Jandy AquaLink RS, AquaLink RS PDA-PS4, AquaLink RS PDA-PS6, AquaLink RS PDA-PS8, AquaLink RS PDA-P4 Owner's Manual

...
Operation Data
Owner's Man u al
AquaLink® RS
PDA - Pool Digital Assistant
Pool/Spa Combination Systems and Pool Only/Spa Only Systems (Models PS4, PS6, PS8, P4, and P8)
Firmware Revision 4.1
FOR YOUR SAFETY: This product must be installed and serviced by a pro fes sion al pool/spa service technician. The procedures in this manual must be followed ex act ly. Failure to follow warning notices and instructions may result in property damage, serious injury, or death. Improper installation and/or operation will void the warranty.
ATTENTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment to an electrical source on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Modifi cations made to this equipment, which are not authorized by the manufacturer, may void the user’s authority to operate this equipment.
H0572300D
Table of Contents
Page 3
Section 1. Important Safety Instructions ........4
Section 2. Overview of the PDA Handheld
Remote .............................................6
2.1 Basic Functions ..................................................6
2.2 Using the Buttons ...............................................6
2.3 Battery Status ..................................................... 7
2.4 Signal Strength ................................................... 7
Section 3. Using the Equipment On/Off
Menu.................................................8
3.1 Equipment On/Off ...............................................8
3.2 Filter Pump ........................................................8
3.3 Spa .................................................................... 9
3.4 Pool Heat ........................................................... 9
3.5 Spa Heat .......................................................... 10
3.6 Solar Heat ........................................................ 11
3.7 Auxiliary Equipment ......................................... 12
3.8 Heat Pump ....................................................... 12
3.9 Set Light Colors ................................................ 13
3.10 Variable Speed Pump ....................................... 14
Section 4. Using the Equipment On/Off
Model Specific Menus .................. 15
4.1 TEMP1 (Pool or Spa Only) .............................. 15
4.2 TEMP2 (Pool or Spa Only) ............................... 15
4.3 Two Speed Operation ....................................... 16
Section 5. Using the Menus ........................... 17
5.1 Service Menu .................................................... 17
5.2 Diagnostics Menu ............................................. 17
5.3 Program Menu ................................................. 18
5.4 Set Temperature Menu .................................... 20
5.5 Set Time Menu .................................................20
5.6 AquaPure
®
Menu .............................................. 21
5.7 Auto Shut-off Menu .......................................... 21
5.8 Backlight Menu ................................................ 22
5.9 Assign Hotkeys Menu ...................................... 22
5.10 System Setup Menu ........................................23
5.11 Boost Menu ...................................................... 23
Section 6. Using the System Setup Menu .... 24
6.1 Label Auxiliary Menu ........................................24
6.2 Boost Setup Menu ........................................... 25
6.3 Freeze Protection Menu ...................................25
6.4 Air Temperature Menu ...................................... 26
6.5 Degrees C/F Menu ...........................................27
6.6 Temp Calibration Menu ..................................... 27
6.7 Solar Priority ..................................................... 28
6.8 Pump Lockout Menu ......................................... 28
6.9 Assign JVA Menu .............................................. 29
6.10 Set Color Lights Menu ......................................29
6.11 Spa Side Switch Menu ...................................... 30
6.12 Service Info Menu ............................................. 30
6.13 Clear Memory Menu .........................................31
6.14 Heat Pump Menu .............................................. 32
6.15 Variable Speed Pump Menu ............................. 32
Section 7. Glossaries .....................................38
7.1 Glossary of Safety Delays ...............................38
7.2 Glossary of Special Auxiliary Labels ................. 38
7.3 Glossary of PDA Handheld Remote
Messages ......................................................... 39
Section 8. PDA Handheld Remote Menu
Flow Chart ..................................... 40
Section 9. General, Water Feature, and
Light Aux Labels ........................... 41
EQUIPMENT INFORMATION RECORD
DATE OF INSTALLATION
INSTALLER INFORMATION
INITIAL PRESSURE GAUGE READING (WITH CLEAN FILTER)
PUMP MODEL
FILTER MODEL
PDA HANDHELD REMOTE MODEL SERIAL NUMBER
NOTES:
HORSEPOWER
SERIAL NUMBER
Page 4
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
LIRE LA NOTICE TECHNIQUE.
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes. When installing and using this electrical equipment, basic safety precautions should always be followed, including the following:
DANGER
To reduce the risk of injury, do not remove the suction fittings of your spa or hot tub. Never operate a spa or hot tub if the suction fittings are broken or missing. Never replace a suction fitting with one rated less than the flow rate
marked on the equipment assembly.
WARNING
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6°F (37°C). The symptoms of hyperthermia include dizziness, fainting, drowsiness, lethargy, and an increase in the internal temperature of the body. The effects of hyperthermia include: 1) unawareness of impending danger; 2) failure to perceive heat;
3) failure to recognize the need to exit spa; 4) physical inability to exit spa; 5) fetal damage in pregnant women; 6) unconsciousness resulting in a danger of drowning.
WARNING
To Reduce the Risk of Injury -
a) The water in a spa should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and
104°F (40°C) are considered safe for a healthy adult. Lower water temperatures are recommended for young children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early months of
pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to 100°F (38°C).
c) Before entering a spa or hot tub, the user should measure the water temperature with an accurate
thermometer since the tolerance of water temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to unconsciousness with
the possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems, or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa or hot tub since some medication
may induce drowsines while other medication may affect heart rate, blood pressure, and circulation.
WARNING
Risk of electric shock - Install the power center at least five (5) feet (1.52m) from the inside wall of the pool and/
or hot tub using non-metallic plumbing. Canadian installations must be at least three (3) meters from the water. Children should not use spas or hot tubs without adult supervision. Do not use spas or hot tubs unless all suction guards are installed to prevent body and hair entrapment. People using medications and/or having an adverse medical history should consult a physician before using a spa
or hot tub.
Danger d'electrocution - Les installations Canadiennes doivent se trouver à au moins trois (3) mètres de l’eau. Ne pas laisser les enfants utiliser une cuve de relaxation sans surveillance. Pour éviter que les cheveux ou une partie du corps puissent être aspirés, ne pas utiliser une cuve de relaxation si
les grilles de prise d'aspiration ne sont pas toutes en place. Les personnes qui prennent des médicaments ou ont des problèmes de santé devraient consulter un médecin
avant d’utiliser une cuve de relaxation.
AVERTISSEMENT
Page 5
WARNING
People with infectious diseases should not use a spa or hot tub. To avoid injury, exercise care when entering or exiting the spa or hot tub. Do not use drugs or alcohol before or during the use of a spa or hot tub to avoid unconsciousness and possible
drowning. Pregnant or possibly pregnant women should consult a physician before using a spa or hot tub. Water temperature in excess of 100°F (38°C) may be injurious to your health. Before entering a spa or hot tub measure the water temperature with an accurate thermometer. Do not use a spa or hot tub immediately following strenuous exercise. Prolonged immersion in a spa or hot tub may be injurious to your health. Do not permit any electric appliance (such as a light, telephone, radio, or television) within 5 feet (1.52m) of a spa
or hot tub. The use of alcohol, drugs or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas. Water temperature in excess of 100°F (38°C) may be hazardous to your health.
AVERTISSEMENT
Les personnes atteintes de maladies infectieuses ne devraient pas utiliser une cuve de relaxation. Pour éviter des blessures, user de prudence en entrant dans une cuve de relaxation et en sortant. Pour éviter l’évanouissement et la noyade éventuelle, ne prendre ni drougue ni alcool avant d’utiliser une cuve de
relaxation ni quand on s’y trouve. Les femmes enceintes, que leur grossesse soit confi rmée ou non, devraient consulter un médecin avant d’utiliser
une cuve de relaxation. Il peut être dangereux pour la santé de se plonger dans de l’eau à plus de 38°C (100°F). Avant d’utiliser une cuve de relaxation mesurer la témperature de l’eau à l’aide d’un thermomètre précis. Ne pas utiliser une cuve de relaxation immédiatement après un exercice fatigant. L’utilisation prolongée d’une cuve de relaxation peut être dangereuse pur la santé. Ne pas placer d'appareil électrique (luminaire, téléphone, radio, téléviseur, etc) à moins de 1.5m de cette cuve de
relaxation. La consommation d’alcool ou de drogue augmente considérablement les risques d’hyperthermie mortelle dans
une cuve de relaxation. Il peut etrê dangereux pour la santé de se plonger dans de l’eau à plus de 38°C (100°F).
To avoid injury ensure that you use this control system to control only packaged pool/spa heaters which have built­in operating and high limit controls to limit water temperature for pool/spa applications. This device should not be relied upon as a safety limit control.
A terminal bar marked "GROUND" is provided within the power center. To reduce the risk of electrical shock, connect this terminal bar to the grounding terminal of your electric service or supply panel with a continuous copper conductor having green insulation and one that is equivalent in size to the circuit conductors supplying this equipment, but no smaller than no. 12 AWG (3.3mm). In addition, a second wire connector should be bonded with a no. 8 AWG (4.115mm) copper wire to any metal ladders, water pipes, or other metal within five (5) feet (1.52m)
of the pool/spa.
A ground-fault circuit-interrupter must be provided if this device is used to control underwater lighting fixtures. The conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, boxes, or enclosures containing other conductors unless the additional conductors are also protected by a ground-fault circuit­interrupter. Refer to local codes for complete details.
Attention installer: Install to provide drainage of compartment for electrical components.
WARNING
CAUTION
CAUTION
SAVE THESE INSTRUCTIONS
Page 6
Section 2. Overview of the PDA Handheld Remote
This document gives in struc tions for operating the Jandy AquaLink® RS PDA handheld remote. The in struc tions must be fol lowed exactly. Read through the instructions com plete ly before operating the equipment.
2.1 Basic Functions
The AquaLink® RS PDA Handheld Remote can turn your pool/spa equipment on and off in any of the following three ways:
1. Activate the equipment manually through the EQUIPMENT ON/OFF menu.
2. Program the equipment to turn on and off at specifi c times. See Section 5.3 for a detailed explanation of how to program equipment for automatic operation.
3. Use the PDA handheld remote buttons 1 or 2 (Hotkeys). See Section 5.9 for a detailed explanation of how to program Hotkeys 1 and 2.
NOTE The default setting for Hotkeys 1 and 2 are AUX1 and AUX2 respectively. However, these buttons can be assigned to any
piece of equipment connected to a circuit or relay.
Default screen
2.2 Using the Buttons
Use the buttons as explained in the diagram below.
Back
Returns to
Previous Screen
Hotkeys 1 and 2
NOTE The default setting for Hotkeys 1 and 2 are AUX1 and AUX2 respectively. However, these buttons can be assigned to any piece of equipment connected to a circuit or relay.
Up/Down Arrow (Scroll) Keys
Power ON/Off
Selects Highlight ed Item
Page 7
2.3 Battery Status
The Battery icon , located on the left corner of the display screen, indicates the status of the battery. The PDA Handheld Remote uses two (2) AA batteries. The batteries are located behind the cover on the back side of the Handheld Remote. If the batteries have full or sufficient charge, the icon will appear on the display screen as If the batteries need to be replaced, the icon will consistently blink and appear as
.
.
2.4 Signal Strength
The Signal Strength icon , located on the left corner of the display screen, indicates the signal strength available from the Transceiver J-box to the PDA Handheld Remote. Signal strength is affected (lowered) as the PDA Handheld Remote is moved farther away from the Transceiver J-Box. Also, obstructions, such as walls, can lower the signal strength if located between the PDA Handheld Remote and the Transceiver J-Box.
Page 8
Section 3. Using the Equipment On/Off Menu
3.1 Equipment On/Off
Use this menu to manually turn a piece of equipment on or off. The ALL OFF mode will turn off equipment that has been turned on by any means (manual or pre-programmed). This includes any of the heater enables that were on (unless in use by the Maintain function).
3.1.1 To use Equipment On/Off
1. Highlight EQUIPMENT ON/OFF and press SELECT. To highlight an item, use the UP/DOWN arrow keys. Use the SELECT button to turn the equipment on or off. Return to the main menu by using the BACK button, or use the UP/DOWN arrow keys to highlight another device.
2. Highlight ALL OFF and press SELECT. After using ALL OFF, return to the main menu by using the BACK button.
OFF OFF OFF OFF OFF OFF OFF
3.2 Filter Pump
The FILTER PUMP selection turns the main filtration pump on or off for circulation to the pool. The filter pump also activates if the spa is turned on, if the pool cleaner is turned on, or if the spa spill-over effect is activated. The main filtration pump circulates the pool or spa water through the filter and heater. The pump must be on if you want to display the pool temperature, or if you want to heat the pool.
See Section 4.3, for 2-speed operation.
3.2.1 To use Filter Pump
Highlight FILTER PUMP and press SELECT. Use the SELECT button to turn the equipment on or off.
EQUIPMENT
ALL OFF FILTER PUMP SPA
POOL HEAT SPA HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF
EQUIPMENT
ALL OFF FILTER PUMP SPA
POOL HEAT SPA HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF OFF OFF OFF
Page 9
3.3 Spa
The SPA mode switches water circulation from the pool to spa (pool/spa combination models only). Turning on the spa also activates the filter pump (after a delay for valve rotation) and deactivates the pool cleaner if it is on. The SPA mode must be on to display the spa temperature and/or to heat the spa. Activation takes place after a thirty second delay (while valves are turning).
3.3.1 To use Spa
Highlight SPA and press SELECT. Use the SELECT button to turn the spa on or off.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF OFF
SPA WILL TURN ON
AFTER DELAY
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
* * * ON OFF OFF OFF OFF OFF OFF
3.4 Pool Heat
The POOL HEAT selection enables the heater for the pool. It uses the setting from SET TEMP menu, or you can increase/decrease when enabling.
3.4.1 To use Pool Heat
Highlight FILTER PUMP and press SELECT. Highlight POOL HEAT and press SELECT. Use the UP/DOWN arrow keys to set the desired temperature and press SELECT.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF OFF
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF OFF ON OFF OFF
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF OFF OFF OFF OFF
POOL HEAT
ENABLED
SET TO 80°F
Use ARROW KEYS to set valus.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF ON OFF OFF OFF OFF OFF
Page 10
3.5 Spa Heat
The SPA HEAT enables the heater for the spa. The desired temperature can be set from the SET TEMP menu, or you can increase/decrease the temperature when enabling the heater.
3.5.1 To use Spa Heat
Highlight SPA and press SELECT. The spa will come on after a short delay. Highlight SPA HEAT and press SELECT. Use the UP/DOWN arrow keys to set the desired temperature and press SELECT.
EQUIPMENT
OFF OFF OFF
FILTER PUMP SPA
ON
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF OFF
SPA WILL TURN ON
AFTER DELAY
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
* * * ON OFF OFF OFF OFF OFF OFF
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON ON OFF OFF OFF OFF OFF OFF
SPA HEAT ENABLED
SET TO 102°F
Use ARROW KEYS to set valus.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON ON OFF ON OFF OFF OFF OFF
Page 11
3.6 Solar Heat
The SOLAR HEAT selection controls solar heating. A solar heating system and optional solar sensor are required for SOLAR HEAT selection to operate and must be part of the normal circulation system.
3.6.1 To use Solar Heat
Highlight SOLAR HEAT and press SELECT. Use the SELECT button to turn SOLAR HEAT on or off.
For solar heating to take place, the SOLAR HEAT (in EQUIPMENT ON/OFF) must be enabled, also the filter pump must be on. Solar temperature must be at least 5° F above the water temperature and the water must be cooler than the thermostat setting.
FRI 10:30 PM
AIR
POOL MODE POOL HEATER SPA MODE SPA HEATER MENU EQUIPMENT ON/OFF
POOL
OFF OFF OFF OFF
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF OFF
NOTE If no Solar Sensor is installed, EXTRA AUX will appear as a menu item.
EQUIPMENT
MORE
ON OFF OFF OFF OFF OFF OFF OFF
FILTER PUMP SPA
POOL HEAT SPA HEAT AUX 1 AUX 2 AUX 3 EXTRA AUX
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF ENA OFF OFF
Page 12
3.7 Auxiliary Equipment
The AUX modes control each of the auxiliary devices plus an extra AUX. To assign a different name to an auxiliary device, use the SYSTEM SETUP and LABEL AUX menus.
NOTE Auxiliary devices are items or equipment such as pool and spa lights, waterfalls, or air blowers.
3.7.1 To turn an Auxiliary on or off
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight an AUX and press SELECT. Use the SELECT button to turn the equipment on or off.
OFF OFF OFF
ON
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF OFF OFF OFF OFF
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
ON OFF OFF OFF OFF ON OFF OFF
3.8 Heat Pump
NOTE This equipment may not be part of your system. Please check with your installer. The label HEAT PUMP may take up to
24 hours to appear on the screen after initial heat pump installation.
The HEAT PUMP selection controls the heat pump operation. In order to use the heat pump, the filter pump must be turned on and the heat pump must be in HEAT MODE (See Section 5.10), and the switch on the heat pump on the equipment pad must also be set to HEAT MODE.
NOTE HEAT PUMP takes the place of EXTRA AUX or SOLAR HEAT. It is not possible to have any two of these on the
EQUIPMENT ON/OFF menu at the same time.
3.8.1 To use Heat Pump
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight HEAT PUMP and press SELECT. Press the SELECT button to enable/disable the HEAT PUMP. The HEAT PUMP uses the SET TEMP set point.
Page 13
3.9 Set Light Colors
NOTE This equipment may not be part of your system. Please check with your installer.
The SET COLOR menu is used to set the color of a color light and then turn the light on.
NOTE Prior to setting the color of the light, the light must be assigned and controlled by an auxiliary (for example, AUX 1). See
"Using System Setup" to assign the light to an auxiliary control. Please note that the auxiliary control can be custom labeled.
3.9.1 To use Set Colors
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight the auxiliary assigned to the color light and press SELECT. A list of available colors will be displayed. The most recently selected color will be highlighted. Use the UP/DOWN arrow keys to highlight the desired color and press SELECT.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT POOL LIGHT AUX 2 AUX 3
MORE
OFF OFF OFF OFF OFF OFF OFF
ON
SET COLOR
ALPINE WHITE
SKY BLUE COBALT BLUE CARIBBEAN BLU SPRING GREEN EMERALD GREEN EMERALD ROSE MAGENTA
MORE
PLEASE WAIT . . .
