JB-Lighting VARYSCAN 4 COMPACT PLUS 575 HMI User Manual

Page 1
JB-lighting Lichtanlagentechnik GmbH
Sallersteigweg 15 D-89134 Blaustein-Wippingen
Telefon ++49(0)7304/9617-0
Telefax ++49(0)7304/9617-99
http://www.jb-lighting.de
english
Bedienungsanleitung
Deutsch
Page 2
23
VARYSCAN 4 COMPACT PLUS 575 HMI
User Manual Index
Illustration of VS 4 1200HMI...................................................................................................................24
Back view and position of operating sections .....................................................................................25
Occupation of DMX-sockets..............................................................................................................25
Unpacking of the Varyscan
®
equipment ...............................................................................................26
Put in/ Exchange of the Bulb ..................................................................................................................26
Mounting of Mirror ...................................................................................................................................26
Starting the Equipment...........................................................................................................................26
Initialisation Mode ...............................................................................................................................27
Test Mode............................................................................................................................................27
Adjustments at DIP -Switch No.2 .......................................................................................................27
2. 6 channel drive mode (Clay Paky - Goldenscan 3 compatible).................................................27
Definition of DIP -switch positions for defined DMX-addresses........................................................29
Changing of gobos .............................................................................................................................29
GOBO measurements........................................................................................................................29
B Service instructions .............................................................................................................................30
Repair of defects.................................................................................................................................30
Adjustment of mirror stop ...................................................................................................................30
Adjustment of the motor brake...........................................................................................................30
Regular Maintenance Performances ................................................................................................30
1. Cleaning of all Optical Parts ......................................................................................................31
2. Cleaning of Ventilation...............................................................................................................31
3 Oiling of Rotating Gobos.............................................................................................................31
General Informations on DMX512 Record...........................................................................................31
Occupation of Channels for Varyscan
®
4 Compact Plus 575 HMI.....................................................32
JB lighting 8 channels .........................................................................................................................32
6 channels (Clay Paky Goldenscan 3 compatible)..........................................................................33
JB lighting 6 channel...........................................................................................................................34
Occupation DMX-In / DMX-Out .............................................................................................................36
Technical data .........................................................................................................................................36
Change of Eprom/ Software Update ....................................................................................................36
Plan of current circuits for Varyscan
®
4 Compact Plus 575 HMI........................................................37
Occupation of connectors and Jumper.................................................................................................38
List of parts for electronic board of Varyscan
®
4 Compact Plus 575 HMI ........................................38
Plan of electronic parts for electronic board of VS 4 Compact Plus 575 HMI .................................40
Page 3
24
VARYSCAN 4 COMPACT PLUS 575 HMI
Illustration of VS 4 1200HMI
Page 4
25
VARYSCAN 4 COMPACT PLUS 575 HMI
Back view and position of operating sections
Occupation of DMX-sockets
DMX-in DMX-out
Pin No. signal Colour of wire Pin No. Signal Colour of wire
1 Ground black 1 Ground black 2 DMX - white 2 DMX - white 3 DMX + red 3 DMX + red 4 free 4 not connected 5 free green/black 5 not connected
Page 5
26
VARYSCAN 4 COMPACT PLUS 575 HMI
Unpacking of the Varyscan® equipment
Varyscan® 4 Compact Plus 575 HMI operating instructions
Check, if the delivery contains all parts. Should you notice a damage through transportation, please inform immediately the carriers respectively your dealer. Also in case of noticing missing parts.
Put in/ Exchange of the Bulb
Warning: Before opening pull out mains plug!
Loosen the screws at the lid of your Varyscan
®
with a suitable screw-driver and lift the lid (label Varyscan® 4 Compact
Plus 575 HMI). You can see the bulb holder in the back third of your Varyscan
®
(see sketch page 4). Now detach nuts No.1 and No.2 and remove the bulb from it's holder. Put the new HMI bulb into the holder and tighten nuts No.1 and No.2 by hand. The point on the glass of the bulb should on no account point to the concave mirror, respectively to the lenses (sketch page 4), it should point to the base sheet or to the lid. Take care that the bulb is tightened in the holder.
Warning: Never touch the glass of bulb of the 575 HMI bulb itself !
