• No part of this document including the software
described in it may be reproduced, transmitted,
transcribed, stored in a database system or
translated without the express written permission
of JBL Professional. Documentation kept by the
end-user for backup purposes is excluded from
the above mentioned.
• All products and corporate names mentioned in
this document may be registered trademarks or
copyrights of their respective companies. They are
used here for indicative purposes only.
• The information contained in this document has
been carefully checked for accuracy, however no
guarantee is given with respect to the correctness.
accepts no responsibility or liability for any errors or
inaccuracies that may appear in this document or
the products and/or software described in it.
• Specifications and information contained in this
document are subject to change at any time
without notice.
2
202011/H90_2.5
Page 3
JBL Professional® ADC-H90 data sheet rev 2.5
Table of Contents
User Notice: .................................................................2
Table of Contents .............................................................3
1. Architectural and Engineering Specifications ......................................4
The unit shall be constructed as a line-array of six
4” full-range loudspeakers, equipped with moisture
resistant diaphragms and shall be designed for use
in 100 V/70 V professional audio installations. The
unit is intended for use in both public address and
voice alarm systems and shall be compliant with EN
54-24. The unit shall be suitable for both indoor and
outdoor use and therefore shall be compliant with
the environmental requirements of EN 54-24 for both
types A & B.
All necessary array signal processing shall be
implemented in the analogue domain by means
of a fixed set of internal filters that shall realize
appropriate output channel filter transfer functions.
Besides the aforementioned, the unit shall have the
following functions:
• Switchable High Pass Filter (HPF).
• Switchable EQ contour.
• Switchable power taps: 100 W, 50 W and 25 W.
The audio signal shall be connected to a ceramic
terminal block. A thermal fuse shall be included in
the internal audio path to disconnect the unit from
the 100 V/ 70V line should the unit be exposed to
extreme heat and/or fire. An additional internal fuse
shall be used to protect the unit from excess current.
All connectors, fuses and switches shall be grouped
together inside the unit and shall be accessible from
a cover plate on the front of the unit. A gland shall be
provided for cable entry on the rear of the unit.
A LED shall be fitted to the loudspeaker baffle
which illuminates on detection of a constant
high frequency pilot-tone, which shall indicate
that the unit is properly connected to the
100 V/70 V line. The LED shall be visible with the grill
installed.
The enclosure shall be constructed of steel finished
with an epoxy coating. At the back side of the
enclosure a total of two bracket attachment points
shall be provided (located near the outer ends). The
protective front shall consist of a perforated steel
grill which can be clicked onto four snap-in studs
mounted on the enclosure. For added security grill
security screws shall be provided to lock the steel
grill in place.
The complete loudspeaker unit shall meet the following
criteria (100 W tap / HPF flat / EQ flat):
Typical frequency range of the complete
array: 260 - 11k Hz on reference axis (+/- 3
dB), max. SPL at 4 m of 99 dBSPL continuous,
fixed nominal horizontal opening angle at
4 m of 39° (-6 dB, averaged 1k to 4k Hz), fixed
horizontal aiming angle of 0°, fixed vertical opening
angle at 4 m of 135° (-6 dB, averaged 1k to 4k Hz).
Dimensions are 134 mm (5.3”) H x 865 mm (34.1”) W x 92
mm (3.6”) D. Weight 10 kg (22 lbs).
The loudspeaker unit shall be the JBL Professional
model Intellivox ADC - H90.
