JENN-AIR JEC8430BDW, JEC8536BDW, JEC8536BDB, JEC8536ADW, JEC8536ADS Installation Instructions

...
INSTALLATION
Radiant Cooktop
INSTRUCTIONS
Models JEC8430 & JEC8536
403 WEST FOURTH STREET, NORTH D NEWTON, IA 50208
IMPORTANT - SAVE FOR THE LOCAL ELECTRICAL INSPECTOR’S USE
IMPORTANT: Installation should be performed only by an authorized Jenn-Air Service Contractor or other qualified
installer. Read safety precautions in the Use & Care Manual before using this appliance.
(Dimensions shown in both inches and centimeters)
FOUR-ELEMENT RADIANT COOKTOPS
DIMENSIONS
A 29-1/16 + B20-3/8+ C 2-1/8 min. 5.4 D 4-1/8 min. clear 10.5 E 29-15/16 76.0 F 21-1/2 54.6 G3-3/4 9.5
1/16 74.0 + 0.2
1/16 51.9 + 0.2
NOTE: “D” is clearance needed for unit depth measure down from top of countertop. Typical for all units.
D
FIVE-ELEMENT RADIANT COOKTOPS
DIMENSIONS
E
A
F
A 34-9/16 + B20-3/8+ C 2-1/8 min. 5.4
G
B
D 4-1/8 min.clear 10.5 E 35-5/16 89.7 F 21-1/2 54.6 G3-3/4 9.5
C
1/16 87.9 + 0.2
1/16 51.9 + 0.2
IMPORTANT
CUTOUT DIMENSIONS
ARE CRITICAL
D
UNITS PROVIDED WITH 1/2² (1.3 cm) I.D. FLEXIBLE CABLE 48² (121.9 cm) LONG WITH 6² (15.2 cm) WIRE LEADS AT END, FURNISHED AND INSTALLED BY MANUFACTURER (CONNECT TO 240/120VOLT ELECTRICAL SERVICE).
INSTRUCTIONS TO INSTALLER:
S
Side Clearance - unit may be safely installed as near as 0² (0 cm) from a side wall if space limitations requires.
Notice To Installer: Leave these instructions with the appliance.
Notice To Consumer: Retain these instructions for future reference.
8101P503-60
(10-02-00)
Installing Cabinetry Over Your Cooktop
A= 30²²²² (76.2 cm) minimum clearance between the top of
the cooktop and the bottom of an unprotected wood or metal cabinet.
A= 24²²²² (60.96 cm) minimum when bottom of wood or
metal cabinet is protected by not less than 1/4² (0.635 cm). FLAME RETARDANT millboard covered with not less than no. 28 MSG sheet steel, 0.015² (0.038 cm) stainless steel, 0.024² (0.061 cm) aluminum or copper.
* To eliminate the risk of burns or
fire by reaching over heated surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5 inches beyond the bottom of the cabinets.
Important Installation Suggestions
1. Chamfer all exposed edges of decorative laminate to prevent damage from chipping.
2. Radius corners of cutout and file to insure smooth edges and prevent corner cracking.
3. Rough edges, inside corners which have not been rounded and forced fits can contribute to cracking of the countertop laminate.
4. Countertop must be supported within 3² (7.62 cm) of cutout.
CAUTION
Warranty is void on equipment installed other than as re­commended by manufacturer.
Electrical Wiring Information
The neutral of this unit is grounded to the frame through the solid copper grounding wire. If used on new branch-circuit installations (1996 NEC), mobile homes, recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor, untwist or disconnect the solid copper wire and connect the ground wire to ground in accordance with local code. Connect the white neutral to the service neutral. Connect all wires to the branch circuit with approved connectors. Use copper or aluminum wire. If aluminum wire is used, use connectors recognized for joining aluminum to copper.
Proper Electrical Supply
You must provide an adequate electrical supply system as required for your cooktop. All wire connections must be in accordance with local codes and properly insulated. Check with local utility for governing electrical codes and ordinances. In the absence of local electrical codes, the
National Electrical Code, NFPA No. 70, governing electric range installations must be followed. A copy of the National Electrical Code, NFPA No. 70, can be obtained by writing to:
National Fire Protection Association
Batterymarch Park
Quincy, Massachusetts 02269
A three-wire, single phase, A.C. 120/240 volt 60 cycle electrical system (properly circuit protected to meet Local Codes of NFPA No. 70) must be provided. Unit must be properly grounded in accordance with local wiring code. The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit. If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be created. It is advisable that the electrical wiring and hookup be accomplished by a competent electrician.
RECOMMENDED MINIMUM
K.W.RATING CIRCUIT PROTECTION WIRE SIZE
ON SERIAL PLATE IN AMPRES (AWG)
0-4.8 20 12
4.9 - 6.9 30 10
7.0 - 9.9 40 8
10.0 - 11.9 50 8
12.0 - 14.9 60 6
Notice T o Installer
Follow accompanying instruction carefully.
CAUTION
Never use a metal blade to pry knob off. If knob cannot be easily removed, tuck folds of a dish- towel under knob skirt and pull upward with steady, even pressure.
Preparation Of Countertop
The cutout in the countertop into which the appliance is to be installed should be prepared according to the cutout dimensions given on page 1 of these instructions.
CAUTION
Cutout dimensions are critical. Dimensions must be measured and cut accurately to within + to insure proper fit.
Installation Of Appliance
1. Remove the cooktop from the carton and place it upside down over two soft pads making sure control knobs do not interfere with any surface.
2. Provide cutout in countertop as required per page 1.
3. Place unit in the cutout.
4. Make electrical wire connection to unit. Consult local codes for proper power hook-up.
5. Test to insure control knobs operate all elements properly.