An adjustment of the bulb is not necessary.
Mounting of Mirror
Take the mirror with the metalsheet, put it on the y-motor and close the screws.
Starting the Equipment
1. Hang up of Varyscan
®
To scoop the optimal functioning of your Varyscan®, you should hang up the spots as high as possible.
2. Adjustment of Varyscan
®
All spots should hang in the same angle, i.e. the imagined angle between perpendicular and Varyscan® should be the same among all Varyscans*.
3. Cabling of Varyscan
®
Power supply: A specialist should attach a plug to the open end of the connecting cable, or have the cable connected to 230 Volt 50 Hertz.
DMX-cabling: Connect the output of your DMX-controller with the first Varyscan
®
(controller DMX-out; Varyscan® DMX-in) with the
aid of a 5pole XLR-cabel. Now establish the connection between the Varyscans
®
with the aid of further 5pole XLR-
cables. Make sure that in DMX-out of the last Varyscan
®
there is a resistor (XLR-plug with a resistance of 100 Ohm
between pin 2 and pin 3) plugged into.
4. Adjustment at DIP-switches At DIP-switch No.1 and No.2 you have the following possibilities of adjustment:
Page 6
27
VARYSCAN 4 COMPACT PLUS 575 HMI
? initialisation mode ? test mode ? infinitely variable colour changing ? optional channels of Varyscan
®
? reset on DMX ? DMX-address
Initialisation Mode
This mode serves for adjustment and basic initialisation of the Varyscan® (carrying­out by producer).
Test Mode
To see the variety of functions of your Varyscan® easily, start the test mode by turning switch 3 off and switch 2 on at DIP-switch No.2. Now plug in your scanner and you will largely see it's functions.
Adjustments at DIP-Switch No.2
Before adjusting DMX-addresses, you have to choose a certain drive mode and then make the right choice of addresses. At DIP-switch No.2 you find 4 switches for choosing the following functions.
Infinitely Variable Colour Changing:
DIP-switch No.2 switch 1 i.e. the moment this function is turned on, every DMX-factor between 0 and 128 corresponds to an adjustment of the colour wheel. You can produce not only half colours but 1/3- 2/3 colours or 1/4- 3/4 colours etc. To choose this function, turn switch 1 at DIP-switch No.2 on.
Is switch 1 on position off, you get only full colours, respectively half colours
.
Optional Drive Modes:
DIP-switch No.2 switch 2 and 3 You have 3 DMX-channel formats to your disposal, which are explained precisely in the following text.
1. JB lighting 8 channel drive mode
channel 1 x-axis channel 2 y-axis channel 3 gobo channel 4 colour channel 5 shutter/dimmer channel 6 iris channel 7 rotating gobos; positioning and rotation channel 8 effect wheel DIP-switch position: DIP-switch No.2 switch 2 and 3 off
2. 6 channel drive mode (Clay Paky - Goldenscan 3 compatible)
channel 1 iris and gobo rotation channel 2 colour channel 3 gobo and effect wheel
Page 7
28
VARYSCAN 4 COMPACT PLUS 575 HMI
channel 4 dimmer/shutter channel 5 x-axis channel 6 y-axis DIP-switch position: DIP-switch No.2 switch 2 off, switch 3 on
3. JB-lighting 6 channel drive mode
channel 1 x-motor channel 2 y-motor channel 3 gobo channel 4 colour channel 5 dimmer/shutter channel 6 iris/gobo rotation DIP-switch position: DIP-switch No.2 switch 2 and 3 on
Reset on DMX:
DIP-switch No.2 switch 4 If you would like to reset your Varyscan
®
from your DMX-desk, turn switch 4 on at DIP-switch No.2. Now you have
the possibility to reset your Varyscan
®
, if you transmit DMX-factor 255 via gobo channel.
If switch 4 at DIP-switch No.2 is turned off, reset on DMX is not possible.
Adjustment of DMX-Addresses: DIP-switch No.1 switch 1-9
Depending on the optional drive mode, you have to adjust DMX-addresses as follows. The addressing works by a binary numeral system and in 6 channel drive mode it has to follow in six steps.
In 8 channel drive mode addresses have to be adjusted in 8 steps.
