JBL H90 Datasheet

H90
H90
Datasheet
Applies to SKU:
IVX-576126, IVX-577126 and IVX-577136
Intellivox ADC-H90
Shaping the future of sound reinforcement
User Notice:
JBL Professional® ADC-H90 data sheet rev 2.5
• No part of this document including the software described in it may be reproduced, transmitted, transcribed, stored in a database system or translated without the express written permission of JBL Professional. Documentation kept by the end-user for backup purposes is excluded from the above mentioned.
• All products and corporate names mentioned in this document may be registered trademarks or copyrights of their respective companies. They are used here for indicative purposes only.
• The information contained in this document has been carefully checked for accuracy, however no guarantee is given with respect to the correctness. accepts no responsibility or liability for any errors or inaccuracies that may appear in this document or the products and/or software described in it.
• Specifications and information contained in this document are subject to change at any time without notice.
2
202011/H90_2.5
JBL Professional® ADC-H90 data sheet rev 2.5
Table of Contents
User Notice: .................................................................2
Table of Contents .............................................................3
1. Architectural and Engineering Specifications ......................................4
2. Specifications ..............................................................5
3. SPL Plots ..................................................................7
4. Impedance Plots ............................................................8
5. Mechanical Details ..........................................................9
6. Physical References.........................................................10
7. Optional Accessories ........................................................11
202011/H90_2.5
3
JBL Professional® ADC-H90 data sheet rev 2.5
1. Architectural and Engineering Specifications
The unit shall be constructed as a line-array of six 4” full-range loudspeakers, equipped with moisture resistant diaphragms and shall be designed for use in 100 V/70 V professional audio installations. The unit is intended for use in both public address and voice alarm systems and shall be compliant with EN 54-24. The unit shall be suitable for both indoor and outdoor use and therefore shall be compliant with the environmental requirements of EN 54-24 for both types A & B.
All necessary array signal processing shall be implemented in the analogue domain by means of a fixed set of internal filters that shall realize appropriate output channel filter transfer functions. Besides the aforementioned, the unit shall have the following functions:
• Switchable High Pass Filter (HPF).
• Switchable EQ contour.
• Switchable power taps: 100 W, 50 W and 25 W.
The audio signal shall be connected to a ceramic terminal block. A thermal fuse shall be included in the internal audio path to disconnect the unit from the 100 V/ 70V line should the unit be exposed to extreme heat and/or fire. An additional internal fuse shall be used to protect the unit from excess current. All connectors, fuses and switches shall be grouped together inside the unit and shall be accessible from a cover plate on the front of the unit. A gland shall be provided for cable entry on the rear of the unit.
A LED shall be fitted to the loudspeaker baffle which illuminates on detection of a constant high frequency pilot-tone, which shall indicate that the unit is properly connected to the 100 V/70 V line. The LED shall be visible with the grill installed.
The enclosure shall be constructed of steel finished with an epoxy coating. At the back side of the enclosure a total of two bracket attachment points shall be provided (located near the outer ends). The protective front shall consist of a perforated steel grill which can be clicked onto four snap-in studs mounted on the enclosure. For added security grill security screws shall be provided to lock the steel grill in place.
The complete loudspeaker unit shall meet the following criteria (100 W tap / HPF flat / EQ flat):
Typical frequency range of the complete array: 260 - 11k Hz on reference axis (+/- 3 dB), max. SPL at 4 m of 99 dBSPL continuous, fixed nominal horizontal opening angle at 4 m of 39° (-6 dB, averaged 1k to 4k Hz), fixed horizontal aiming angle of 0°, fixed vertical opening angle at 4 m of 135° (-6 dB, averaged 1k to 4k Hz).
Dimensions are 134 mm (5.3”) H x 865 mm (34.1”) W x 92 mm (3.6”) D. Weight 10 kg (22 lbs).
The loudspeaker unit shall be the JBL Professional model Intellivox ADC - H90.