INSTALLATION INSTRUCTIONS
PRESSURE BALANCE VALVE WITH DIVERTER
Part Number: J-DIV-PBV
Confidence from start to finish.
™
JACLO.COM
PRESSURE BALANCE VALVE WITH DIVERTER PG 1
jac lo in du st ri es 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133
INSTALLATION
1. Turn off water supply.
2. Install valve, making sure valve is in proper position.
Make sure “Up” outlet is facing up and hot water is
connected on left side and cold is connected on
right. Be sure to use a thread sealant or teflon tape
on all threaded connections.
3. A plastic roughing shield is installed on the valve to
insure proper roughing depth and to protect valve
during construction.
4. Connect shower and tub spout piping to valve. Be
sure to flush lines before making final installation of
shower head or tub spout.
5. Unscrew the screws on the plastic plate and remove the
plastic plate. Mount gasket onto the back of face plate.
Install the diverter handle into the diverter hole of the
face plate. Secure the diverter handle by threading the
nut onto the face plate as illustrated. Position the face
plate onto the valve body and lightly thread the longer
screws provided. Please see (Fig. 4)
6. If either a shower head or tub spout connection is
not used, install a 1/2” plug in the corresponding outlet.
7. Be sure to test for leaks and proper function
before closing wall.
8. Install trim
Open
Close
Min 24”
Figure 4
Longer Screw
Face Plate
Gasket
Up
Min 1-3/4”
Max 2-5/8”
1-5/8”
Floor Line
66”
+
-
/
1/4”
SETTING LIMIT STOP
1. The valve temperature limit is preset at the factory to
prevent scalding.
2. To reset the limit stop, remove the handle, then remove
the red limit stop by pulling off with pliers
3. To reset the limit stop to a higher temperature, re-install
the limit stop ring to the left or original position (Fig A)
by rotating it more to the left (Figures B & C).
4. Failure to properly install the limit stop ring can cause
possible scalding by water that is too hot.
JACLO.COM
PRESSURE BALANCE VALVE WITH DIVERTER PG 2
jac lo in du st ri es 129 Dermody Street Cranford, NJ 07016
p 908.653.4433 | 800.852.3906 f 908.653.1717 | 800.852.4133
Red Knob
Limit Stop
A
B
C