Page 8
29
VARYSCAN 4 COMPACT PLUS 575 HMI
Definition of DIP-switch positions for defined DMX-addresses
Every single DIP-switch responds to the above designated figures. If you would like to adjust a defined DMX-address, you have to add up the single figures to get it.
For example
: DMX-address "45"
32 + 8 + 4 + 1 = 45
SW6 SW4 SW3 SW1
on on on on
All remaining DIP-switches SW9 SW8 SW7 SW5 SW2 stay in position "OFF".
Changing of gobos
Open the lid with the label Varyscan® 4 Compact Plus 575 HMI, by screwing off the four screws. After opening you should unscrew the silver screws on the side of the Varyscan
®
to put out the slides. Now you are able to press the gobos at the gobo wheel out of their holder and then put in other gobos. Take care that the gobo engages exactly with it's slits in the holder. If the gobo is put in correctly, it moves easily inside the holder. Now you can close the lid.
GOBO measurements
With your Varyscan®, you have the chance of using two different gobo sizes.
1. Gobos JB-size
Outside diameter: 39,5 mm Use diameter: 28,13 mm
The three slits are placed in an angle of 120° and they are 3,2mm long and 1mm deep
2. Standard size (E-size)
Outside diameter: 37,5 mm Use diameter: 28,13 mm
Page 9
30
VARYSCAN 4 COMPACT PLUS 575 HMI
B Service instructions
Repair of defects
Defect Reparation
The appliance does not work at all (you can not see any light inside your Varyscan
®
)
Exchange 8 Ampere fuse of the appliance
The bulb of the appliance does not shine, but electronics are working, i.e. motors are working, fan is working
1. The bulb is defect, you have to change it
2. The temperature switch of the appliance is released. Plug out your Varyscan
®
and after approximately 15 minutes plug it in again. Check now, if the ventilator is working and if it is clean. If the ventilator is defect, have it exchanged by a specialist or the producer. If the scanner turns off again and again, please contact your dealer.
DMX-input does not work Control DIP-switch position
Adjustment of mirror stop
To adjust the mirror of your Varyscan® 1200 HMI, proceed as follows: Adjust the initialisation mode at DIP- switch No.1 (DIP-switch position see page 7) and start your Varyscan
®
. Now wait until the initialisation of the scan is ran through and all motors stopped. Then loosen screw No.1 Now turn the holder for the y­motor towards the stop up to a distance of 0,5 mm. Tighten screw No.1 now. During tightening the screw pay attention to the correct adjustment of the motor brake (see sketch below). Loosen screw No.2 and turn the y-motor towards the holder for the y-motor and adjust hereby a distance of 0,5 mm between the stop and the holder for the y-motor.
Adjustment of the motor brake
The motor brake is similar at each of the stepping-motor of the scan. There are three special parts (part no. 2,3 and
4) which must be installed in the following succession:
Part no. 1. motor Part no. 2. Tellerfedern Part no. 3. Stahllaserteil Part no. 4. Kunststoffscheibe Part no. 5. zu montierendes Teil
Part no. 5 has to be pushed on the axis of the stepping-motor until the parts no. 2 can not be compressed anymore. After remove the part no. 5 about 0,5 mm. After turn the fastening screws. The "motor-brake" is now optimum adjusted .
Regular Maintenance Performances
Warning: Before opening the appliance pull out mains plug!
Page 10
31
VARYSCAN 4 COMPACT PLUS 575 HMI
Open the casing by turning out the screws at the top of the Varyscan®. To be able to take out the slide-in modules of your Varyscan
®
, you have to screw off two screws of silver at the side-
piece, up to the mark of the slide-in modules. Now you are able to take out the slide-in modules (sketch page 4).
Direction: Do not forget to lock in the slide-in modules after having completed
your maintenance performances, by screwing in the screws of silver carefully!
