JENN-AIR°
20" (50.8 CM), 30" (76.2 CM) AND 45" (114.3 CM)
ELECTRICDOWNDRAFTCOOKTOP INSTALLATION
INSTRUCTIONS
INSTRL)CTIONSD'INSTALLATION DE LATABLEDE
CUISSON ELECTRIQUEAVEC ASPIRATION PARLEBASDE
20" (50,8 CM), 30" (76,2 CM) ET45" (114,3 CM)
TableofContents/Tabledes mati_res
COOKTOP SAFETY ........................................................................ 1
INSTALLATION REQUIREMENTS ................................................ 2
Tools and Parts ............................................................................ 2
Location Requirements ................................................................ 2
Venting Requirements .................................................................. 4
Venting Methods .......................................................................... 5
Electrical Requirements .............................................................. 7
INSTALLATION INSTRUCTIONS .................................................. 8
Prepare Cooktop .......................................................................... 8
Rotate Blower - Optional .............................................................. 8
Install Cooktop ............................................................................. 9
Make Electrical Connection ....................................................... 10
Complete Installation .................................................................. 11
SleCURITle DE LA TABLE DE CUISSON ................................. 12
EXIGENCES D'INSTALLATION ................................................ 12
Outillage et pieces ................................................................... 12
Exigences d'emplacement ...................................................... 12
Exigences concernant I'evacuation ........................................ 16
Methodes d'evacuation ........................................................... 17
Specifications electriques ....................................................... 19
INSTRUCTIONS D'INSTALLATION ......................................... 20
Preparation de la table de cuisson ......................................... 20
Rotation du ventilateur - facultative ........................................ 20
Installation de latable de cuisson ........................................... 21
Raccordement electrique ........................................................ 22
Achever I'installation ............................................................... 23
COOKTOP SAFETY
Your safety and the safety of others are very important.
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
iMPORTANT:
Save for local electrical inspector's use.
iMPORTANT :
A conserver pour consultation par I'inspecteur local des installations 61ectriques.
W10421939A
INSTALLATIONREQUIREMENTS
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
• Tape measure
• Flat-blade screwdriver
• Phillips head screwdriver
• Drill
• Level
• 6" socket extension
Parts supplied
• Vent grille
• Grease filter
• Grill cartridge
• Grease container(s)
• Hold-down straps (4)
• Clamping screws (4)
Parts needed
• A UL listed or CSA approved strain relief for 7/8"(2.2 cm)
knockout.
• A UL listed or CSA approved conduit connector for
1/2"(1.3 cm) trade-size metal-clad conduit
• UL listed wire connectors
• Metal ducting
• Jenn-Air wall cap
Jenn-AiP_6 '' (15.2 cm) Round Surface Wall Cap Damper
Order Part Number A406
Jenn-AiP _31¼''x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper
Order Part Number A403
To order, see the "Assistance or Service" section of the Use
and Care Guide.
• Vent clamps
Check local codes. Check existing electrical supply. See
"Electrical Requirements" section.
It is recommended that all electrical connections be made by a
licensed, qualified electrical installer.
IMPORTANT: Observe all governing codes and ordinances.
When installing cooktop, use minimum dimensions given.
• To eliminate the risk of burns or fire by reaching over the
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
• Use the countertop opening dimensions that are given with
these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
• Marker or pencil
• Pliers
• W' drill bit
• Jigsaw
• Ratchet with 3/8"socket
• Grounded electrical supply is required. See "Electrical
Requirements" section.
• If cabinet has drawers, drawers will need to be removed and
drawer fronts installed on front of cabinet.
IMPORTANT: An under-counter built-in oven cannot be installed
under this product.
Product Dimensions
20" (50.8 cm) Single Cartridge Cooktop
/
\\\
\\
\\\\\\
/ .......<// ...................C
..... _ D
\\
A. 19_" (48.9 cm)
B. 21%" (53.6 cm)
C.Grease container
D.Blower
A
B
f C*
G
A. Side clearance - See WOTE.
B. 4%" (12.0 cm)
C. 6¼" (15.9 cm)
D. Grease container
E.2" (5.0 cm) min. to cabinet,
6" (15.2 cm) recommended to motor service
F. 12V2" (31.8 cm)
G. 17Y2" (44.5 cm)
*NOTE: Grills installed near a side wall must allow a minimum
clearance of 6" (15.2 cm) between cooktop and sidewall for
maximum performance. Minimum clearance of 1" (2.5 cm) is
required to sidewalls and 3A" (1.9 cm) to rear wall.
