Overall width:
Overall depth:
Distance from top of counter to bottom of unit:
Cut-Out width:
Cut-Out depth:
45 3/4" 20 15/16"
46 13/16" 21 9/16" see below
Min. spacing from cooktop edge to nearest
vertical combustible wall to the RIGHT:
6"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the LEFT:
6"
Min. spacing from cooktop edge to nearest
vertical combustible wall to the REAR:
Minimum spacing to front edge of counter:
0" 1 7/8"
Minimum distance between cooktop
and cabinet directly above:
Minimum width of cabinet directly above:
30" 48"
Maximum depth of cabinets directly
above and adjacent:
13"
Minimum distance between countertop
and adjacent cabinet above:
18"
• Additional Information •
• Cabinetry over cooktop : 30' minimum clearance
between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardant millboard covered with not less than no. 28 MSG sheet steel, 0.015" stainless steel, 0.024" aluminum or copper.
• To eliminate the hazard of reaching over heated
surface units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to be provided, the hazard can be reduced by installing a range hood that projects horizontally a minimum of 5" beyond the bottom of the cabinets.
• Countertop must be supported within 3" of cutout.
• Radius corners of cutout and file to insure smooth
edges and prevent corner cracking (1/4" radius).
• Blower can be swiveled 90°.
See page 2-3 for additional information
Side View (not to scale)
20 15/16"
18"
15 5/8"
Minimum
clearance
required
see below
45 3/4"
48"
30"
Grease containers
46 13/16"
21 9/16"
Overall Dimensions
Top View (not to scale)
Cut-Out Dimensions
Countertop View
(not to scale)
Cabinet Requirements
Wall View
(not to scale)
Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 6" (see solid areas).
3"
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of deter­mining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.
321
Provide 2" min. cabinet clearance to motor for cooling purpose. 6" recomended for servicing.
Front View of Cooktop and
Attached Blower
BN158 • A321B149C150 • 31469 • 002906 • 135144 • 12326
28 11/16"14"
(not to scale)
www.dexpress.com
DIMENSION EXPRESS
Fax on Demand (775) 833-3600
Additional Information:
• Electric supply: 120/240 or 120/208 VAC, 60Hz (Load 52.3 amps @
120/240VAC). 55 amp grounded circuit is required, Power cord is NOT supplied.
• Duct requirements: See page 3 for ducting information and below for
location.
• Under counter access must be provided to remove and empty
grease container(s).
• Accepts Jenn-Air Designer Line Cartridges.
• C316 : Black.
• C316W : White.
Duct locations
(not to scale)
Page 2
This Data Sheet Includes Information On
Jenn-Air
• Product Model Number (s): •
Designer Line 48" Convertible Cooktops:
C316 and C316W
7 9/16"
13"
9 3/8"
Top of counter to centerline of back duct location: 13"
Left edge of cutout to centerline of back and bottom duct locations: 9 3/8"
Front edge of cutout to centerline of bottom duct location: 7 9/16"
Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2000.
• NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets.