JB-Lighting VARYSCAN 4 COMPACT PLUS 575 HMI User Manual

JB-lighting Lichtanlagentechnik GmbH
Sallersteigweg 15 D-89134 Blaustein-Wippingen
Telefon ++49(0)7304/9617-0
Telefax ++49(0)7304/9617-99
http://www.jb-lighting.de
english
Bedienungsanleitung
Deutsch
23
VARYSCAN 4 COMPACT PLUS 575 HMI
User Manual Index
Illustration of VS 4 1200HMI...................................................................................................................24
Back view and position of operating sections .....................................................................................25
Occupation of DMX-sockets..............................................................................................................25
Unpacking of the Varyscan
®
equipment ...............................................................................................26
Put in/ Exchange of the Bulb ..................................................................................................................26
Mounting of Mirror ...................................................................................................................................26
Starting the Equipment...........................................................................................................................26
Initialisation Mode ...............................................................................................................................27
Test Mode............................................................................................................................................27
Adjustments at DIP -Switch No.2 .......................................................................................................27
2. 6 channel drive mode (Clay Paky - Goldenscan 3 compatible).................................................27
Definition of DIP -switch positions for defined DMX-addresses........................................................29
Changing of gobos .............................................................................................................................29
GOBO measurements........................................................................................................................29
B Service instructions .............................................................................................................................30
Repair of defects.................................................................................................................................30
Adjustment of mirror stop ...................................................................................................................30
Adjustment of the motor brake...........................................................................................................30
Regular Maintenance Performances ................................................................................................30
1. Cleaning of all Optical Parts ......................................................................................................31
2. Cleaning of Ventilation...............................................................................................................31
3 Oiling of Rotating Gobos.............................................................................................................31
General Informations on DMX512 Record...........................................................................................31
Occupation of Channels for Varyscan
®
4 Compact Plus 575 HMI.....................................................32
JB lighting 8 channels .........................................................................................................................32
6 channels (Clay Paky Goldenscan 3 compatible)..........................................................................33
JB lighting 6 channel...........................................................................................................................34
Occupation DMX-In / DMX-Out .............................................................................................................36
Technical data .........................................................................................................................................36
Change of Eprom/ Software Update ....................................................................................................36
Plan of current circuits for Varyscan
®
4 Compact Plus 575 HMI........................................................37
Occupation of connectors and Jumper.................................................................................................38
List of parts for electronic board of Varyscan
®
4 Compact Plus 575 HMI ........................................38
Plan of electronic parts for electronic board of VS 4 Compact Plus 575 HMI .................................40
24
VARYSCAN 4 COMPACT PLUS 575 HMI
Illustration of VS 4 1200HMI
25
VARYSCAN 4 COMPACT PLUS 575 HMI
Back view and position of operating sections
Occupation of DMX-sockets
DMX-in DMX-out
Pin No. signal Colour of wire Pin No. Signal Colour of wire
1 Ground black 1 Ground black 2 DMX - white 2 DMX - white 3 DMX + red 3 DMX + red 4 free 4 not connected 5 free green/black 5 not connected
26
VARYSCAN 4 COMPACT PLUS 575 HMI
Unpacking of the Varyscan® equipment
Varyscan® 4 Compact Plus 575 HMI operating instructions
Check, if the delivery contains all parts. Should you notice a damage through transportation, please inform immediately the carriers respectively your dealer. Also in case of noticing missing parts.
Put in/ Exchange of the Bulb
Warning: Before opening pull out mains plug!
Loosen the screws at the lid of your Varyscan
®
with a suitable screw-driver and lift the lid (label Varyscan® 4 Compact
Plus 575 HMI). You can see the bulb holder in the back third of your Varyscan
®
(see sketch page 4). Now detach nuts No.1 and No.2 and remove the bulb from it's holder. Put the new HMI bulb into the holder and tighten nuts No.1 and No.2 by hand. The point on the glass of the bulb should on no account point to the concave mirror, respectively to the lenses (sketch page 4), it should point to the base sheet or to the lid. Take care that the bulb is tightened in the holder.
Warning: Never touch the glass of bulb of the 575 HMI bulb itself !
An adjustment of the bulb is not necessary.
Mounting of Mirror
Take the mirror with the metalsheet, put it on the y-motor and close the screws.
Starting the Equipment
1. Hang up of Varyscan
®
To scoop the optimal functioning of your Varyscan®, you should hang up the spots as high as possible.
2. Adjustment of Varyscan
®
All spots should hang in the same angle, i.e. the imagined angle between perpendicular and Varyscan® should be the same among all Varyscans*.
3. Cabling of Varyscan
®
Power supply: A specialist should attach a plug to the open end of the connecting cable, or have the cable connected to 230 Volt 50 Hertz.
DMX-cabling: Connect the output of your DMX-controller with the first Varyscan
®
(controller DMX-out; Varyscan® DMX-in) with the
aid of a 5pole XLR-cabel. Now establish the connection between the Varyscans
®
with the aid of further 5pole XLR-
cables. Make sure that in DMX-out of the last Varyscan
®
there is a resistor (XLR-plug with a resistance of 100 Ohm
between pin 2 and pin 3) plugged into.
4. Adjustment at DIP-switches At DIP-switch No.1 and No.2 you have the following possibilities of adjustment:
27
VARYSCAN 4 COMPACT PLUS 575 HMI
? initialisation mode ? test mode ? infinitely variable colour changing ? optional channels of Varyscan
®
? reset on DMX ? DMX-address
Initialisation Mode
This mode serves for adjustment and basic initialisation of the Varyscan® (carrying­out by producer).
Test Mode
To see the variety of functions of your Varyscan® easily, start the test mode by turning switch 3 off and switch 2 on at DIP-switch No.2. Now plug in your scanner and you will largely see it's functions.
Adjustments at DIP-Switch No.2
Before adjusting DMX-addresses, you have to choose a certain drive mode and then make the right choice of addresses. At DIP-switch No.2 you find 4 switches for choosing the following functions.
Infinitely Variable Colour Changing:
DIP-switch No.2 switch 1 i.e. the moment this function is turned on, every DMX-factor between 0 and 128 corresponds to an adjustment of the colour wheel. You can produce not only half colours but 1/3- 2/3 colours or 1/4- 3/4 colours etc. To choose this function, turn switch 1 at DIP-switch No.2 on.
Is switch 1 on position off, you get only full colours, respectively half colours
.
Optional Drive Modes:
DIP-switch No.2 switch 2 and 3 You have 3 DMX-channel formats to your disposal, which are explained precisely in the following text.
1. JB lighting 8 channel drive mode
channel 1 x-axis channel 2 y-axis channel 3 gobo channel 4 colour channel 5 shutter/dimmer channel 6 iris channel 7 rotating gobos; positioning and rotation channel 8 effect wheel DIP-switch position: DIP-switch No.2 switch 2 and 3 off
2. 6 channel drive mode (Clay Paky - Goldenscan 3 compatible)
channel 1 iris and gobo rotation channel 2 colour channel 3 gobo and effect wheel
Loading...
+ 13 hidden pages