1. Cleaning of all Optical Parts
You should clean the optical parts of your Varyscan® periodically to restore maximum brightness of the scan. After having opened the casing as explained above, take out the effect / colour wheel slide-in (see sketch page 4) and put it on an underlay before you. Take a fuzz-free rag and a detergent for windows and clean the effect / colour filters. Subsequently clean both lenses (sketch page 4). In order to clean the lens easily, loosen the screw which fixes the lens and remove the lens. Now it is easy to clean from the outside and the inside. Put in the lens and the effect colour wheel slide-in. Do not forget to tighten the screw which fixes the lens and the screws which fixes the slide-in’s
2. Cleaning of Ventilation
You should check the function of ventilators regularly. Above all take care that ventilation inlets and the interior of the Varyscan
®
are free from fuzzes and other dust. Open both lids of your Varyscan®, by screwing off the screws from the
lids. Now clean your Varyscan
®
carefully with a vacuum cleaner. Screw down the lid now. Take care that you use the
sheet metal screws for closing the smaller lid.
Attention: Take care that you do not twist or damage any parts while cleaning your scanner!
3 Oiling of Rotating Gobos
Procure a syringe with a thin needle, customary in trade (grind off the tip, so it will be blunt - no risk of injury!!), and fill it with our special oil. On no account use another kind of oil, because our oil is a special mixture. Now syringe the oil between the brass gear wheels and the brass plate and turn the rotating gobos by hand.
Attention: Do not use too much oil!
General Informations on DMX512 Record
DMX 512 record is devided in 512 addresses. You have 512 addresses to your disposal. To be able to connect different appliances with a DMX-controller, it is necessary to determine the number of DMX-channels for every appliance. The occupation of channels of a scanner could be like that for example:
channel 1 x-movement channel 2 y-movement channel 3 gobo/effect wheel channel 4 colour channel 5 shutter/dimmer channel 6 iris/gobo positioning/gobo rotation
In order that not every connected DMX-appliance performs same func tions, the appliances are addressed in series; i.e. for the first appliance the first 6 addresses are used (be right for an appliance with six channels), for the second
Page 11
32
VARYSCAN 4 COMPACT PLUS 575 HMI
one (appliance with six channels) the next 6 addresses of all the DMX-addresses are used (see for example Varyscan
®
page 10).
Occupation of Channels for Varyscan® 4 Compact Plus 575 HMI
JB lighting 8 channels
Channel 1 X-movement Channel 2 Y-movment Channel 3 gobo Channel 4 color Channel 5 shutter / dimmer Channel 6 iris Channel 7 rotating gobos (positioning and rotating) Channel 8 effect wheel
channel 1 Pan movement 170° channel 2 Tilt movement 90° channel 3 gobo
gobo 0 (Beam) DMX 000 - 031 gobo 1 DMX 032 - 063 gobo 2 DMX 064 - 095 gobo 3 DMX 096 - 127 gobo 4 DMX 128 - 159 gobo 5 DMX 160 - 255 if at DIP-switch No.2 switch 4 is "ON" gobo 5 DMX 160 - 254 Reset DMX 255
channel 4 colour
colour 0 (white) DMX 000 - 007 colour 1 DMX 008 - 015 colour 2 (red) DMX 016 - 023 colour 3 DMX 024 - 031 colour 4 (yellow) DMX 032 - 039 colour 5 DMX 040 - 047 colour 6 (pink) DMX 048 - 055 colour 7 DMX 056 - 063 colour 8 (green) DMX 064 - 071 colour 9 DMX 072 - 079 colour 10 (orange) DMX 080 - 087 colour 11 DMX 088 - 095 colour 12 (blue) DMX 096 - 103 colour 13 DMX 104 - 111 colour 14 (dark-green) DMX 112 - 119 colour 15 DMX 120 - 127 colour wheel rotation speed 1 (slow) DMX 128 ­colour wheel rotation speed 7 (fast) DMX 255
