WARNING
FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion al pool/ spa service technician. The procedures in this manual must be followed ex act ly. Im prop er in stal la tion and/or op er a tion can create dangerous high pres sure which can cause the fi lter lid to be blown off, possibly causing death, serious injury or prop er ty damage. Improper in stal la tion and/or operation will void the war ran ty.
Before installing this product, read and follow all warning notices and instructions that accompany this fi lter. Failure to follow warning notices and instructions may result in property damage, serious injury, or death.
H0556400C
TABLE OF CONTENTS
Page 3Cartridge Filters - CJ Series Filter
Section 1. Safety Information ........................... 4
1.1 Important Safety Warning ........... 4
1.2 General Safety Instructions ......... 4
Section 2. General Information......................... 5
2.1 Introduction ................................. 5
2.2 Description .................................. 5
2.3 General Requirements............. ... 5
Section 3. Installation Instructions.................... 6
3.1 Filter Location............................. 6
3.2 Filter Preparation......................... 6
3.3 Filter Installation ......................... 7
3.4 Locking Ring Installation............ 8
Section 4. Start-Up and Operation.................... 8
4.1 New Pool and Seasonal Start-up . 8
Section 5. Filter Disassembly and Assembly .... 9
5.1 Filter Element Removal .............. 9
5.2 Changing the Outlet Port............. 10
Section 6. Maintenance..................................... 11
6.1 General Maintenance................... 11
6.2 Pressure Gauge............................ 11
6.3 Cleaning the Filter Cartridge....... 11
Section 7. Winterizing....................................... 11
Section 8. Troubleshooting ............................... 12
Section 9. Parts List and Exploded View.......... 13
®
9.1 Jandy
Cartridge Filter, CJ Series 13
9.2 Jandy® CJ Cartridge Filter Exploded
View ........................................... 13
Section 10. Head Loss Curves........................... 14
10.1 Jandy® Cartridge Filter, CJ Series 14
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL
FILTER MODEL
NOTES:
HORSEPOWER
SERIAL NUMBER
Page 4
Section 1. Safety Information
1.1 Important Safety Warning
NEVER OPERATE OR TEST THE FIL TER SYSTEM AT MORE THAN 50 PSI.
THIS FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM, i.e., FILTER, PUMP, VALVE(S), CLAMP, ETC. IS SERVICED, AIR CAN ENTER THE SYSTEM AND BECOME PRESSURIZED WHEN THE SYSTEM IS RESTARTED. PRESSURIZED AIR CAN CAUSE THE FILTER LID TO BE BLOWN OFF WHICH CAN RESULT IN DEATH, SERIOUS PERSONAL INJURY OR PROPERTY DAMAGE. TO AVOID THIS PO TEN TIAL HAZ ARD, FOL LOW ALL OF THE IN STRUC TIONS IN THIS MAN U AL.
WARNING
1.2 General Safety Instructions
ATTENTION INSTALLER:
This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner/operator of this equip ment.
1. Before repositioning valve(s) and before beginning the assembly, disassembly, or adjustment of the clamp, or any other service of the circulating system; (A) turn the pump off and shut off any automatic controls to ensure the system is not inadvertently started during servicing; (B) open the air release valve; (C) wait until all pressure is relieved (air will have stopped flowing from the air release valve).
2. Whenever installing the filter clamp follow Section 3.4 of this manual, "Locking Ring Installation".
3. Once service on the circulation system is complete, follow Section 4 of this manual, "Start-up and Operation".
4. Maintain circulation system properly. Replace worn or damaged parts immediately.
5. Be sure that the filter is properly mounted and positioned according to these installation instructions.
6. Do not pressure test above 50 PSI. Pressure testing must be done by a trained pool professional.
SAVE THESE INSTRUCTIONS.
Page 5Cartridge Filters - CJ Series Filter
Section 2. General Information
2.1 Introduction
This manual contains information for the proper instal­lation and operation of the Jandy® CJ Cartridge Filters. Procedures in this manual must be followed exactly. To obtain additional copies of this manual contact us at 707.776.8200 ext. 237. For address information see back cover.
2.2 Description
Cartridge filters do not require sand or diatomaceous earth as the filter medium. Instead they contain a filter cartridge element which is easily removed for cleaning or replacement.
Dirty water flows into the filter tank and is directed through the filter cartridge. The debris is collected on the surface of the cartridge as the water flows through it. The water will travel through the central filter core towards the bottom of the filter into the lower manifold. Clean water is returned to the swimming pool through the filter outlet port at the tank's bottom.
As debris collects in the filter, the pressure will rise and water flow to the pool will diminish. The filter will eventually become so plugged with debris that it will be necessary to remove the filter cartridge and clean it (see Section 6 "Cleaning the Filter").
NOTE A filter removes dirt and other suspended particles
but does not sanitize the pool. Pool water must be sanitized and chemically balanced for clear water. The filtration system should be designed to meet local health codes. At a minimum, the system should turnover the total volume of water in your pool two to four times in a 24 hour period.
5. Use barrel unions to connect each component of the water conditioning system for future servicing. All Jandy filters come with these type of fittings.
WARNING
The maximum working pressure for this filter is 50 psi. Never subject the filter to pressure exceeding 50 psi, even when conducting hydrostatic pressure tests. Pressures above 50 psi can cause the lid to be blown off.
6. When performing hydrostatic pressure tests or when testing for external leaks of the completed filtration and plumbing system, ensure that the maximum pressure the filtration system is subjected to does not exceed the maximum
working pressure of any of the components within the system.
2.4 Specifications and Dimensions
See Table 1 and Figure 1.
Table 1. Cartridge Filter Specifi cations
CJ200 CJ250
Filter Area (ft2) 200 250
Max. Flow (gpm) 100 125
Six Hour Capacity (gal.) 36,000 45,000
Normal Start Up Pressure (psi) 6-15 6-15
Max. Working Pressure (psi) 50 50
Dimension "A" 39½ in 45½ in.
20"
2.3 General Requirements
1. For best overall performance place the system as close to the pool as possible.
2. The filter should be located on a level concrete slab so that the orientation of the valve outlets and the pressure gauge are convenient and accessible for the installation and operation of the unit.
3. Protect the filter from the weather.
4. If fitting a chlorinator and/or any other device into the filtration plumbing circuit, great care must be xercised to ensure that the appliance is installed in accordance with the Manufacturer’s Instructions and any standards that may exist.