INSTALLATION INSTRUCTIONS 24" (59.5 CM)
INDOOR/OUTDOOR ELECTRIC WARMING
DRAWER
INSTRUCTIONS D’INSTALLATION DU TIROIR-
RÉCHAUD POUR USAGE INTÉRIEUR/
EXTÉRIEURDE 24 PO (59,5CM)
Table of Contents / Table des matières
WARMING DRAWER SAFETY.......................................................2
INSTALLATION REQUIREMENTS .................................................3
Tools and Parts .............................................................................3
Location Requirements ................................................................3
Electrical Requirements ..............................................................6
INSTALLATION INSTRUCTIONS ...................................................6
Install Warming Drawer ................................................................6
Complete Installation ...................................................................7
SÉCURITÉ DU TIROIR-RÉCHAUD ...............................................8
EXIGENCES D’INSTALLATION .....................................................9
Outils et pièces .............................................................................9
Exigences d’emplacement ...........................................................9
Spécications électriques .........................................................12
INSTRUCTIONS D’INSTALLATION .............................................12
Installation du tiroir-réchaud ......................................................12
Terminer l’installation .................................................................. 13
IMPORTANT:
Save for local electrical inspector’s use.
IMPORTANT :
Conserver ces instructions à l’usage de l’inspecteur des installations électriques local.
W11260097A
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
■ Phillips screwdriver
■ Flat-blade screwdriver
■ Measuring tape
■ Level
■ Drill
8
■ 1/
" (3.5 cm) hole saw
Parts Supplied
■ Two 19 x 3.5 mm screws
Check local codes. Check existing electrical supply. See
“Electrical Requirements.”
It is recommended that all electrical connections be made by a
licensed, qualied electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
■ Cutout dimensions that are shown must be used. Given
dimensions provide minimum clearance with warming
drawer.
■ Recessed installation area must provide complete enclosure
around the recessed portion of the warming drawer.
■ Grounded electrical supply is required. See “Electrical
Requirements” section.
■ Electrical supply outlet should be located in the rear wall
on the upper right-hand side of the cutout or in an adjacent
cabinet. The outlet must be recessed. If the electrical outlet
is located in an adjacent cabinet, a 1/8" (3.5 cm) minimum
diameter hole should have been drilled in the back of the
cutout or support surface to pass the power supply cord
through to the outlet.
■ Warming drawer support surface must be solid, level, and
ush with bottom of cabinet cutout.
5
■ 21
/8" (55.0 cm) minimum cabinet depth.
For best performance results make sure the warming drawer is
leveled before completing installation. There is no way to level
the warming drawer after it has been installed. If the installation
is not level, the door may slide open or not seal tightly, allowing
heat to escape.
NOTE: If installing the warming drawer below another product,
refer to that product’s literature for any installation requirements.
Product Dimensions
B
A
E
C
D
A. 215/8" (55.0 cm) oven depth
B. 21/16" (55.4 cm) recessed width
C. 59/16" (14.1 cm) recessed height
D. 237/16" (59.5 cm) overall width
E. 49/16" (11.7 cm) drawer front height
3
Clearance Dimensions
Warming Drawer Installed Below Oven
Front view
A. 2215/16" (58.2 cm) cutout height for both oven and
warming drawer
B. 31" (78.7 cm) minimum/recommended height
from oor
C. 215/8" (55.0 cm) cutout width
D. 235/8" (60.0 cm)minimum cabinet width
C
A
D
B
NOTES:
■ If installed with an oven, no separator between them.
■ Warming drawer can be installed under a single oven.
■ The warming drawer cannot be leveled after being installed.
For outdoor installation, follow the cutout dimensions for a single warming drawer. Install the outdoor warming drawer in a permanent
xture.
4
Clearance Dimensions - Flush Installation
Warming Drawer Installed Below Oven
Back
E
A Width of ush inset cutout (minimum) 23/16" (60.2 cm)
B Height of ush inset cutout (minimum) 23/4" (60.3 cm)
C Bottom of cutout to oor (minimum) If installed under model JMC6224 5" (12.7 cm)
D Width of opening (minimum) 215/8" (55.0 mm) for JJD3024HM
E Depth of cutout (minimum) 227/16" (57.05 cm) for JJD3024HM
F Depth to Side Cleat 13/16" (20.5 mm) for JJD3024HM
g Recommended outlet location
A
1" (25 mm)
Side Cleats*
⁷⁄₈” (22 mm)
Platform*
Top View
g
B
D
C
Side Cleat*
E
If installed under any other model 31" (78.7 cm)
221/2" (57.13 cm) for JJD3024HL
27/32" (21.3 mm) for JJD3024HL
Flush Installation Requirements
A 229/16" (57.3 cm) minimum cutout depth is required.
These dimensions will result in a 1/8" (3 mm) reveal on all sides of the warming drawer.
*The front face of the cleats and platforms will be visible and should be treated as a nished surface.
5