for JMDFS24GS
■ 27" (68.6 cm) Trim Kit (W11264778) for JMDFS24HM
Verification needed
■ Installer must conrm presence of anti tip block. Refer to the
anti-tip block section in the manual.
■ Check local codes. Check existing electrical supply. See
“Electrical Requirements”.
■ It is required that all electrical connections be made by a
licensed, qualied electrical installer.
Location Requirements
This product is suitable for use below electric or gas built-in
ovens. This product is not suitable for use below cooktops.
The Microwave Drawer may be located in a cabinet or below
the counter, and/or below a built-in oven. Check the opening
where the Microwave Drawer will be installed. The location must
provide:
IMPORTANT: Observe all governing codes and ordinances.
■ Wood cabinetry.
■ Cutout opening that is plumb and square. See “Minimum
Cutout Dimensions” in the “Minimum Dimensions” section.
■ Cutout oor that is solid, level, and ush with bottom of
cabinet cutout.
■ Support for weight of at least 100 lbs (45.4 kg), which
includes Microwave Drawer and items placed inside.
■ Grounded electrical outlet. See the “Electrical Requirements”
section.
■ Minimum installation clearances for installation location. See
the “Minimum Dimensions” section.
■ Complete enclosure around the recessed portion of the
IMPORTANT: Observe all governing codes and ordinances.
Required:
■ A 120 V, 60 Hz, AC-only, 15 or 20 A electrical supply with a
fuse or circuit breaker.
Recommended:
■ A time-delay fuse or time-delay circuit breaker
■ A separate circuit serving only this Microwave Drawer
GROUNDING INSTRUCTIONS
■
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
"
and grounded.
WARNING:Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven. A short power supply
cord is provided to reduce the risks resulting from becoming
entangled in or tripping over a longer cord.
The drawer opens 151/
4
4
" (38.7 cm).
SAVE THESE INSTRUCTIONS
15 ¹/₄" (38.7 cm)
Page 5
24" (61.0 CM) AND 30" (76.2 CM) STANDARD MOUNT
B
C
D
E
F
G
H
I
I
J
K
N
L
M
A
Top view
Cabinet Dimensions
Cabinet Preparation
Cabinet
face
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle location
C. Anti-Tip block
D. 3" (76.20 mm)
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 221/8" (561.98 mm) opening
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. 24" models: Allow 7/8" (22.2 mm)
overlap
30" models: Allow 41/16" (103.19mm)
overlap
J. 24" (609.60 mm) minimum depth
K. Allow 9/16" (5.62 mm)
L. Platform must support 100 lb (45.4 kg)
M. 159/16" (395.27 mm) opening
N. Allow 3/4" (19.05 mm) overlap
O. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS30HL Model - 111/16" (42.86 mm)
JMDFS24HM Model - 13/4" (44.45 mm)
JMDFS30HM Model - 13/4" (44.45 mm)
O
Drawer
face
Anti-Tip block
G
5
Page 6
24" (61.0 CM) AND 30" (76.2 CM) FLUSH MOUNT
L
I
Cabinet Dimensions
Cabinet Preparation
A
B
C
R
G
K
D
E
F
H
O
Note: The face of the shelf must
sit 1⁷/₈" (47.6 mm) back from
the face of the cabinet.
M
J
Shelf face
L
N
Cabinet face
Flush mount deector vent
³/₄" (19.05 mm)
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle location
C. Anti-Tip block
D. 3" (76.20 mm)
Anti-Tip block
K
K
Top view
6
Drawer
face
Mounting
cleat
P
Cabinet
Q
face
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 24" models: 243/16" (614.4 mm) minimum
30" models: 301/4" (768.4 mm) minimum
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. 1" (25.40 mm) minimum
J. 24" (609.60 mm) minimum depth
K. 221/8" (561.98 mm) “mounting cleat to
mounting cleat”
L. 17/8" (47.62 mm)
M. 167/8"(428.62 mm) opening
N. Platform must support 100 lb (45.4 kg)
O. 161/8" (409.56 mm)
P. 0" (0 mm) = ush
Q. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS30HL Model - 111/16" (42.86 mm)
JMDFS24HM Model - 13/4" (44.45 mm)
JMDFS30HM Model - 13/4" (44.45 mm)
R. 159/16" (395.3 mm)
Page 7
27" (68.6 CM) TRIM KIT ACCESSORY STANDARD MOUNT
B
C
D
E
F
G
H
I
I
J
K
N
L
M
A
Top view
(To be used with JMDFS24GS or JMDFS24HM)
Cabinet Preparation
Cabinet Dimensions
O
Cabinet
face
Anti-Tip block
G
Drawer
face
Trim
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle
location
C. Anti-Tip block
D. 3" (76.20 mm)
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 221/8" (561.98 mm) opening
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. Allow 23/8" (60.5 mm) overlap
J. 24" (609.60 mm) minimum depth
K. Allow 9/16" (5.62 mm)
L. Platform must support 100 lb (45.4 kg)
M. 159/16" (395.27 mm) opening
N. Allow 3/4" (19.05 mm) overlap
O. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS24HM Model - 1¾" (44.45 mm)
7
Page 8
27" (68.6 CM) TRIM KIT ACCESSORY FLUSH MOUNT
Top view
L
I
Cabinet Dimensions
B
(To be used with JMDFS24GS or JMDFS24HM)
Cabinet Preparation
A
C
R
G
K
D
E
F
H
O
Note: The face of the shelf must
sit 1⁷/₈" (47.6 mm) back from
the face of the cabinet.
