Jandy AE-Ti, AE2000, AE2500, AE3000 Installation And Operation Manual

Installation and Operation Data
Installation and Op er a tion Man u al
Jandy® Heat Pumps
Model AE-Ti
DANGER
RISK OF ELECTRICAL SHOCK OR ELECTROCUTION. The electrical supply to this product
must be installed by a licensed or certifi ed electrician in accordance with the National Electrical Code and applicable local codes and ordinances. Improper installation will create an electrical hazard, which could result in death or serious injury to pool or spa users, installers, or others due to electrical shock, and may also cause damage to property. Read and follow the specifi c instructions inside this manual.
DANGER
RISQUE DE CHOC ÉLECTRIQUE OU ELECTROCUTION. Cet appareil doit être installé par un
électricien certifi é conformément au National Electrical Code et aux normes et règlementations locales. Une installation incorrecte peut entraîner un risque de problème électrique ( choc électrique ou électrocution) pouvant causer des blessures graves et même la mort des installateurs et/ou utilisateurs de SPA et Piscines. Lire le manuel et se conformer aux directives.
PELIGRO
RIESGO DE DESCARGA ELÉCTRICA O ELECTROCUTAMIENTO. El suministro eléctrico de
este producto deberá ser instalado por un electricista autorizado o diplomado, de acuerdo al Código Eléctrico Nacional y a los códigos y normativas que apliquen localmente. Una instalación inadecuada podría originar riesgos eléctricos y ocasionar la muerte o lesiones graves a los usuarios de de la piscina o spa, instaladores u otros, como consecuencia de una descarga eléctrica, pudiendo así mismo ocasionar daños a la propiedad. Léa y siga las instrucciones específi cas que se recogen en este manual.
H0569300A
Table of Contents
Page 1
Section 1. General Information ..................2
1.1 Introduction.................................................. 2
1.2 Consumer Information and Safety............... 2
1.2.1 Spa/Hot Tub Safety Rules..................... 2
1.2.2 Swimming Pool Energy Saving Tips ..... 3
1.3 Warranty...................................................... 3
1.4 Codes and Standards.................................. 4
1.5 Technical Assistance ................................... 4
1.6 Materials Needed for Installations ............... 4
1.6.1 Materials for All Installations.................. 4
1.6.2 Recommended Materials for
Installations ........................................... 4
1.7 Specifi cations .............................................. 4
1.7.1 General Specifi cations .......................... 4
1.7.2 Dimensions ........................................... 5
Section 2. Installation Instructions ............5
2.1 General Information..................................... 5
2.2 Location Requirements ............................... 5
2.2.1 Introduction ........................................... 5
2.2.2 Clearances............................................ 6
2.2.3 Equipment Pad...................................... 6
2.2.4 Condensation and Drainage ................. 6
2.2.5 Lawn Sprinklers..................................... 6
2.2.6 Roof Run-Off ......................................... 6
2.2.7 Installation of Anchor Clamps................ 7
Section 3. Water Connections....................7
3.1 Plumbing Layout.......................................... 7
3.2 Water Connections at Heat Pump............... 8
3.3 Check Valve Installation .............................. 8
3.4 Automatic Flow Control Valve ..................... 9
3.5 Multiple Unit Installation .............................. 9
3.5.1 Heat Pump And Heater Combination.... 9
3.5.2 Multiple Heat Pump Connections.......... 9
Section 5. Continued
5.2 Operating the Controller ............................ 18
5.2.1 On/Off Button ...................................... 18
5.2.2 Pool Mode (Normal Heat) ................... 18
5.2.3 Pool Mode (Optional Auto Heat) ......... 19
5.2.4 Spa Mode (Optional Auto Heat).......... 19
5.2.5 Keypad Lockout .................................. 19
5.2.6 Feature Lockout .................................. 19
5.3 Operating Features of Units with
Optional Chiller.......................................... 20
5.3.1 Pool Mode (Normal Cool).................... 20
5.3.2 Pool Mode (Auto Cool)........................ 20
5.3.3 Spa Mode (Auto Cool)......................... 20
5.4 Enabling Remote Control with AquaSwitch
Dual TStat Remote Systems ..................... 20
5.5 Enabling Remote Control with AquaLink
5.6 Advanced Digital Microprocessor
Quick Guide............................................... 21
5.7 Water Pressure Switch Adjustment ........... 21
®
Systems and Other
®
RS Systems ............................ 20
Section 6. General Maintenance .............22
6.1 Water Chemistry........................................ 22
6.2 Winterizing................................................. 22
6.3 Spring Start-Up.......................................... 23
6.4 Inspection and Service .............................. 23
6.4.1 Owner Inspection ................................ 23
6.4.2 Professional Inspection ....................... 24
Section 7. Professional Maintenance
And Service..............................25
7.1 Heat Pump Design .................................... 25
7.2 Heat Pump Components and
Their Operation ......................................... 25
Section 4. Electrical Connections............12
4.1 General Information................................... 12
4.2 Main Power ............................................... 15
4.3 Bonding ..................................................... 15
4.4 Pump Connection (Auto-Heat Feature) .... 16
4.5 Optional Remote Controls ......................... 16
4.5.1 Connection to an AquaLink RS
Control System ................................... 16
Section 5. Operation .................................18
5.1 Initial Start-up Precautions ........................ 18
Section 8. Troubleshooting ......................26
8.1 Troubleshooting Guide .............................. 26
8.2 Diagnostics................................................ 27
Section 9. Replacement Parts..................29
9.1 Ordering Information ................................. 29
9.2 Jandy® AE-Ti Heat Pumps Parts List........ 29
9.3 Jandy® AE-Ti Heat Pumps
Exploded View........................................... 30
Warranty ...................................Back Cover
Page 2
Section 1. General Information
1.1 Introduction
This manual provides installation and operation instructions for the Jandy AE-Ti models of Heat Pumps. Read these installation and operation instructions completely before proceeding with the installation. Consult Jandy with any questions regarding this equipment. To obtain additional copies of this manual contact us at 707-776-8200 ext. 237. The following is the address information for Jandy:
2735 NW 63rd Court.
Fort Lauderdale, FL USA 33309
The AE-Ti heat pump gets electrical power from an external source and provides a dual electronic thermostat control system for pool/spa combinations or preheat convenience.
This heat pump is specifically designed for heating fresh water swimming pools and spas. Do not use it as a general service heater. Consult your dealer for the appropriate Jandy products for these applications.
NOTE “Fresh water swimming pools and spas” include
systems that utilize saltwater chlorine generator units, such as the Jandy AquaPure Electronic Chlorine Generator. Please ensure that the salt content of the pool/spa does not exceed 4000 ppm and water fl ow rate is within 60-80 gpm (225-300 lpm)
ATTENTION
Installation and service must be performed by a qualifi ed installer or service agency.
To the Installer: After installation, these
instructions must be given to the homeowner or left on or near the heat pump.
To the User: This manual contains
important information that will help you in operating and maintaining this heat pump. Please retain it for future reference.
1.2 Consumer Information and Safety
The AE-Ti series of heat pumps are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual and the installation codes referred to in later sections.
Throughout the manual, safety warnings and cautions are identified by the “ “ symbol. Be sure to read and comply with all of the warnings and cautions.
1.2.1 Spa/Hot Tub Safety Rules
WARNING
The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous. Consult heater operation and installation instructions for water temperature guidelines before setting temperature.
AVERTISSEMENT
La Commission U.S. de Sécurité des Produits pour les Consommateurs indique que des températures de l’eau élevées peuvent être dangereuses. Voir la notice d’installation et de fonctionnement pour le réglage de la température.
AVISO
La Comisión de Seguridad de Productos para el Consumidor de los Estados Unidos, advierte que una temperatura elevada del agua puede ser peligrosa. Consulte las instrucciones de instalación y funcionamiento del calentador para seguir las directrices relacionadas con la temperatura del agua antes de proceder a fi jar la temperatura.
WARNING
The following “Safety Rules for Hot Tubs,” recommended by the U.S. Consumer Product Safety Commission, should be observed when using the spa.
AVERTISSEMENT
Les Règlements suivants pour Cuves Thermales, tel que recommandés par la Commission U.S. de Sécurité des Produits pour les Consommateurs, devraient être respectés lors de l’utilisation du spa.
AVISO
Al utilizar el spa, deberán observarse, las siguientes “Reglas de Seguridad para Baños Calientes” recomendadas por la Comisión de Seguridad de Productos para el Consumidor de los Estados Unidos.
Page 3
1. Spa or hot tub water temperature should never exceed 104°F (40°C). One hundred degrees Fahrenheit (100°F [38°C]) is considered safe for a healthy adult. Special caution is recommended for young children.
2. The drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness, and subsequently result in drowning.
3. Pregnant women take note! Soaking in water above 102°F (38.5°C) can cause fetal damage during the fi rst three months of pregnancy (which could result in the birth of a brain-damaged or deformed child). If pregnant women are going to use a spa or hot tub, they should make sure the water temperature is below 100°F (38°C) maximum.
4. The water temperature should always be checked with an accurate thermometer before entering a spa or hot tub. Temperature controls may vary by as much as 1F° (1C°).
5. Persons with a medical history of heart disease, diabetes, circulatory or blood pressure problems should consult their physician before using a hot tub or spa.
6. Persons taking any medication which induces drowsiness (e.g., tranquilizers, antihistamines, or anticoagulants) should not use spas or hot tubs.
