JennAir JJB6424HL, JJB6424HM Installation Guide

INSTALLATION INSTRUCTIONS
IMPORTANT:
Save for local electrical inspector's use.
IMPO
À conserver pour consultation par l'inspecteur local des installations électriques.
BUILT-IN COFFEE SYSTEM
INSTRUCTIONS D’INSTALLATION
MACHINE À CAFÉ ENCASTRÉE
Table of Contents/Table des matières
BUILT-IN COFFEE SYSTEM SAFETY ...........................................2
INSTALLATION REQUIREMENTS .................................................2
Tools and Parts .............................................................................2
Location Requirements ................................................................2
Electrical Requirements ...............................................................4
INSTALLATION INSTRUCTIONS ...................................................5
Install the Mounting Brackets ......................................................5
Install the Coffee System .............................................................6
Complete Installation ...................................................................7
SÉCURITÉ DE LA MACHINE À CAFÉ ENCASTRÉE ...................8
EXIGENCES D’INSTALLATION .....................................................8
Outils et pièces .............................................................................8
Exigences d’emplacement ...........................................................8
INSTRUCTIONS D’INSTALLATION .............................................11
Installation des platines de montage .........................................11
Installation de la machine à café ................................................12
Terminer l’installation ..................................................................13
RTANT :
W11328306C

BUILT-IN COFFEE SYSTEM SAFETY

B
CD
A
G

INSTALLATION REQUIREMENTS

Tools and Parts

Tools Needed
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
■ Measuring tape
■ Pencil
■ Level
■ Masking tape
Parts Supplied
All of the following parts are provided, but some parts may not be used. The location of your coffee system installation will determine which parts you will use.
®
■ T20
Torx®† screwdriver
■ Drill
■ 1/16" (2 mm) drill bit

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
■ Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance with coffee system.
■ The built-in coffee system must be installed in cabinetry with
the dimensions provided.
■ Follow the installation instructions for any cabinetry used
to house the built-in coffee system. Make sure cabinet is securely attached to the wall.
■ Follow the installation instructions.
■ Grounded electrical supply is required. See “Electrical
Requirements” section.
■ Refer to installation instructions for cutout dimensions for
any appliances installed above or below the built-in coffee system.
IMPORTANT: To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This coffee system has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperature of 194°F (90°C).
A. Mounting brackets/runners (2) B. Metal bottom trim piece (1)
(Optional)
C. Black plastic bracket spacers
(4) (2 mm thick)
D. Power supply cord clip (1)
Torx and T20 are trademarks of Acument Intellectual Properties, LLC.
E. 3/16" x 5/8" (4.5 x 16 mm)
T20 screws (17)
F. 3/16"x3/8" (4.2 x 9.5 mm)
T20 screws (2)
G. Metal shims (4) (1 mm thick)
2
E
F
Product Dimensions
23⁷/₁₆" ± ¹/₁₆"
(59.5 ± 0.1 cm)
17⁷/" ± ¹/₁₆"
(45.4 ± 0.1 cm)
¹³/₁₆" ± ¹/₁₆"
(2.0 ± 0.1 cm)
Flush Mount
1"
(2.5 cm)
22¹/₁₆"
(56 cm)
18/₁₆"
(46.5 cm)
1¹¹/₁₆"
(4.3 cm)*
1¹¹/₁₆"
(4.3 cm)
16⁷/"
(42.9 cm)
21⁷/₁₆"
(54.5 cm)
Cabinet Dimensions
Standard Mount
/₁₆"
(3.0 cm)
18³/₁₆" ± ¹/₁₆"
(46.1 ± 0.1 cm)
1¹¹/₁₆"
(4.3 cm)*
24¹/₁₆"
(61.1 cm)
19/"
17¹¹/₁₆" + 1/16"
(45 + 0.17 cm)
(50 cm)
(85 cm)
33/₁₆" Min.
21/₁₆" Min.
1¹¹/₁₆"
(4.3 cm)
*Venting cutout suggested, not mandatory. If the unit is being installed above a wooden cabinet bottom, be
sure to install the metal trim piece at the front edge of the cabinet bottom.
A
7
/16
" (10 mm)
22¹/₁₆"
(56 cm)
17¹¹/₁₆" + 1/16"
(45 + 0.17 cm)
33/₁₆" Min.
*Venting cutout suggested, not mandatory.
1¹¹/₁₆"
(4.3 cm)
19/"
(50 cm)
(85 cm)
A. Flush mount deector vent
21/₁₆" Min.
1¹¹/₁₆"
(4.3 cm)
3
Cutout Top View
15¹⁄₈"
(38.2 cm)
15¹⁵⁄₁₆"
(40.1 cm)
E
B
A
D
C
F
WARNING