*A minimum clearance of 6V4" (15.9 cm) is recommended for
removal of the grease filter(s). Installed dimension for the grease
filter(s) is 51/2'' (14.0 cm).
**A minimum clearance of 2" (5.1 cm) is required between the
blower motor and cabinet for proper cooling. A clearance of
6" (15.2 cm) is recommended to allow for blower motor service.
2
30" (76.2 cm) Double Cartridge Cooktop
45" (114.3 cm) Triple Cartridge Cooktop
D
A. 3015A6'' (78.6 cm)
B. 211/s'' (53.6 cm)
C. Grease container
D. Blower
A
B
C _
f
f
HjG
F
A. Side clearance - See *NOTE.
B. 43/4'' (12.0 cm)
C. 6¼" (15.9 cm)
D. Grease containers
E. 2" (5.0 cm) min. to cabinet,
6" (15.2 cm) recommended to motor service
*NOTE: Grills installed near a side wall must allow a minimum
clearance of 6" (15.2 cm) between cooktop and sidewall for
maximum performance. Minimum clearance of 1" (2.5 cm) is
required to sidewalls and 3A" (1.9 cm) to rear wall.
*A minimum clearance of 61/4'' (15.9 cm) is recommended for
removal of the grease filter(s). Installed dimension for the grease
filter(s) is 51/2'' (14.0 cm).
**A minimum clearance of 2" (5.1 cm) is required between the
blower motor and cabinet for proper cooling. A clearance of
6" (15.2 cm) is recommended to allow for blower motor service.
E 12'/2"(31.8 cm)
G. 117/16'' (29.1 cm)
H. 1T/2"(44.5 cm)
A. 46¼" (117.5 cm)
B. 211/8'' (53.6 cm)
C. Grease container
D. Blower
A
I
T
H
o h l I D...........
"-- G ----_ .D
l
I
g
f C*
L F
A. Side clearance - See WOTE.
B. 43/4'' (12.0 cm)
C. 6¼" (15.9 cm)
D. Grease containers
E. 2" (5.0 cm) min. to cabinet,
6" (15.2 cm) recommended to motor service
*NOTE: Grills installed near a side wall must allow a minimum
clearance of 6" (15.2 cm) between cooktop and sidewall for
maximum performance. Minimum clearance of 1" (2.5 cm) is
required to sidewalls and 3A" (1.9 cm) to rear wall.
*A minimum clearance of 61/4'' (15.9 cm) is recommended for
removal of the grease containers. Installed dimension for the
grease containers is 51/2"(14.0 cm).
**A minimum clearance of 2" (5.1 cm) is required between the
blower motor and cabinet for proper cooling. A clearance of
6" (15.2 cm) is recommended to allow for blower motor service.
E 301/s'' (76.5 cm)
G. 117/16'' (29.1 cm)
H. 1T/2" (44.5 cm)
f
Cabinet Dimensions
Cutout Dimensions
A------t
G
A. 24" (61.0 cm) on 20" (50.8 cm) single cartridge models
30" (76.2 cm) on 30" (76.2 cm) double cartridge models
45" (114.3 cm) on 45" (114.3 cm) triple cartridge models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform
and bottom of uncovered wood or metal cabinet (24" [61 cm]
minimum clearance if bottom of wood or metal cabinet is covered
by not less than 1/4"[0.6 cm] flame retardant millboard covered with
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E.2%" (5.4 cm) min.
F. 20%6" (58.2 cm)
G. 18" (45. 7 cm) minimum clearance from upper cabinet to countertop
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of
countertop
I.Junction box or outlet; 10" (25.4 cm) from right-hand side of cabinet
J. 1811/16'' (47.5 cm) on 20" (50.8 cm) single cartridge models
307A6''(77.3 cm) on 30" (76.2 cm) double cartridge models
413½='' (106.6 cm) on 45" (114.3 cm) triple cartridge models
K. Side clearance - See *NOTE.
L. 2" (5.1 cm) minimum clearance between back wall and countertop
cutout
*NOTE: Grills installed near a side wall must allow a minimum
clearance of 6" (15.2 cm) between cooktop and sidewall for
maximum performance. Minimum clearance of 1" (2.5 cm) is
required to sidewalls and 3A" (1.9 cm) to rear wall.
NOTES: After making the countertop cutout, some installations
may require notching down the base cabinet side walls to clear
the cooktop base. To avoid this modification, use a base cabinet
with sidewalls wider than the cutout.
Where possible, a 6" (15.2 cm) clearance is recommended for
motor blower service. A minimum clearance of 1" (2.5 cm) is
recommended to the sidewalls and a 3/4"(1.9 cm) clearance is
recommended to the rear wall.