M
J
Shelf face
L
N
Cabinet face
Flush mount deector vent
³/₄" (19.05 mm)
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle location
C. Anti-Tip block
D. 3" (76.20 mm)
Anti-Tip block
K
K
8
Draw
face
Mounting
cleat
er
Q
P
face
Cabinet
Trim
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 271/8" (689 mm) minimum
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. 1" (25.40 mm) minimum
J. 24" (609.60 mm) minimum depth
K. 221/8" (561.98 mm) “mounting cleat to
mounting cleat”
L. 17/8" (47.62 mm)
M. 167/8"(428.62 mm) opening
N. Platform must support 100 lb (45.4 kg)
O. 161/8" (409.56 mm)
P. 0" (0 mm) = ush
Q. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS24HM Model - 1¾" (44.45 mm)
R. 159/16" (395.3 mm)
Page 9
INSTALLATION INSTRUCTIONS
WARNING
Crush Hazard
Microwave drawer can tip and fall out of opening.
Install anti-tip block to wall per installation instructions.
Failure to do so can result in serious injury or burns.
Min. 6" (15.
14¹³⁄₁₆"
(37.6 cm)
A
D
Install the Anti-Tip Block
To reduce the risk of tipping of the drawer, the anti-tip block
must be properly installed located 1413/16" (37.6 cm) above the
oor on which the Microwave Drawer will sit. If the Microwave
Drawer is ever moved to a different location, the anti-tip block
must also be moved and installed.
1. Measure 1413/16" (37.6 cm) from the cutout oor where the
Microwave Drawer will sit and mark a line on the wall.
2. Position the bottom of the anti-tip block on the line marked
on the wall and attach the anti-tip block to the wall with
screws. Make sure the screws are secured to wood or metal
studs.
NOTES:
■ The anti-tip block is required before installing the Microwave
Oven Drawer.
■ The anti-tip block is to be provided by the installer.
■ When fastening, be sure that the screws do not penetrate
electrical wiring or plumbing.
Anti-Tip Block Dimensions.
Max.16" (40.6 cm)
2 cm)
Install the Microwave Drawer
WARNING
Excessive Weight Hazard
Use two or more people to move and install
microwave oven.
Failure to do so can result in back or other injury.
1. Empty Microwave Drawer of any loose contents.
2. Using two or more people, slide Microwave Drawer all the
way into the opening, and center the Microwave Drawer.
3. Open the Microwave Drawer, and mark the four holes in the
mounting ange.
NOTE: The screw holes in the mounting ange of both sides
must be fully over the wood of the wall or cabinet.
4. Remove Microwave Drawer.
5. Using 1/8" (3.17 mm) drill, drill four pilot holes into the
cabinet through the marks made in Step 3.
6. Prepare the holes by installing a 1" (2.5 cm) screw in and out
of each pilot hole.
1" (2.5 cm)
3¹⁄₂"
(8.9 cm)
Using sturdy wood screws (installer to provide), securely install
the anti-tip block in the upper-right corner of the cutout, making
sure the block is completely stable. The bottom of the block
must be 1413/16" (37.6 cm) from the cutout oor.
A. Anti-tip block
7. With the Microwave Drawer near the opening, plug the
Microwave Drawer into the grounded 3 prong outlet.
8. Reinsert Microwave Drawer into the opening, open the
drawer, and align holes in mounting ange with pilot holes in
the cabinet.
A. 1" (2.5 cm) mounting
screws(4)
B. Mounting ange screw holes
A
C. Mounting ange
D. Optional 27" (68.6 cm) Trim
Kit Parts
D
B
C
NOTE: For the 27" (68.6 cm) side trim kit, align the side trim
pieces holes with the front frame holes then push product into
opening. Then secure with the screws as instructed in step 9.
9
Page 10
9. Install four 1" (2.5 cm) screws to secure the Microwave
³/₄" (19.05 mm)
2/19
Drawer in place, then close the drawer.
Install the Deflector Vent For Flush
Installation
1. Position deector vent and mark holes.
2. Pre-drill using a 1/8" (3.17 mm) bit before mounting.
Refer to illustrations below for vent positioning.
4. Guide the drawer into the prepared opening. Avoid contact
with the sides of the cutout opening and also pinching the
cord between the oven and the wall.
5. Slide the drawer all the way back until the mounting anges
touch the cleats mounted in the cabinet opening.
6. Open the drawer. Using the 4 holes on the drawer as a
template, pre drill the cabinet using a 1/8" (3.17 mm) bit.
See illustration below.
Mounting
flange
flange
Shelf detail showing the deector vent during installation.
Shelf detail showing the deector vent installed.
7. Secure the drawer with the 4 screws supplied.
Complete Installation
1. Check the operation of Microwave Drawer by placing 1 cup
(250 mL) of water in the Microwave Drawer and programming
cook time of 1 minute at 100% power.
2. If the Microwave Drawer does not operate:
■ Check that a household fuse has blown, or a circuit
breaker tripped. Replace the fuse or reset the circuit
breaker. If the problem continues, call an electrician.
■ Check that the power supply cord is plugged into a
grounded 3 prong outlet.
■ See the Use and Care Guide for troubleshooting
information.
Installation is now complete.
Save these Installation Instructions for future use.
ASSISTANCE
Call your authorized dealer or service center. When you call,
you will need the microwave drawer model number and serial
number, both of which can be found on the model and serial
number plate.
If you need additional assistance, call us at our toll-free number
or visit our website listed in the Use and Care Guide.
To access the model and serial number plate, fully open the
microwave drawer. The plate is located on a at surface just
beyond the back wall of the drawer.
3. Place the drawer adjacent to the wall or cabinet opening.
Plug the power supply cord into the grounded 3 prong outlet.
10
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.