Jackson TEMPSTAR SDS Service Manual

Page 1
INSTALLATION/OPERATION
& TECHNICAL MANUAL
ELECTRICALLY HEATED MODELS:
TEMPSTAR
TEMPSTAR LT
TEMPSTAR NB
TEMPSTAR SDS
STEAM HEATED MODELS:
Jackson MSC, LLC.
P.O. BOX 1060
HWY. 25E
BARBOURVILLE, KY. 40906
PHONE (606) 523-9795
FAX (606) 523-9196
www.jacksonmsc.com
TEMPSTAR SERIES UPRIGHT DOOR DISHMACHINES
December 07, 2007 P/N 7610-011-86-35 (Revision K)
Page 2
Page 3
ALL NEW JACKSON DISHWASHERS ARE WARRANTED TO THE ORIGINAL PURCHASER TO BE FREE FROM DEFECTS IN MATERIAL OR WORKMANSHIP, UNDER NORMAL USE AND OPERATION FOR A PERIOD OF (1) ONE YEAR FROM THE DATE OF PURCHASE, BUT IN NO EVENT TO EXCEED (18) EIGHTEEN MONTHS FROM THE DATE OF SHIPMENT FROM THE FACTORY.
Jackson MSC agrees under this warranty to repair or replace , at its discretion, any original part which fails under normal use due to faulty material or workmanship during the warranty period, providing the equipment has been unaltered, and has been properly installed, main­tained and operated in accordance with the applicable factory instruction manual furnished with the machine and the failure is reported to the authorized service agency within the warranty period. This includes the use of factory specified genuine replacement parts, purchased directly from a Jackson authorized parts distributor or service agency. Use of generic replacement parts may create a hazard and void war­ranty certification.
The labor to repair or replace such failed part will be paid by Jackson MSC, within the continental United States, Hawaii and Canada, during the warranty period provided a Jackson MSC authorized service agency, or those having prior authorization from the factory, performs the service. Any repair work by persons other than a Jackson MSC authorized service agency is the sole responsibility of the customer. Labor coverage is limited to regular hourly rates, overtime premiums and emergency service charges will not be paid by Jackson MSC.
Accessory components not installed by the factory carry a (1) one year parts warranty only. Accessory components such as table limit switch­es, pressure regulators, pre rinse units, etc. that are shipped with the unit and installed at the site are included. Labor to repair or replace these components is not covered by Jackson MSC.
This warranty is void if failure is a direct result from shipping, handling, fire, water, accident, misuse, acts of god, attempted repair by unau­thorized persons, improper installation, if serial number has been removed or altered, or if unit is used for purpose other than it was origi­nally intended.
TRAVEL LIMITATIONS
Jackson MSC limits warranty travel time to (2) two hours and mileage to (100) one hundred miles. Jackson MSC will not pay for travel time and mileage that exceeds this, or any fees such as those for air or boat travel without prior authorization.
WARRANTY REGISTRATION CARD
The warranty registration card supplied with the machine must be returned to Jackson MSC within 30 days to validate the warranty.
REPLACEMENT PARTS WARRANTY
Jackson replacement parts are warranted for a period of 90 days from the date of installation or 180 days from the date of shipment from the factory, which ever occurs first.
PRODUCT CHANGES AND UPDATES
Jackson MSC reserves the right to make changes in design and specification of any equipment as engineering or necessity requires.
THIS IS THE ENTIRE AND ONLY WARRANTY OF JACKSON MSC. JACKSON’S LIABILITY ON ANY CLAIM OF ANY KIND, INCLUDING NEGLIGENCE, WITH RESPECT TO THE GOODS OR SERVICES COVERED HEREUNDER, SHALL IN NO CASE EXCEED THE PRICE OF THE GOODS OR SERVICES OR PART THEREOF WHICH GIVES RISE TO THE CLAIM.