7. Prolonged immersion in hot water can induce hyperthermia.
Hyperthermia occurs when the internal body
temperature reaches a level several degrees above the normal body temperature of 98.6°F (37°C). Symptoms include dizziness, fainting, drowsiness, lethargy, and an increase in the internal body temperature. The effects of hyperthermia include:
1.2.2 Swimming Pool Energy Saving Tips
It is important to note that a heat pump will not heat a pool as fast as a large gas or electric pool heater. If the pool water is allowed to cool significantly, it may take several days to return to the desired swimming temperature. For weekend use, it is more economical to maintain the pool water temperature at or near your desired swimming temperature. If you do not plan to use your pool for a prolonged period, then you might choose to turn the heat pump completely off or decrease the temperature setting of the control several degrees to minimize energy consumption.
Jandy offers the following recommendations to help conserve energy and minimize the cost of operating your heat pump without sacrificing comfort.
1. The American Red Cross recommends a maximum
water temperature of 78°F (25°C). Use an accurate
pool thermometer. A difference of 4°F (2°C) ,
between 78°F and 82°F (26°C and 28°C), will
signifi cantly increase energy consumption.
2. Carefully monitor the water temperature of your
pool in the summertime. You can reduce heat
pump usage due to warmer air temperatures.
3. During the winter or when on vacation for longer
than a week, turn off the heat pump.
4. Find the proper setting on the heat pump
temperature control and use the Keypad Lock
function or lock the smoke-colored cover on
the heat pump controller to discourage further
adjustments.
5. Set the pump time clock to start the pump no
earlier than 6:00 AM during the pool heating
season. This is the time when nightly heat loss
balances.
6. Where possible, shelter the pool from prevailing
winds with well-trimmed hedges or other
landscaping, cabanas, or fencing.
Lack of awareness of impending hazard
Failure to perceive heat
Failure to recognize need to leave spa
Physical inability to leave spa
Fetal damage in pregnant women
Unconsciousness resulting in a danger of drowning
7. Always use a pool cover when practical. Besides providing a valuable safety feature, a pool cover will reduce heat loss, conserve chemicals, and reduce the load on fi lter systems.
1.3 Warranty
The AE-Ti heat pump is sold with a limited factory
warranty. Details are specified on the back cover of this manual.
Page 4
Make all warranty claims to an authorized Jandy dealer or directly to the factory. Claims must include the heat pump serial number and model (this information can be found on the rating plate), installation date, and name of the installer. Shipping costs are not included in the warranty coverage.
The warranty does not cover damage caused by improper assembly, installation, operation, winterizing, field modification, or failure to earth bond and properly ground the unit. Any changes to the heat pump, evaporator, heat exchanger, wiring, or improper
installation may void the warranty.
1.4 Codes and Standards
The AE-Ti heat pump is listed by ETL as complying with the latest edition of the “UL Standard for Safety for Heating and Cooling Equipment”, UL 1995 and CSA C22.2 No. 236.
All Jandy heat pumps must be installed in accordance with the local building and installation codes as per the utility or authority having jurisdiction. All local codes take precedence over national codes. In the absence of local codes, refer to the latest edition of the National Electric Code (NEC) in the United States and the Canadian Electric Code (CEC) in Canada for installation.
1.5 Technical Assistance
Consult Jandy Technical Support Department or your local Jandy dealer with any questions or problems involving the specifications, installation, and operation of your Jandy equipment. An experienced technical support staff is ready to assist you in assuring the proper performance and application of Jandy products. For technical support call the Jandy Heat Pumps Technical Service Department at (954) 970-4800
1.6 Materials Needed For Installation
1.6.1 Materials for All Installations
The following items are needed and are to be supplied by the installer for all heat pump installations:
1. Plumbing connections (2”).
NOTE Flex conduit is recommended for connecting
the electrical supply wires to the heat pump so that the front panel may be removed easily for servicing.
4. Electric cutout switch that will interrupt all power to the unit. This switch must be within line of sight of the heat pump.
5. Watertight conduit to run the electrical supply line.
1.6.2 Recommended Materials for Installations
Jandy recommends installing isolation valves on the inlet and outlet water connections for ease of serviceability.
1.7 Specifi cations
1.7.1 General Specifi cations
Installation Location Certified for use in:
USA
Canada
Mexico
Central and South America
Water Pipe/Heater Connection
Plastic 2” PVC (Unions
Flow Rate
Maximum
Optimum
Minimum
Maximum Working Water Pressure
Electrical Supply
Voltage Requirements 1-Phase
Indoor/Outdoor approved Indoor/Outdoor approved Indoor/Outdoor approved Indoor/Outdoor approved
included)
125 gpm (475 lpm) 55 gpm (210 lpm) 30 gpm (110 lpm)
75 psi
208/230 VAC 60Hz
2. Level surface for proper drainage.
3. Suitable electrical supply line. See rating plate on unit for electrical specifi cations. A junction box is not needed at the heat pump; connections are made inside of the heat pump electrical compartment. Conduit may be attached directly to the heat pump jacket.
3-Phase
Amperage Protection Requirements AE2000 AE2500 AE3000
208/230 VAC60 Hz, (Model dependent)
1-Phase 40 A 50 A 50 A
3-Phase 30 A 30 A 30 A
Page 5
33
3.5
10.75
11.5
MODEL
SIZE 2000 38" 26" 22" 13"
2500 42" 30" 26" 17" 3000 42" 30" 26" 17"
Figure 1. Jandy AE-Ti Heat Pumps Dimensions
1.7.2 Dimensions
A
B
DIMENSIONS
"A " "B " "C " "D"
2.2 Location Requirements
36
C
D
See Figure 1 for a diagram showing the heat pump’s dimensions and for dimensions to critical connections.
Section 2. Installation Instructions
2.1 General Information
Install the Jandy heat pumps in accordance with the procedures in this manual, local codes and ordinances, and in accordance with the latest edition of the appropriate national code. (See Section 1.4, “Codes and Standards”.)
Correct installation is required to assure safe operation. The requirements for Jandy heat pumps include the following:
1. Field assembly (if required).
2. Appropriate site location and clearances.
3. Suffi cient air ventilation.
4. Proper electrical wiring.
2.2.1 Introduction
NOTE Indoor installations require special
considerations for condensate drainage and venting the cold air produced by the heat pump. Contact the Jandy Heat Pump Technical Service Department at (954) 970-4800.
CAUTION
When pool equipment is located below the pool surface, a leak from any component can cause large scale water loss or fl ooding. Waterpik Technologies cannot be responsible for such water loss or fl ooding or resulting damage.
ATTENTION
Lorsque l’équipement d’une piscine est situé sous la surface de l’eau, une fuite provenant de n’importe quel élément peut causer une perte d’eau importante ou une inondation. Waterpik Technologies n’est pas responsable des pertes d’eau, des inondations ou des avaries causées par une installation ou un entretien inadéquat.
5. Adequate water fl ow.
This manual provides the information needed to meet these requirements. Review all application and installation procedures completely before continuing the installation.
PRECAUCIÓN
Cuando el equipo de la piscina esté situado por debajo de la superfi cie de la piscina, la fuga de cualquiera de los componentes, podría ocasionar la pérdida de grandes cantidades de agua o inundación. Waterpik Technologies no se responsabilizará de dichas pérdidas de agua o inundaciones, ni de los daños que puedan derivarse de las mismas.
Page 6
Table 1. Heat Pump Clearances
Side of Heat pump
Minimum Clearances for
Operation
Inches Centimeters Inches Centimeters
Front
Rear
Left
Right
To p
6152460
6151230
6151230
6151230
60 150 60 150
Recommended Clearances for
Serviceability
NOTE Clearances listed in
Table 1 are manufacturer ’s
tested values. These are
given as minimum values.
Where local and national
codes apply, and values are
different than those listed in
Table 1, use the greater value
to ensure safe and proper
operation.
Avoid placing the heat pump in locations where it can cause damage by water or condensate leakage. If this is not possible, provide a suitable drain pan to catch and divert any leakage.
All criteria given in the following sections reflect minimum clearances. However, each installation must also be evaluated, taking into account the prevailing local conditions such as proximity and height of walls, and proximity to public access areas.
2.2.2 Clearances
The heat pump must be placed to provide clearances on all sides for maintenance and inspection. See Table 1.
24” (61cm) access in front of the heat pump provides adequate room for serviceability.
If the heat pump is to be installed in a garage or under a vertical overhang, the unit must have a minimum of 5 feet clearance from the top of the heat pump.
This heat pump must be installed at least 5 feet (1.52 meters) from the inside wall of the pool or spa unless the heat pump is separated from the pool or spa by a 5 foot high solid fence or other permanent barrier.
Ce chauffe-piscine doit être installé á au moins 5 pieds (1.5 m) de la paroi interne de la piscine à moins d’être isolé de la piscine par une clôture, un mur ou autre barrière permanente.
Esta bomba de calor deberá instalarse a una distancia de al menos 5 pies (1.5 metros) de la pared interior de la piscina; a menos que la bomba de calentar esté separada de la piscina mediante una valla sólida de 5 pies (1.5 metros) de altura u otra barrera permanente.
2.2.3 Equipment Pad
Place the heat pump on a flat slightly pitched surface, such as a concrete or fabricated slab (pad). This allows proper drainage of condensation and rain water from the base of the unit. If possible, the pad should be placed at the same level or slightly higher than the filter system equipment pad.
NOTE Ensure that the pad is pitched not more than ¼
inch per foot toward the compressor end (front) of the heat pump. Pitch slab from back to front ¼ inch per foot maximum and level from side to side.
2.2.4 Condensation and Drainage
Condensation will occur from the evaporator coil while the unit is running and drain at a steady rate, usually three to five gallons per hour, depending upon ambient air temperature and humidity. The more humid the ambient conditions, the more condensation will be produced. The bottom of the unit acts as a tray to catch rainwater and condensation. Keep the drain hole located on the right side of the base of the unit clear of debris.