A minimum clearance of 2" (5.1 cm) is recommended
between the motor/blower and cabinet for proper cooling.
A minimum clearance of 61/4'' (15.9 cm) is recommended for
removal of the grease container(s). Installed dimension for the
grease containers is 51/2"(14.0 cm).
For grills installed near a sidewall, a minimum clearance of
6" (15.2 cm) is recommended between the cooktop and
sidewall for maximum performance.
A
I
A. 1811/16'' + 1/16"(47.5 cm +_0.2 cm) on 20" (50.8 cm) single cartridge
models
307/16'' + 1A6"(77.3 cm +_0.2 cm) on 30" (76.2 cm) double cartridge
models
413½='' + 1A6"(106.6 cm +_0.2 cm) on 45" (114.3 cm) triple
cartridge models
B. 209/16'' +_1/16"(52.2 cm +_0.2 cm) maximum on all models
C. 6%6" (16.0 cm) on 20" (50.8 cm) single cartridge models
173/4"(45.1 cm) on 30" (76.2 cm) double cartridge models
173/4"(45.1 cm) on 45" (114.3 cm) triple cartridge models
D. 147/16'' (36. 7cm) on all models
E.2%" (5.4 cm) minimum space to front edge of cooktop
F. Minimum cabinet width:
21" (53.3 cm) on 20" (50.8 cm) single cartridge models
33" (83.8 cm) on 30" (76.2 cm) double cartridge models
45" (114.3 cm) on 45" (114.3 cm) triple cartridge models
G. Floor exhaust option
H. 6%" (15.6 cm) for 6" vent system
I. 6%6" (16.0 cm) on 20" (50.8 cm) single cartridge models
173/4"(45.1 cm) on 30" (76.2 cm) double cartridge models
173/4"(45.1 cm) on 45" (114.3 cm) triple cartridge models
J. 8" (20.3 cm) from center of the vent hole in the cabinet to the top
surface of the countertop, on all models
K. Wall exhaust option
Do not terminate the vent system in an attic or other enclosed
area.
• Use a Jenn-AiP vent cap.
• Vent system must terminate to the outside.
• Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is
recommended. For best performance, do not use plastic or
metal foil vent.
Before making cutouts, make sure there is proper clearance
within the wall or floor for the exhaust vent.
Do not cut a joist or stud unless absolutely necessary. If a
joist or stud must be cut, then a supporting frame must be
constructed.
The size of the vent should be uniform.
The vent system must have a damper. If roof or wall cap has a
damper, do not use damper supplied with the range hood.
• Useonlya6"(15.2cm)roundmetalventora31/4"x10''
(8.3x25.4cm)rectangularmetalventexceptforasfollows:
• Forelectricmodels,5"(12.7cm)diameterroundmetal
ventmaybeusedforventingstraightoutthebackofthe
cooktopanddirectlythroughthewallforaductlengthof
10ft(3.0m)feetorless.
• Forgasmodels,5"(12.7cm)diameterroundmetalvent
mustbeusediftheductlengthis10ft(3.0m)feetorless.
• Donotuse5"(12.7cm)elbowsexceptina5"(12.7cm)
system.Instead,usea5"(12.7cm)to6"(15.2cm)elbowora
5"(12.7cm)to31/4"x10"(8.3x25.4cm)elbowtransition.
• Useventclampstosealalljointsintheventsystem.
• Usecaulkingtosealexteriorwallorroofopeningaroundthe
cap.
• Determinewhichventingmethodisbestforyourapplication.
For Best Performance:
• Use 26-gauge minimum galvanized or 25-gauge minimum
aluminum metal vent. Poor quality pipe fittings can reduce
airflow. Flexible metal vent is not recommended.
NOTE: Local codes may require a heavier gauge material.
• Metal duct may be reduced to 30-gauge galvanized steel or
26-gauge aluminized steel if allowed by local codes. This
reduction is based on information in the International
Residential Codes Section M1601.1 (2006 edition).
• Do not install 2 elbows together.
• Use no more than three 90° elbows.
• If an elbow is used, install it as far away as possible from the
hood's vent motor exhaust opening.
• Make sure there is a minimum of 18" (45.7 cm) of straight
vent between the elbows if more than one elbow is used.
• Elbows too close together can cause excess turbulence that
reduces airflow.
• Do not use a 5" (12.7 cm) elbow in a6" (15.2 cm) or 31/4"x 10''
(8.3 x 25.4 cm) system.