THERE ARE NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING FOR FITNESS OR MERCHANTABILITY, THAT ARE NOT SET FORTH HEREIN, OR THAT EXTEND BEYOND THE DURATION HEREOF. UNDER NO CIRCUMSTANCES WILL JACKSON MSC BE LIABLE FOR ANY LOSS OR DAMAGE, DIRECT OR CONSEQUENTIAL, OR FOR THE DAMAGES IN THE NATURE OF PENALTIES, ARISING OUT OF THE USE OR INABILITY TO USE ANY OF ITS PRODUCTS.
ITEMS NOT COVERED
This warranty does not cover cleaning or deliming of the unit or any component such as, but not limited to, wash arms, rinse arms or strain­ers at anytime. Nor does it cover adjustments such as, but not limited to timer cams, thermostats or doors, beyond 30 days from the date of installation. In addition, the warranty will only cover the replacement of wear items such as curtains, drain balls, door guides or gaskets during the first 30 days after installation. Also, not covered are conditions caused by the use of incorrect (non-Commercial) grade detergents, incorrect water temperature or pressure, or hard water conditions.
MANUFACTURERS WARRANTY
ONE YEAR LIMITED PARTS & LABOR WARRANTY
3
Page 4
4
STOP! PARE!
ARRET!
CALL 1-888-800-5672 TO REGISTER THIS PRODUCT!
FAILURE TO DO SO WILL VOID THE WARRANTY!
LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO!
AL NO HACERLO LA GARANTIA SERA ANULADA!
S.V.P. APPELER 1-888-800-5672 POUR ENREGISTRER CE PRODUIT,
LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON- ENREGISTREE
Page 5
i
REVISION
REVISION
DATE
MADEBYAPPLICABLE
ECN
DETAILS
F 05-14-04 MAW
6964 7006
Changed thermostat. Changed thermostat mounting bracket. Change to new layout. Added note for “wye configuration”.
G 01-05-05 MAW
7084 6690 7180
Added Overflow Lift Brackets. Added Right False Panel Weldment used with overflow tube lifter. Added universal False Panel Weldment for Tempstars. Update Tempstar Top Mount 460V Schematic to revision D. Added “GO*BOX” Kit.
H 01-17-06 MAW 7609
Added schematics and parts for Universal Timers to be used in Top Mount Control Boxes Only.
I 02-07-06 MAW 7231
Added thermostat replacement kit 06401-011-66-55. Replaced rinse thermostat 05930-121-71-29 with 05930-510-03-79.
J 06-26-06 MAW
7687, 7540 7738, 7789
7571
Update to current layout. Added phase conversion instructions and service kits. Changed hood supports and added hood block spacers. Added numbers for plumbing assemblies. Updated drain quench assembly drawing. Replaced 05930-121-67-72 with 05930-510-02-79.
K 12-07-07 MAW Process
Combined I/O & Technical manuals. Updated schematics to include exhaust fan/dispenser connections. Updated control boxes with multicycle switches. Corrected number for reed switch and cantilever support brackets.
Page 6
ii
NOMENCLATURE FOR THE MODELS COVERED IN THIS MANUAL
Model:
Serial No.:
Installation Date:
Service Rep. Name:
Phone No.:
TEMPSTAR NB
TEMPSTAR = Electrically heated, high temp, hot water sanitizing, with booster heater, door-type dish­machine TEMPSTAR LT = Electrically heated, low temp, chemical sanitizing, no rinse booster, door-type dish­machine TEMPSTAR NB = Electrically heated, high temp, hot water sanitizing, no rinse booster, door-type dish­machine TEMPSTAR S = Steam heated, high temp, hot water sanitizing, door-type dishmachine TEMPSTAR SDS = Electrically heated, high temp, with solid chemical dispenser, with booster heater, door­type dishmachine
Jackson MSC LLC. provides technical support for all of the dishmachines detailed in this manual. We strongly recommend that you refer to this manual before making a call to our technical support staff. Please have this manual with you when you call so that our staff can refer you, if necessary, to the prop­er page. Technical support is available from 8:00 a.m. to 5:00 p.m. (EST), Monday through Friday. Technical support is not available on holidays. Contact technical support toll free at 1-888-800-