CYCLING TO
CHOSEN COLOR
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT POOL LIGHT AUX 2 AUX 3
MORE
OFF OFF OFF OFF
OFF OFF
ON
ON
NOTE If you select POOL LIGHT or SPA LIGHT from the EQUIPMENT ON/OFF menu and the light is already ON, pressing
SELECT will display the message "LIGHT WILL TURN OFF IN 5 SECONDS. IF YOU WANT TO CHANGE THE COLOR PRESS SELECT NOW”. If you press SELECT, the SET COLOR menu will open and allow you to select a different color. If a different color is chosen, the light will reset to Alpine White, rotate to the selected color, and then automatically lock on to that color. During the color rotation, the message “PLEASE WAIT…CYCLING TO CHOSEN COLOR” will be displayed.
When a pool or spa light is turned ON manually, by the PDA Handheld Remote panel, or by a program, the last used color will automatically be chosen unless you press SELECT to change the color.
If you press the BACK key when in the EQUIPMENT ON/OFF menu, the light will turn on the last selected color. If the SELECT key or the BACK key is not pressed, and if it has been 15 seconds since the UP/DOWN keys have been pressed, then the most recently selected color will be selected again.
EQUIPMENT
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT POOL LIGHT AUX 2 AUX 3
MORE
OFF OFF OFF OFF
OFF OFF
ON
ON
LIGHT
WILL TURN OFF
IN 5 SECONDS. IF
YOU WANT TO
CHANGE THE COLOR PRESS SELECT NOW.
SET COLOR
ALPINE WHITE
SKY BLUE COBALT BLUE CARIBBEAN BLU SPRING GREEN EMERALD GREEN EMERALD ROSE MAGENTA
MORE
PLEASE
WAIT . . .
CYCLING TO
CHOSEN COLOR
Do not activate this feature unless you are certain that color lights are installed on your system
Important Information
Page 14
3.10 Variable Speed Pump
NOTE This equipment may not be part of your system. Please check with your installer.
The speed of a variable speed pump can be adjusted from the EQUIPMENT ON/OFF screen. In the example below the SPEED PRESET #3 is adjusted to 2750 RPM.
3.10.1 To adjust the Variable Speed Pump Setting
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight VSP1 SPD ADJ and press SELECT. Highlight SPEED3 and press SELECT. Use the UP/DOWN arrow keys to set the desired speed and press SELECT to make that speed setting take effect. Return to the main menu by using the BACK button.
EQUIPMENT
FILTER PUMP
SPA VSP1 SPD ADJ POOL HEAT SPA HEAT AUX 1 AUX 2 AUX 3
MORE
OFF OFF
OFF OFF OFF OFF OFF
SELECT SPEED POOL SPA SPEED 3 X SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT INFLOOR
MORE
SPEED 3
SET TO 2750 RPM
Use ARROW KEYS to set value. Press SELECT to continue.
NOTE Speed adjustments from the EQUIPMENT ON/OFF screen are not permanent.
SPEED SELECT
POOL
SPA SPEED 3 SPEED 4 POOL HEAT SPA HEAT SOLAR HEAT INFLOOR
MORE
X
Page 15
Section 4. Using the Equipment On/Off Model Specifi c Menus
4.1 TEMP1 (Pool or Spa Only)
NOTE This equipment may not be part of your system. Please check with your installer.
TEMP1 is the priority temperature. It must be set higher than TEMP2, and it overrides TEMP2 whenever it is enabled. Set temperature for TEMP1 before setting temperature for TEMP2.
4.1.1 To set TEMP1 (Pool or Spa Only)
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight TEMP1 and press SELECT twice. Use the UP/ DOWN arrow keys to set the desired water temperature and press SELECT to make that degree setting take effect. Return to the main menu by using the BACK button.
4.2 TEMP2 (Pool or Spa Only)
NOTE This equipment may not be part of your system. Please check with your installer.
TEMP2 is the maintenance (low) temperature. It must be set lower than TEMP1. If TEMP2 is on and TEMP1 is activated, TEMP2 will turn off and ENABLED will flash. When TEMP1 is turned off again, TEMP2 will reactivate.
4.2.1 To set TEMP2 (Pool or Spa Only)
Highlight EQUIPMENT ON/OFF and press SELECT. Highlight TEMP2 and press SELECT twice. Use the UP/ DOWN arrow keys to set the desired water temperature and press SELECT to make that degree setting take effect. Return to the main menu by using the BACK button.
EQUIPMENT
FILTER PUMP
TEMP 1 TEMP 2 SOLAR HEAT POOL LIGHT AUX 2 AUX 3 AUX 4
MORE
OFF OFF OFF OFF OFF OFF OFF
ON
TEMP1
must be set higher than
TEMP2
press ANY key
to continue.
TEMP2
ENABLED
SET TO 60°F
Use ARROW KEYS to set value. Press SELECT to continue.
EQUIPMENT
FILTER PUMP
TEMP 1 TEMP 2 SOLAR HEAT POOL LIGHT AUX 2 AUX 3 AUX 4
MORE
OFF
OFF OFF OFF OFF OFF
ON
ON
Page 16
4.3 Two Speed Operation
NOTE This equipment may not be part of your system. Please check with your installer.
Optional TWO SPEED RELAY required.
4.3.1 Two Speed Manual Operation
1. For Pool and Spa Combination Units
If your control is a POOL and SPA combination with a 2-speed fi ltration pump, the control will operate as
follows: HIGH SPEED (Filter Pump) must be on before LOW SPEED. Filter Pump button, as well as the Spa button, turns it to HIGH SPEED. LOW SPEED (AUX 2) button toggles back and forth from LOW to HIGH.
2. For Pool or Spa Only Units
To use HIGH/LOW Speeds, Filter Pump turns on HIGH SPEED, AUX 2 turns on LOW SPEED. Whatever
mode last used is the off button. To toggle, press whichever speed is not on.
3. Two Speed Programming for All Units
When programming HIGH and LOW Speeds to operate together, think of HIGH SPEED (Filter Pump) as
total duration of fi ltration time, then set Low Speed (AUX 2) to operate within that duration. For example, if you want High Speed on for 2 hours and Low Speed for 10 hours, program the Filter Pump (High Speed) from 8 AM to 8 PM and Low Speed from 10 AM to 8 PM.
NOTE It is not necessary to program both HIGH and LOW Speeds, even with a Combo Control System. If only LOW SPEED is
programmed, HIGH SPEED will turn on at the LOW SPEED on time to prime the pump. After 3 minutes the system will switch to LOW SPEED for the remainder of its programmed time.
Page 17
Section 5. Using the Menus
5.1 Service Menu
In the HELP menu, you will find the SERVICE menu. The SERVICE menu gives you the phone number (if entered) for your local service company. See SERVICE INFO menu, under SYSTEM SETUP, to enter your local service company information.
5.1.1 To use the Service menu
Highlight MENU and press SELECT, highlight HELP and press SELECT. Highlight SERVICE by using the UP/ DOWN arrow keys and press SELECT.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
HELP
Choose a topic with the arrow keys and press SELECT.
SERVICE DIAGNOSTICS
SERVICE HELP
For Service call
Local Service Co
(XXX) XXX-XXXX
CONTINUE
5.2 Diagnostics Menu
In the HELP menu, you will find the DIAGNOSTICS menu. The DIAGNOSTICS menu tells you the model, type, firmware revision level, battery status, and time calibration. Also, the connection of temperature sensors is checked.
5.2.1 To use the Diagnostics menu
Highlight MENU and press SELECT, highlight HELP and press SELECT. Highlight DIAGNOSTICS by using the UP/DOWN arrow keys and press SELECT. Select CONTINUE. The status of the temperature sensors is displayed. Select CONTINUE and a check of the remote(s) will be run. Select CONTINUE and the system will check for errors.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
HELP
Choose a topic with the arrow keys and press SELECT.
SERVICE DIAGNOSTICS
MODEL PDA-PS8
TYPE COMBO FIRMWARE PPD: PDA 4.0 J-BOX: 3.0 HANDHELD: 3.0 PWR CNTR BAT OK TIME CAL 0 0
SENSORS
WATER OK AIR OK SOLAR OPENED
CONTINUE
REMOTES PDA 1 SPA SIDE 1
CONTINUE
ERRORS
NO ERRORS
CONTINUE
Page 18
5.3 Program Menu
The Program menu allows automatic on and off times for any equipment controlled by the AquaLink® RS. You can program equipment to turn on or off all days, weekends, or weekdays. Each piece of equipment can be have a maximum of two programs per device.
5.3.1 To set automatic on and off times
Highlight MENU and press SELECT, highlight PROGRAM and press SELECT. While in the PROGRAM menu, highlight the piece of equipment and press SELECT, highlight ADD PROGRAM and press SELECT. Enter the ON/ OFF times and the range of days (for example, Weekdays, Weekends, All Days) by using the UP/DOWN arrow buttons to set values and the SELECT button to continue. When the range of days has been selected, the screen will change to show the piece of equipment selected, number of programs, on/off times, day range selected, and the chance to delete or change any of the settings to a program. Use the BACK button to go to the previous screen.
PROGRAM
FILTER PUMP SPA VSP1 SPD PGM POOL HEAT
SPA HEAT AUX 1 AUX 2 AUX 3
NEW PROGRAM ON 4:00 PM OFF 10:00 P M ALL DAYS
Use ARROW KEYS to set value. Press SELECT to continue.
To add programs use the PROGRAM menu. Select the equipment/AUX you want to add a program to and press Select. Highlight ADD PROGRAM, and press SELECT. Use UP/DOWN arrows keys to set times, press SELECT to continue.
To delete programs, use the PROGRAM menu. Highlight DELETE PROGRAM, and press SELECT. Program to be deleted must be displayed on screen. To scroll through multiple programs, highlight NEXT and press SELECT.