If the heat pump is installed indoor a means of condensate disposal must be provided. The drain hole in the base of the heat pump is tapped to fit an optional 5/8” diameter barbed adapter, Jandy p/n R3004100 (see Section 9, “Replacement Parts”. If using the barbed adapter, connect a length of 5/8” tubing or garden hose to the adapter, then route it into a drain or outside the building to dispose of the condensate. It is important
to remember that no part of the tubing or hose may be above the level of the drain hole in the base of the heat pump.
2.2.5 Lawn Sprinklers
Keep lawn sprinkler heads from spraying on the heat pump to prevent corrosion and damage. Use a deflector if needed.
2.2.6 Roof Run-off
Make sure the heat pump is not located where large amounts of water may run-off from a roof into the unit. Sharp sloping roofs without gutters will allow massive amounts of rain water, mixed with debris from the roof to be forced through the unit. A gutter or down spout may be needed to protect the heat pump.
2.2.7 Installation of Anchor Clamps
In Florida, building codes require that the heat pump be anchored to the equipment pad or platform to withstand high wind pressures created during hurricanes.
This heat pump was provided with anchor clamps designed to hold the unit to the equipment pad in high wind conditions. Installation of the anchor clamps is recommended in all installations and are required in Florida (reference Florida Building Code, Mechanical Section 301.13).
To install the anchor clamps:
1. Be sure that the heat pump is in its permanent
location on the equipment pad.
2. Remove the anchor clamps from the installation
and instruction package.
NOTE Bolts and bolt anchors are not included with
the heat pump. Jandy recommends that a 3/16” x 1¾” long stainless steel Tapcon® type concrete screw is used to mount the clamp to the equipment pad. The Tapcon type concrete screw meets Florida building code requirements.
3. Place the clamps at the base of the heat pump in
the locations indicated in Figure 2.
Attach anchor clamps to base of heat pump where indicated by the arrows.
Page 7
Figure 3. Anchor Clamp Installation
6. Drill a hole in the cement using a masonry drill bit, with a diameter as determined by the concrete anchor, at each of the marks on the equipment pad. The hole should be approximately 1-1/2” deep.
7. Insert a bolt anchor into each of the holes. Be sure the anchors are set completely into the holes.
8. Position the anchor clamps so that the holes in the clamps are over the bolt anchors. Be sure that the clamp hooks are over the lip of the heat pump base (see Figure 3).
Figure 2. Anchor Clamp Positions
4. Fit the hook of each clamp over the lip on the base panel of the heat pump. The hook should t between the lip of the base panel and the evaporator coil guard (see Figure 3).
5. Mark the position of the hole in each clamp on the equipment pad.
9. Insert an anchor bolt through each clamp into the anchor and tighten to secure the clamp and heat pump to the equipment pad.
Section 3. Water Connections
3.1 Plumbing Layout
Figure 4 illustrates the standard plumbing layout
with a single heat pump unit. Following the diagram from right to left, the plumbing sequence is as follows:
Pool > Pool Pump > Filter > Heat Pump > Check Valve > Chemical Loop > Chlorinator > Pool
NOTE For normal installations, do not install a shutoff
valve or any kind of variable restriction in the water piping between the heat pump outlet and the pool/spa.
Page 8
CHEMICAL LOOP OR OPTIONAL CHLORINE GENERATION SYSTEM (JANDY AQUAPURE SHOWN)
Sensors
CHEMICAL FEEDER
e r u P a u q A
TO POOL OR SPA
CHECK VALVE
Figure 4. Standard Plumbing Layout
The heat pump must be protected from back­siphoning of water. If there is any chance of back­siphoning, provide a check valve between the pool and the filter pump inlet. Arrangement of pool system components other than as illustrated in the preceding and following diagrams can affect the operation of the heat pump’s water pressure switch. Location of the heat pump above or below the pool water surface can also affect operation of the switch. In general, the pressure switch can be adjusted to accommodate this effect if the heat pump water connections are no more than six feet below the pool water surface or no more than 15 feet above it. See instructions for pressure switch adjustment (Section 5.7) in the heat pump start-up section of this manual for more information. If the heat pump is installed outside of this range, an external flow switch may need to be installed in the plumbing upstream of the heat pump. Call the Jandy Heat Pump Technical Service department at (954) 970-4800 for details.
Be advised that when pool equipment is located below the pool surface a leak can result in large scale water loss or flooding. Jandy cannot be responsible for such water loss or flooding or the damage caused by either occurrence.
3.2 Water Connections at Heat Pump
Shipping plugs have been installed in the water inlet and outlet ports of the heat pump at the factory. Before installing any plumbing, remove the shipping plugs. Filtered water is plumbed to the inlet, located on
the right side of the heat pump front panel. Heated water flows through the outlet, located on the left side of the heat pump front. Two inch unions are provided.
POOL HEATER
FILTER
POOL PUMP
FROM POOL OR SPA
MANUAL BYPASS VALVE
Plastic piping (PVC Schedule 40) should be connected to the heat pump. The unions, provided with the unit, accept 2” PVC pipe.
CAUTION
Make sure that fl ow requirements and pool water turn over rates can be maintained with the installation of additional heat pumps and plumbing restrictions.
ATTENTION
Assurez-vous que la circulation d’eau requise soit maintenue même si des pompes d’appoints ou des éléments de plomberie, causant des restrictions, sont ajoutés.
PRECAUCIÓN
Asegúrese de que los requerimientos de fl ujo e índices de volumen de agua de la piscina puedan mantenerse, con la instalación de bombas de calentar adicionales y restricciones de fontanería.
3.3 Check Valve Installation
The heat pump must be protected from back­siphoning of water. If there is any chance of back­siphoning, provide a check valve between the pool and the filter pump inlet.
When an automatic chemical feeder is installed in the plumbing, it must be installed downstream of the heat pump. A check valve must be installed between the heat pump and the chemical feeder to prevent back­siphoning of chemically saturated water into the heat pump where it will damage the components.
Page 9
3.4 Automatic Flow Control Valve
The inlet/outlet header of the AE-Ti heat pump comes equipped with an internal automatic flow control valve. The automatic flow control valve maintains the proper flow through the heat pump at rates up to approximately 125 gpm (475 lpm). If the filter system flow rate is higher than approximately 125 gpm (475 lpm), install a manual bypass valve (see Figure 4).
NOTE Be advised that if your circulation pump is
over 2 HP or if the total fl ow exceeds 125 gpm, you will have to add an external bypass valve. Excess water fl ow will damage the heat
exchanger.
3.5 Multiple Unit Installation
3.5.1 Heat Pump and Heater Combination
In certain regions of the country it may be more economical to run a heat pump during the warmer months and a gas heater during the cooler months. In some situations it may be desirable to run the heat pump in the “Chiller” mode during the hottest portion of the year and a heater during the cooler months. The Jandy heat pump may be plumbed with a gas or electric heater or any combination of heat sources including solar. All heat sources must be plumbed in parallel to work correctly and efficiently.
Figure 5 illustrates a recommended plumbing layout for a heat pump / heater / solar combination heating system for a pool / spa combination. Your system may not contain all of these components, but the basic plumbing will apply by eliminating the component in the illustration that is not a part of your system.
3.5.2 Multiple Heat Pump Connections
All plumbing on multiple heat pump installations must be done in parallel (see Figures 6 through 9). An equal flow of water to each heat pump is important for optimum operation.
NOTE It may be necessary to adjust water pressure
switch if a unit is installed below the water level. See Section 5.7 for details on when and how to adjust the pressure switch.
NOTE Each heat pump allows a maximum fl ow rate of
125 gpm and requires a minimum of 30 gpm.
POOL INTAKE
SPA INTAKE
POOL RETURN
SPA RETURN
SPA DRAIN
CHECK VALVE
POOL DRAIN
SPA MAKE-UP
FILTER
HEATER
FILTER PUMP
CHECK VALVE
HEAT PUMP
FROM SOLAR
TO SOLAR
Figure 5. Plumbing For Heating System Combinations
Page 10
Extend 12" past end heater inlet for hydraulic balancing
Flow Meter
To Pool
Figure 6. Two Heat Pump Plumbing Layout
12 inches min. clearence around evap.
12"
2" pvc
OPTIONAL
2" Gate Valve Bypass
Minimum 2" pvc pipe
2" pvc
NOTE! Gate Valves are optional on heater inlets but will help system balancing
Extend 12" past end heater inlet for hydraulic balancing
Flow Meter
2" pvc pipe
Pool pump
Extend 12" past end heater inlet for hydraulic balancing
To Pool
2" pvc
3" pvc pipe
3" pvc pipe
Flow Meter
12 inches min. clearance around evap.
12"
2" pvc
2" pvc
3" pvc pipe
3" Gate Valve Bypass
Minimum 3" pvc pipe
NOTE! Gate Valves are optional on heater inlets but will help for system balancing
2" pvc
Extend 12" past end heater inlet for hydraulic balancing
Flow Meter
3" pvc pipe
Pool pump
Figure 7. Four Heat Pump Plumbing Layout
Page 11
12 inches min. clearance around evap.