5672. Please remember that technical support is available for service personnel only.
Page 7
Section
Description Page
I. Specifications
Operating Capacities 2 Electrical Requirements 3 Dimensions Tempstar/Tempstar LT/Tempstar NB (Side Mounted Control Box) 4 Dimensions Tempstar/Tempstar LT/Tempstar NB (Top Mounted Control Box) 5 Dimensions Tempstar SDS 6 Table Dimensions 7
II. Installation/Operation Instructions
Installation Instructions 9 Electrical Installation Instructions 10 Operation Instructions 11 Detergent Control 12 False Panel Installation 13
III. Preventative Maintenance 15
IV. Troubleshooting Section 17
V. Drawing/Parts Section
Top Mounted Control Box Assembly (Universal Timer) 20 Top Mounted Control Box Assembly (Mechanical Timer) 22 Side Mounted Control Box Assembly 24 SDS Control Box Assembly 26 Hood Assembly 28 Hood Assembly (Bolted Single Support Design) 29 Cantilever Arm/Door Assemblies 30 Tub Assembly 32 Steam Tub Assembly 34 Frame Assembly 36 Rinse Tank Assembly 37 Coil Assembly 38 Incoming Steam Plumbing Assembly 39 Wash Motors 40 Motor & Pump Assembly 41 Wash Heaters/Rinse Heaters 42 Incoming Plumbing/Outlet Plumbing Assembly 43 WPRK Kit Option 44 Tempstar LT & Tempstar NB Incoming Plumbing Assembly 45 Tempstar SDS Incoming Plumbing Assembly 46 3/4” Solenoid Valve & 3/4” NPT Vacuum Breaker Repair Parts Kits 47 Wash and Rinse Arm/Manifold Assemblies 48 Tempstar SDS Dispenser Assembly 50 Safety Door Interlock (SDI)/Exhaust Fan Control/Transformer Mounting Box Components 55 False Panel Installation 56 GO*BOX Kit 57 Drain Quench Assembly 58
TABLE OF CONTENTS
iii
Page 8
VI.A Electrical Diagrams - Top Mounted Control Boxes
Tempstar (UT w/Cycle Switches) 208 - 230V, 50/60 Hz, single/three phase 60 Tempstar (UT w/Cycle Switches) 460V, 60 Hz, three phase 61 Tempstar LT & NB (UT w/Cycle Switches) 208 - 230V, 50/60 Hz, single/three phase 62 Tempstar LT & NB (UT w/Cycle Switches) 460V, 60 Hz, three phase 63 Tempstar (Universal Timer) 208 - 230V, 50/60 Hz, single/three phase 64 Tempstar (Universal Timer) 380/440/460V, 50/60 Hz, three phase 65 Tempstar LT & NB (Universal Timer) 208 - 230V, 50/60 Hz, single/three phase 66 Tempstar LT & NB (Universal Timer) 380/415/440/460V, 50/60 Hz, three phase 67 Tempstar (Mechanical Timer) 208 - 230V, 50/60 Hz, single/three phase 68 Tempstar (Mechanical Timer) 380/440/460V, 50/60 Hz, three phase 69 Tempstar (Mechanical Timer) 415V, 50/60 Hz, three phase, five wire 70 Tempstar LT & NB (Mechanical Timer) 208 - 230V, 50/60 Hz, single/three phase 71 Tempstar LT & NB (Mechanical Timer) 380/415/440/460V, 50/60 Hz, three phase 72 Tempstar S (Mechanical Timer) 208 - 230V, 60 Hz, single/three phase 73 Tempstar S (Universal Timer) 208 - 230V, 60 Hz, single/three phase 74