To change programs, also use the PROGRAM menu. Highlight CHANGE PROGRAM, and press SELECT. Program to be changed must be displayed on screen. To scroll through multiple programs, use the UP/DOWN arrows keys to select the program to be changed.
Page 19
5.3.2 Programming the Variable Speed Pump
This section describes how to program a variable speed pump.
A variable speed pump can be programmed to run at any one of its eight (8) speeds. If the variable speed pump is used for pool filtration, then it will be powered from the FILTER PUMP relay. Therefore to program the variable speed pump you must first set a program time for the FILTER PUMP, then you need to program the pump speeds to turn on/off during the FILTER PUMP cycle. If you do not program any speeds to run during the filtration cycle, then by default the variable speed pump will run at the POOL speed setting during its filtration cycle.
Example:
1. The total length of the fi ltration cycle is to be from 8am to 5pm, therefore, program the FILTER PUMP to turn on at 8am and to turn off at 5pm.
PROGRAM
FILTER PUMP SPA VSP1 SPD PGM POOL HEAT
SPA HEAT SOLAR HEAT AUX 1 AUX 2
FILTER PUMP
NEW PROGRAM ON 8:00 AM OFF 5:00 PM ALL DAYS
Use ARROW KEYS to set value. Press SELECT
.
to continue
2. To run the variable speed pump at the SPEED3 setting from 8am to 1pm, highlight and select VSP SPD1 PGM, then highlight and select SPEED3, program it to turn on at 8am and off at 1pm.
PROGRAM
FILTER PUMP SPA VSP1 SPD PGM POOL HEAT
SPA HEAT SOLAR HEAT AUX 1 AUX 2
PROGRAM SPEEDS
POOL SPA SPEED3 SPEED4
POOL HEAT SPA HEAT SOLAR HEAT SPPED8
SPEED3
NEW PROGRAM ON 8:00 AM OFF 1:00 P M ALL DAYS
Use ARROW KEYS to set value. Press SELECT to continue.
3. To run the variable speed pump at the SPEED4 setting from 1pm to 5pm, highlight and VSP SPD1 PGM, then highlight and select SPEED4, program it to turn on at 1pm and off at 5pm.
ON OFF DESCRIPTION
FILTER PUMP 8AM 5PM Total duration of filtration cycle SPEED3 8AM 1PM Pump runs at the SPEED3 setting SPEED4 1PM 5PM Pump runs at the SPEED4 setting
PROGRAM
FILTER PUMP SPA VSP1 SPD PGM POOL HEAT
SPA HEAT SOLAR HEAT AUX 1 AUX 2
PROGRAM SPEEDS
POOL SPA SPEED3 SPEED4
POOL HEAT SPA HEAT SOLAR HEAT SPPED8
SPEED4
NEW PROGRAM ON 1:00 PM OFF 5:00 P M ALL DAYS
Use ARROW KEYS to set value. Press SELECT to continue.
Page 20
5.4 Set Temperature Menu
The SET TEMP menu allows you to preset the pool and spa thermostats.
NOTE For pool/spa combination systems, the default pool temperature is 80°F and the default spa temperature is 102°F. For
pool only/spa only systems, the default TEMP1 temperature is 80°F and the default TEMP2 temperature is 60°F.
5.4.1 To set Pool/Spa Temperatures
Highlight MENU and press SELECT, highlight SET TEMP and press SELECT. Inside the SET TEMP menu, use the UP/DOWN arrow keys to highlight either POOL (TEMP1) or SPA (TEMP2) and press SELECT. Use the UP/DOWN arrow keys to increase or decrease the temperature and press SELECT to apply.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SET TEMP
POOL HEAT 80°F SPA HEAT 104°F
Highlight an
item and press SELECT
SET TEMP
POOL HEAT 80°F SPA HEAT 104°F
Highlight an
item and press SELECT
SET TEMP
POOL HEAT 85°F SPA HEAT 104°F
Highlight an
item and press SELECT
5.5 Set Time Menu
The SET TIME menu allows the correct time and date to be entered. The correct time and date ensures that programming will work properly.
NOTE A nine volt (9 V) battery is located at the Power Center that allows the system clock to continue to run during power
outages. Ensure that the battery is checked or replaced annually.
5.5.1 To set the Time
Highlight MENU and press SELECT, highlight SET TIME and press SELECT. Use the UP/DOWN arrow keys to set values. Press the SELECT button to continue.
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
MAIN MENU
SET TIME
2/14/05 MON
10:00 AM
Use ARROW KEYS to set value. Press SELECT to continue.
Page 21
5.6 AquaPure® Menu
NOTE This equipment may not be part of your system. Please check with your installer.
AquaPure chlorine generator systems exclusively communicate with the AquaLink® RS. The AquaLink® RS PDA handheld remote will display % of chlorine output. This menu item will only appear when an AquaPure chlorine generator is connected to the AquaLink PDA-P4 and PDA-P8) a single setpoint screen will be displayed. If the system is for pool/spa combination configuration (Models PDA-PS4, PDA-PS6 and PDA-PS8) a dual setpoint screen will be displayed.
®
RS system. If the system is for pool only/spa only configuration (Models
5.6.1 To set the AquaPure
Highlight MENU and press SELECT, highlight SET AQUAPURE
®
Output Percentage (%)
®
and press SELECT. Use the UP/DOWN arrow keys to change the percentage. A single setpoint screen will appear for Pool only/Spa only configuration or a dual setpoint screen will appear for for pool/spa combination configuration.
See Section 5.11 for BOOST options.
NOTE When the chlorine generator output percentage is set to a value greater than 0 and the filter pump is on, the system
salinity level and output percentage appears on the equipment status screen.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME SET AQUAPURE PDA OPTIONS SYSTEM SETUP
BOOST
Single Setpoint Screen
SET AQUAPURE
SET TO 0%
Use ARROW KEYS to set value. Press SELECT to continue.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME SET AQUAPURE PDA OPTIONS SYSTEM SETUP
BOOST
Dual Setpoint Screen
SET AQUAPURE
SET POOL TO 0%
SET SPA TO 0%
Highlight an item and press SELECT
5.7 Auto Shut-off Menu
The AUTO SHUT-OFF feature of the handheld remote can be set to a two (2) minute, five (5) minute, or ten (10) minute shut off. The display can be re-enabled by pressing the Power ON/OFF button.
NOTE To conserve the batteries the PDA default is set to two (2) minutes.
5.7.1 To change the Auto Shut-off Time
Highlight MENU and press SELECT. Highlight PDA OPTIONS and press SELECT. Highlight SET AUTO-OFF and press SELECT. Use the UP/DOWN arrow keys to set the time out value. Then press the SELECT button to continue.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
PDA OPTIONS
SET AUTO-OFF BACKLIGHT ASSIGN HOTKEYS
Choose setting and press SELECT.
SET AUTO-OFF
2 MINUTES 5 MINUTES
10 MINUTES
Use ARROW KEYS to set value. Press SELECT to continue.
Page 22
5.8 Backlight Menu
The backlight can be turned on and off. Leaving the backlight turned off will extend the battery life.
NOTE Backlight default setting is set to OFF.
5.8.1 To change the Backlight setting
Highlight MENU and press SELECT. Highlight PDA OPTIONS and press SELECT. Highlight BACKLIGHT and press SELECT. Use the UP/DOWN arrow keys to change the setting. Then press the SELECT button to continue.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
PDA OPTIONS
SET AUTO-OFF BACKLIGHT ASSIGN HOTKEYS
Choose setting and press SELECT.
BACKLIGHT
LIGHT ON
LIGHT OFF
Choose setting and press SELECT.
5.9 Assign Hotkeys Menu
The 1 and 2 buttons on the AquaLink® RS PDA Handheld Remote can be assigned to any piece of equipment connected to a circuit or relay. This provides immediate and dedicated control of the assigned equipment.
NOTE The default setting is AUX1 for button 1 and AUX2 for button 2.
5.9.1 To change the Hotkeys setting
Highlight MENU and press SELECT. Highlight PDA OPTIONS and press SELECT. Highlight ASSIGN HOTKEYS and press SELECT. Highlight 1 or 2 and press SELECT. Use the UP/DOWN arrow keys to change the setting. Then press the SELECT button to continue.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
HOTKEY #1
FILTER PUMP SPA
POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3
MORE
PDA OPTIONS
SET AUTO-OFF BACKLIGHT ASSIGN HOTKEYS
Choose setting and press SELECT.
ASSIGN HOTKEYS
1 AUX3 2 AUX2
Choose setting and press SELECT.
ASSIGN HOTKEYS
1 AUX1 2 AUX2
Choose setting and press SELECT.
Page 23
5.10 System Setup Menu
Check with installer before making changes to the SYSTEM SETUP.
5.10.1 To use the System Setup menu
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT. Use the UP/DOWN arrow keys to move the highlight bar up or down to move through the menus. Press SELECT on the highlighted item to move to the next screen.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
5.11 Boost Menu
Activates the BOOST feature that will operate the AquaPure® chlorine generator at 100% output for 24 hours.
5.11.1 To use the Boost menu
Highlight MENU and press SELECT, highlight BOOST and press SELECT. Highlight START and press SELECT to begin the chlorination cycle.
Use SET AQUAPURE in MENU to set the percentage and the AQUAPURE HOURS in SYSTEM SETUP to set the hours of operation.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME SET AQUAPURE PDA OPTIONS SYSTEM SETUP
BOOST
BOOST
Operate the
AQUAPURE
chlorinator
at 100%
for 24 hrs.