channel 5 dimmer / shutter
dimmer shutter closed --> blackout (BO) DMX 000 Dimmer 0 – 99% DMX 020 - 127 dimmer open DMX 128 - 137 dimmer shutter immediatelly DMX 138 - 139 shutter sequence 1,00 flashes/sec DMX 140 ­shutter sequence 11,00 flashes/sec DMX 243
Page 12
33
VARYSCAN 4 COMPACT PLUS 575 HMI
shutter open DMX 244 - 255
channel 6 iris
iris (linear) DMX 000 -
255
channnel 7 rotating gobos (positioning and rotation)
DMX 000 180° DMX 063 360° DMX 126 540° DMX 191 rotation left (fast) DMX 192 rotation left (slow) DMX 222 rotation stop DMX 223 - 224 rotation right (slow) DMX 225 rotation right (fast) DMX 255
channel 8 effect wheel
open DMX 000 - 031 artificial light filter DMX 032 - 063 daylight filter DMX 064 - 095 prism DMX 096 - 111 movable prism (slow) DMX 112 ­movable prism (fast) DMX 127 floodfilter DMX 128 - 159 infinitely variable from flood to open DMX 160 - 255
6 channels (Clay Paky Goldenscan 3 compatible)
channel 1 iris and gobo rotation channel 2 colour channel 3 gobo and effect wheel channel 4 dimmer / shutter channel 5 pan movement channel 6 tilt movement
channel 1 iris and gobo rotation
iris closed / gobo first position DMX 000 iris open / gobo first position DMX - 064 second gobo position DMX 065 third gobo position DMX 066 locked into position 180° DMX 106 locked into position 360° DMX 148 locked into position 540° DMX 191 rotation left fast DMX 192 rotation left slow DMX 222 rotation stop DMX 223 - 224 rotation right slow DMX 225 rotation right highest speed DMX 255
channel 2 colour
colour 0 (white) DMX 000 - 007 colour 1 DMX 008 - 015 colour 2 DMX 016 - 023 colour 3 DMX 024 - 031 colour 4 DMX 032 - 039 colour 5 DMX 040 - 047 colour 6 DMX 048 - 055 colour 7 DMX 056 - 063
Page 13
34
VARYSCAN 4 COMPACT PLUS 575 HMI
colour 8 DMX 064 - 071 colour 9 DMX 072 - 079 colour 10 DMX 080 - 087 colour 11 DMX 088 - 095 colour 12 DMX 096 - 103 colour 13 DMX 104 - 111 colour 14 DMX 112 - 119 colour 15 DMX 120 - 127 colour wheel rotation speed (slow) DMX 128 ­colour wheel rotation speed (fast) DMX 255
channel 3 gobo and effect wheel
white DMX 000 - 008 artificial light filter DMX 009 - 017 daylight filter DMX 018 - 026 prism DMX 027 - 035 floodfilter DMX 036 - 044 gobo 1 white DMX 045 - 053 gobo 1 artificial light filter DMX 054 - 062 gobo 1 daylight filter DMX 063 - 071 gobo 1 prism DMX 072 - 080 gobo 2 white DMX 081 - 089 gobo 2 artificial light filter DMX 090 - 098 gobo 2 daylight filter DMX 099 - 107 gobo 2 prism DMX 108 - 116 gobo 3 white DMX 117 - 125 gobo 3 artificial light filter DMX 126 - 134 gobo 3 daylight filter DMX 135 - 143 gobo 3 prism DMX 144 - 152 gobo 4 white DMX 153 - 161 gobo 4 artificial light filter DMX 162 - 170 gobo 4 daylight filter DMX 171 - 179 gobo 4 prism DMX 180 - 188 gobo 5 white DMX 189 - 197 gobo 5 artificial light filter DMX 198 - 206 gobo 5 daylight filter DMX 207 - 215 gobo 5 prism DMX 216 - 255 if at DIP-switch No. 2 switch is "ON" GOBO 5 prism DMX 216 - 254 Reset DMX 255
channel 4 dimmer / shutter
dimmer shutter closed --> blackout (BO) DMX 000 dimmer 0 – 99% DMX 020 - 127 dimmer open DMX 128 - 137 dimmer shutter immediatelly closed DMX 138 - 139 shutter sequence 1,00 flashes/sec DMX 140 ­shutter sequence 11,00 flashes/sec DMX 243 shutter open DMX 244 - 255
channel 5 Pan movement 170° channel 6 Tilt movement 90°
JB lighting 6 channel
channel 1 X-axis
Page 14
35