FLOW METER
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC BALANCING
2" pvc
FLOW METER
2" pvc
FLOW METER
4"PVC PIPE
FLOW METER
TO POOL
Figure 8. Six Heat Pump Plumbing Layout
2" pvc
FLOW METER
4" GATE VALVE BYPASS
12"
NOTE! GATE VALVES ARE REQUIRED ON HEATER INLETS TO HELP SYSTEM BALANCING
2" pvc
FLOW METER
4"PVC PIPE
2" pvc
FLOW METER
2" pvc
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC BALANCING
POOL PUMP
MINIMUM 4"PVC PIPE
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC
2"
pvc
BALANCING
4"pvc
FLOW METER
FLOW METER
2"
pvc
NOTE! GATE VALVES ARE REQUIRED ON HEATER INLETS TO HELP SYSTEM BALANCING
BALANCING VALVES
2"
FLOW METER
FLOW METER
pvc
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC BALANCING
6" PVC
6" PVC
2"
pvc
FLOW METER
GATE VALVE BYPASS
12 inches min. clearance around evap.
TO POOL
MINIMUM 6"PVC PIPE
Figure 9. Eight Heat Pump Plumbing Layout (Dual Headers)
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC BALANCING
4"pvc
POOL PUMP
2"
pvc
FLOW METER
2"
pvc
FLOW METER
2"
pvc
FLOW METER
2"
pvc
EXTEND 16 TO 20" PAST END HEATERS INLET FOR HYDRAULIC BALANCING
12 inches min. clearance around evap.
Page 12
Section 4. Electrical Connections
WARNING
ELECTRICAL SHOCK HAZARD. This heat
pump contains wiring that carries high voltage. Contact with these wires may result in severe injury or death. Disconnect power circuit before connecting the heat pump
AVERTISSEMENT
POSSIBILITÉ DE CHOCS ÉLECTRIQUES.
Ce système de chauffage contient du fi lage de haut voltage. Un contact avec ces fi ls peut résulter en des blessures sérieuses ou la mort. Débranchez le circuit de puissance avant de relier la pompe à chaleur
AVISO
PELIGRO DE DESCARGA ELÉCTRICA.
Esta bomba de calor, contiene cableado de alta tensión. El contacto con los cables podría ocasionar lesiones graves o la muerte. Desconecte el circuito de alimentación, antes de conectar la bomba de calentar.
4.1 General Information
Wiring connections must be made exactly as shown in the wiring diagram found on the inside of the heat pump access panel (see Figure 10 for single phase electrical wiring and Figure 11 for 3-phase electrical wiring). The heat pump must include a definite means of grounding and bonding. There is a bonding lug on the right side of the heat pump, where a bond wire must be attached.
CAUTION
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
ATTENTION
Au moment de l’entretien des commandes, étiquetez tous les fi ls avant de les débrancher. Des erreurs de câblage peuvent entraîner un fonctionnement inadéquat et dangereux.
PRECAUCIÓN
Proceda a etiquetar todos los cables antes de su desconexión en los controles de mantenimiento. Los errores de cableado pueden ocasionar un funcionamiento peligroso e inadecuado. Comprobar que el funcionamiento es correcto, una vez efectuado el mantenimiento.
COMPRESSOR
S
M
CAPACITOR
Page 13
LOAD 1 TO PUMP TIME CLOCK
BR
AUTO-HEAT
CONTACTOR
W
BL
BK
BK
BK
R
W
O
W
MAIN
CONTACTOR
BK
LOAD 2 TO PUMP TIME CLOCK
LINE 2 FROM PUMP TIME CLOCK
LINE 1 FROM PUMP TIME CLOCK
O
Y
O
BK
BK
LINE 1
LINE 2
GROUND
HIGH PRESSURE
SWITCH
R
BK
CRANKCASE
HTR.
OPTIONAL
MODEL AE3000
ONLY
BK
BK
COMPRESSOR
FAN CAPACITOR
BR/W
R
W
BR
Y
BR
FAN MOTOR
OPTIONAL
REVERSING SOLENOID
HEAT / COOL
JVA ACTUATOR PLUGS
BK
W
14151617
J-2HARNESSCONNECTION
W/V
BK/R
W/BR
W
W
BK/W
BKBK
BR
13
BK/BR
RRW
12
BK
PRIMARY (230 VAC)
TRANSFORMER
SECONDARY (24 VAC)
BL
BR
W
BK
11
910
W
BL
BK/G
WATER
SENSOR
BK
BK
Fan
T-8
T-7
DigitalControl
J-2
OR
Y
RBLBLYY
8
J-1HARNESSCONNECTION
O
BK
W/GY
AIR
SENSOR
BL
BL
H20
T-1
T-2
J-1
O
LOW PRESSURE
SWITCH
Com
NO3 NC2
WATER PRESSURE
SWITCH
W
RBL
O
3
Y
BK
Remote
T-6 T-5
1
2
W/R
R
W
A
4567
V
GY
R
R
Air
T-4
T-3
AE SERIE
208/230 VAC
60 Hz
SINGLE PHASE
WIRING DIAGRA
FACTORY WIRED HIGH VOLTAGE
FIELD SUPPLIED HIGH VOLTAGE
FACTORY WIRED
MULTICONDUCTOR CABLE
FACTORY WIRED LOW VOLTAGE
FACTORY WIRED OPTIONAL COMPONENT LOW VOLTAGE
FACTORY WIRED OPTIONAL COMPONENT HIGH VOLTAGE
BK - BLACK BK/BR - BLACK WITH
BROWN TRACE
BK/G -BLACK WITH
GREEN TRACE
BK/R - BLACK WITH
RED TRACE
BK/W - BLACK WITH
WHITE TRACE BL - BLUE BR -BROWN BR/W - BROWN WITH
WHITE TRACE GY - GRAY O - ORANGE R - RED V - VIOLET W - WHITE W/BR - WHITE WITH
W/GY -WHITE WITH
W/R - WHITE WITH
W/V - WHITE WITH
Y - YELLOW
BROWN TRACE
GRAY TRACE
RED TRACE
VIOLET TRACE
H3000200A
Figure 10. AE-Ti Single-Phase Electrical Supply Wiring Diagram
Page 14
COMPRESSOR
FAN CAPACITOR
BR/W
BR
Y
BR
FAN MOTOR
BK
R
W
OPTIONAL
REVERSING SOLENOID
HEAT / COOL
JVA ACTUATOR PLUGS
BK
W
W
14151617
J-2HARNESSCONNECTION
W/V
BK/R
W/BR
LOAD 3 TO PUMP TIME CLOCK
LOAD 1 TO PUMP TIME CLOCK
BR
24V
LINE 1 FROM
L1
PUMP TIME CLOCK
L2
LINE 3 FROM
L3
PUMP TIME CLOCK
24V
BL
L1
L2
MAIN
L3
CONTACTOR
Y
BR
BK
8
910
W
BK
BK/G
WATER
SENSOR
BL
BK
Fan
T-7
T-1
DigitalControl
J-2
W
W
BK/W
BK
R
W
BKBK
13
BR
T1
T2
T3
BK/BR
AUTO-HEAT
CONTACTOR
T1
T2
T3
BK
PRIMARY (230 VAC)
TRANSFORMER
SECONDARY (24 VAC)
BL
W
BR
RRW
11
12
BL
BK
T-8
O
BK
Y
O
W
24V
24V
O
RBLBLYY
BK
O
R
W
BK
BK
BK
4567
J-1HARNESSCONNECTION
W/GY
AIR
SENSOR
BL
T-2
J-1
V
GY
R
R
Air
T-4
T-3
O
H20
CRANKCASE
BK
O
RBL
W
3
2
Y
BK
Remote
T-6 T-5
A
R
HTR.
OPTIONAL
MODEL AE3000
ONLY
BK
HIGH PRESSURE
SWITCH
R
O
LOW PRESSURE
SWITCH
NO3 NC2
WATER PRESSURE
SWITCH
O
1
W/R
W
Com
3-PHASE MONITOR
BK
C
Y
Y
BR
Y-OUT
L3
L2
ON FAULT
CUT WIRE
FOR 50Hz
L1
LINE 1
LINE 2
LINE 3
GROUND
AE SERIES
208/230 VAC
60 Hz
3 - PHASE
WIRING DIAGRAM
FACTORY WIRED HIGH VOLTAGE
FIELD SUPPLIED HIGH VOLTAGE
FACTORY WIRED
MULTICONDUCTOR CABLE
FACTORY WIRED LOW VOLTAGE
FACTORY WIRED OPTIONAL COMPONENT LOW VOLTAGE
FACTORY WIRED OPTIONAL
COMPONENT HIGH VOLTAGE
BK - BLACK BK/BR - BLACK WITH
BROWN TRACE
BK/G - BLACK WITH
GREEN TRACE
BK/R - BLACK WITH
RED TRACE
BK/W - BLACK WITH
WHITE TRACE BL - BLUE BR -BROWN BR/W -BROWN WITH
WHITE TRACE GY - GRAY O - ORANGE R - RED V -VIOLET W - WHITE W/BR -WHITE WITH
BROWN TRACE
W/GY - WHITE WITH
GRAY TRACE
W/R - WHITE WITH
RED TRACE
W/V - WHITE WITH
VIOLET TRACE Y -YELLOW
W
R
BK
H3000300A
Figure 11. AE-Ti 3-Phase Electrical Supply Wiring Diagram
Page 15
4.2 Main Power
Electrical wiring to the heat pump must be in accordance with the latest edition of the National Electric Code (NEC), ANSI/National Fire Protection Association (NFPA) 70 in the United States, and in Canada, the Canadian Electrical Code (CEC) C22.1, unless local code requirements indicate otherwise.
The heat pumps come factory-wired intended for use with either 208/230 VAC, 60 Hz field electrical supply depending on the model. See the rating plate for the electrical specifications. All wiring must be done by a certified electrician.
The following is the procedure to wire the AE-Ti to the electrical source specified on the Rating Plate:
1. Be sure the power to the circuit for the heat pump
is turned off.
2. Remove the 5 screws that attach the service/access
panel to the heat pump unit (see Figure 12).