4
202011/H90_2.5
Page 5
JBL Professional® ADC-H90 data sheet rev 2.5
Specifications
1
Acoustical:
Frequency range
2, 3
: 260 - 11k Hz (+/-3 dB, HPF flat / EQ flat)
: 150 - 14k Hz (-10 dB, HPF flat / EQ flat)
Sensitivity (1 W / 4 m)
2, 4
: 79 dBSPL (100 W tap / HPF flat / EQ flat)
: 76 dBSPL (100 W tap / HPF active / EQ active)
Maximum SPL (100 W / 4 m)
2, 5
: 99 dBSPL (100 W tap / HPF flat / EQ flat)
: 96 dBSPL (100 W tap / HPF active / EQ active)
Horizontal coverage (-6 dB)
6, 8, 9
- 500 Hz : 66°
- 1k Hz : 50°
- 2k Hz : 39°
- 4k Hz : 27°
- 8k Hz : 15°
Vertical coverage (-6 dB)
7, 8, 9
- 500 Hz : 211°
- 1k Hz : 198°
- 2k Hz : 128°
- 4k Hz : 88°
- 8k Hz : 38°
Steering angle : Horizontal 0°
Typical throw : 15 m
Electrical:
Rated Impedance
10, 11
- 100 W tap : 100 Ω
- 50 W tap : 200 Ω
- 25 W tap : 400 Ω
Rated Noise Power10 : 100 Wrms (100 W tap)
Rated Noise Voltage10 : 100 Vrms
Control switches12 - Tap setting : 100 W / 50 W / 25 W
- Highpass filter13 : HPF active / Flat
- Correction EQ : EQ active / Flat
Fuses - Glass fuse12 : 1 A (slow type, 20 mm, replaceable)
- Thermal fuse12 : Open temperature 104 °C
Rating >= 8 A @ 250 VAC
One-shot operation (replaceable)
Connections - Terminal block12 : 100 V / 0 V / Earth (connected to
enclosure housing)
- Material : Steatite housing with brass inserts
- Rated cross-section : 2.5 mm
2
Cable gland - Maximum diameter : 13.5 mm
202011/H90_2.5
5
Page 6
JBL Professional® ADC-H90 data sheet rev 2.5
Pilot tone detection - Indicator : Green LED on front
- Frequency range : 20k - 23k Hz
- Minimum level14 : 6 Vrms
Suggested amplifiers : JBL 100 V IndustryAmp series
General:
Temperature range (ambient)15 : -25 to 70 °C
Transducers : 6 x 4” full range
Dimensions (H x W x D)16 : 134 mm (5.3”) x 865 mm (34.1”) x 92 mm (3.6”)
Default colour - Enclosure and grill : RAL 9007 (grey), applies to part number 576126
: RAL 9010 (white), applies to part number 577126
: Custom colour, applies to part number 577136
- Speaker baffle : RAL 9011 (black), applies to all part numbers
Weight : 10 kg (22 lbs)
Enclosure material - Enclosure : Steel, powder coated
- Grill : Perforated steel mesh
Standards (incl. environmental tests and enclosure protection): EN 54-24 Type B (outdoor)
17
Certificates : CE, EN 54-24
Notes:
1. The factory default setting (100 W tap / HPF active / EQ active) is assumed unless specified otherwise.
2. Measured at 4 m from the reference point on the reference axis according to EN 54-24:2008 (corrected ground plane measurement setup). See
Physical References section for details.
3. See SPL Plots section for details.
4. Measured with a broad-band pink noise signal, calculated from sound pressure levels analysed in 1/3 octave bands with center frequencies from
100 - 10k Hz.
5. Measured with simulated programme signal according to IEC 60268-1:1985, 100 Vrms with a crest factor of 6 dB.
6. Measured in the horizontal plane at 4 m from the reference point according to EN 54-24:2008 (corrected ground plane measurement setup).
See Physical References section for details.
7. Measured in the vertical plane at 4 m from the reference point according to EN 54-24:2008 (corrected ground plane measurement setup). See
Physical References section for details.
8. Measured with a broad-band pink noise signal analysed in octave bands.
9. Directivity is generally distance dependent, the DDA software package should be used for detailed directivity analysis.
10. Defined according to EN 54-24:2008.
11. See Impedance Plots section for details.
12. Located behind the inspection plate. Refer to the related Installation Manual for details.
13. Series capacitor in primary circuit.
14. The detection is most sensitive around 21k Hz, the specified level is required near the frequency extremes. The required level is not depending
on the (tap) switch settings.
15. Maximum ambient temperature for continuous operation is 40 °C. For ambient temperature below 0 °C a Frost protection scheme (as offered
by the JBL IndustryAmp amplifiers) is advised.
16. Depth of enclosure including front grill, without mounting brackets.
17. Also compliant to the requirements of Type A (indoor).
6
202011/H90_2.5
Page 7
JBL Professional® ADC-H90 data sheet rev 2.5
-40
+10
-35
-30
-25
-20
-15
-10
-5
+0
+5
d
B
S
P
L
4020k501002005001k2k5k10k
Hz
-40
+10
-35
-30
-25
-20
-15
-10
-5
+0
+5
d
B
S
P
L
4020k501002005001k2k5k10k
Hz
-20
+20
-15
-10
-5
+0
+5
+10
+15
d
B
2020k50
1002005001k2k5k10k
Hz
-40
+10
-35
-30
-25
-20
-15
-10
-5
+0
+5
d
B
S
P
L
4020k501002005001k2k5k10k
Hz
-40
+10
-35
-30
-25
-20
-15
-10
-5
+0
+5
d
B
S
P
L
4020k501002005001k2k5k10k
Hz
-20
+20
-15
-10
-5
+0
+5
+10
+15
d
B
2020k50
1002005001k2k5k10k
Hz
3. SPL Plots
Fig 1
Normalized SPL vs frequency,
100 W tap / HPF flat / EQ flat.
Fig 2
Normalized SPL vs frequency,
100 W tap / HPF flat / EQ active.
202011/H90_2.5
Fig 3
Normalized SPL vs frequency,
100 W tap / HPF active / EQ flat.
Fig 5
EQ correction.