VARYSCAN 4 COMPACT PLUS 575 HMI
channel 2 Y-axis channel 3 gobo and effect wheel channel 4 colour channel 5 simmer shutter channel 6 iris and goborotation
channel 1 Pan movement 170° channel 2 Tilt movement 90° channel 3 gobo and effektwheel
white DMX 000 - 008 artificial light filter DMX 009 - 017 daylight filter DMX 018 - 026 prism DMX 027 - 035 floodfilter DMX 036 - 044 gobo 1 white DMX 045 - 053 gobo 1 artificial light filter DMX 054 - 062 gobo 1 daylight filter DMX 063 - 071 gobo 1 prism DMX 072 - 080 gobo 2 white DMX 081 - 089 gobo 2 artificial light filter DMX 090 - 098 gobo 2 daylight filter DMX 099 - 107 gobo 2 prism DMX 108 - 116 gobo 3 white DMX 117 - 125 gobo 3 artificial light filter DMX 126 - 134 gobo 3 daylight filter DMX 135 - 143 gobo 3 prism DMX 144 - 152 gobo 4 white DMX 153 - 161 gobo 4 artificial light filter DMX 162 - 170 gobo 4 daylight filter DMX 171 - 179 gobo 4 prism DMX 180 - 188 gobo 5 white DMX 189 - 197 gobo 5 artificial light filter DMX 198 - 206 gobo 5 daylight filter DMX 207 - 215 gobo 5 prism DMX 216 - 255 if at DIP-switch No. 2 switch is "ON" GOBO 5 prism DMX 216 - 254 Reset DMX 255
channel 4 colour
colour 0 (white) DMX 000 - 007 colour 1 DMX 008 - 015 colour 2 (red) DMX 016 - 023 colour 3 DMX 024 - 031 colour 4 (yellow) DMX 032 - 039 colour 5 DMX 040 - 047 colour 6 (pink) DMX 048 - 055 colour 7 DMX 056 - 063 colour 8 (green) DMX 064 - 071 colour 9 DMX 072 - 079 colour 10 (orange) DMX 080 - 087 colour 11 DMX 088 - 095 colour 12 (blue) DMX 096 - 103 colour 13 DMX 104 - 111 colour 14 (dark-green) DMX 112 - 119 colour 15 DMX 120 - 127 colour wheel rotation speed (slow) DMX 128 -
Page 15
36
VARYSCAN 4 COMPACT PLUS 575 HMI
colour wheel rotation speed (fast) DMX 255
channel 5 dimmer / shutter
dimmer shutter closed --> blackout (BO) DMX 000 dimmer DMX 019 - 127 dimmer open DMX 128 - 137 dimmer shutter immediatelly DMX 138 - 139 shutter sequence 1,00 flashes/sec DMX 140 ­shutter sequence 11,00 flashes/sec DMX 243 shutter open DMX 244 - 255
channel 6 iris and gobo rotation
iris closed / gobo first position DMX 000 iris open / gobo first position DMX - 064 second gobo position DMX 065 third gobo position DMX 066 locked into position 180° DMX 106 locked into position 360° DMX 148 locked into position 540° DMX 191 rotation left highest speed DMX 192 rotation left lowest speed DMX 222 rotation stop DMX 223 - 224 rotation right lowest speed DMX 225 rotation right highest speed DMX 255
Occupation DMX-In / DMX-Out
Position of sockets see page 5
DMX-IN DMX-OUT
Pin1: ground black Pin1: ground black Pin2: DMX- beige Pin2: DMX- beige Pin3: DMX+ red Pin3: DMX+ red Pin4: frei Pin4: frei Pin5: + 5V green Pin5: frei
Technical data
Measurements: hight 65 cm
width 27 cm
depth 29 cm Weight: 19 kg Power consumption: 1725 W Mains Voltage: 230V 50Hz 7A Bulb : Osram 575 HMI Fuse: 8 ampere inert
Change of Eprom/ Software Update
To change the Eprom proceed as follows: Remove the cover sheet for the electronic board below the mirror by taking out the 4 screws (see sketch page 4). By comparing the electronic board with the plan of electronic parts you can see the Eprom at the right side (IC U2). Carefully lever the used Eprom from the holder and exchange it for a new one.
Page 16
37
VARYSCAN 4 COMPACT PLUS 575 HMI
Direction: Pay attention to the polarity of the Eprom!
(The inlet of the Eprom has to point to the same direction as the inlet of the IC-holder.)
Close the lid and fix it with screws. Plug in your Varyscan
®
and please test all functions.