3. Electrical supply lines must be run through
watertight conduit. Run the wires and conduit from
the power source and connect them to the conduit
connection labeled “High Voltage Connection” on
the right side of the heat pump. See Figure 12 for
connection location.
4. Connect the wires to the terminals on the main
contactor as shown in the wiring diagram.
5. Connect the ground wire to the ground lug
provided in the electrical compartment.
6. Replace the service access panel and replace the screws to hold it in place.
7. Connect a copper bonding wire (8 AWG) to the bonding lug on the right side of the heat pump.
4.3 Bonding
CAUTION
This heater must be connected to a bonding grid with a solid copper wire not smaller in diameter than 8 ga.
ATTENTION
L’appareil de chauffage doit être connecté à une grille de mise à la terre par un fi l de cuivre d’un diamètre de calibre minimal 8.
PRECAUCIÓN
Esta bomba de calor deberá estar conectado a una rejilla de unión con hilo de cobre sólido, de un diámetro no inferior a 8 ga.
The National Electrical Code and most other
codes require that all metallic components of a pool structure, including reinforcing steel, metal fittings, and above ground equipment be bonded together with a solid copper conductor not smaller than 8 AWG. The heat pump, along with pumps and other pool equipment must be connected to this bonding grid. A bonding lug is provided on the right hand side of the heat pump to ensure this requirement is met.
SERVICE ACCESS PANEL (5 SCREWS)
Figure 12. AE-Ti Heat Pump Front View
PORT FOR TIME CLOCK OVERRIDE WIRES
PORT FOR HIGH VOLTAGE WIRES
PORT FOR LOW VOLTAGE WIRES
Page 16
4.4 Pump Connection (Auto-Heat Feature)
(Residential only) When connecting the time clock override parallel circuit, proper phasing must be maintained. Use 12 AWG wire. Follow the wiring diagram on the service access panel of your heat pump, referring to the auto-contactor section (see Figures 10 and ll on pages 13 and 14). The use of four different color wires will help in maintaining the proper phasing to and from the pool pump time clock.
4.5 Optional Remote Controls
Electrical wiring must be in accordance with the latest edition of the NEC (NFPA 70) in the United States and CEC (CSA 22.1) in Canada, unless local code requirements indicate otherwise. To connect remote control equipment to the heat pump, perform the following steps:
1. Turn off the power to both the pool/spa control
system and the heat pump unit.
2. Remove the 5 screws that attach the service/access
panel to the heat pump unit (see Figure 12 on
page 15). This will allow you to access the wires
from the AE-Ti control panel for the remote
control installation (see Figure 13).
3. Run the wires from the pool/spa control system
into the conduit connection labeled “Low Voltage
Connection”, located on the lower right hand side
of the heat pump (see Figures 12 and 14).
4. Strip approximately 1/4” of insulation from the
heat pump remote control wires (black and white,
see Figure 14).
5. Using wire nuts, connect the wiring from the
pool/spa control system to the heat pump remote
control wires.
6. Restore power to the heat pump and the pool/spa
control system.
NOTE For AquaSwitch® or three wire remote controls,
connect the HIGH and COMMON wires to the heat pump remote control wires.
4.5.1 Connection to an AquaLink RS Control System
1. Install a fi xed resistor, with a value of 2.2K Ohms, in the solar sensor terminals #3 and #4 of the green, 10-pin terminal bar of the AquaLink RS Power Center (see Figure 15).
Figure 13. AE-Ti Control Panel, Interior View
Black and White Wires for Remote Control
Figure 14. AE-Ti Control Panel - Remote Control
Wiring
Run Wires from Pool/Spa System through Low Voltage Conduit.
2.2K Ohms Resistor in Solar Sensor Terminals for Heat Pump/Chiller
Gas Heater Connections Terminals 1 and 2
Page 17
To Pressure Switch
Green- Enabled Red- On
4321 654321
LED will not come on for Heat Pump
Heat Pump/Chiller #1
Port for Low Voltage Wires
Service/Wiring Cover Panel
10987654321
Standard High Voltage Relay
Figure 15. AquaLink RS to AE-Ti Heat Pump/Chiller Wiring
Battery (9Volt)
Low Voltage Wiring to Low Voltage Port on Heat Pump
Fireman's Switch
From Fusible Link
Heat Pump/Chiller #2
Port for Low Voltage Wires
Gas Heater
Service/Wiring Cover Panel
NOTE One end of the wiring reserved to run into
the conduit connection labeled “Low Voltage Connection”, located on the lower right hand side of the heat pump (see Figures 12 and 14).
2. Run the wires from the Heat Pump control panel through the wiring conduit located on the outer right hand side of the Heat Pump.
3. In the AquaLink Power Center, connect the Heat Pump to a standard relay, then connect the relay to the solar pump output on the PCB. Set the time to 11:59 PM; at 12:00 AM, the AquaLink RS will auto-relabel Solar as Heat Pump. Otherwise, the AquaLink RS will auto-relabel Solar as Heat Pump within 24 hours.
4. The Solar Button will activate the heat pump/ chiller and the Pool and/or Spa Heater Buttons will activate the gas heater. In this manner the pool or spa can be heated or chilled by the heat pump, the gas heater or both.
Page 18
Section 5. Operation
CAUTION
Do not use this heat pump if any part has been under water. Immediately call a qualifi ed service technician to inspect the heater and replace any part of the control system which has been under water.
ATTENTION
N’utilisez pas cet appareil s’il a été plongé dans l’eau, même partiellement. Faites inspecter l’appareil par un technicien qualifi é et remplacez toute partie du système de contrôle et toute commande qui ont été plongés dans l’eau.
PRECAUCIÓN
No utilice esta bomba de calor si algunos de sus componentes han estado debajo del agua. Póngase inmediatamente en contacto con un técnico de mantenimiento cualifi cado para que inspeccione el equipo y reemplace cualquier parte del sistema de control que haya estado debajo del agua.
CAUTION
Keep all objects off the top of the heat pump. Blocking air fl ow could damage the unit and may void the warranty.
Be sure that there is water in the pool and that the surface level is above the skimmer or other inlet of the pool’s filter system.
With any new pool or spa installation, operate the filter pump with the heat pump off long enough to completely clean the water. This will remove any installation residue from the water. Clean the filter at the end of this operation before starting the heat pump. When raising the temperature of a cold pool, program the time clock to run the pump continuously. This lets the filter system and heat pump operate continuously until the water reaches the temperature setting on the temperature control. When that happens, the heat pump will automatically shut off, but the filter pump will keep running.
5.2 Operating the Controller
Your new AE-Ti heat pump is controlled by an advanced microprocessor based controller that provides a sophisticated yet simple interface to operate your heat pump for maximum efficiency and enjoyment of your pool. To locate the control buttons, see Figure 16.
5.2.1 Off/On Button
When the control panel is turned off, the screen displays CONTROL IS OFF and the Off/On LED indicator is not lit. Press panel. The LED will light and the display will read
PLEASE SELECT POOL OR SPA.
5.2.2 Pool Mode - (Normal Heat)
Off/On to turn on the control
ATTENTION
Ne posez aucun objet sur le dessus de l’appareil. Il pourrait empêcher la circulation de l’air, ce qui risquerait d’endommager l’appareil et d’annuler la garantie.
PRECAUCIÓN
Mantenga todos los objetos fuera de la parte superior de la bomba de calor. La obstrucción del fl ujo de aire podría dañar la unidad y anular la garantía.
5.1 Initial Start-up Precautions
ATTENTION
After starting the AE-Ti heat pump, please note that there is a 5 minute delay before the compressor begins operation. The heat pump display will show the remaining delay time in minutes.
To enable the pool mode, press POOL. The LED indicator will light and the unit will display
TEMPERATURE SET-POINT = XX°
NOTE XX represents the current temperature setting
on the control. The default setting for pool temperature is 82°F.
POOL
for 5 seconds.
After 5 seconds the unit will display POOL
HEAT and the current pool temperature. You can
change the temperature set point by pressing the
Down button. The display will change back to
or
Up
show POOL TEMPERATURE SET-POINT = XX°.
Repeatedly press the Up or Down
button until you reach the desired temperature set point. After 5 seconds of inactivity, the new set point is stored in memory. When the water temperature falls to 1 degree below
the temperature setting
and after a 5- minute delay, the
control will start the heat pump.
Page 19
Figure 16. Main Control Panel
5.2.3 Pool Mode - (Optional Auto Heat)
If connected, the Auto-Heat mode allows the heat pump to monitor the temperature of the water 24 hours a day by turning the pool pump on and sampling the water temperature. When the water temperature drops below the programmed temperature set point, the control will start the heat pump.
To operate in pool mode with the Heat Auto­Run feature, press
POOL, then press Time/Auto. The
LED indicators on both buttons will light and the unit will display POOL TEMPERATURE SET-POINT =
XX°
for 5 seconds. Change the temperature set point
by pressing the
Up or Down buttons until the desired
set point is displayed. After 5 seconds of inactivity the unit will display
POOL AUTO-HEAT along with the
current pool temperature and the delay time remaining until the heat pump starts.
5.2.4 Spa Mode - (Optional Auto Heat)
If connected, the spa mode automatically enables the Auto-Run feature. Press SPA to enable spa mode. The LED indicator will light and the unit will display
SPA TEMPERATURE SET-POINT = XX° for 5
seconds. Change the temperature set point by pressing the Up or Down buttons until the desired set point is displayed. After 5 seconds of inactivity the display will read SPA AUTO-HEAT along with the current spa temperature and the delay time left until the heat pump starts. Additionally, the new set point will be stored in memory. The default factory setting for Spa temperature is 104 degrees.