START
GO BACK
Page 24
Section 6. Using the System Setup Menu
6.1 Label Auxiliary Menu
The LABEL AUX menu allows custom naming of auxiliary equipment. For example, you can set the display to read YARD LIGHT instead of AUX 4.
6.1.1 To use the Label Auxiliary menu
Highlight MENU and press SELECT. Highlight SYSTEM SETUP and press SELECT. Highlight LABEL AUX and press SELECT. Highlight auxiliary to be labeled and press SELECT. Highlight either GENERAL LABELS, LIGHT LABELS, WTRFALL LABELS, or CUSTOM LABEL and press SELECT. Use the UP/DOWN arrow keys to highlight a name and press SELECT.
Under CUSTOM LABEL you may type in any name. Use the UP/DOWN arrow keys to change letters and use SELECT to move to the next letter.
NOTE See Section 9, General, Water Feature, and Light Labels to view the list of available labels.
NOTE Please be aware that if the label NOT USED from the GENERAL LABEL menu is used on an AUX relay, the relay will not
engage.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
LABEL AUX1
CURRENT LABEL
AUX1
GENERAL LABELS LIGHT LABELS WTRFALL LABELS CUSTOM LABEL
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
LABEL AUX1
GENERAL LABELS
AUX1
AERATOR
AIR BLOWER
BACKWASH
BOOSTER PUMP
CHEM FEED
CLEANER
MORE
AUX1 AUX2 AUX3 AUX4 AUX5 AUX6 AUX7
LABEL AUX
Page 25
6.2 Boost Setup Menu
Use this menu to adjust the number of hours or mode of Boost.
NOTE The MODE selection is only available if the Power Center Bezel dip switch 3 is turned on (Spillover mode). If it is off, then
only TIME is displayed.
The system will auto-detect the AquaPure® chlorine generator.
6.2.1 To set Boost
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight AQUAPURE HRS and press SELECT. Use the UP/DOWN arrow keys to select TIME.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME SET AQUAPURE PDA OPTIONS SYSTEM SETUP
BOOST
SYSTEM SETUP LABEL AUX FREEZE PROTECT AQUAPURE HRS AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT
MORE
BOOST
SET TIME
TIME 24 hrs
Use ARROW KEYS to set value.
6.3 Freeze Protection Menu
Use Freeze Protection menu to assign freeze protection to your pool and spa equipment. When a piece of equipment is assigned to freeze protection, it will turn on when the AquaLink is freeze-protected as a default and cannot be removed from freeze protection.
Activation temperature can be adjusted between 34°F and 42°F. Once activated, freeze protection will turn off when the air temperature is 2 degrees higher than the activation point.
Important Information on Freeze Protection
Freeze protection is intended to protect equipment and plumbing for short periods of freezing only. It does this by activating the filtration pump and circulating the water to prevent freeze inside equipment or plumbing. Freeze protection does not guarantee that equipment will not be damaged by extended periods of freezing temperatures or power outages. In these conditions, the pool and spa should be shut down completely (for example, drained of water and closed for the winter) until warmer weather exists.
®
RS detects freezing conditions. The main filter pump
Activating the spa during freezing conditions will override freeze protection. This means that if you are using your spa when freezing conditions exist, freeze protection will not circulate water to non-spa related equipment that you may have freeze protected (for example, the pool cleaner or booster pump) and thereby increasing the potential for damage to the equipment.
CAUTION
Page 26
6.3.1 To use the Freeze Protection menu
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight FREEZE PROTECT and press SELECT. Use the UP/DOWN arrows keys to change the activation temperature. Once the temperature is set, use the SELECT button to move to the next screen to assign freeze protection to a selected piece of equipment.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
FREEZE PROTECT
TEMP 38°F
Use ARROW KEYS to set value. Press SELECT to continue
FREEZE PROTECT
DEVICES
FILTER PUMP X SPA X SOLAR HEAT AUX1 AUX2 AUX3
MORE
6.4 Air Temperature Menu
Use the Air Temperature menu to turn the air temperature display on or off.
6.4.1 To disable Air Temperature display
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight AIR TEMP and press SELECT. Use the UP/DOWN arrow keys to highlight desired setting and press SELECT.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
PDA
P
o
o
l
D
i
s
g
s
i
t
A
a
l
back
select
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
PDA
back
P
o
o
t
n
a
t
s
i
l
D
select
t
n
a
t
s
i
i
s
g
s
i
t
A
a
l
AIR TEMP
DISPLAY
ENABLED DISABLED
Choose setting and press SELECT.
PDA
P
o
o
l
D
i
g
i
t
A
a
l
back
select
t
n
a
t
s
i
s
s
Page 27
6.5 Degrees C/F Menu
The Degrees C/F menu allows you to change the AquaLink® RS temperature display from Fahr en heit to Celsius or vice versa. When changing from Fahrenheit to Celsius you will have to re-enter the temperature settings.
6.5.1 To change the Temp readout
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight DEGREES C/F and press SELECT. Use the UP/DOWN arrow keys to highlight desired setting and press SELECT.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
DEGREES C/F
FAHRENHEIT
CELSIUS
Choose setting and press SELECT.
6.6 Temp Calibration Menu
This menu allows adjustment of the temperature that is displayed on the AquaLink® RS. The temperature can only be adjusted up four (4) degrees Fahrenheit or down four (4) degrees Fahrenheit, see note below.
6.6.1 To adjust Temperature display
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight TEMP CALIBRATE and press SELECT. Use the UP/DOWN arrow keys to set values and press SELECT when finished.
NOTE If the temperature is off by more than four (4) degrees, contact your local service representative.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
Page 28
6.7 Solar Priority
The Solar Priority menu allows the system to use Solar Heat primarily. If Solar Heat is no longer available, the system will automatically switch to the alternate heat source.
6.7.1 To use the Solar Priority menu
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight SOLAR PRIORITY and press SELECT. Use the UP/DOWN arrow keys to highlight desired setting and press SELECT.
When solar and heater are enabled the solar will heat the water until either the thermostat setting has been reached or solar heat is no longer available. If the solar panel is not hot enough, solar heat will shut off and the other heat source (usually gas heater) will take over to bring the water up to the thermostat setting. This menu is used to ENABLE or DISABLE the solar priority.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
SOLAR HEAT PRIOR
ENABLED DISABLED
Choose setting and press SELECT.
6.8 Pump Lockout Menu
The PUMP LOCKOUT menu allows you to enable (pump off) or disable (pump stays on) when valves are rotating from pool to spa.
6.8.1 To set Pump lockout
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight PUMP LOCKOUT and press SELECT. Use the UP/DOWN arrow keys to highlight ENABLED or DISABLED and press SELECT.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
PUMP LOCKOUT
DURING
VALVE SWITCHING
ENABLED DISABLED
Choose setting and press SELECT.
Page 29
6.9 Assign JVA Menu
The ASSIGN JVAs menu allows Jandy Valve Actuators (JVAs) to be assigned to any auxiliary button. This means that whenever you press that auxiliary button, a valve turns. On pool/spa combination models, if neither a non-booster pump pool cleaner or a solar heat system is installed, there are two extra JVAs that can be assigned to auxiliary buttons: the cleaner JVA and the solar JVA. On pool/spa only models, there are four JVAs that can be assigned to auxiliary buttons. The installer must set these JVAs for this feature to operate correctly. Assigning JVAs lets the owner control certain features like diverting water to a waterfall or bank of spa jets. Multiple JVAs can be assigned to one auxiliary button without extra hardware.
6.9.1 To set Assign JVAs
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight ASSIGN JVAs and press SELECT. Highlight the JVA you wish to use and press SELECT. Use the UP/DOWN arrow keys to move the highlight bar to the auxiliary button you want to assign, press SELECT to assign the JVA.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs
MORE
ASSIGN JVAs
INTAKE USED RETURN USED CLEANER FREE SOLAR USED
ASSIGN
CLEANER JVA
NO ASSIGNMENT AUX1 AUX2 AUX3 AUX4 AUX5 AUX6
6.10 Set Color Lights Menu
NOTE This equipment may not be part of your system. Please check with your installer.
The COLOR LIGHTS menu is used to select the color light type (Jandy Colors, Jandy LED Light, SAmTM/SAL Color Logic
NOTE You must also label the auxiliary pool or spa light.
® 2
), and to assign the color light to an available auxiliary relay.
6.10.1 To set Color Lights
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight COLOR LIGHTS and press SELECT. Use the UP/DOWN arrow keys to highlight the light type to be controlled and then press SELECT. A list of available auxiliaries will be displayed.
® 1
or
Use the UP/DOWN arrow keys to highlight an auxiliary to be assigned to a color light, then press SELECT. “JC” will appear next to the AUX if a
Jandy Colors has been assigned. “JL” will appear next to the AUX if a Jandy LED Light has been assigned."SL" will appear next to the AUX if a to the AUX if a COLOR LOGIC Light has been assigned. If the SELECT button is pressed again, while on the same selected item, the “JC”, "JL", "SL", or "CL" will disappear meaning that a color light is no longer being controlled by the auxiliary. Use the BACK button when finished.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
1
SAM/SAL is a registered trademarks of Pentair Pool Products, Inc.
2
Color Logic is a registered trademark of Hayward Industries, Inc.
SYSTEM SETUP FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs COLOR LIGHTS
MORE
SAm/SAL Light has been assigned. "CL" will appear next
SELECT COLORED
LIGHT TYPE
JANDY COLORS JANDY LED LIGHT SAM/SAL LIGHT COLORLOGIC LIGHT
Use ARROW KEYS to set value.
