Jenn-Air JGD8348BDP User Manual

ProstyleTM Grill Cooktop
Model JGD8348BDP _ wEsTFOURTHSTREET.NORTH.NEWTON.,A
Triple Bay ConventionalGas _JENN-AIF_
Dimensionsshowninbothinchesandcentimenters
NOTICE TO INSTALLER: Leavetheseinstructionswiththeappliance.
NOTICE TO CONSUMER: Retaintheseinstructionsforfuturereference.
j_ 23,81crn
SELECTAPPROPRIATE FOR CUTOUT
DUCTCUTOUT
1" (SEEDUCTING DIMENSIONS
%
,i
3 13/16" " I [11S.90 ¢m]
_9.6B crn,- I I
,s,B,,o.1,°oco, ®® ® 14
Blower may be CLEARANCE
rotated for horizontal REQUIRED REGULATOR EACH E
orvertical directionby _ BOX looseningnuts DRAIN JAR _ END OF
Accessibleinside 14, 28 11/16° BOX around blower inlet. -_ i:_; c / BURNER
ventilationchamber. A _] [72.87 cm] "
[40.16cm] _MIN. _ I[_-- ND..___.,._ [8 41 c'_}
5 3/4 '
' " _L 3 5,16.
INSTALLATIONINSTRUCTIONS.)
15o PRESSUREREGULATOR
[38.1 cm] 46 13/16" "I
.__ APPLI ANCE
,,r L, I'- ..... ,_
TT(_A- APPLIANCE '
BO PRESSURE BOTTOMOF
CF BAFFLE 3, BURNERBOX
"BL ERII EOVER/
Dimension "A" - provide 2" rain. (5.08 cm) cabinet clearance to motor for cooling purpose.
NOTE: Where possible, 6" (15.54 cm) is recommended for motor/blower service.
Side Clearance: Grills installed near a side wall must allow a minimum clearance of 8" (20.32 cm).
__t INSTRUCTIONSTO INSTALLER:
Access must be provided to remove and empty grease container.
8101P399-60
(09-01-00)
CABINETand COUNTERTOPCUTOUTS
(115.2 cm)
22_" Ref
(58,11 cm)
17.46--22.86 crn)
O_ NOTE: LOWER CONTROLO
\
SEE PAGE 3 ABOUT
i" 1" REINFORCING CABINET FRONT
CABINET
(FRONTVIEW) See cutout suggestions 1-4on page 6.
NOTE: Tolerances for Cutout I
Dimensions are ± 1/16 in (.16 cm)
Asrequiredbyinstallation
(116,2cm] 227/6"Re1
(58.11crn_------
*Recommend8"for
CustomCabinetry.
PANELIS REQUIRED IF THIS DIMENSION
EXCEEDS 5_/_" (14.60 crn).
I
l=o I TOP
==
O
° /
p 4613/16" _ REMOVECORNERSUPPORTSAS NEEDED
'- I -- \
(118.90cm TYP.(4)PLS.
COUNTERTOP
I_ _-_ VIEW
InstallingCabinetryOver Your
Jenn-AirGrill
Minimum horizontal clearancebetweentheedge of the Avoiduse of cabinetsabovecooktopfor storagespace to applianceand combustibleconstructionextendingfrom eliminate associatedpotential hazards such as reaching the cookingsurface to 18" (45.7 cm) above the cooking over open flames.
1=/_" (4.45 cm) at rear
8" (20.32 cm) at sides
surfaceis:
NOTE: This is not the recommended clearance, but Dotted lines indicate range
minimum al,owable clearance. ,.,_ t"--_--"l--_" __ hood construction.
18, above the surface units should be avoided. If cabinet
(45,7¢m)
I_ _ _ (_ (_ _ _ (_ "_ cabinets.minimumof 5 inches beyond the bottom of the
_ storage is to be provided, the riskcan be reduced by
* To eliminate the risk of burns or fire by reaching overheated surface units, cabinet storage space located
installing a range hood that projects horizontally a
.38"om CabinetsAboveCookingTop
MIN.CLEARANCE Maximum depth of cabinets installed above cooking top is
A = 30" (76.2 cm) minimum vertical clearance between cooking surface and construction above
the appliance.
B = 13" (33.02 cm) maximum depth of cabinets
installed above cooking top.
13 inches.
InstallationOf Appliance
Followaccompanying ducting instructions carefully. NOTE: For some cabinet styles, it may be necessary to This appliance is designed to always bevented outdoors, from front to rearinside the cabinet under the Burner Box.
The Countertop Cutout, Cabinet Front Cutout and Duct Installductwork perducting instructions provided. Duct Opening should be prepared according to the illustration openings in cabinet are shown in the drawing on page 1. on pages 1 and 2. Make electricaland gas connections as described below
Installthe Lower Control Panel in the bottom of the in this section of the instructions. Cabinet Cutout as shownusingscrews from Hardware The installationof thisappliance must conformwith local
pack. (Figure 1). codesor,in the absence of localcodes,with the latest
Tl_pVlml LOWER_ PANEL
Figure 1 L. I _=,,_l II LF the area shown in the shaded illustration. This appliance,
Position unitinthe Countertop Cutout. Main Control Panel Code ANSI/NFPA No. 70 USA or current CSA
should overlaptop of Lower Control Panel as shown. STANDARD C22.1 Canadian Electrical Code part 1. (F{gure 2).
reinforce the front of the cabinet by attaching a brace
editionofthe NationalFuelGas Code, ANSI Z.223.1 USA
The electrical supply required is 110/120--volt,A.C., 15 amp, 60 Hz. This appliance is equipped with a grounded
type power cord. A grounded outlet must be provided. It is
recommended, for convenience, this outlet be located in
or current CAN/CGA-B149 INSTALLATION CODE.
when installed, must be electrically grounded in accordance with local codes or, in the absence of local
codes, with the latest edition of the National Electrical
¢¢®e e,,-= ¢ ®
.EL Servicing Cooktop
When servicing cooktop it is necessary to remove the
F_gure2 main top, priorto removing the control panel.