• Do not reduce to a 5" (12.7 cm) system after using
6" (15.2 cm) or 31/4'' x 10" (8.3 x 25.4 cm) fittings.
• Avoid forming handmade crimps. Handmade crimps may
restrict airflow.
• Use a Jenn-Air ®vent cap for proper performance. If an
alternate wall or roof cap is used, be certain the cap size is
not reduced and that it has a backdraft damper.
The length of vent system and number of elbows should be kept
to a minimum to provide efficient performance.
The maximum equivalent length of the vent system is 60 ft
(18.3 m). For altitudes above 4,500 ft (1272 m), reduce
recommended vent run by 20% for best performance.
Cold Weather Installations
An additional back draft damper should be installed to minimize
backward cold air flow and a thermal break installed to minimize
conduction of outside temperatures as part of the vent system.
The damper should be on the cold air side of the thermal break.
Makeup Air
Local building codes may require the use of makeup air systems
when using ventilation systems greater than specified CFM of air
movement. The specified CFM varies from locale to locale.
Consult your HVAC professional for specific requirements in your
area.
Common venting methods are shown for a counter-mounted
downdraft cooktop. The cooktop may be vented through the wall
or floor.
Option 1 - Roof Venting Option 2 - Wall Venting
A. 6" (15.2 cm) round roof
venting
B. Roof cap
Option 3 - Venting Between
Floor Joist
A. 6" (15.2 cm) round wall
venting
B. Wall cap
Option 4 - Venting behind
Cabinet Kick Plate
I
= " = "
A. Wall cap
B. 6" (15.2 cm) round wall
venting
A. Wall cap
B. 6" (15.2 cm) round wall
venting
Concrete Slab Installations -
Exhaust Through Window Well
Calculating Vent System Length
B D
.............Ji E
A. Wall cap
B. 12" (30.5 cm) minimum
C. Concrete slab
D. 6" (15.2 cm) round PVC sewer pipe
E. 5" to 6" (12.7cm to 15.2 cm) transition
F. 6" (15.2 cm) round metal duct
G. 6" (15.2 cm) round PVC coupling
H. 6" (15.2 cm) round PVC sewer pipe
I. 6" (15.2 cm) round 90 ° PVC sewer pipe elbow
J. Tightly pack gravel or sand completely around pipe.
K. 42 ft (12.8 m) max.
L. 6" (15.2 cm) round PVC coupling
M. 6" (15.2 cm) minimum
N. Window well
Concrete Slab Installations - Exhaust Through Wall
B
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the system.
Vent Piece 6" (15.2 cm) Round
45 ° elbow 2.5 ft
(0.8m)
90 ° elbow 5.0 ft
(1.5m)
6" (15.2 cm) 0.0 ft
wall cap (0.0 m)
31/4"x 10" (8.3 cm x 25.4 cm) 4.5 ft
to 6" (15.2 cm) transition (1.4 m)
6" (15.2 cm) to 31/4'' x 10" 1 ft
(8.3 cm x 25.4 cm) transition (0.3 m)
A
L
O
M
A. Wall cap
B. 6" (15.2 cm) round metal vent
C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe
E. 5" to 6" (12.7cm to 15.2 cm) transition
F. 6" (15.2 cm) round metal duct
G. 6" (15.2 cm) round
H. Concrete slab
I. 6" (15.2 cm) round
J. 6" (15.2 cm) round
K. Tightly pack gravel
L. 3O ft (9.1 m) max.
M. 6" (15.2 cm) round
N. 6" (15.2 cm) round PVC coupling
O. 12" (30.5 cm) minimum
__ E
_4-_,_-_ _,,_ H
PVC coupling
PVC sewer pipe
90 ° PVC sewer pipe elbow
or sand completely around pipe.
90 ° PVC sewer pipe elbow
_:" ............F
31/4"x 10" (8.3 cm x 25.4 cm) 9.0 ft
to 6" (15.2 cm) 90 ° elbow (2.7 m)
transition
6" (15.2 cm) to 31/4"x 10'' 5.Oft
(8.3 cm x 25.4 cm) 90° elbow (1.5 m)
transition
K
31/4'' x 10" (8.3 cm x 25.4 cm) 5.0 ft
90° elbow (1.5 m)
31/4"x 10" (8.3 cm x 25.4 cm) 12.0 ft
flat elbow (3.7 m)
31/4'' x 10" (8.3 cm x 25.4 cm) 0.0 ft
wall cap (0.0 m)
5" to 6" (12.7 cm to 15.2 cm) 1 ft
transition (0.3 m)
6
Example vent system
90 ° embow
6 ft (1.8 rn)
(
1- 90° elbow = 5 ft (1.5 m)
8 ft (2.4 m) straight = 8 ft (2.4 m)
1 - wall cap = 0 ft (0 m)
System length = 13 ft (3.9 m)
NOTE: Flexible vent is not recommended. Flexible vent creates
back pressure and air turbulence that greatly reduce
performance.
wall cap
7. Reattach the four acorn nuts to secure the blower motor
assembly back to the blower exhaust scroll.
