Jenn-Air JGD3536GS, JGD3536GB User Manual

JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
A
B
B
K
L
E
36" JX3™ GAS DOWNDRAFT COOKTOP
JGD3536G – 36" x 185⁄16" x 211⁄2"
PRODUCT DIMENSIONS
1 of 4
TOP VIEW
E
A
A
C
F G
MODEL # JGD3536G
in cm
Overall width 36 91.4
A
Overall depth 211⁄2 54.6
B
I
H
B
Width of cooktop base 3417⁄32 87.7
C
Width of assembled blower motor and plenum 1429⁄64 36.7
D
Height from blower motor to underside
E
of cooktop
Width from left side of cooktop base to
F
blower motor
Width from plenum to right side of cooktop base 951⁄64 24.9
G
Height of cooktop base 49⁄64 10.5
H
Height of cooktop with grates 137⁄64 4.0
I
Height from gas inlet to top of grates 713⁄64 18.3
J
J
Depth of cooktop base 1961⁄64 50.7
K
Height from plenum to underside of cooktop 1649⁄64 42.6
L
185⁄16 46.5
1015⁄64 26.0
FRONT VIEW
SIDE VIEW
D
B
K
L
E
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before
8990dZw117
JENN-AIR® DETAILED PLANNING DIMENSIONSJENN-AIR® DETAILED PLANNING DIMENSIONS
E*
F
e
A
BB
v
H
G
Cabinet
I
D
C
K
J**
L
BB
M
Side
Cabinet
36" JX3™ GAS DOWNDRAFT COOKTOP
JGD3536G – 36" x 185⁄16" x 211⁄2"
2 of 4
OPENING/CLEARANCE DIMENSIONS
MODEL # JGD3536G
A
B
C
A
D
E*
E*
F
F
G
I
H
G
v
C
e
D
H
I
J**
K
L
M
N
J**
v
C
FRONT VIEW
K
O
P
e g
v
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal
cabinet is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
** Based on installation in a 24" (61.0 cm) deep by 341⁄2" (87.6 cm) high
base cabinet with a 11⁄2" (3.8 cm) thick counter top.
GAS REQUIREMENTS
Natural Gas
Side
Cabinet
L
This cooktop is factory-set for use with natural gas.
LP Gas Conversion
Conversion must be done by a qualified service technician. To convert to LP gas, use the LP gas conversion kit provided with the cooktop.
ELECTRICAL REQUIREMENTS
120 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required. A
M
N
M
O
P
time-delay fuse or dedicated circuit is recommended.
VENTING REQUIREMENTS
This cooktop must be exhausted outdoors unless using the duct-free filter kit (JDA7000WX). Refer to kit instructions for further information.
LOCATION REQUIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
• A minimum clearance of 2" (5.1 cm) is recommended between the blower motor and cabinet for proper cooling. A 6" (15.2 cm) clearance is recom­mended for servicing access.
• An under counter built-in oven cannot be installed under this cooktop.
in cm Width of combustible area above cooking surface (min.) Width from cooktop to fixed wall or other combustible material (min.) Width to center of vent opening option (min.)
36 91.4
6 15.2
163⁄16 41.1
Width to outer edge of outlet (min.) 10 25.4 Height to bottom of uncovered wood
or metal cabinet above cooking surface
30 76.2 (min.) Height to bottom of uncovered wood or metal cabinet (min.) Height to center of vent opening option
18 45.7
1411⁄16 37.3
Height to top edge of outlet (min.) 12 30.5 Height to top of gas installation area 6 15.2 Depth to center of vent opening option 171⁄8 43.5 Depth of gas installation area 6 15.2 Depth of upper cabinet (recommended) 13 33.0 Depth from cutout to wall (min.) 213⁄32 6.1 Width of cutout 343⁄4 88.3 Depth of cutout 1915⁄16 50.6 Depth from cutout to front of
countertop (min.)
21⁄8 5.4
Recommended electrical access location Recommended gas supply line location Recommended venting location – see pages 3-4 for ducting information
SIDE VIEW TOP VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only. Do not make any cutouts based on this information. Refer to the Installation Guide before
8990dZw117