24" (61.0 CM) AND 30" (76.2 CM) MICROWAVE
DRAWER AND 27" (68.6 CM) TRIM KIT
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION DU TIROIR À
FOUR À MICRO-ONDES DE 24 PO (61,0 CM) ET 30
PO (76,2 CM) ET DE LA TROUSSE DE GARNITURE
DE 27 (68,6 CM)
Table of Contents/Table des matières
MICROWAVE DRAWER SAFETY ..................................................2
INSTALLATION REQUIREMENTS .................................................3
Tools and Parts .............................................................................3
Location Requirements ................................................................3
Minimum Dimensions...................................................................3
Electrical Requirements ...............................................................4
24" (61.0 CM) AND 30" (76.2 CM) STANDARD MOUNT .............5
Cabinet Preparation .....................................................................5
24" (61.0 CM) AND 30" (76.2 CM) FLUSH MOUNT .....................6
Cabinet Preparation .....................................................................6
27" (68.6 CM) TRIM KIT ACCESSORY STANDARD MOUNT .... 7
Cabinet Preparation .....................................................................7
27" (68.6 CM) TRIM KIT ACCESSORY FLUSH MOUNT .............8
Cabinet Preparation .....................................................................8
INSTALLATION INSTRUCTIONS ...................................................9
Install the Anti-Tip Block ..............................................................9
Install the Microwave Drawer .......................................................9
Install the Deector Vent For Flush Installation .........................10
Complete Installation .................................................................10
ASSISTANCE ................................................................................10
IMPORTANT:
Installer: Leave installation instructions with the homeowner.
Homeowner: Keep installation instructions for future reference.
IMPORTANT:
Save for local electrical inspector’s use.
IMPORTANT :
Installateur : Remettre les instructions d’installation au propriétaire.
Propriétaire : Conserver les instructions d’installation pour référence
ultérieure.
IMPORTANT :
À conserver pour consultation par l’inspecteur local des installations
électriques.
W11257634B
TINSKB267MRR0
SÉCURITÉ DU TIROIR À MICRO-ONDES .................................11
EXIGENCES D’INSTALLATION ...................................................12
Outillage et pièces ......................................................................12
Exigences d’emplacement .........................................................12
Dimensions minimales ...............................................................12
Spécications électriques ..........................................................13
SUPPORT STANDARD DE
24 PO (61,0 CM) ET 30 PO (76,2 CM) .........................................14
Préparation de l’armoire .............................................................14
EN AFFLEUREMENT DE
24 PO (61,0 CM) ET 30 PO (76,2 CM) .........................................15
Préparation de l’armoire .............................................................15
SUPPORT STANDARD POUR TROUSSE
DE GARNITURE DE 27 PO (68,6 CM) .........................................16
Préparation de l’armoire .............................................................16
EN AFFLEUREMENT POUR TROUSSE DE
GARNITURE DE 27 PO (68,6 CM) ...............................................17
Préparation de l’armoire .............................................................17
INSTRUCTIONS D’INSTALLATION .............................................18
Installation de la cale de bride antibasculement .......................18
Installation du tiroir à micro-ondes ............................................18
Installer le déecteur d’évacuation pour une
installation en afeurement ........................................................19
Terminer l’installation .................................................................. 20
ASSISTANCE ................................................................................20
INSTALLATION REQUIREMENTS
These installation instructions cover different models. The
appearance of your particular model may differ slightly from the
illustrations in these Installation Instructions.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Tape measure
■ #2 Phillips screwdriver
■ Drill
■ 1/8" (3.17 mm) drill bit
■ Marker or pencil
Minimum Dimensions
Minimum Wall Oven Combination Installation
Clearances
For proper installation, the following minimum clearances must
exist above and below the cutout opening.
NOTE: Upper oven must have heat deector kit installed to
direct exhaust away from microwave console (Refer to Wall Oven
Manual for Deector Kit Installation)
Parts supplied
The Microwave Drawer is preassembled.
■ 1" (2.5 cm) mounting screws (4)
■ 1" (2.5 cm) deector screws (2)
■ Flush mount deector (1)
Optional Parts
■ 27" (68.6 cm) Trim Kit (W11170223) for JMDFS24GS
■ 27" (68.6 cm) Trim Kit (W11264778) for JMDFS24HM
Verification needed
■ Installer must conrm presence of anti tip block. Refer to the
anti-tip block section in the manual.
■ Check local codes. Check existing electrical supply. See
“Electrical Requirements”.
■ It is required that all electrical connections be made by a
licensed, qualied electrical installer.
Location Requirements
This product is suitable for use below electric or gas built-in
ovens. This product is not suitable for use below cooktops.
The Microwave Drawer may be located in a cabinet or below
the counter, and/or below a built-in oven. Check the opening
where the Microwave Drawer will be installed. The location must
provide:
IMPORTANT: Observe all governing codes and ordinances.
■ Wood cabinetry.
■ Cutout opening that is plumb and square. See “Minimum
Cutout Dimensions” in the “Minimum Dimensions” section.
■ Cutout oor that is solid, level, and ush with bottom of
cabinet cutout.
■ Support for weight of at least 100 lbs (45.4 kg), which
includes Microwave Drawer and items placed inside.
■ Grounded electrical outlet. See the “Electrical Requirements”
section.