Electrical Requirements

14³⁄₈"
(36.1 cm)
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
17⁵⁄₈"
(44.8 cm)
G
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
Electrical Shock Hazard
A. Coffee system B. Non-ush receptacle C. Flush receptacle D. Back of cabinet E. Non-ush receptacle located in upper right
or upper left corner F. Wall behind cabinet G. Coffee system with runners fully extended
IMPORTANT: The coffee system must be electrically grounded in accordance with local codes and ordinances, or in the absence of local codes, with the National Electrical Code, ANSI/ NFPA 70 or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is recommended that a qualied electrical installer determine that the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, Ohio 44131-5575
■ A 120 V, 60 Hz, AC only, 15 A fused, electrical circuit
is required. A time-delay fuse or circuit breaker is also recommended. It is recommended that a separate circuit serving only this coffee system be provided.
■ Check that the outlet provides 120 V power and is correctly
grounded.
4

INSTALLATION INSTRUCTIONS

22 + 1/16 "
(55.9 + 0.07 cm)
A

Install the Mounting Brackets

1. Measure the distance between the side walls of the cabinet.
They should measure 221/16" (55.97 cm). If the distance is greater than 22" + 1/16" (55.9 cm + 0.07 cm), the bracket spacers will need to be used. Four 1 mm bracket spacers are included. See Step 2.
2. If bracket spacers are needed: Position the necessary
spacer(s) behind the mounting brackets. Continue with Step3.
A
4. Using a 1/16" (2 mm) drill, drill the holes marked in Step 3.
5. Secure the mounting brackets to the side cabinets with six
3/16" x 5/8" (4.5 x 16 mm) screws in each bracket.
6. Remove the tape holding the brackets in place.
7. Pull the runners forward until they are fully extended and in
the locked position. Place level across the runners and check levelness. Then place the level along the length of each runner and check levelness from front to back. If the runners are not level, uninstall the mounting brackets and raise or lower the mounting brackets as necessary until they are level.
A
A. Bracket spacers
3. Determine where the mounting brackets will be installed and
with the mounting brackets (and spacers) held or taped in place, mark 6 holes through each mounting bracket onto the side cabinet.
IMPORTANT: The front of the mounting bracket must be 1/16" (2 mm) from the front fascia thickness of the cabinet frame.
NOTE: To accommodate for ush installation with 3/4" (1.9cm) custom cabinets, align the front of the mounting brackets 13/16" (2.1 cm) back from the front of the ush surface.
1/16" (2 mm)
A
B
B
NOTE: If the runners are not level, uninstall the mounting brackets and raise the mounting brackets as necessary using the metal shims provided, until they are level.
x 4
8. If the coffee system is being installed above a wooden
cabinet bottom, use two 3/16" x 5/8" (4.5 x 16 mm) screws to install the metal trim piece at the front edge of the cabinet bottom.
A. Front of mounting bracket 1/16" (2 mm)
from outside of cabinet frame
B. Mark 6 screw holes.
A. Metal trim piece
5
Loading...
+ 11 hidden pages