jbc PHSE-KA, PHSE-1A, PHSE-2A, PHSE-9A Instruction Manual

IR Preheater Set
Ref. PHSE-KA
INSTRUCTION MANUAL
www.jbctools.com
2
The following items should be included:
Power Cord ............................................... 1 unit
Ref. 0009417 (100V/120V) 0009401 (230V)
Thermocouple .............. 1 unit
Ref. PH218
Kapton Tape .................. 1 unit
Ref. PH217
Manual ............................ 1 unit
Ref. 0021330
Ref. PHSE-KA
IR Preheater Set
IR Preheater Support ............................. 1 unit
Ref. PHS-SA
Heater Unit
Console
IR Preheater .............................................. 1 unit
Ref. PHSE-1A (120V) PHSE-2A (230V) PHSE-9A (100V)
RJ45 Cable ................................................ 1 unit
Ref. 0019914
www.jbctools.com
3
Features
Pedal socket (optional) Ref. P-005
Heating Areas
Power socket
Power
Fixing brackets for PHS-SA IR Preheater Support
Heater Unit
Console
2,8” Color TFT screen
Start / Stop
USB-B connector
Zone B
Zone A
RJ45 connector to Heater Unit
USB-A connector
Foot for vertical set up
Push the button to fold the foot
USB-B connector
RJ45 connector to Console
RJ12 connector to Robot
Thermocouple connectors
www.jbctools.com
4
28mm
50mm
70mm
Remove these knobs for the low level if necessary
It allows adjustment for 3 heights between the PCB and the Heating Area of the PHSE-A Heater Unit.
Low level
High level
Medium level
PHS-SA Features
Clamp knobs
Sliding guide
Spring guide
Allen key
Height Adjustment
For fixing irregular shaped PCBs to the support.
For fixing identical PCBs in the same position.
Slot clamps
5
After loosening the SP guide knobs, push the PCB against the SP guide and lift out.
Place large PCBs on the 4 rubber caps
Push the PCB against the SP guide, position it and tighten the SP guide knobs.
Changing PCBs of the same batch
The support lets you place PCBs of the same batch so as to always heat the same area. Use the sliding guides to change the PCBs.
Removing the PCB
Placing another PCB
Reworking large PCBs
www.jbctools.com
6
USB flash drive is connected.
Station is controlled by a PC.
Station is controlled by a robot.
Station software update. Press INFO to start the process.
Warning. Press INFO for failure description.
Error. Press INFO for failure description, the type of error and how to proceed.
System notifications (Status Bar)
Menu Options
Station Information
Instant power supplied to heater
Status indicator
Temperature mode
Status bar
*Original PIN: 0105
Thermocouple selected temp. and mode
· Control
· Protection
· Info
General Work mode Profile editor
ResetGraphics Files
Press INFO for each parameter description.
Available languages: English, Spanish, German, French, Italian, Portuguese, Japanese, Chinese, Russian and Korean.
Thermocouple current temp.
Select Temp. mode from the Work mode menu. In this mode the heater unit maintains the selected temperature for the TC1 thermocouple as long as the other TCs do not reach the control/protection temperature limit.
TC1 current and selected Temperature
14:15
20
º
C
Power
45%
TC1
45
º
C
Selected 150ºC
TC2
P
100
º
C
20
º
C
TC3
P
100
º
C
20
º
C
TC4
P
100
º
C
C P
Loading...
+ 14 hidden pages