5.2.5 Keypad Lockout
To lockout the keypad in any operating mode,
press and hold the POOL, SPA, and Heat/Cool buttons for 6 seconds. All control buttons will be disabled and the control will operate in the mode it was in when the keypad lockout occurred. If any button is pressed when the keypad is in lockout mode, the unit will display
SYSTEM LOCKED for 5 seconds. To unlock the
keypad, press and hold the buttons for 6 seconds. The unit will display
UNLOCKED
.
POOL, SPA, and Heat/Cool
SYSTEM
5.2.6 Feature Lockout
To lockout all features except the On/Off, POOL
SPA buttons in any operating mode, press and
and hold the Time/Auto, Heat/Cool and Down buttons for 6 seconds. All control buttons except the On/Off,
POOL
and SPA will be disabled. If any button is
pressed when the keypad is in feature lockout mode, the unit will display FEATURE LOCKED for 5 seconds. To unlock the keypad, press and hold the Time/Auto,
Heat/Cool
and Down buttons for 6 seconds. The unit
will display FEATURE UNLOCKED.
Page 20
5.3 Operating Features of Units with Optional Chiller
5.3.1 Pool Mode - (Normal Cool)
To operate in Pool-Cool mode, press POOL. The
LED indicator will light and the unit will display the message for 5 seconds.
HEAT and the current pool temperature. Press Heat­Cool SET-POINT = XX°
set point by pressing the Up or Down buttons until the desired set point is displayed. After 5 seconds of inactivity, the display will read with the current pool temperature and the delay time remaining until the chiller starts. Additionally, the new set point will be stored in memory. When the water temperature rises to 1 degree above the temperature
setting will turn on the chiller circuit.
the temperature of the water 24 hours a day. When the temperature of the water rises above the desired temperature setting, the control will then energize the unit.
Run feature, press light and the unit will display the message POOL
TEMPERATURE SET-POINT = XX°
HEAT and the current pool temperature. Press Heat­Cool SET-POINT = XX°
button will light. The display will read POOLCOOL along with the current pool temperature and the delay time remaining until the chiller starts.
TEMPERATURE SET-POINT = XX°
and the LED on the button will light. Change the setting using the Up or Down buttons until you reach the desired set point. After 5 seconds of inactivity, the unit will display POOL AUTO-COOL and the current pool temperature.
indicator will light on the SPA and the Time/Auto buttons and unit will display SPA TEMPERATURE
SET-POINT = XX°
using the Up or Down buttons until you reach the
POOL TEMPERATURE SET-POINT = XX°
After 5 seconds the display will read POOL
. The unit will display POOL TEMPERATURE
for 5 seconds. You can change the
POOL-COOL along
and after a time delay of 5 minutes, the control
5.3.2 Pool Mode - (Auto Cool)
The Auto-Cool mode allows the unit to monitor
To operate in pool mode with the Cooling Auto-
POOL. The LED indicator will
for 5 seconds.
After 5 seconds the display will read POOL
. The unit will display POOL TEMPERATURE
for 5 seconds and the LED on the
Press Time-Auto. The unit will display POOL
for 5 seconds
5.3.3 Spa Mode - (Auto Cool)
To operate in Spa Cool mode press SPA. The LED
for 5 seconds. Change the setting
desired set point. After 5 seconds of inactivity the display will read
SPA AUTO-HEAT along with the
current spa temperature and the delay time left until the chiller starts. Additionally, the new set point will be stored in memory.
Heat/Cool. The Heat/Cool LED will light
Press
and the display will read SPA TEMPERATURE SET-
POINT = XX°
the
Up or Down buttons until you reach the desired set
point. The display will read
for 5 seconds. Change the setting using
SPA AUTO-COOL along
with the current water temperature after 5 seconds of inactivity. The new set point will be stored in memory.
5.4 Enabling Remote Control with AquaSwitch Systems and All Other Dual TStat Remote Systems
NOTE Temperature setting for Pool or Spa are set at
the heat pump.
1. Turn off the control panel.
2. Press and hold the
Time/Auto, Up and Down
arrow buttons for 5 seconds to enter the setup menu. The control panel will momentarily display
SETTING 01 then it will display the language that
is used for the display.
NOTE In this mode, pressing and releasing the SPA
button will step though each setting in the setup menu. Each press of the SPA button will cause the display to momentarily show the setting number then show the value for that setting. Pause between button presses to allow the control time to respond.
3. Repeatedly press and release the SPA button until
the display momentarily reads control panel will then display
DISABLED.
SETTING 05. The
AQUASWITCH
4. Press the Up arrow button one time to enable
remote control of the unit. The control panel will then display
AQUASWITCH ENABLED.
5. Press and hold the Time/Auto, Up and Down
arrow buttons for 5 seconds to exit the setup menu.
5.5 Enabling Remote Control with AquaLink RS Systems
NOTE Temperature setting for Pool or Spa are set at
the Aqualink RS indoor controller.
1. Turn off the control panel.
Page 21
2. Press and hold the Time/Auto, Up, and Down
arrow buttons for 5 seconds to enter the setup menu. The control panel will momentarily display
SETTING 01 then it will display the language that
is used for the display.
NOTE In this mode, pressing and releasing the SPA
button will step though each setting in the setup menu. Each press of the SPA button will cause the display to momentarily show the setting number then show the value for that setting. Pause between button presses to allow the
control time to respond.
3. Repeatedly press and release the SPA button until
the display reads will then display
4. Press the
Up arrow button one time to enable
SETTING 13. The control panel
AQUALINK DISABLED.
remote control of the unit. The control panel will then display
AQUALINK ENABLED.
5. Press and hold the Time/Auto, Up and Down
arrow buttons for 5 seconds to exit the setup menu.
5.6 Advanced Digital Microprocessor Quick Guide
To operate your heat pump, simply select, then press the buttons corresponding to the operating mode you want to use. The associated LED indicator will light.
1. Press
2. Select
3. The heat pump will run consistent with pool time
4. The optional Heat/Cool feature is used with
Off/On to turn heat pump on or off.
POOL or SPA. The heat pump control
panel will display the current pool or spa
temperature setting. Adjust the temperature set
point up or down as desired.
clock for the pump. Press
Time/Auto to enable
the optional Auto-Heat. The heat pump will
override the time clock and maintain/monitor the
pool temperature 24 hours a day. To maintain the
temperature, the heat pump will turn on at night.
Reverse Cycle equipped heat pumps. Press Heat/
Cool
to reverse roles from heating to cooling the
pool to the desired temperature.
5.7 Water Pressure Switch Adjustment
CAUTION
The water pressure switch should be adjusted to turn the heater off when the pump is off. Setting the switch to close at too low of a fl ow can damage the appliance. Adjust the switch to turn the heater off, not on.
ATTENTION
Le manocontact de pression d’eau doit être réglé de façon à ce que l’appareil cesse de fonctionner si la pompe s’arrête. Si le manocontact est réglé pour se fermer lorsque le débit d’eau est trop faible, l’appareil risque de s’endommager. Réglez le manocontact pour qu’il arrête l’appareil, et non pour qu’il le mette en marche.
PRECAUCIÓN
El interruptor de la presión del agua, deberá ajustarse de forma que el calentador se apague cuando se apague la bomba. La calibración del interruptor para que pueda apagarse con fl ujos demasiado bajos podría estropear el equipo. Ajuste el interruptor para apagar el calentador, no para encenderlo.
The pressure switch is preset at the factory for activation at 2 psi (14 kPa). This is the minimum setting for the water pressure switch and works for all basic installations as shown previously in Section
3.1 and Section 3.5 in this manual. Only adjust the water pressure switch if the heat pump does not operate when the proper flow is applied to unit or if the heat pump does not shut off when the filter pump is off. Occasionally, unusual plumbing configurations or necessary restrictions in the plumbing may cause pressure sensing problems. In these rare situations, the plumbing system configuration may require adjustment of the water pressure switch.
Adjustment of the pressure switch may be necessary if any part of the filter system piping is 3 feet (0.91 m) or more above the top of the heat pump jacket.
Do not adjust the pressure switch if the heat pump is installed more than 15 feet (4.57 m) above or 6 feet (1.83 m) below the pool surface. Consult your local Jandy representative for recommendations.
Page 22
On some installations, the piping from the heat pump to the pool is very short. The back pressure could be too low to trigger the pressure switch. If this happens, it may be necessary to install a directional fitting or elbows where the return line enters the pool. This will increase back pressure enough for the heat pump to operate properly. If this configuration is necessary, be sure to check that the system flow is above the minimum requirement of 30 gpm after the direction fitting or elbow has been installed.
Make sure the pool filter is clean before making any pressure switch adjustment: A dirty filter will restrict the water flow and the pressure switch cannot be adjusted properly.
To adjust the pressure switch:
1. Be sure that all valves in the system are set to
allow water fl ow through the heat pump. Start the
lter pump.
2. Set the heat pump control to call for heat. Set the
On/Off switch on the heat pump control to the
ON position. If the heat pump was installed with
the Auto-Heat feature, set the mode to TIME so
that the heat pump will turn on if water is fl owing
through the heat exchanger.
3. If the heat pump control displays “LOW H
O
2
FLOW”, then the fl ow in the system may be below
the minimum fl ow of 30 gpm needed for the safe
operation of the heat pump. Investigate and correct
any fl ow problems before adjusting the water
pressure switch.
4. Remove the heat pump’s control access panel. The
water pressure switch is located in the lower left
corner of the control compartment.
