RV Radiant Cooktop Installation Instructions (Models JEC6288 & JEC6277)
30"
(76.2 cm)
2"
(5.08 cm)
minimum clearance
around cooktop to
cabinets or walls
5"
(12.7 cm)
18"
(45.72 cm)
22 3/4"
57.8 cm
27/8"
7.3 cm
31/2"
8.9 cm
21/2"
6.4 cm
13 3/4"
34.9 cm
12 3/8"
31.4 cm
21 3/8"
54.3 cm
IMPORTANT:
Installer: Leave installation instructions with the appliance.
• Follow the enclosed instructions to avoid countertop laminate damage.
Owner: Keep installation instructions for future reference.
• Save installation instructions for local electrical inspector’s use.
• Only qualified personnel should install or service this appliance.
• Read “Safety Instructions” in Use & Care Guide before using this appliance.
WARNING
Improper installation, adjustment, alteration, service,
maintenance or use of this appliance can result in serious
injury or property damage.
CAUTION
Warranty is void on equipment installed other than as
recommended by manufacturer.
1. UNPACK THE COOKTOP
Remove the cooktop from the carton and place it upside down
over two soft pads.
electrical rating
data plate
2. DETERMINE PLACEMENT
Determine where the unit will be installed to conform with all
safety codes and the guidelines below. Unit may be safely
installed as near as 2" (5.08 cm) from any cabinet or wall if space
limitations require.
Installing cabinetry over the cooktop:
1. To eliminate the risk of burns or fire by reaching over heated
surface units, cabinet storage space located above the
surface units should be avoided.
2. If cabinet storage is to be provided, the risk can be reduced
by installing a range hood that projects horizontally a
minimum of 5" (12.7 cm) beyond the bottom of the cabinets.
3. A clearance of 30" (76.2 cm) minimum is required between
the top of the cooktop and the bottom of an unprotected
wood or metal cabinet.
4. A clearance of 18" (45.72 cm) minimum is required when the
bottom of a wood or metal cabinet is protected by not less
than 1/4" (0.635 cm) FLAME RETARDANT millboard covered
with not less than No. 28 MSG sheet steel, 0.015" (0.28 cm)
stainless steel or 0.024" (0.061 cm) aluminum or copper.
CLEARANCE DIMENSIONS
3. PROVIDE CUTOUT
After determining correct cooktop position using the guidelines,
make the cutout in the counter top (Refer to illustrations).
CAUTION
Cutout dimensions are critical. Dimensions must be
measured and cut accurately to within ± 1/16" (.16 cm) to
insure proper fit.
Cutout:
1. Chamfer all exposed edges of decorative laminate to prevent
damage from chipping.
2. Radius corners of cutout and file to insure smooth edges and
prevent corner cracking.
3. Rough edges, inside corners which have not been rounded
and forced fits can contribute to cracking of the countertop
laminate.
4. Countertop must be supported within 3" (7.62 cm) of cutout.
NOTE: Countertop must be flat below the cooktop from the
cutout to the edge of the glass. 13/16" is the distance from
the edge of cooktop glass to the edge of the cutout.
TWO-ELEMENT RADIANT COOKTOP DIMENSIONS
NOTE: Figures may not be representative of actual unit
8101P722-60
4. INSTALL THE COOKTOP
• Place the unit in the cutout.
• Remove screws from bottom of cooktop and install brackets to
the bottom of the unit.
• Secure the cooktop to the countertop by tightening the adjusting
screws until finger tight.
DO NOT OVER-TIGHTEN.
CAUTION
Do not over-tighten the hold down adjusting screw. Damage
to the glass cooktop will occur if excessive pressure is used.
Secure the unit to the countertop using only the hold down
bracket and adjusting screw provided, do not use any other
means to secure the unit.
NOTE: Foam tape is supplied with the unit. If desired, apply
the foam tape around the bottom outside edge of the glass
before installing unit.
foam tape
5. MAKE ELECTRICAL
CONNECTION
• Check that the power supply is OFF.
• Make electrical connection to the unit.
• Consult local codes for proper power hookup.
• The supply voltage may be varied according to the rating plate
(located on the bottom of the unit).
CAUTION
Do not use the junction box for additional wiring connections.
Do not remove the center terminal ground wire from the unit.
WARNING
Turn off power supply when making electrical connections.
Model JEC6288 (6277)
A two-wire, single phase, A.C. 120/240 volt (120 volt for Model
AEZ8581) 60 cycle electrical system (properly circuit protected to
meet Local Codes of ANSI/NFPA No. 70) must be provided. Unit
must be properly grounded in accordance with local wiring code.
The supply ground wire should be connected to the green
grounding screw on the power block grounding tab. There is no
neutral wire on the AEZ8590. Recommended minimum wire size
is 12 AWG.
Model JEC6288
(240 Volt, 13.3 Amps)
Model JEC6277
(120 Volt, 20 Amps)
6. TEST THE UNIT
• Restore the power supply and test to insure the touch controls
operate all elements properly.
You must provide an adequate electrical supply system as
required for your cooktop. All wire connections must be in
accordance with local codes and properly insulated. Check with
local utility for governing electrical codes and ordinances. In the
absence of local electrical codes, the National Electrical Code
(NEC), ANSI/NFPA No. 70-latest edition, governing electric range
installations must be followed. A copy of the National Electrical
Code, ANSI/NFPA No. 70-latest edition can be obtained by
writing to:
National Fire Protection Association
Batterymarch Park
Quincy, MA 02269
IMPORTANT: The installation and use of a cooktop in a Marine
application must conform to the American Boat and Yacht Council
Standard ABYC A-3 (Galley Stoves).
The wiring must conform to ABYC E-11 (AC & DC Electrical
Systems).
IMPORTANT: The installation of a cooktop designed for mobile
home installation must conform with the Manufactured Home
Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24 HUD, Part 280) or, when such standard is not
applicable, the Standard for Manufactured Home Installations
ANSI A225.1/NFPA501A, or with local codes. In Canada the
range must be installed in accordance with the current CSA
Standard C22.1 - Canadian Electrical Code Part 1.
adjusting screws
Red
Ground
Black
This unit is supplied with an electrical junction box on a 48" long,
1/2" (1.3 cm) I.D. flexible conduit. The junction box is designed to
be attached to a solid mounting surface in the area below the
cooktop. Connect all supply wires to the power block with
approved connectors. Bare wires can be attached using the
supplied bare wire adapter lugs. All connections should be
torqued to 20 in-lb.
White/Neutral
Ground
Black
MMaayyttaagg •• 440033 WWeesstt FFoouurrtthh SSttrreeeett NNoorrtthh •• PP.. OO.. BBooxx 3399 •• NNeewwttoonn,, IIoowwaa 5500220088