NORTH AMERICA
TEL
: 1 866 228 3762
FAX : +1 301 353 9216
All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no
responsibility is assumed for any inaccuracies. The user assumes all risks and liability whatsoever in connection with
the use of a product or its application. JDSU reserves the right to change at any time without notice the design,
specifications, function, fit or form of its products described herein, including withdrawal at any time of a product
offered for sale herein. JDSU makes no representations that the products herein are free from any intellectual
property claims of others. Please contact JDSU for more information. JDSU and the JDSU logo are trademarks of
JDS Uniphase Corporation. Other trademarks are the property of their respective holders. ©2007 JDS Uniphase
Corporation. All rights reserved. 10143169 501 0707 CLI14501750.DS.CAB.TM.AE
Test & Measurement Regional Sales
LATIN AMERICA
TEL
: +55 11 5503 3800
FAX : +55 11 5505 1598
ASIA PACIFIC
TEL
: +852 2892 0990
FAX : +852 2892 0770
EMEA
TEL
: +49 7121 86 2222
FAX : +49 7121 86 1222
www.jdsu.com/test
CLI-1450/CLI-1750
Technical Specifications
Frequency
Range CLI-1450 45 to 559 MHz
45 to 890 MHz option
5 to 45 MHz sub-band option
Range CLI-1750 5 to 890 MHz
Accuracy 10 ppm @ 25°C (77°F); 20 ppm over temp
Tuning Resolution 25 kHz
Level Measurement
Range -20 to +50 dBmV
Resolution 0.1 dB
Accuracy ±0.75 dB Flatness,
±0.75 dB Linearity @ 25°C (77°F)
Digital Average Power (optional) ± 2.0 dB (typical)
Scan Mode
Number of Channels 120
Scan Rate Approximately 6 carriers/second
Leakage Mode
Level Measurement
Input Sensitivity (with LD-3 dipole or VMA-3 mag mount)
Video Detection From 1 µV with LT1000
Leakage Tagger activated (121 to 133.2625 MHz)
CW Detection From 0.5 µV typical with LT1000
Leakage Tagger activated (121 to 133.2625 MHz
Measurement From 1.4 µV (115 to 140 MHz)
Range 0.5 to 2,000 µV (at input connector)
Accuracy
Measurement ±1.5 dB @ 25°C (77°F)
Find & Fi x ±2.25 dB @ 25°C (77°F)
Tuning Carrier
Frequency Range 115 to 140 MHz range (Video)
Accuracy 10 ppm @ 25°C (77°F); 20 ppm over temp
Resolution 25 kHz
General
Dimensions 4.25" (W) x 10" (H) x 2.5" (D)
Weight 1.3 kg (2.9 lb.)
Operating
Temp. Range -10 to +50°C (14 to 122°F);
±3 dB drift, -10 to +50°C
Water Resistance Meets or exceeds MIL-STD-810D
(Method 506.2)
Power
Battery Life 2.25 hours continuous (backlight off)
2.25 hours continuous (backlight off) in leakage mode
replaceable battery cartridge
Charge Time 16 hour charge with unit “off”
Options and Accessories
Model CLI-1450 / CLI-1750
Includes a battery cartridge, one charger/AC adapter,a near
field probe antenna,and an operating manual.
LT1000
Leakage Tagger Differentiates leaks in overbuilt systems,
increases detection range,and limits false alarms
DS-1 Vehicle mount “Docking Station” for quick antenna
and auxiliary power connection in vehicle
DS-ARM Adjustable arm mount for docking station
to enable viewing of display from driver’s seat
VMA-3 Magnetic vehicle mount 1/4l whip antenna
LD-3 Dipole antenna with telescoping fiberglass
extension pole,fully extendible to the FCC
measurement distance of 10 feet (3 meters)
MBC-6 6-bay battery cartridge charger (U.S. only)
MBC-4 4-bay baterry cartridge charger (CE compliant)
MSCLI Printer Portable serial thermal fusion printer kit
StealthWare Data management and analysis software
(includes 1019-00-0469, CLI to PC cable)
1019-00-0476 Durable padded carrying case
1019-00-0479 Battery cartridge
3010-16-0025 Near field probe antenna
4010-00-0119 Charger/Adapter,120VAC to 12VDC
1019-00-0554 European Charger/Adapter (CE Compliant)
1019-00-0558 Charger/Adapter universal input, 12VDC output
1019-00-0557 Cigarette lighter adapter
1019-00-0467 MSCLI printer cable
1019-00-0468 Generic serial printer cable;
CLI to 25 pin male connector
1019-00-0469 CLI to PC cable
1019-00-0470 RS232 interconnect cable
(included with LST1700)