Fig 4
Normalized SPL vs frequency,
100 W tap / HPF active / EQ active.
Fig 6
HPF correction (100 W tap).
Note: SPL data obtained from corrected ground plane measurements, MLS method, 8 ms time window, 1/3 oct averaged.
SPL plots scaled to 0 dBSPL at 1k Hz.
7
Page 8
4. Impedance Plots
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
100
1k
200
300
400
500
600
700
800
.9k
O
h
m
1040k2050 100 200500 1k 2k
5k 10k 20k
Hz
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
200
2k
400
600
800
1k
1.2k
1.4k
1.6k
1.8k
O
h
m
1040k2050 100 200500 1k 2k5k 10k 20k
Hz
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
250
4k
500
750
1k
1.25k
1.5k
1.75k
2k
2.25k
2.5k
2.75k
3k
3.25k
3.5k
3.75k
O
h
m
1040k2050 100 200500 1k 2k
5k 10k 20k
Hz
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
100
1k
200
300
400
500
600
700
800
.9k
O
h
m
1040k2050 100 200500 1k 2k
5k 10k 20k
Hz
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
200
2k
400
600
800
1k
1.2k
1.4k
1.6k
1.8k
O
h
m
1040k2050 100 200500 1k 2k5k 10k 20k
Hz
-180
+180
-160
-140
-120
-100
-80
-60
-40
-20
+0
+20
+40
+60
+80
+100
+120
+140
+160
d
e
g
250
4k
500
750
1k
1.25k
1.5k
1.75k
2k
2.25k
2.5k
2.75k
3k
3.25k
3.5k
3.75k
O
h
m
1040k2050 100 200500 1k 2k
5k 10k 20k
Hz
Fig 7
Impedance magnitude (red) and phase (green)
vs frequency, 100 W tap / HPF flat / EQ flat.
JBL Professional® ADC-H90 data sheet rev 2.5
Fig 8
Impedance magnitude (red) and phase (green)
vs frequency, 100 W tap / HPF flat / EQ active.
Fig 9
8
Fig 11
Impedance magnitude (red) and phase (green)
vs frequency, 50 W tap / HPF flat / EQ flat.
Impedance magnitude (red) and phase (green)
vs frequency, 25 W tap / HPF flat / EQ flat.
Fig 10
Impedance magnitude (red) and phase (green)
vs frequency, 50 W tap / HPF flat / EQ active.
Fig 12
Impedance magnitude (red) and phase (green)
vs frequency, 25 W tap / HPF flat / EQ active.
202011/H90_2.5
Page 9
JBL Professional® ADC-H90 data sheet rev 2.5
5. Mechanical Details
Reference point for
acoustical mounting
134
height
118,6
92,5
432,5432,5
865
695170
52
78,8
48,5
768
82
48,5
202011/H90_2.5
9
Page 10
6. Physical References
JBL Professional® ADC-H90 data sheet rev 2.5
4
Key
loudspeaker enclosure
1
loudspeaker front
2
3
reference axis
reference plane
4
reference point
5
horizontal plane
6
vertical plane
7
1
2
5
7
3
6
Notes:
1. The reference plane (4) intersects the enclosure through the loudspeaker front baffle (2).
2. The reference point (5), located in the reference plane (4), coincides with the center of the loudspeaker front baffle (2).
3. The reference axis (3), through the reference point (5), is perpendicular to the loudspeaker front baffle (2).
4. The horizontal plane (6) and the vertical plane (7) contain the reference axis (3).
10
202011/H90_2.5
Page 11
JBL Professional® ADC-H90 data sheet rev 2.5
7. Optional Accessories
Wall Bracket Set (25 mm)
(Supplied as standard)
Order SKU: IVX-802227
(2 pcs incl. fasteners)
Standard colour RAL 9007 (grey)
Swivel Bracket 90°
Order SKU: IVX-806668
(1 pcs per pack)
Standard colour RAL 9007 (grey)
Wall Bracket Set (25 mm)
Order SKU: IVX-802225
(2 pcs incl. fasteners)
Colour RAL 9010 (white)
Hinge Bracket 90°
Order SKU: IVX-802005
(1 pcs per pack)
Standard colour RAL 9007 (grey)
Swivel Bracket 45°
Order SKU: IVX-806678
(1 pcs per pack)
Standard colour RAL 9007 (grey)
Hinge Bracket 90°
Order SKU: IVX-802000
(1 pcs per pack)
Colour RAL 9010 (white)
Swivel Bracket 90°
Order SKU: IVX-806608
(1 pcs per pack)
Colour RAL 9010 (white)
Note: The provided locking mechanism of the hinges and swivel brackets is not suitable for the standard (horizontal) mounting method.