ASSIGN COLORED
LIGHT TO AUX
AUX1 JC AUX2 AUX3 AUX4 AUX5 AUX6 AUX7
Page 30
6.11 Spa Side Switch Menu
The spa side switch menu allows you to define which equipment is controlled by the buttons on the optional spa side switch(es). Default settings are spa, spa heat, aux1 and aux2.
You may want to write down your spa side switch button assignments so that you can label the buttons on the switch with the label pack provided.
6.11.1 To set the Spa Side Switch
NOTE The PDA system supports only one spa side switch and does not support the SpaLink RS.
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight SPA SWITCH and press SELECT. Use the UP/DOWN arrow keys to move the highlight bar to choose which button you are assigning, press SELECT. Use the UP/DOWN arrow keys to move the highlight bar to choose which piece of equipment will be associated with the button, press SELECT. After pressing SELECT on the piece of equipment, you will be returned one screen to continue assigning Spa Side Switch buttons.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SPA-SWITCH
BUTTON 1
FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX1
MORE
6.12 Service Info Menu
SYSTEM SETUP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs COLOR LIGHTS SPA SWITCH SERVICE INFO
MORE
SPA-SWITCH
BUTTON SETUP
1 FILTER PUMP 2 SPA HEAT 3 AUX1 4 AUX2
The SERVICE INFO menu is used to enter a custom product name, local service company name and telephone number.
6.12.1 To use the Service Info menu
Highlight MENU and press SELECT. Highlight SYSTEM SETUP and press SELECT. Highlight SERVICE INFO and press SELECT. Select either entry to change and press SELECT. You can then change the name of the service company and the phone number.
Page 31
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SERVICE INFO
Service Company
Local Service Co
6.13 Clear Memory Menu
SYSTEM SETUP TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs COLOR LIGHTS SPA SWITCH SERVICE INFO CLEAR MEMORY
MORE
SERVICE INFO
SERVICE CO. SERVICE PHONE
Select an entry to change, then press SELECT.
SERVICE INFO
SERVICE CO. SERVICE PHONE
Select an entry to change, then press SELECT.
SERVICE INFO
Service Phone
(XXX) XXX-XXXX
The CLEAR MEMORY menu will clear all stored values from the AquaLink® RS memory. All settings will be reset to their default settings. Stored values include auxiliary labels, all programs, freeze protection settings, remote settings, and thermostat settings. The time and date will not be cleared.
6.13.1 To use the Clear Memory menu
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight CLEAR MEMORY and press SELECT. Press SELECT. Use the UP/DOWN arrow keys to select either YES or NO. There will be a delay of 15 seconds before you see the FINISHED screen, select CONTINUE to return to SYSTEM SETUP.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
CLEAR MEMORY
FINAL WARNING
Are you SURE
that you want to
ERASE ALL SETTINGS
??
YES
NO
SYSTEM SETUP SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs COLOR LIGHTS SPA SWITCH SERVICE INFO CLEAR MEMORY HEAT PUMP
MORE
CLEAR MEMORY
ERASING
ALL
SETTINGS
please wait
CLEAR MEMORY
WARNING
Clearing memory
erases ALL
stored settings.
CONTINUE
CLEAR MEMORY
FINISHED
Press SELECT
to continue.
CONTINUE
Page 32
6.14 Heat Pump Menu
NOTE This equipment may not be part of your system. Please check with your installer.
The HEAT PUMP SETUP menu is used to put the heat pump into the heat or chill mode. If the heat mode is selected, then HEAT PUMP will be displayed on the EQUIPMENT ON/OFF menu. If chill mode is selected then CHILLER will be displayed on the EQUIPMENT ON/OFF menu.
NOTE In addition to setting heat or chill mode from the Heat Pump Setup menu, the switch on the heat pump must be manually
set to heat or chill.
6.14.1 To set the Heat Pump
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight HEAT PUMP and press SELECT. Use the UP/DOWN arrow keys to highlight either HEAT or CHILL, then press SELECT. A message will be displayed informing the user that they must walk out to the heat pump and set it to heat or chill mode as well.
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
SYSTEM SETUP SOLAR PRIORITY PUMP LOCKOUT ASSIGN JVAs COLOR LIGHTS SPA SWITCH SERVICE INFO CLEAR MEMORY HEAT PUMP
MORE
HEAT PUMP
SETUP
HEAT MODE CHILL MODE
Choose setting and press SELECT
HEAT PUMP
SETUP
HEAT/COOL MODE
MUST BE SET AT
HEAT PUMP
CONTINUE
HEAT PUMP
SETUP
DID YOU SELECT
THE PROPER
HEAT/COOL MODE
AT TH E
HEAT PUMP?
YES
NO
6.15 Variable Speed Pump Menu
NOTE This equipment may not be part of your system. Please check with your installer.
The VAR SPEED PUMP menu is used to select the variable speed pump type and to select the various pump settings. The user has the option to control one of four types of variable speed pumps, Jandy ePump IntelliFlo
® 1
VF, or IntelliFlo® VS.
TM
DC, Jandy ePump
6.15.1 To select the Pump Type
Highlight MENU and press SELECT, highlight SYSTEM SETUP and press SELECT, highlight VAR SPEED PUMP and press SELECT, highlight PUMP MODEL and press SELECT. Use the UP/DOWN arrow keys to highlight the desired model, then press SELECT. An X will appear next to the selection.
TM
AC,
MAIN MENU
HELP PROGRAM SET TEMP SET TIME PDA OPTIONS SYSTEM SETUP
1
IntelliFlo is a registered trademark of Pentair Pool Products, Inc.
VAR SPEED PUMP LABEL AUX FREEZE PROTECT AIR TEMP DEGREES C/F TEMP CALIBRATE SOLAR PRIORITY PUMP LOCKOUT
SYSTEM SETUP
MORE
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED/LABELS PRIME
Highlight an item and press SELECT
PUMP MODEL
JANDY ePUMP DC JANDY ePUMP AC INTELLIFLO VF INTELLIFLO VS X
Highlight an item and press SELECT
Page 33
6.15.2 To Set the Pump Application
The PDA can control up to four (4) variable speed pumps. The default application setting for each pump is NOT INSTALLED. If the system is not going to control a variable speed pump then leave the application set to NOT INSTALLED. If the system is going to control a variable speed pump, then you would set the application to FILTRATION or AUX. PUMP. In the example below we are telling the system that it will be controlling one variable speed pump.
In the VSP SETTINGS menu, highlight PUMP APPLICATION and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight the desired setting, then press SELECT. An X will appear next to the selection.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED/LABELS PRIME
Highlight an item and press SELECT
PUMP APPLICATION
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
PUMP APPLICATION
PUMP 1
FILTRATION AUX. PUMP NOT INSTALLED X
Highlight an item and press SELECT
PUMP APPLICATION
PUMP 1
FILTRATION X AUX. PUMP NOT INSTALLED
Highlight an item and press SELECT
Page 34
6.15.4 To Set SCALE/MIN-MAX Parameters
This screen allows the user to set a minimum and maximum speed or flow for the indicated pump. The SCALE setting is fixed to RPM for the Jandy ePump GPM for the IntelliFlo
®
VF.
TM
DC, Jandy ePump
TM
AC, and IntelliFlo® VS. The SCALE setting is fixed to
In the VSP SETTINGS menu, highlight MIN-MAX SETTINGS and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to set the desired speed, then press SELECT.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED LABELS PRIME
Highlight an item and press SELECT
MIN-MAX SETTINGS
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
MIN-MAX SETTINGS
PUMP 1
SCALE RPM MIN LIMIT 400 MAX LIMIT 3450
Highlight an item and press SELECT
6.15.5 To set the Pump Speed
There are eight (8) default speed presets for each variable speed pump.
In the VSP SETTINGS menu, highlight SPEED and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET SPEEDS, then press SELECT. Use the UP/DOWN arrow keys to highlight the desired speed preset, then press SELECT. Use the UP/DOWN arrow keys to adjust the speed value, then press SELECT.
NOTE The FREEZE PROTECT speed is also set from tis menu.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED/LABELS PRIME
Highlight an item and press SELECT
SPEED/LABELS
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
SPEED/LABELS
PUMP 1
SET SPEEDS LABEL SPEEDS ASSIGN SPEEDS
Highlight an item and press SELECT
SET SPEED
(RPM) POOL SPA SPEED3 SPEED4 POOL HEAT SPA HEAT SOLAR HEAT INFLOOR
1725 2750 2750 2750 2250 2250 2750 2750
ADJUST POOL
(RPM)
POOL
1725
Use ARROW KEYS to set value. Press SELECT to continue.
6.15.6 Default Preset Speed Labels
The default speed preset labels are shown in the table below.
Default Labels when Pump is configured for FILTRATION
PRESET # POOL/SPA COMBO POOL/SPA ONLY
1 POOL POOL 2 SPA SPEED2 3 SPEED3 or CLEANER (if dip S1-1 is on) SPEED3 or CLEANER (dip S1-1 is on) 4 SPEED4 or SPILLOVER (if dip S1-3 is on) SPEED4 5 POOL HEAT TEMP1 6 SPA HEAT TEMP2 7 SOLAR HEAT (if dip S1-7 is on) or HEATPUMP
(if dip S1-7 is on) or SPEED7
8 SPEED8 SPEED8
SOLAR HEAT (if dip S1-7 is on) or HEATPUMP (if dip S1-7 is on) or SPEED7
Page 35
Preset 1:
The default label for preset #1 is POOL. This label is tied to the pool filtration mode. Anytime the pool pump is supposed to turn on, this preset is selected.
