Width of assembled blower motor and plenum1429⁄6436.7
D
Height from blower motor to underside
E
of cooktop
Width from left side of cooktop base to
F
blower motor
Width from plenum to right side of cooktop base127⁄1631.6
A
C
J
I
H
G
Height of cooktop base33⁄49.5
H
Thickness of cooktop surface
I
Thickness of cooktop surface including knobs119⁄643.3
J
Depth of cooktop base2053⁄6452.9
K
Height from plenum to underside of cooktop1627⁄6441.7
L
1729⁄3245.5
121⁄324.2
1
⁄40.6
F
FRONT VIEW
B
SIDE VIEW
D
G
K
L
E
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8989dZw117
Page 2
JENN-AIR® DETAILED PLANNING DIMENSIONS
Side
Cabinet
J
K
Side
Cabinet
E*
J
F
D
e
A
B
B
v
C
I**
K
H
v
G
C
30" JX3™ ELECTRIC RADIANT DOWNDRAFT COOKTOP
JED3430G – 307⁄8" x 1729⁄32" x 23"
2 of 4
OPENING/CLEARANCE DIMENSIONS
A
E*
B
H
e
D
I**
FRONT VIEW
C
C
Side
Cabinet
J
G
v
v
K
MODEL #JED3430G
incm
Width of combustible area above
A
cooking surface (min.)
Width from cooktop to fixed wall
B
or other combustible material (min.)
Width to center of vent opening option (min.)
C
Width to outer edge of outlet (min.)
D
Height to bottom of uncovered wood or
E*
metal cabinet above cooking surface (min.)
Height to bottom of uncovered wood
F
F
B
or metal cabinet (min.)
Height to center of vent opening option
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet
is covered by not less than 1⁄4" (0.6 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
** Based on installation in a 24" (61.0 cm) deep by 341⁄2" (87.6 cm) high base
cabinet with a 11⁄2" (3.8 cm) thick counter top.
3076.2
21⁄26.4
811⁄3221.2
1025.4
3076.2
1845.7
1313⁄1635.1
1230.5
1333.0
11⁄23.8
287⁄873.3
211⁄853.7
25.1
ELECTRICAL REQUIREMENTS
220 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required. A dedicated
circuit is recommended.
VENTING REQUIREMENTS
This cooktop must be exhausted outdoors unless using the duct-free filter kit
(JDA7000WX). Refer to kit instructions for further information.
LOCATION REQUIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider than the cutout.
• A minimum clearance of 6" (15.2 cm) is recommended between the side of the
cooktop and side wall for maximum ventilation performance.
• A minimum clearance of 2" (5.1 cm) is recommended between the blower motor
and cabinet for proper cooling. A 6" (15.2 cm) clearance is recommended for
servicing access.
• An under counter built-in oven cannot be installed under this cooktop.
L
K
M
SIDE VIEWTOP VIEW – CUTOUT
N
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
8989dZw117
Page 3
JENN-AIR® DETAILED PLANNING DIMENSIONS
E
A
B
DUCT-FREE KIT
JDA7000WX – 175⁄8" x 103⁄8" x 71⁄2"
JX3™ DOWNDRAFT COOKTOPS WITH DUCT-FREE VENTILATION
The duct-free filter kit (JDA7000WX) is approved for use with JX3™ downdraft cooktop models
JGD3536G, JGD3430G, JED4536G, JED3536G, JED4430G and JED3430G. The kit filters the air
from the downdraft system and ventilates the conditioned air into the room through the toe kick
of the base cabinet. Do not ventilate the air from the downdraft system into the base cabinet,
base cabinet pedestal, crawl space, wall or attic.
PRODUCT DIMENSIONS
MODEL #JDA7000WX
Width of housing175⁄844.7
A
Height of housing103⁄826.5
B
Depth of housing71⁄219.0
C
Minimum height of toe kick 37.6
B
A
FRONT VIEW
D
Minimum depth to toe kick21⁄26.4
E
EXHAUST CUTOUT LOCATION
The cutout location in the toe kick area of the cabinet floor is
dependent upon the dimensions of the cooktop and base cabinet.
3 of 4
incm
C
Airflow
SIDE VIEW
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
D
Floor
8989dZw117
Page 4
JENN-AIR® DETAILED PLANNING DIMENSIONS
DOWNDRAFT COOKTOP DUCTING ARRANGEMENTS
The diagrams below show typical duct arrangements for downdraft cooktops. JX3™ downdraft cooktops
also offer a duct-free installation option. For more details, refer to page 3.
4 of 4
DUCTING CONFIGURATIONS
Roof jack
(8.3 cm x 25.4 cm) duct –
54' (16.5 m) max.
Transition elbow
REAR DUCTING IN WALL TO ROOF
1
3
⁄4" x 10"
DUCTING REQUIREMENTS
COOKTOPDUCT LENGTHDUCT SIZE
10' (3.0 m) or less*
Gas
Between 10' (3.0 m)
and 60' (18.3 m)
10' (3.0 m) or less**
Electric
Between 10' (3.0 m)
and 60' (18.3 m)
*Gas cooktops must use 5" (12.7 cm) diameter for runs of 10' (3.0 m) or less.
** May be used to vent straight out the back of the cooktop and directly through
the wall.
CALCULATING MAXIMUM DUCTING LENGTH
• Maximum ducting length is 60' (18.3 m).
• Each 90° elbow equals 5' (1.5 m) duct.
• Use no more than three 90° elbows.
• Flexible metal vent is not recommended.
• Do not install two elbows together.
NOTES:
• For ducting runs up to 30' (9.1 m), install cooktop as shipped.
• For ducting runs of 31' (9.4 m) to 60' (15.2 cm), remove the restricter
ring on the blower inlet housing.
• For altitudes above 4500' (1272.0 m), reduce recommended vent run
by 20% for best performance.
5" (12.7 cm)
diameter*
6" (15.2 cm)
diameter
31⁄4" x 10"
(8.3 cm x 25.4 cm)
5" (12.7 cm)
diameter**
6" (15.2 cm)
diameter
31⁄4" x 10"
(8.3 cm x 25.4 cm)
REAR DUCTING THROUGH WALL TO OUTSIDE
6" (15.2 cm) diameter duct –
511⁄2' (15.7 m) max.
31∕4" x 10"
SIDE DUCTING IN TOE KICK TO OUTSIDE
IMPORTANT: Dimensional specifications are provided for planning purposes only.
Do not make any cutouts based on this information. Refer to the Installation or Use & Care Guide
before selecting cabinetry, verifying electrical/gas connections, making cutouts or beginning installation.
All Jenn-Air® appliances are appropriately UL, CUL or CSA approved.
t
Transition elbow
6" (15.2 cm)
diameter wall cap
THROUGH FLOOR BETWEEN JOISTS TO OUTSIDE
6" (15.2 cm)
diameter elbow
5" (12.7 cm ) to 6" (15.2 cm)
diameter transition
8989dZw117
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.