5. After confi rming the fl ow rate is at a minimum
of 30 gpm, slowly rotate the thumb wheel on
the water pressure switch in a counterclockwise
direction until the “LOW H2O FLOW” indicator
disappears from the control display. Remember
that there is a time delay before the heat pump
compressor will start.
6. Once the heat pump is running, turn off the fi lter
pump. The heat pump should turn off immediately.
7. If the heat pump continues to operate when the
lter pump is off, turn the thumb wheel on the
water pressure switch in a clockwise direction
until “LOW H
O FLOW” is displayed on the
2
control and the heat pump shuts down.
8. Check the setting of the water pressure switch by starting and stopping the fi lter pump and checking the control display and operation of the heater between each fl ow change.
9. If the water pressure switch cannot be adjusted to accommodate the conditions listed above, an external fl ow switch must be added to the plumbing system to ensure that the heat pump will not operate without the proper fl ow through the heat exchanger.
Section 6. General Maintenance
6.1 Water Chemistry
Proper chemical balances are necessary for
sanitary bathing conditions as well as ensuring your heat pump’s long life. Be sure to keep your chemical and mineral concentration levels within the values indicated in Table 2.
NOTE For spas, it is also necessary to perform water
changes in addition to chemical treatment. It is recommended to change the spa water every 60 days for light usage and every 30 days if usage is heavy.
6.2 Winterizing
CAUTION
Failure to winterize could cause damage to the heat pump and will void the warranty.
ATTENTION
La garantie sera annulée si l’appareil n’est pas hivernisé convenablement.
PRECAUCIÓN
La falta de acondicionamiento de la bomba de calor para el invierno podía causar daños y anular la garantía.
In areas where freezing temperatures occur, you
should protect your pump, filter, and heat pump from the elements. Perform the following steps to completely drain the heat pump (see Figure 17).
1. Turn off the electrical power to the heat pump at the main breaker panel.
2. Shut off the water supply to the heat pump.
3. Disconnect the water inlet and outlet unions located on the lower front panel of the heat pump.
Page 23
Table 2. Optimal Water Chemistry Ranges
Test Recommended Level
Free Chlorine or 1.0 to 3.0 ppm (3.0 to 5.0 spa)
Bromine 2.0 to 4.0 ppm (3.0 to 5.0 spa)
pH 7.4 to 7.6
Total Alkalinity (TA) 80 to 120 ppm
Calcium Hardness (CH) 200 to 400 ppm
Cyanuric Acid 30 to 50 ppm
Total Dissolved Solids (TDS) Less than 2000 ppm
Copper 0 ppm
* Concentration levels taken from “Basic Pool and Spa Technology” published by NSPI (National Spa and Pool Institute).
Water Inlet Union
Water Outlet Union
Figure 17. Winterizing the AE-Ti Heat Pump
4. Open the drain located on the lower front panel of the heat pump to drain the remaining water from the heat exchanger. Leave the drain open until the unit is ready for seasonal start-up.
5. Cover only the top of the heat pump to prevent debris from falling into the unit. Do not wrap the sides of the heat pump with any plastic or other material that will retain heat or moisture inside the unit.
6.3 Spring Start-Up
If your heat pump has been winterized, perform
the following steps when starting the system in the Spring:
1. Uncover the heat pump and inspect the top and sides for any debris or structural problems.
2. Close the petcock located on the lower front panel of the heat pump.
Petcock (Leave open until unit is ready to start-up)
4. Turn on the fi lter pump to supply water to the heat pump. Circulate water through the system long enough to cycle all of the pool water through the fi lter. Check for leaks in and around the heat pump.
5. Turn on the electrical power to the heat pump at the main breaker panel.
6.4 Inspection and Service
Jandy Heat Pumps are designed and constructed
to provide long performance life when installed and operated properly under normal conditions. Periodic inspections are important to keep your heat pump running safely and efficiently through the years.
6.4.1 Owner Inspection
Jandy recommends that you inspect your heat
pump on a continual basis and especially after abnormal weather conditions. The following basic guidelines are suggested for your inspection:
3. Connect the water inlet and outlet unions located on the lower front panel of the heat pump.
1. Keep the top and surrounding areas of the heat pump clear of all debris.
Page 24
2. Keep all plants and shrubs trimmed and away from the heat pump.
3. Do not use this heat pump if any part has been under water. Immediately call a qualifi ed professional technician to inspect the heat pump and replace any part of the control system which has been submerged.
The heat pump will produce condensation (water)
while in operation. The heat pump base is designed to allow the condensation to exit through the bottom drain port when the unit is running. The condensation will increase as the outdoor air humidity level increases. Check the following at regular intervals to ensure proper condensate drainage:
1. Visually inspect and clear the bottom drain ports of any debris that could clog the ports.
2. Ensure that condensate water does not puddle inside the heat pump
3. Ensure that condensate run-off is properly directed away from the equipment pad to keep it from undermining the pad.
During normal operation, the heat pump
produces three to five gallons of condensate per hour. If condensate drainage is above this range during operation or if water continues to drain from the base when the heat pump is not in operation for more than an hour, a leak in the internal plumbing may have occurred. Call a qualified heat pump technician to investigate the problem.
Keep the top air flow discharge and air flow intake
area clear of debris so the air flow though the heat pump is not restricted. The cooler discharge air from the top should not accumulate and be drawn into the side air intake coils. Keep all plants and shrubs trimmed away from the heat pump.
Make sure the front of the unit is accessible for
future service.
Keep lawn sprinkler heads from spraying on the
heat pump to prevent corrosion and damage. Use a deflector if needed.
If the unit is installed under a very sharp roof pitch
or under a roof without a gutter, a gutter or diverter should be fitted to prevent excessive water from pouring down into the unit.
6.4.2 Professional Inspection
Inspections performed at least once a year by a qualified technician are required to maintain your heat pump’s safe and efficient operation. The following basic safety checks must be performed.
1 Check for loose or broken wires and terminal
connections.
2. Verify the pressure switch operation. Turn the heat
pump OFF. Disconnect the power to the pump
time clock, or turn the pump time clock to an OFF
position. Turn the heat pump back ON. The heat
pump must not come on.
3. Inspect the electrical controls, specifi cally the
following:
a. High and Low limits
b. Pressure switch
c. Temperature control
4. Inspect the evaporator coil for blockage and clean
as necessary.
5. Check for spider webs or debris in the condensate
drain; clean if necessary.
6. Conduct a normal operating cycle and observe that
the unit operates properly.
Section 7. Professional Maintenance and Service
7.1 Heat Pump Design
The Jandy Air Energy Heat Pump is one of the most efficient ways to heat a pool or spa. The heat pump transfers heat from the outside air to the pool or spa water by means of an internal heat exchanger.
When the fan is turned on, warm air is drawn through the refrigerant charged evaporator, turning the cold liquid refrigerant to a warm gas. The gas then flows through the compressor where it is compressed resulting in a much higher temperature.
The hot gas enters the heat exchanger where the water extracts the heat. The pump pulls in cool pool water, which in turn converts the hot gas back into a liquid refrigerant and starts the cycle over again.
NOTE The maximum heat output and effi ciency of a
heat pump is dependent upon the quality and performance of the major components used. As equally important are the environmental conditions (for example, air temperature, humidity, water temperature, and wind).
Page 25
Figure 18. Heat Pump Operation Overview
7.2 Heat Pump Components and Their
Operation
Evaporator Heat is collected in the evaporator
similar to a solar collector, which is a basic design
for collecting heat. The larger the surface area of
the evaporator, the more heat it can collect.
Fan The Heat Pump fan produces high volume airfl ow.
Adequate airfl ow is required to transfer warm air
to the large evaporator.
Compressor The compressor compresses the
refrigerant gas to a higher pressure, thus increasing
the temperature.
Heat Exchanger As the fi nal step to the heating
process, the heat exchanger transfers the heat
from the hot gas to the water. (Also known as a
condenser.)
Reversing Valve (For Units with Optional
Chiller) The reversing valve reverses the fl ow of
the refrigerant, which results in transferring cold
gas to the water, thus lowering the temperature.
Page 26
Section 8. Troubleshooting
8.1 Troubleshooting Guide
SYMPTOM CORRECTIVE ACTION
Heat pump will not start, no control board display. Breaker or fuse may be tripped. Reset breaker or check
fuse. If heat pump still does not run, call for service.
Heat pump will not start, control board display working. Heat pump may be in delay count down of 5 minutes
Make sure control board thermostat is calling for heater to come on (check setting on thermostat and temperature reading.) Make sure heat pump is not in cooling mode.
Heat pump runs but does not heat. Verify cold air is blowing out the top of the heat pump. If
the heat pump has just been installed or if the pool water has been allowed to cool significantly, it is necessary to run the heat pump continually for 24-48 hours. If the heat pump has been in operation for some time, increase the circulating pump time, or switch the control board to auto heat function. If heating a spa, verify no air intake stand pipes are open. If heat pump still does not heat call for service.
Heat pump does not run and control board displays LOW H2O FLOW.
Heat pump does not run and control board display shows HIGH REFRIGERANT PRESSURE.
Heat pump does not run or short cycles and control board display shows LOW REFRIGERANT PRESSURE.
Heat pump leaking water. Possible heat exchanger or plumbing leak. Turn the
Verify circulating pump is on and all necessary valves are in the correct positions. Verify filter and skimmers are clean. Check water level in pool. Temporarily turn off all fountains and water falls that bypass the heat pump water inlet. If this does not correct the problem, call for service.
Verify circulating pump is on and that there are no water flow restrictions to the heat pump. Make sure all necessary valves are open or in the proper positions to allow proper water flow to the heat pump. Verify filter and skimmers are clean. Check for water level in the pool. This condition may also appear if the heat pump has not been operated for an extended period. To clear the condition, cycle the heat pump, on and off, up to 3 times. If this does not correct the problem call, for service.