Preset 2:
On combo systems, the default label for preset #2 is SPA. This label is tied to the spa filtration mode. Anytime the spa pump is supposed to turn on, this preset is selected.
Preset 3:
On combo systems, if dip S1-1 is ON, then the default label for this preset is CLEANER. Anytime the cleaner mode is turned on the pump will run at the speed setting of this preset.
On a combo system, if dip S1-1 is OFF, then the default label for this preset is SPEED3.
On a pool/spa only system, the default label is SPEED3.
Preset 4:
If dip switch S1-3 is ON, then the default label for this preset is SPILLOVER. Anytime the spillover mode is turned on the pump will run at the speed setting of this preset.
If dip switch S1-3 is OFF, then the default label for this preset is SPEED4.
Preset 5:
On Pool/Spa Combo systems, the default label is POOL HEAT. When the pool heater is enabled the pump will run at this speed.
On Pool/Spa Only systems, the default label is TEMP1. When the pump is running and the heater set point TEMP1 is enabled, then the pump will run at this preset.
Preset 6:
On Pool/Spa Combo systems, the default label is SPA HEAT. When the system is in the SPA mode and the SPA HEATER is enabled then the pump will run at this speed.
On Pool/Spa Only systems, the default label is TEMP2. When the pump is running and the heater set point TEMP2 is enabled, then the pump will run at this preset.
Preset 7:
If the system is in the SOLAR HEAT mode or the HEAT PUMP mode then the pump will run at this preset speed. If the system is not configured for solar heat or a heat pump then the default label will be SPEED7.
Preset 8:
The default label for preset #8 is SPEED8.
NOTE If a pump is configured as an AUX. PUMP, it operates independently from the filtration mode.
Page 36
6.15.7 To re-label the Speed Preset
Each of the eight (8) default speed presets has a label and each of those labels can be changed from the default value.
In the SPEED SETTINGS menu, highlight LABEL SPEEDS and press SELECT. Use the UP/DOWN arrow keys to highlight the desired label, then press SELECT. Use the UP/DOWN arrow keys to highlight either GENERAL LABELS or CUSTOM LABELS, then press SELECT.
SPEED/LABELS
PUMP 1
SET SPEEDS LABEL SPEEDS ASSIGN SPEEDS
Highlight an item and press SELECT
LABEL SPEEDS
POOL SPA SPEED3 SPEED4 POOL HEAT SPA HEAT SOLAR HEAT INFLOOR
LABEL POOL
CURRENT LABEL
POOL
GENERAL LABELS CUSTOM LABELS
LABEL POOL
GENERAL LABELS
POOL
AERATOR
AIR BLOWER
BACKWASH
BOOSTER PUMP
CHEM FEED
CLEANER
6.15.8 To Assign Speeds to Auxiliaries
This menu allows the user to assign a speed to an auxiliary. When the assigned auxiliary is turned on the pump will switch to the speed that was assigned to the aux. If more than one aux is on and if both of them have speeds assigned, the pump will operate at the higher of the two speeds.
In the VSP SETTINGS menu, highlight SPEED/LABELS and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight ASSIGN SPEEDS, then press SELECT. Use the UP/DOWN arrow keys to highlight the desired auxiliary, then press SELECT. Use the UP/ DOWN arrow keys to highlight the desired speeds, then press SELECT.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED/LABELS PRIME
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1
SET SPEED SET DURATION ASSIGN SPEEDS
Highlight an item and press SELECT
ASSIGN SPEEDS
PUMP 1 AUX 1 AUX 2 AUX 3 AUX 4 AUX 5 AUX 6 AUX 7
ASSIGN SPEEDS
SPEED1 SPEED2 SPEED3 SPEED4 SPEED5 SPEED6 SPEED7 SPEED8
AUX 1
X
Page 37
6.15.9 To Set the Priming Speed
Whenever the variable speed pump is turned on it will go into the priming mode for a predetermined amount of time (1-5 minutes). This menu allows for the priming speed to be adjusted.
NOTE The priming parameters for the IntelliFlo® are set at the pump.
In the VSP SETTINGS menu, highlight PRIME and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET SPEED, then press SELECT. Use the UP/DOWN arrow keys to set value, then press SELECT.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION SCALE/MIN-MAX SPEED/LABELS PRIME
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1
SET SPEED SET DURATION
Highlight an item and press SELECT
SET PRIME SPEED
(RPM)
2500
Use ARROW KEYS to set value. Press SELECT to continue
6.15.10 To Set the Priming Duration
This menu allows for the user to set the length of time the priming takes place (1-5 minutes).
In the VSP SETTINGS menu, highlight PRIME and press SELECT. Use the UP/DOWN arrow keys to highlight the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET DURATION, then press SELECT. Use the UP/DOWN arrow keys to set value, the press SELECT.
VSP SETTINGS
PUMP MODEL PUMP APPLICATION MIN-MAX SETTINGS SPEED/LABELS PRIME
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1 PUMP 2 PUMP 3 PUMP 4
Highlight an item and press SELECT
PRIME SETTINGS
PUMP 1
SET SPEED SET DURATION
Highlight an item and press SELECT
SET PRIME TIME
(MINUTES)
1
Use ARROW KEYS to set value. Press SELECT to continue
Page 38
Section 7. Glossaries
7.1 Glossary of Safety Delays
Pool/Spa Switching Filter Pump Delay - The lter pump turns off while valves rotate between pool and spa to prevent damage
to the pool equipment. The valves take 35 seconds to rotate between pool and spa; the fi lter pump will activate as soon as the valves have fi nished turning.
Heater Cool Down Delay - When the system is heating (water is circulating to the spa) and the Spa button is pressed, the system
will remain in Spa Mode for fi ve minutes, and will continue to circulate the water. This delay allows water to cool the heater down by circulating water through it, preventing equipment damage. The fi ve minute delay starts counting down when the heater goes off. If the heater has been off for fi ve minutes or more, prior to turning off the Spa, there will not be a delay.
Heater Start-up - The heater will only come on if the water is circulating (for example, the fi lter pump is on and has been
circulating for 15 seconds) to the corresponding body of water (for example, spa for spa heater) and the actual water temperature is below the temperature you set with TEMP SET in the Menu. If these conditions are not met, the heater will be enabled (ready to go), but will not fi re.
Heater “Short Cycling” Prevention - When the heater is activated and the desired temperature is reached, heater will turn off and
remain off for 3 minutes, even if the temperature falls below the desired temperature. This feature prevents heater short cycling (in other words, the heater turning off and on in rapid succession).
Cleaner Lockout - The pool cleaner will only activate if the system is in pool mode and water is circulating. The pool cleaner
requires that water is circulating to the pool in order for it to operate. Return to pool mode to activate the cleaner.
Spillover Lockout - The spillover will only activate if the system is in pool mode and water is circulating. The spillover requires
that water is circulating to the pool in order for it to operate. Return to pool mode to activate the waterfall. Also, if the pool cleaner is on, it will turn off during spillover operation.
Spillover - When Dip Switch 3 is in the ON position, the Aux. 3 relay socket is activated and the return valve actuator turns.
The spillover is disabled while the spa is on. A message is displayed when spillover is turned on while in spa mode (water is cir cu la ting to spa). The spillover requires that water cir cu la tion is to pool in order to op er ate. The spillover will activate when the system switches back to pool mode.
Enabled - When activated allows the function to work.
Disabled - When activated does not allow the function to work.
7.2 Glossary of Special Auxiliary Labels
Spare AUX- Operates only with Pool/Spa combination units.
Extra AUX- System features (for example, software labeling and timed aux) can be assigned to the EXTRA AUX button. Only
freeze protection cannot be assigned to the extra auxiliary.
Air Blower - When an AUX button labeled “Air Blower” is pressed, it will turn on the air blower for 30 minutes, then
automatically turn it off. An air blower may be programmed like any other auxiliary, except that you can program only the ON time. The air blower will turn on at the programmed ON time, and turn off 30 minutes later. This is to protect the blower motor from overheating during extended operation.
Fill Line - When an AUX button labeled “Fill Line” is pressed, it will turn on the fi ll line for 30 minutes, and then automatically
turn it off. A fi ll line may be programmed like any other auxiliary, except that you can program only the ON time. The fi ll line will turn on at the programmed ON time, and turn off 30 minutes later. This is to avoid overfi lling the pool. Choose the appropriate number of "fi ll" programs during the week to keep your pool at the appropriate level.
Page 39
7.3 Glossary of PDA Handheld Remote Messages
BATTERY is LOW - This message (located in DIAGNOSTICS under the MENU) indicates that the battery supplying power to the Power Center clock (in case of power outage) is low, and should be replaced. The battery is a standard 9V, and may be replaced by removing the battery door (marked on the Power Center - Power Center is located by the pool equipment).
CLEANER CANNOT BE TURNED ON WHILE SPA IS ON - This message is displayed if the pool cleaner is activated when in spa mode and water is circulating to the spa. The pool cleaner requires that water be circulating to the pool in order for it to operate. Return to pool mode to activate the cleaner.
CLEANER CANNOT BE TURNED ON WHILE SPILLOVER IS ON - The return valve has been rotated to the spa position to give the spa spillover effect.
FREEZE PROTECT - This message indicates that freezing conditions have been detected by the freeze protection sensor, and that equipment assigned to freeze protection are active (for example, the fi lter pump). See Section 6.3, Freeze Protection Menu for more information.
