Jandy H05612 User Manual

Installation and Op er a tion Man u al
JandyColors
®
Digital Color Blending, Underwater Pool and Spa Lights
WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/ spa service technician. The procedures in this manual must be followed ex act ly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
H0561200C
Page 3
Table of Contents
Section 1. Safety Information ................................................................................................................... 4
Section 2. Product Description and Model Numbers ............................................................................... 5
Section 3. Installing Jandy Light Fixture during New Construction ........................................................ 6
3.1 Preparing the Light Fixture for Installation ....................................................................... 6
3.2 Installing the Light Fixture ................................................................................................ 7
Section 4. Replacing Jandy Light Fixture in an Existing Pool or Spa ..................................................... 9
4.1 Preparing the Light Fixture for Replacement .................................................................... 9
4.2 Replacing the Light Fixture ............................................................................................... 9
Section 5. Wiring Options for Controlling Jandy Pool Lights or Jandy Spa Lights ................................. 11
5.1 Wiring to an AquaLink
5.2 Wiring to a Time Clock ..................................................................................................... 12
®
RS Control System .................................................................... 11
Section 6. Jandy Pool Light and Jandy Spa Light Operating Instructions ................................................ 13
6.1 To Operate the Light .......................................................................................................... 13
6.2 To Lock On a Specifi c Color Set ....................................................................................... 13
6.3 To Initiate a New Cycle or Reset from a Locked Color..................................................... 13
Section 7. Replacing Bulbs ....................................................................................................................... 14
Section 8. Twelve (12) Volt Installation ................................................................................................... 17
Section 9. Exploded View and Replacement Parts ................................................................................... 18
9.1 Jandy Digital Pool Light ................................................................................................... 18
9.2 Jandy Digital Spa Light ..................................................................................................... 19
Page 4
Section 1. Safety Information
IMPORTANT SAFETY INSTRUCTIONS PERTAINING TO A RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS
When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. This underwater light must be installed by a licensed or certified electrician in accordance with the National Electrical Code and applicable local codes and ordinances. Improper installation will create an electrical hazard, which could result in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Read and follow the specific instructions below.
Before installing this underwater light, read and follow all warning notices and instructions accompanying this light. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (707) 776-8200 for additional free copies of these instructions.
A TTENTION INST ALLER: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equipment.
WARNING
WARNING
NOTICE
These lights are intended for installation in fresh water swimming pools and spas only.
SAVE THESE INSTRUCTIONS
Section 2. Product Description and Model Numbers
12 Volt AC
100 feet
JPL12100
Product Voltage Cord Length Model #
Jandy Pool Light 12 Volt AC 30 feet JPL1230 Jandy Pool Light 12 Volt AC 50 feet JPL1250 Jandy Pool Light
Jandy Pool Light 120 Volt AC 30 feet JPL12030 Jandy Pool Light 120 Volt AC 50 feet JPL12050 Jandy Pool Light 120 Volt AC 100 feet JPL120100 Jandy Pool Light 120 Volt AC 150 feet JPL120150
Jandy Spa Light 12 Volt AC 30 feet JSL1230 Jandy Spa Light 12 Volt AC 50 feet JSL1250 Jandy Spa Light 12 Volt AC 100 feet JSL 12100
Jandy Spa Light 120 Volt AC 30 feet JSL12030 Jandy Spa Light 120 Volt AC 50 feet JSL12050 Jandy Spa Light 120 Volt AC 100 feet JSL120100 Jandy Spa Light 120 Volt AC 150 feet JSL120150
12 Volt AC
100 feet
JPL12100
Page 5
Page 6
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 volt
models, and must have an appropriately rated circuit breaker.
b. The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least
eight (8) inches above water level, at least four (4) inches above ground level, and at least four (4) feet from the edge of the pool or spa; see Figure 1 for pools and Figure 2 for spas.
c. The light fixture and all metal items within five (5) feet of the pool or spa must be properly
electrically bonded to a reliable point of grounding.
d. The wet niche must be properly installed so that the top edge of the underwater light’s lens is at
least 18 inches below the surface of the water in the pool or spa; see Figure 1 or 2. (Not more than 48 inch depth in Canada.)
e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground
connector located at the rear of the niche; see Figure 1 or 2.
T
Section 3. Installing Jandy Light Fixture during New Construction
3.1 Preparing the Light Fixture for Installation
NOTE The electrician must complete preparatory steps before light fixture is installed; see Figure 1 (or Figure 2, for
spa).
1. Ensure that the pool or spa meets the requirements of the current National Electrical Code and all local codes and ordinances. A licensed or certifi ed electrician must install the electrical system to meet or exceed those requirements before the underwater light is installed. Some of the requirements of the National Electrical Code, which the pool or spa’s electrical systems must meet, are as follows:
a. The lighting circuit must have a Ground Fault Circuit Interrupter (GFCI) for line voltage 120 volt
models, and must have an appropriately rated circuit breaker.
b. The Junction Box (or, for 12 volt models, the low voltage transformer) must be located at least
eight (8) inches above water level, at least four (4) inches above ground level, and at least four (4) feet from the edge of the pool or spa; see Figure 1 for pools and Figure 2 for spas.
c. The light fixture and all metal items within five (5) feet of the pool or spa must be properly
electrically bonded to a reliable point of grounding.
d. The wet niche must be properly installed so that the top edge of the underwater light’s lens is at
least 18 inches below the surface of the water in the pool or spa; see Figure 1 or 2. (Not more than 48 inch depth in Canada.)
e. The wet niche must be properly electrically bonded and grounded via the No. 8 AWG ground
connector located at the rear of the niche; see Figure 1 or 2.
NOTE The pool or spa electrical system can be verified with a Pool and Spa Electrical Qualification Test kit. The test
kit is available from local distribution. The electrical system inspection using this kit must be performed by trained and certified personnel.
48"
o GFCI, Circuit Breaker and Power Source.
Rigid Conduit
4" min.
#8 AWG Ground Connector bonding is located at rear of Niche.
min.
8" min. Junction Box or Low Voltage Transformer, maximum water level of the pool.
18" min. to top of Lens.
Concrete must be cut back around Niche to allow for a compacted plaster seal.
11.50"
Figure 1. Jandy Digital Pool Light
Coil 4 ft. of light cable around Fixture.
16"
Loading...