Installation instructions for LED commercial downlights
Warnings & Cautions
• To avoid electric shock, serious injury or property damage, isolate power
before installing, removing or servicing the product.
• It is recommended that luminaires are installed by a qualied
electrician to ensure the installation complies with the local current
wiring regulations.
• Any broken or damaged parts should be replaced as soon as possible.
JCC will not accept responsibility for claims arising from sub-standard
installations; which will void the warranty.
a
• It may be necessary to upgrade your MCBs to allow for increased
inrush current.
• This product is suitable for indoor use only.
• Read instructions and check that you have all of the tools and
accessories required to complete the installation correctly. Isolate
power supply before starting installation.
• This product is designed for connection to a 220-240V~ 50/60Hz.
INSTALLATION
220-240V~ 50/60Hz / Class II
LIVE = BROWN
NEUTRAL = BLUE
Double insulated- no earth required
Installation procedure
1. Cut the mounting hole in the ceiling (refer to Fig.1). (JCC recommends that
a sample hole is cut in a section of spare material to familiarize yourself
with the process).
2. Ensure there is a minimum of 75mm space around the tting. DO NOT
COVER the tting with insulation as indicated by this symbol on
the luminaire.
3. Connect the mains supply to the luminaire driver as above.
4. Turn on the power supply to test the tting. Once satised that the
luminaire is functioning correctly, press the spring clips against the
side of the luminaire and t into the aperture.
Note: when tting the luminaire do not partially install as shown below as
this can cause damage to the tting ie. if decorating.
ENGLISH
Figure 1.
Variant Driver output
VDC
10W 33.6-39.6VDC Ø150mm-160mm
16W 53.2-62.7VDC Ø200mm-210mm
22W 67.2-79.2VDC Ø220mm-230mm
Code Wattage Colour
JC72401 10W 4000K 770 77
JC72402 16W 4000K 1300 81
JC72403 22W 4000K 1750 80
JC72404 10W 4700K 770 77
JC72405 16W 4700K 1300 81
JC72406 22W 4700K 1750 80
JC73404 10W 5700K 770 77
JC73405 16W 5700K 1300 81
JC73406 22W 5700K 1750 80
Cut out size
Lumens LpcW
Temperature
g
Prole & Dimensions
10W
g
16W 22W
PLEASE NOTE
When converting to emergency version using JCEM002/
JCEM002ST, to access DC connectors remove green
cover on the DC side of the driver. Once connected,
replace connectors inside driver and ret cover.
All dimensions in millimetres
RoHS
Compliant
IP20
Do not
cover
hase.