■ Minimum installation clearances for installation location. See
the “Minimum Dimensions” section.
■ Complete enclosure around the recessed portion of the
Microwave Drawer.
2" (5.1 cm)
B
A. Upper oven cutout
B. Microwave drawer cutout
3
Product Dimensions
24" (61.0 cm) and 30" (76.2 cm)
"
4¹¹⁄₁₆
(11.9 cm)
1
³/₄
16
" (4.4 cm
"
)
4" (10.2 cm)
)
A
Dimension A:
24" (61.0 cm) Product - 237/8" (60.6 cm)
30" (76.2 cm) Product - 2915/16" (76.0 cm)
Dimension B:
JMDFS24GS Model - 15/8" (4.1 cm)
JMDFS30HL Model - 111/16" (4.3 cm)
JMDFS24HM Model - 13/4" (4.4 cm)
JMDFS30HM Model - 13/4" (4.4 cm)
Optional 27" (68.6 cm) Trim Kit:
"
4¹¹⁄₁₆
(11.9 cm)
" (4.4 cm
1
³/₄
"
16
)
)
4" (10.2 cm)
"
23
⁷/₈
(60.6 cm)
"
₄
26
³/
(68.0 cm)
21
⁵/₈ "
(54.9 cm)
21
⁵/₈ "
(54.9 cm)
22 ¹/₁₆"
(56.0 cm)
B
22 ¹/₁₆"
(56.0 cm)
1⁵/₈"
(4.1 cm)
14 ⁹⁄₁₆ "
(37.1 cm
14 ⁹⁄₁₆
Electrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
Required:
■ A 120 V, 60 Hz, AC-only, 15 or 20 A electrical supply with a
fuse or circuit breaker.
Recommended:
■ A time-delay fuse or time-delay circuit breaker
■ A separate circuit serving only this Microwave Drawer
GROUNDING INSTRUCTIONS
■
For all cord connected appliances:
The microwave oven must be grounded. In the event of
an electrical short circuit, grounding reduces the risk of
electric shock by providing an escape wire for the electric
current. The microwave oven is equipped with a cord
having a grounding wire with a grounding plug. The plug
must be plugged into an outlet that is properly installed
"
and grounded.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock. Consult a qualified
electrician or serviceman if the grounding instructions are
not completely understood, or if doubt exists as to whether
the microwave oven is properly grounded.
Do not use an extension cord. If the power supply cord is
too short, have a qualified electrician or serviceman install
an outlet near the microwave oven. A short power supply
cord is provided to reduce the risks resulting from becoming
entangled in or tripping over a longer cord.
The drawer opens 151/
4
4
" (38.7 cm).
SAVE THESE INSTRUCTIONS
15 ¹/₄" (38.7 cm)
24" (61.0 CM) AND 30" (76.2 CM) STANDARD MOUNT
B
C
D
E
F
G
H
I
I
J
K
N
L
M
A
Cabinet Dimensions
Cabinet Preparation
Cabinet
face
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle location
C. Anti-Tip block
D. 3" (76.20 mm)
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 221/8" (561.98 mm) opening
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. 24" models: Allow 7/8" (22.2 mm)
overlap
30" models: Allow 41/16" (103.19mm)
overlap
J. 24" (609.60 mm) minimum depth
K. Allow 9/16" (5.62 mm)
L. Platform must support 100 lb (45.4 kg)
M. 159/16" (395.27 mm) opening
N. Allow 3/4" (19.05 mm) overlap
O. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS30HL Model - 111/16" (42.86 mm)
JMDFS24HM Model - 13/4" (44.45 mm)
JMDFS30HM Model - 13/4" (44.45 mm)
O
Drawer
face
Anti-Tip block
G
5
24" (61.0 CM) AND 30" (76.2 CM) FLUSH MOUNT
Cabinet Dimensions
Cabinet Preparation
A
B
C
R
G
K
D
E
F
H
O
Note: The face of the shelf must
sit 1⁷/₈" (47.6 mm) back from
the face of the cabinet.
M
J
Shelf face
L
N
Cabinet face
Flush mount deector vent
³/₄" (19.05 mm)
A. 6" (152.40 mm) minimum
16" (406.40 mm) maximum
B. Suggested electrical receptacle location
C. Anti-Tip block
D. 3" (76.20 mm)
Anti-Tip block
K
K
Top view
6
Drawer
face
Mounting
cleat
P
Cabinet
Q
face
E. 31/2" (88.90 mm)
F. 4.5" (114.30 mm)
G. 24" models: 243/16" (614.4 mm) minimum
30" models: 301/4" (768.4 mm) minimum
H. 1413/16" (376.24 mm) to bottom
of Anti-Tip block
I. 1" (25.40 mm) minimum
J. 24" (609.60 mm) minimum depth
K. 221/8" (561.98 mm) “mounting cleat to
mounting cleat”
L. 17/8" (47.62 mm)
M. 167/8"(428.62 mm) opening
N. Platform must support 100 lb (45.4 kg)
O. 161/8" (409.56 mm)
P. 0" (0 mm) = ush
Q. JMDFS24GS Model - 15/8" (41.28 mm)
JMDFS30HL Model - 111/16" (42.86 mm)
JMDFS24HM Model - 13/4" (44.45 mm)
JMDFS30HM Model - 13/4" (44.45 mm)
R. 159/16" (395.3 mm)