Determine Range Blower Setting
This cooktop is equipped with a dual range blower. It is shipped
from the factory in the low range for most installations. If the
equivalent duct length exceeds 30 ft (9.1 m), it must be converted
to high range. Do not convert the blower to high range for shorter
lengths; this will cause excessive noise and conditioned air loss.
Convert blower before installing into countertop if necessary.
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
To Convert to High Range:
1. Using 2 or more people, place cooktop on floor with front
edge and plenum down.
2. Remove the four acorn nuts (A) that attach the blower motor
assembly to the blower exhaust scroll.
3. Remove the blower motor assembly (B) from the blower
exhaust scroll (E).
4. Slowly reach in the blower exhaust scroll opening and
remove the snap ring (C).
5. Gently remove the restrictor ring (D).
6. Place the motor assembly back on the studs of the blower
exhaust scroll.
A. Acorn nuts (4)
B. Blower motor assembly
C. Snap ring
D. Restrictor ring
E. Blower exhaust scroll
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrical installer determine that
the ground path and wire gauge are in accordance with local
codes.
Check with a qualified electrical installer if you are not sure the
cooktop is properly grounded.
Make sure that the electrical connection and wire size are
adequate and in conformance with the National Electrical Code,
ANSI/NFPA 70-latest edition or CSA Standards C22.1-94,
Canadian Electrical Code, Part 1 and C22.2 No. O-M91-1atest
edition, and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
Before You Make the Electrical Connection:
To properly installyour cooktop, you must determine the type of
electrical connection you will be using and follow the instructions
provided for it here.
• A 4-wire or 3-wire, single phase, 120/240 volt, 60 Hz., AC
only electrical supply is required on a separate, 40-amp
circuit (30" [76.2 cm] models), 20-amp circuit (20" [50.8 cm]
models) or 60-amp circuit (45" [114.3 cm] models), fused on
both sides of the line.
The cooktop should be connected directly to the junction box
in the cabinet through the flexible metal conduit. The flexible,
armored cable extending from the fuse box or circuit breaker
box should be connected directly to the cooktop wiring box.
Locate the junction box in the cabinet to allow as much slack
as possible between the junction box and the cooktop so that
the cooktop can be moved if servicing becomes necessary in
the future.
A UL listed or CSA approved conduit connector must be
provided at each end of the power supply cable (at the
cooktop wiring box and at the junction box in the cabinet).
• If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
4. Remove the removable grease filter by lifting the filter out.
5. Using 2 or more people, remove the cooktop from the carton.
6. Use foam end caps from the packaging as a work surface for
the floor or countertop.
7. Using 2 or more people, place the cooktop on the foam end
caps.
8. Avoid placing the cooktop face down on the control knobs.
REMEMBER: An undercounter built-in oven cannot be
installed under this cooktop.
IMPORTANT: The following additional steps must be performed
if the product is being installed in peninsula or island cabinetry.
The blower exhaust scroll is shipped from the factory set to
exhaust straight out the back of the cabinet through an exterior
wall.
INSTALLATIONINSTRUCTIONS
_ _]_,_E_ _/__ _......_/_ '¸
Decide on the final location for the cooktop.
Excessive Weight Hazard
Use two or more people to move and install cooktop.
Failure to do so can result in back or other injury.
1. Open product as instructed on product packaging.
2. Remove shipping materials and tape from cooktop.
3. Remove vent grille and grates if present.
B C
A
/
B
E
A. Blower exhaust scroll
B. Plenum
C. Blower motor
D. 10-32 machine nuts (4)
E. Motor mounting plate
To rotate blower:
1.
Locate the four plastic plugs in the plenum bypass.
2.
Use the pliers to remove the plastic plugs.
IMPORTANT: Do not throw away the plastic plugs. The
plastic plugs must be reinstalled after the blower exhaust
scroll has been rotated.
A ......................._ E
B
C .......................i/
D
A. Blower motor
B.Exhaust scroll
C. Plenum
D. Blower bypass
E.Plastic plugs (4)
A. Vent grille (already removed)
B. Removable grease filter
C. Radiant element cartridge