JBL CONTROL 19CST User Manual

Control
Professional Series
Key Features:
Unique Nested ChamberTMdesign and
Linear Dynamic ApertureTMport design delivers high output from a compact enclosure
JBL’s exclusive SonicGuardTMoverload
protection allows higher operational levels and improved system reliability (19CS only)
Component: Long excursion 200 mm (8 in)
driver
Packaged with grille, backcan and tile rails
for fast installation and easy stocking
Simple installation and wire connection
method
The Control 19CS uses advanced proprietary technologies to produce powerful bass from a low profile in-ceiling design. The Control 19CS is perfectly suited to augment the low frequency output of any of the Control Contractor loudspeakers. High power handling and low distortion make the Control 19CS an ideal addition for sound systems requiring a higher fidelity sound from ceiling loudspeakers.
The unique Nested Chamber design delivers high output from a compact enclosure, while the acoustic lowpass character of this design means it is easy to augment a full-range sound system without an external crossover or separate amp channel. The Linear DynamicsTMport design originally developed for JBL’s concert speaker systems, produces extended deep bass output.
The Control 19CS is protected from overload damage by JBL’s exclusive SonicGuardTMcircuitry, a protection system that is inaudible to the listener, ensuring reliability while providing full-fidelity sound. The premium performance capability ensures excellent sound character, providing pleasant, enveloping sound throughout the listening area.
The 200 mm (8 in) transducer features a pure butyl rubber surround for extended life and long excursion capability. The pole piece is vented for low distortion.
The Control 19CS can be connected into a system in a number of configurations: In parallel with full-range speakers resulting in a bass-overlap configuration (which is often acceptable); with an electronic crossover and separate amplifier channel, or; In conjunction with an active or passive high-pass filter on the full-range speakers, thus taking advantage of the Control 19CS’s natural acoustic low­pass character.
®
In-Ceiling
19CS/CST
Subwoofer
Specifications:
System:
Transducer:
Physical:
Outside Dimensions (H x Dia): 345 x 345 mm (13.6 x 13.6 in)
1
Mounted in ceiling near corner (/2 loading)
2
Continuous Pink Noise rating is shaped pink noise, 40 Hz to 400 Hz, with a 6 dB crest factor for 100 hours continuously. Continuous Program power is a conservative expression of the system’s ability to handle normal speech and music program material and is defined as 3 dB above the Continuous Pink Noise Rating.
3
Average 60 Hz to 100 Hz.
JBL continually engages in research related to product improvement. Changes introduced into existing products without notice are an expression of that philosophy.
Freq. Range (-10 dB)1: 42 Hz - 200 Hz
Power Capacity2: 200 Watts Continuous Program Power
Nominal Sensitivity3: 95 dB SPL, 1W @ 1 m (3.3 ft) in ceiling near
Nominal Coverage Angle: 180° conical coverage
Rated Maximum SPL3:
Nominal Impedance (19CS): 8 ohms
Transformer Taps (19CST): 070V: 75W, 30W, 15W & 7.5W taps
Low-Frequency: 200 mm (8.0 in) Polypropelene cone.
Enclosur
Overload Protection: Full-range power limiting to protect network and
Termination: Removable locking connector with screw-down
Safety Agency Rating: Suitable for use in air handling spaces per UL1480,
Cutout Size: 305 mm (12.0 in)
Net Weight (ea): Control 19CS: T5.5 kg (12 lb)
Shipping Weight (pair): Control 19CS: T12.7 kg (28 lb)
Included Accessories: C-shaped support backing plate
100 Watts Continuous Pink Noise
corner (␲/2) 89 dB SPL, 1W @ 1 m (3.3 ft) in center of ceiling (2␲)
115 dB @ 1 m (3.3 ft) in ceiling near corner (/2)
100V: 75W, 30W, & 15W taps
38 mm (1.5 in) coil on aluminum former
e: Backcan: Formed steel
Baffle/Rim: Medium impact polystyrene, fire rated UL94V-0
transducers. (On Control 19CS, not on Control 19CST)
terminals. 2 input terminals and 2 loop-thru output terminals. Max. wire size 12 AWG (2.5 mm2)
UL2043, NFPA90 & NFPA 70. S7232/UL Listed, Signaling Speaker. Transformer UL registered per UL1876. In accordance with IEC60849/EN60849.
318 mm (12.5 in) front of ceiling tile to back of backcan
Control 19CST: 6.3 kg (14 lb)
Control 19CST: 14.3 kg (32 lb)
2 tile support rails (fits both 2 x 4 ft or
600 x 1200 mm tiles) Cutout template Paint shield Removable locking wiring connector
Control®19CS/CST In-Ceiling Subwoofer
Input connection is conveniently provided on a removable locking connector (included), providing secure connection via screwdown terminals and allowing a system to be prewired before installing the speaker for fast snap-on convenience. Separate connector terminals are available for the input and for the loop­through wires, making it easy to jumper the speaker signal to additional speakers. The input terminal plate provides strain relief for either bare wire, plenum cable or ½ inch conduit (12 mm I.D.). The terminal box is securely enclosed to meet safety codes.
The speaker trim and grille are paintable to match any decor. A paint shield is provided for covering the drivers while painting the rim.
Installation of the Control 19CS is quick and easy. The loudspeaker is packaged complete with the backcan, grille, support backing bracket and tile rails.
The entire installation can be accomplished without requiring access above the ceiling. A template is provided for marking the cutout. An innovative C-shaped support backing plate can be installed from below through the cutout to reinforce the top of the ceiling material. Tile bridge rails are included which can be screwed onto the C-plate to extend support to the T-channel grid in suspended ceiling installations. After the speaker is fitted through the cutout, it is held securely in place via three mounting tabs which tighten onto the C-plate, if used, or directly onto the ceiling material.
The Control 19CS backcan is made of formed steel and the speaker is suitable for use in air handling spaces, per U.L.-2043. An attachment loop is provided on the backcan for cabling to the building structure as a secondary support in seismic areas or where required by code.
The optional Control 19CST version includes a high quality multitap transformer designed specifically for subwoofer use in either 70.7V or 100V distributed-line systems. Multiple transformer taps at 75W, 30W and 15W (plus 7.5W at 70.7V) allow the Control 19CST to fit a wide variety of listening situations. Taps are selected with a rotary switch conveniently located on the front panel, protected under the grille, so that the speaker does not have to be removed to adjust tap settings. The transformer effectively limits the power to the speaker, so SonicGuard is not included in the Control 19CST.
Frequency response (1W, 1 m) is measured on-axis with two boundary junction (loading, gray line) and with three-boundary junction (/2 loading, black line)
Impedance vs. Frequency
Dimensions in inches (mm)