Plan of current circuits for Varyscan® 4 Compact Plus 575 HMI
Page 17
38
VARYSCAN 4 COMPACT PLUS 575 HMI
Occupation of connectors and Jumper
Pin colour Pin colour Pin colour Pin colour connector
x-motor 1 orange 2 blue 3 red 4 yellow JP2 y-motor 1 white 2 blue 3 red 4 yellow JP3 effect wheel 1 orange 2 blue 3 yellow 4 red P2 colour wheel 5 orange 6 blue 7 yellow 8 red P2 shutter/dim.1 1 orange 2 blue 3 red 4 yellow JP4 shutter/dim.2 1 orange 2 blue 3 red 4 yellow JP5 gobo wheel 5 orange 6 blue 7 yellow 8 red P1 gobo rotation 1 orange 2 blue 3 yellow 4 red P1 Iris 13 white 14 red 15 black free free P1 DMX In/Out 1 white 2 red 3 black 4 gr/bl JP1
List of parts for electronic board of Varyscan® 4 Compact Plus 575 HMI
R1 10M 0,6W R41 1R 1W R2 22K 0,6W R42 36R 1W R3 9*10K Sip 0,25W R43 36R 1W R4 9*10K Sip 0,25W R44 1R 1W R5 10K 0,6W R45 1R 1W R6 10K 0,6W R46 768R 0,6W R7 10K 0,6W R47 249R 0,6W R8 470R 0,6W R9 2k2 0,6W U1 M68HC11F1FN R10 15 k 0,6W U2 EPROM27C256 R11 1k 0,6W U3 AM 26LS32 R12 1k 0,6W U4 74HC245 R13 15k 0,6W U5 74HC138 R14 1k 0,6W U6 PBL3771 R15 15k 0,6W U7 PBM3960 R16 0R68 1W U8 PBL3771 R17 0R68 1W U9 PBM3960 R18 1R 1W U10 PBL3771 R19 1R 1W U11 PBM3960 R20 1k 0,6W U12 TCA3727 R21 1R 1W U15 TCA3727 R22 1k 0,6W U18 TCA3727 R23 1R 1W U20 TCA3727 R24 1k 0,6W R25 1R 1W S1 SW DIP -10 R26 1R 1W S2 SW DIP -4 R27 30R 1W R28 60R 0,6W R29 240R 0,6W R30 120R 0,6W
Page 18
39
VARYSCAN 4 COMPACT PLUS 575 HMI
R31 30R 1W R32 60R 0,6W R33 240R 0,6W R34 120R 0,6W R35 4R 1W R36 1R 1W R37 1R 1W R38 36R 1W R39 36R 1W R40 1R 1W C1 18pF C41 220nF C2 18pF C42 2,2nF C3 4,7uF/35V C43 100nF C4 100nF C44 470uF/35V C5 100nF C45 2,2nF C6 22uF/35V C46 47u/35V C7 100nF C47 220nF C8 100nF C48 47u/35V C9 100nF C49 220nF C10 820pF C50 4700uF/35V C11 820pF D1 LM336 C12 47uF/35V D2 Bridge C13 220nF F1 Fuse C14 220nF JP1 Header 4 C15 47uF/35V JP2 Header 4 C16 220nF JP3 Header 4 C17 220nF JP4 Header 4 C18 100nF JP5 Header 4 C19 3,3nF JP6 Header 2 C20 220nF P1 Connector DB15 C21 47uF/35V P2 Connector DB15 C22 220nF Q1 BC337B C23 47uF/35V Q2 BC337B C24 820pF Q3 BC337B C25 820pF Q4 BC337B C26 3,3nF Q5 BC337B C27 47uF/35V Q6 BC337B C28 220nF Q7 BC337B C29 220nF Q8 BC337B C30 220nF Q9 BC337B C31 47uF/35V Q10 BC337B C32 820pF Q11 BC337B C33 820pF Q12 BC337B C34 3,3nF Q13 BC337B C35 220nF Y1 Quarz 16MHz C36 220nF C37 2,2nF C38 47uF/35V C39 220nF C40 47uF/35V
Page 19
40
VARYSCAN 4 COMPACT PLUS 575 HMI
Plan of electronic parts for electronic board of VS 4 Compact Plus 575 HMI
Loading...