Sealed Gas Cooktop
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. 8101P653-60
10-28-08
19+15/16”
(50.
6
cm)
28+5/8”
(72.7 cm)
2 1/8”
(5.4 cm)
PRODUCT MODEL NUMBERS
JGD8430AD
Gas supply: The installation of this appliance must
conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI Z223.1Latest Edition, or, in Canada, CAN/CGA-B149 Installation
Code, Latest Edition.
All supply piping, except as noted, should use common
National Pipe Thread (N.P.T.). For all pipe connections
use an approved pipe joint compound resistant to the
action of LP gas.
This appliance is designed for use with the appliance
gas pressure regulator supplied with this appliance. It
must be installed in the gas line ahead of the gas
manifold entrance. It is preset for use with natural gas
and must be converted, as described in the Installation
Instructions for use with LP gas.
This appliance is designed to operate at a pressure of 5"
of water column on natural gas or, if converted for use
with LP gas (propane or butane), 10" water column.
Make sure this appliance is supplied with and adjusted
for the type of gas for which it is designed.
This appliance was adjusted at the factory for use with
natural gas. If, at any time, this appliance is to be used
with a different type of gas, all of the conversion
adjustments described in the Installation Instructions
must be made by a qualified service technician before
attempting to operate the cooktop on that gas. Natural
gas should be supplied to the appliance pressure
regulator at a line pressure between 6" and 14" of water
column or, if converted for LP gas, between 11" and 14".
Install a manual shut-off valve in an accessible location
in the gas line ahead of the appliance pressure regulator
and external to this appliance for the purpose of turning
on or shutting off gas to the appliance.
Make additional pipe connections as necessary ahead of
the shut-off valve to the gas supply source. Assure all
pipe joint connections are gas tight.
Electrical: This appliance is equipped with a threeprong grounded type power cord. A grounded outlet
must be provided. It is recommended that the outlet be
located as illustrated in the instructions.
If the outlet
is to be
mounted in
either a left
or a right
adjacent
cabinet, a
clearance
hole (1-1/2" –
3.18 cm)
must be
provided in the dividing wall between the cabinets.
NOTE: The free length of the appliance’s power cord is
approximately 46" (116.8 cm). In planning the location
of the clearance hole and outlet, the cord’s length
should be considered.
NOTE: The electrical supply required is 110/120 Volt,
A.C., 15-amp, 60-Hz. It is recommended, for
convenience, that this outlet be located in the shaded
areas.
CLEARANCE DIMENSIONS
PRODUCT DIMENSIONS
IMPORTANT: Cutout dimensions are critical. Dimensions must be measured
and cut accurately to within ±1/16" (0.2 cm) to ensure proper fit.
30”30”
(76.2 cm)(76.2 cm)
30”
(76.2 cm)
30”30”
(76.2 cm)(76
.
2
cm)
18”
(45.7 cm)
13”
(33 cm)
8”
(20.3 cm)
Combustib
le
Building Walls
Combustible
Wall Cab
inet
s
13" (33 cm) Max.
Depth of cabinets
above cooktop
21”
(53.4cm)
18”
(45.7 cm)
8”
(20.3 cm)
Installing Cabinetry Over Your Jenn-Air
Cooktop
NOTE: 30" (76.2 cm) minimum vertical
clearance between cooking surface and
construction above the appliance. This
clearance may be reduced to not less than
24" (61 cm) by protecting the underside of
the combustible material or metal cabinet
above the cooking surface with not less
than 1/4" (0.6 cm) insulating millboard
covered with sheet metal not less than
0.0122" (0.3 mm) thick.
Avoid use of cabinets above cooktop for
storage space to eliminate associated
potential hazards such as reaching over
open flames.
Cabinet Clearance to motor for cooling
purpose-minimum of 2" (5 cm).
NOTE: Where possible, 6" (12.5 cm) is
recommended for motor/blower service.
Gas Line InletGas Line
Inl
e
t
LocationL
o
cat
i
o
n
Gas Line Inlet
Location
15”
(38.1 cm)
30”
(76.2 cm)