Check that fan is operating and air is coming out of the top of the heat pump, while short cycling. If heat pump does not run at all, call for service.
heat pump off, then turn circulating pump on for at least one hour to see if the water leak stops. If the water leak stops, normal condensation is occurring. If the water leak continues, after the heat pump is shut off for at least one hour, call for service.
Page 27
8.2 Diagnostics
In the event a pressure switch opens or another fault condition occurs, the LCD screen will display
the fault until the problem has been resolved. Please refer to the following table for the list of diagnostic conditions.
Diagnostic Condition Description
LOW H2O FLOW Low or restricted water flow through the heat pump.
The external bypass valve is in the wrong position, or the water flow switch has malfunctioned. The water flow switch opens creating a fault and the heat pump shuts off.
The LCD screen will display LOW H2O FLOW on the top line until the switch closes. The ON LED will flash once every 2 seconds.
LOW COIL TEMPERATURE When the evaporator coil temperature is below 30°F, the heat pump
cannot operate effectively.
The coil thermistor reads the temperature and the control goes into defrost if the defrost mode is not set to OFF in setup mode.
The LCD display will display LOW COIL TEMP on the top line for the duration of the low coil temperature condition when the defrost mode is set to OFF. When set to either Air Defrost or Reversing Valve Defrost, the LCD display will show * Defrost Mode * for the duration of the low coil temperature condition.
LOW REFRIGERANT PRESSURE When the ambient temperature is low, the suction pressure can
drop significantly.
This fault will cause the low pressure switch to open and the control will shut off the compressor.
The LCD display will display LOW REFRIGERANT on the top line and PRESSURE on the bottom line for the duration of the fault condition. The ON LED will flash twice every 2 seconds.
HIGH REFRIGERANT PRESSURE When the head pressure builds too high, the high pressure switch
will open causing the heat pump to shut off immediately.
The control will sense this fault condition and shut off the compressor until the switch re-closes.
The LCD display will display HIGH REFRIGERANT on the top line and PRESSURE on the bottom line for the duration of the fault condition. The ON LED will flash 3 times every 2 seconds.
HIGH WATER TEMPERATURE When the POOL or SPA water temperature heats to the maximum
allowed temperature or above, there could be safety risks for anyone in the water.
The water thermostat will read this temperature and the control will shut off the heat pump unless it is in CHILLER mode.
The LCD display will display HIGH H20 on the top line and TEMPERATURE on the bottom line for the duration of the fault condition. This feature also remains active when the control calls for heat through a remote thermostat. This is to insure that water temperature does not go to an abnormally high level due to a possible malfunction of the remote sensor.
Page 28
Diagnostic Condition Description
LOW WATER TEMPERATURE When the POOL or SPA temperature chills to 50°F or below there
could be safety risks for anyone in the water.
The water sensor will read this temperature and the control will shut off the chiller.
The LCD display will show LOW H2O on the top line and TEMPERATURE on the bottom line for the duration of the fault condition. This feature also remains active when the control calls for chill through a remote thermostat. This is to insure that water temperature does not go to an abnormally low level due to a possible malfunction of the remote sensor.
COIL SENSOR PROBLEM In the event that the coil temperature sensor malfunctions or is not
connected the control will shut off the heat pump.
The LCD display will show COIL SENSOR on the top line and MALFUNCTION on the bottom line until the problem is resolved.
WATER SENSOR PROBLEM In the event that the water temperature sensor malfunctions or is
not connected the control will shut off the heat pump.
The LCD display will show WATER SENSOR on the top line and MALFUNCTION on the bottom line until the problem is resolved.
Section 9. Replacement Parts
9.1 Ordering Information
To order or purchase parts for the AE-Ti models of heat pumps, contact your nearest Jandy dealer or distributor. See the Jandy web site at www.jandy.com
9.2 Jandy AE-Ti Heat Pumps Parts List
Page 29
for the nearest service center. If they cannot supply you with what you need, contact Jandy Customer Service Department at P.O. Box 6000, Petaluma, California, 94954, Telephone (707) 776-8200 extension 245.
Key No. Description
1 Top Enclosure, Jacket All R3000200 2 Front Panel, Jacket 2000 R3000401 2 Front Panel, Jacket 2500,3000 R3000403 3 Service Access Panel All R3000500 4 Control Cover - Smoked All R3000600 5 Fan Motor, 208 VAC & 230 VAC All R3000701 5 Fan Motor, 380 VAC & 460 VAC All R3000702 6 Contactor, 1-Phase All R3000801 6 Contactor, 3-Phase All R3000802 7 Transformer, 1-Phase All R3000901 7 Transformer, 3-Phase All R3000902 8 Water Pressure Switch All R3001000 9 Capacitor, Fan Motor All R3001100 10 Capacitor, Compressor (55/440) Bristol 2000 R3001201 10 Capacitor, Compressor (60/370) Bristol 2500 R3001202 10 Capacitor, Compressor (80/370) Bristol 3000 R3001203 11 Controller Assembly All R3001300 12 Refrigerant HP Switch All R3001400 13 Refrigerant LP Switch All R3001500 14 Wire Harness Kit, 1-Phase (Not Shown) All R3001600 15 Fan Blade Set All R3001700 16 Fan Guard All R3001800 17 Plumbing Bypass Assembly All R3001900 18 2” PVC Union Set All R3002000 19 Evaporator Coil/Guard 2000 R3002101 19 Evaporator Coil/Guard 2500 R3002102 19 Evaporator Coil/Guard 3000 R3002103 20 Heat Exchanger Drain Kit All R3002200 21 Heat Exchanger Replacement Kit All R3002300 22 Compressor (55/440), 1-Phase 2000 R3002500 22 Compressor (60/370), 1-Phase 2500 R3002600 22 Compressor (80/370), 1-Phase 3000 R3002700 22 Compressor, 3-Phase 2000 R3003400 22 Compressor, 3-Phase 2500 R3003500 22 Compressor, 3-Phase 3000 R3003600 23 Thermal Expansion Valve
(Heating only, Not Shown)
23 Thermal Expansion Valve
(Reversing opt., Not Shown) 24 Water Temperature Sensor All R3002900 25 3-Phase Monitor All R3003000 26 Air Temperature Sensor All R3003100 27 Reversing Valve (Optional, Not Shown) 2500, 3000 R3003800 28 Achor Bracket Set (Not Shown) All R3003203 29 Heat Pump Drain Kit All R3004100
Model No.
All R3002801
2500, 3000 R3002802
Order Part No.
Page 30
9.3 Jandy AE-Ti Heat Pumps Exploded View
16
24, 26
This 10K thermistor is used as a water temperature sensor when installed in the water inlet pipe and as an air temperature sensor when installed in the evaporator coil.
Please note that the water temperature sensor wiring is blue and the air temperature sensor wiring is red.
12
RED WIRE
BLUE W
IRE
These pressure switches are installed in the refrigerant line near the compressor.
YELLO
ORANGE WIRE
WWIRE
13
4
1
11
15
5
21
19
22
25
6
7
10
2
17
18
20
9
8
3
Notes
Page 31
Page 32
Notes
Page 33
LIMITED WARRANTY
Thank you for purchasing Jandy® pool and spa products. Waterpik Technologies (manufacturer of Jandy
®
products, including Laars
pool and spa heaters, Air Energy Heat Pumps, and Clormatic Electronic Chlorine Generators) warrants all parts to be free from manufacturing defects in materials and workmanship for a period of one year from the date of retail purchase, with the following exceptions:
AquaLink
NeverLube® valves are warranted for the life of pool and/or spa on which they were originally installed.
AquaPureTM Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.
Heat pump titanium coils carry a limited lifetime warranty.
®
RS units installed with Jandy Surge Protection Kits will be covered for two years.
This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have been moved from their original installation sites. The liability of Waterpik Technologies shall not exceed the repair or replacement of defective parts and does not include any costs for labor to remove and reinstall the defective part, transportation to or from the factory, and any other materials required to make the repair. This warranty does not cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,
Operation and Maintenance Manuals provided with the product(s).
2. The workmanship of any installer of the product(s).
3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total
Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000].
4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.
5. Scaling, freezing, or other conditions causing inadequate water circulation.
6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.
7. Use of non-factory authorized parts or accessories in conjunction with the product(s).
8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing
sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.
9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,
DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.
LIMITATION OF LIABILITY:
This is the only warranty given by Waterpik Technologies. No one is authorized to make any other warranties on Waterpik Technologies' behalf. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED
OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. WATERPIK TECHNOLOGIES EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL, INCIDENTAL, INDIRECT OR PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. This warranty gives you specific
legal rights. You may also have other rights which vary by state or province.
WARRANTY CLAIMS:
For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, model number, serial number and date of installation. The installer will contact the factory for instructions regarding the claim and to determine the location of the nearest designated service center. If the dealer is not available, you can locate a service center in your area by visiting www.jandy.com or by calling our technical support department at (707) 776-8200 extension 260 [for heap pumps call (954) 970-4800]. All returned parts must have a Returned Material Authorization number to be evaluated under the terms of this warranty.
ETL LISTED
CONFORMS TO
UL STD 1995
CERTIFIED TO
H0569300A
CAN/CSA C22.2 NO.236
6000 Condor Drive • Moorpark, CA USA 93021
2735 NW 63rd CT• Fort Lauderdale, FL USA 33309
A Waterpik Technologies Company
• 707.776.8200 • Fax 707.763.7785
• 954.970.4800 • Fax 954.971.8440
Litho in U.S.A. © Waterpik Technologies 0501