NOTE
The filter pump is always protected; spa and auxiliary circuits can be assigned to freeze protection. If a freeze protected
Auxiliary is turned off during freeze protection, a message will be displayed indicating that item is off but will turn on in X amount of minutes. The minutes will vary depending on how long freeze mode has been active from 1 to 15 minutes.
SENSOR OPEN - This error message indicates that the sensor is not installed properly or is malfunctioning. Call your pool service person to resolve this problem.
NOTE
If the message reads WATER TEMP OPEN, the heater will not fire. If message AIR TEMP OPEN is displayed, freeze
protection will not operate correctly.
POOL HEATER ENABLED - This message indicates that the pool heater is ready to use but is not actually fi ring. The fi lter pump must be on, and the water temperature must be below the setting for the heater to fi re.
PUMP WILL REMAIN ON WHILE SPILLOVER IS ON - This message is displayed when you attempt to turn off the fi lter pump while a spa spillover is on. Since the fi lter pump is necessary for spillover operation, the pump will remain on until the spillover is turned off.
PUMP WILL TURN OFF AFTER COOL DOWN CYCLE - This message indicates that the fi lter pump is circulating water to cool down the heater. The fi lter pump will continue to run for fi ve minutes to protect the heater from damage, whenever the heater has fi red and has been off for less than 5 minutes.
PUMP WILL TURN ON AFTER DELAY - This message is displayed during pool/spa switching. The AquaLink
®
RS waits 35
seconds while the valves turn from pool position to spa position (or vice-versa) before activating the fi lter pump.
SERVICE MODE - This message indicates that the PDA Handheld Remote has been locked out from the Power Center and is not operational. Service mode is used by the pool service person to aid them in servicing the pool. The PDA Handheld Remote will not be functional until the switch at the Power Center is moved back to AUTO mode.
SENSOR SHORT - This error message indicates that the sensor is not installed properly or is malfunctioning. Call your pool service person to resolve this problem.
NOTE
If the message reads WATER TEMP SHORT, the heater will not fire. If the message AIR TEMP SHORT is displayed,
freeze protection will not operate correctly.
SPA WILL TURN OFF AFTER COOL DOWN CYCLE - When the system is in Spa Mode (water is circulating to the spa) and the Spa button is pressed to switch water circulation to the pool, the system will not switch to Pool Mode for fi ve minutes, and will continue to circulate the water (if the heater has fi red and has been off for less than fi ve minutes). This delay allows water to cool the heater down by circulating water through it, preventing equipment damage.
TIMEOUT MODE - This message indicates that the PDA Handheld Remote has been locked out from the Power Center and is not operational. TIME OUT mode is used by the pool service person to aid them in servicing the pool. The PDA Handheld Remote will not be functional for three hours, or until the switch at the Power Center is turned back to AUTO mode. The time remaining of TIME OUT mode will appear at the bottom of the PDA screen.
SPILLOVER DISABLED WHILE SPA IS ON - This message is displayed when the spa spillover is pressed while in spa mode (water circulation is to spa). The spillover requires that water circulation is to pool in order to operate. The spillover will activate when the system switches back to pool mode.
Page 40
Section 8. PDA Handheld Remote Menu Flow Chart
MENU
EQUIPMENT ON/OFF
HELP
PROGRAM
SET TEMP
SET TIME
SET AQUAPURE†
PDA OPTIONS
SELECT EQUIPMENT
ALL OFF
SELECT EQUIPMENT
SET MONTH, DAY, YEAR & TIME
SET OUTPUT %
LABEL AUX
SET TIME
AQUAPURE
MODE
FREEZE PROTECTION
AIR TEMP
DEGREES F/C
TEMP CALIBRATE
ADD PROGRAM
DELETE
CHANGE
POOL
††
SPILLOVER
ENABLED DISABLED
SET TEMP
ON
OFF
SET TEMP
SERVICE
DIAGNOSTICS
POOL HEAT
SPA HEAT
CHILL
SET AUTO-OFF
BACKLIGHT
ASSIGN HOTKEYS
SELECT DEVICE
SELECT DEVICE
FAHRENHEIT CELCIUS
LIGHT ON
LIGHT OFF
GENERAL LABELS LIGHT LABELS WTRFALL LABELS CUSTOM LABELS
(TYPE PERSONALIZED
DESCRIPTION)
MODEL
SENSORS
REMOTES
ERRORS
2 MINUTES
5 MINUTES
10 MINUTES
1 2
SELECT LABEL
SYSTEM SETUP
BOOST
SOLAR HEAT PRIORITY
PUMP LOCKOUT
ASSIGN JVAs
COLOR LIGHTS
SPA SWITCH
SERVICE INFO
CLEAR MEMORY
HEAT PUMP
VAR SPEED PUMP
VSP SETTINGS
START
GO BACK
ENABLED DISABLED
SELECT LIGHT TYPE
ENABLED DISABLED
INTAKE RETURN CLEANER SOLAR
ASSIGN TO AUX
1
JANDY EPUMP DC
HEAT MODE
CHILL MODE
JANDY EPUMP AC
INTELLIFLO VF
INTELLIFLO VS
PUMP MODEL
FILTRATION
PUMP APPLICATION
SCALE/MIN-MAX
SELECT PUMP
SELECT PUMP
RPM GPM
AUX. PUMP
NOT INSTALLED
MIN LIMIT
SPEED/LABELS
SELECT PUMP
SET SPEEDS
LABEL SPEEDS
ASSIGN SPEEDS
MAX LIMIT
SELECT A SPEED VALUE
GENERAL LABELS
CUSTOM LABELS
ASSIGN SPEED TO AUX
SELECT
LABEL
Items Seen Only With Optional Equipment
††
Mode Only Displayed When DIP Switch #3 is Set to ON
PRIME
SELECT PUMP
SET SPEED
SET DURATION
SELECT SPEED VALUE
SELECT A DURATION VALUE
Section 9. General, Water Feature, and Light Aux Labels
General Labels Light Labels Waterfall Labels
Aerator Air Blower Backwash Booster Pump Chem Feed Cleaner Color Wheel Drain Line Fan Fiber Optic Fill Line Filter Pump Floor System Fogger Fountain Heat Pump Heater Hi-E2 High Speed Home A/C Home Heat Jet Pump Jandy Lite Lamp Low Speed Mist Music Not Used (see note) Ozonator Pond Ray-Vac Slide Solar Pump Spa Spillway Sprinkler 1 Sprinkler 2 Sprinkler 3 Stereo Stream Swim Jet Timed Aux Valve(s) Wtr Feature Whirlpool
#1 #2 #3 Back Basement Beach Bedroom Bug Cabana Color Wheel Deck Dock Drive East Entry Equipment Fan Fence Flood Fountn Front Garage Garden Gazebo Hall House Kitchen Laminar Plsr Left North Path Patio Perimeter Pond Pool Porch Right Room Sauna Security Shower Shrub South Spa Statue Steps Table Tier Tree Walk Water Ftr Wtrfll West Yard
Page 41
Waterfall Waterfall 1 Waterfall 2 Waterfall 3 Sheer Dscnt Rockfall Laminar Jet
NOTE Please be aware that if the label NOT USED from the GENERAL LABEL menu is used on an AUX relay, the relay will not
engage.
Page 42
NOTES
NOTES
Page 43
LIMITED WARRANTY
®
Thank you for purchasing Jandy free from manufacturing defects in materials and workmanship for a period of one (1) year from the date of retail purchase, with the following exceptions:
• AquaLink
• Never Lube
• AquaPure
®
RS units installed with Jandy Surge Protection Kits will be covered for two (2) years.
®
valves are warranted for the life of the pool and/or spa on which they were originally installed.
®
Electronic Chlorine Generator Electrolytic Cells carry a five (5) year limited warranty on a prorated basis.
• Heat pumps are covered for two (2) years. There is a lifetime warranty on titanium tubing.
• The heat pump compressor is covered for five (5) years.
This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Jandy Pool Products, Inc. shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part, transportation to or from the factory, or any other materials required to make the repair. Refrigerant or other expendables are not covered by the warranty. This warranty does not cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate, or maintain the product(s) in accordance with our pubished Installation, Operation and Maintenance Manuals, which are provided with the product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH levels between 7.2 and 7.8, with ideal ranges being between 7.4 and 7.6, Total Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000, not including salt ppm].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence, or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.
9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-rings, DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.
pool and spa products. Jandy Pool Products, Inc. warrants all parts to be
LIMITATION OF LIABILITY:
This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties on behalf of Jandy Pool Products, Inc. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES,
EXPRESSED OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. JANDY POOL PRODUCTS, INC. EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT, OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty
gives you specific legal rights. You may also have other rights that vary by state or province.
WARRANTY CLAIMS:
For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number, and date of installation. The installer will contact the factory to obtain instructions regarding the claim and to determine the location of the nearest designated service center. If the dealer is not available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at 1.707.776.8200, extension 260. All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty.
H0572300D
ETL LISTED
CONFORMS TO
UL STD 1563
CERTIFIED TO
CAN/CSA C22.2 NO. 218.1
6000 Condor Drive • Moorpark, CA USA 93021 • 707.776.8200 • Fax 707.763.7785
Litho in U.S.A. © Jandy Pool Products, Inc. 0803
PDA HANDHELD REMOTE
FCC ID: S8F826X
PDA TRANSCEIVER
FCC ID: S8F8252
Jandy Pool Products, Inc.
Loading...