• Results can be saved via internal memory or external USB
memory stick
• Report generation soware OFS-355
JDSU’s Sm a r t optical handhelds go beyond the basics
The JDSU OCC-56 is a handheld, battery-operated DWDM Channel Checker that is ideal for field
service groups tasked with the installation, maintenance, and upgrades of DWDM systems. The
OCC-56 scans the DWDM system and automatically records all channels with the wavelength/
frequency and the related power level. The information can be displayed in a graphical spectrum
format, or in a table of results so that users can easily check the performance of each and every
channel.
The S DWDM Channel Checker is available in two different versions
OCC-56C covers all ITU-T frequencies from 1528 nm to 1564 nm based on a 50 GHz grid.
OCC-56L is the complementary channel checker to address applications in the L-band from
1570 nm to 1609 nm.
WEBSITE: www.jdsu.com
Graphical display
Cursor position indicates channel shown in the upper section of
the display.
Tabular display
Channel number, frequency (wavelength) with the relevant power
level is listed in a compact format.
Optimization of measurements by the definition of customized
wavelength grids. Up to 10 sets of parameters can be saved on the
OCC-56.
2
OCC-56C/56L Smart OPTICAL DWDM CHANNEL CHECKER
Dust cap to protect the optical interface
OCK-10 Optical Connector Cleaning Kit (accessory)
OIM-400 Fiber Microscope (accessory)
Optical adapters (BN 2150) for signal input
Shock-proof design
Display (128 x 64 dots) shows
up to three results simultaneously
Display backlight
Menu-oriented operation for
simple use
Client USB connection
Power-on, auto power-off
(after 20 min)
Worldwide compatible AC adapter/charger
(SNT-121A)
Battery compartment
4x AA sized dry/rechargeable
batteries
3
OCC-56C/56L Smart OPTICAL DWDM CHANNEL CHECKER
Specifications
OCC-56COCC-56L
Wavelength range1528 nm to 1564 nm1570 nm to 1609 nm
Wavelength accuracytyp. ± 3.3 GHz
Channel spacing50 GHz / 100 GHz / 200 GHz
Channel power range<-70 to +10 dBm
Absolute accuracy
Readout resolution± 0.1 dB
Filter selectivity
Optical bandwidth 3 dB
Measurement time~ 120 s (full span sweep) typ.
Optical interfaceUniversal PC (FC/SC/DIN...)
Max. composite power+22 dBm
Return loss>35 dB
Graphical display
Trace
Tablech-no, wavelength, power
FunctionsZoom, marker
Sweep modeSingle, continuous
Remote controlvia USB interface
(1)
For input levels -60 dBm to +5 dBm
(2)
23°C ± 5°C
(1), (2)
< ± 1 dB
35 GHz (0.28 nm) typ.
Bar graph, 50 GHz/pixel
Display
Graphical display, resolution of 128 × 64 dots, displays up to four laser status screens
Backlight function switchable via a separate key
Optical interface
Optical connector interchangeable adapter from BN 2150/00.xx range
Power supply
Four dry batteries Mignon/AA, 1.5 V or NiMH rechargeable cells Mignon/AA, 1.2 V
Operating time from dry batteries typ. 7 h
Power saving
The instrument switches off automatically after ~20 min (function can be disabled)
AC line operation via separate AC adapter
Integrated fast battery charging function (2 hours)
Electromagnetic compatibility
Corresponds to IEC 61326 (CE conformance)
Calibration
Suggested calibration interval 3 years
Temperature
Opreration −10°C to +55°C
Storage −40°C to +70°C
Dimensions and weight
W × H × D approximately 95 × 60 × 195 mm (3.74 × 2.36 × 7.68 in)
Weight approximately 500 g (1.1 lb)