VI.B Electrical Diagrams - Side Mounted Control Boxes
Tempstar (Side Mount) 208 - 230V, 50/60 Hz, single/three phase 76 Tempstar (Side Mount) 380V, 50 Hz, three phase 77 Tempstar (Side Mount) 440/460V, 50/60 Hz, three phase 78 Tempstar LT & Tempstar NB (Side Mount) 208 - 230V, 50/60 Hz, single/three phase 79 Tempstar LT & Tempstar NB (Side Mount) 380/440/460V, 50/60 Hz, three phase 80 Tempstar SDS 208 - 230V, 60 Hz, single/three phase 81 Tempstar SDS 380/440/460V, 50/60 Hz, three phase 82 Tempstar SDS 380/415V, 50 Hz, three phase, 5 wire 83 Tempstar SDS Dispenser 85
VI.C Electrical Diagram Options
Safety Door Interlock (SDI) 86 Drain Quench 87 Exhaust Fan Control 87
VII. Jackson Maintenance & Repair Centers 89
TABLE OF CONTENTS
iv
Page 9
1
SECTION 1:
SPECIFICATION INFORMATION
Page 10
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
OPERATING CAPACITIES
PERFORMANCE/CAPABILITIES
OPERATING CAPACITY:
RACKS PER HOUR 57 DISHES PER HOUR 1425 GLASSES PER HOUR 1425
OPERATING CYCLE (SECONDS):
MINIMUM (OTHER CYCLE TIMES ARE AVAILABLE)
WASH TIME 45 RINSE TIME 11 DWELL TIME 2 TOTAL CYCLE TIME 60
TANK CAPACITY:
WASH TANK (GAL) 8.0 WASH TANK (L) 30.3 RINSE TANK (TEMPSTAR/TEMPSTAR SDS) (GAL) 3.0 RINSE TANK (TEMPSTAR/TEMPSTAR SDS) (L) 11.4
STEAM REQUIREMENTS:
COIL SIZE 3/4” STEAM FLOW PRESSURE (P.S.I.) 10-20 CONSUMPTION @ 15 P.S.I. (LBS/HR) 45
ELECTRICAL REQUIREMENTS
WASH MOTOR HP 3/4
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.
WATER REQUIREMENTS
TEMPSTAR/TEMPSTAR SDS:
WASH TEMPERATURE (MINIMUM)(°F) 150 WASH TEMPERATURE (MINIMUM)(°C) 66 RINSE TEMPERATURE (MINIMUM)(°F) 180 RINSE TEMPERATURE (MINIMUM)(°C) 83 INLET WATER TEMPERATURE:
12KW RINSE HEATER (°F) 140 12KW RINSE HEATER (°C) 60 14KW RINSE HEATER (°F) 110
14KW RINSE HEATER (°C) 44 FLOW PRESSURE (PSI) 20±5 WATER LINE SIZE (NPT) 3/4” DRAIN LINE SIZE (NPT) 1 1/2”
TEMPSTAR LT:
WASH TEMPERATURE (MINIMUM)(°F) 130 WASH TEMPERATURE (MINIMUM)(°C) 55 RINSE TEMPERATURE (MINIMUM)(°F) 130 RINSE TEMPERATURE (MINIMUM)(°C) 55 INLET WATER TEMPERATURE (°F) 130 INLET WATER TEMPERATURE (°C) 55 FLOW PRESSURE (PSI) 20±5 WATER LINE SIZE (NPT) 3/4” DRAIN LINE SIZE (NPT) 1 1/2” MINIMUM CHLORINE REQUIRED (PPM) 50
TEMPSTAR NB/TEMPSTAR S:
WASH TEMPERATURE (MINIMUM)(°F) 150 WASH TEMPERATURE (MINIMUM)(°C) 66 RINSE TEMPERATURE (MINIMUM)(°F) 180 RINSE TEMPERATURE (MINIMUM)(°C) 83 INLET WATER TEMPERATURE (°F) 180 INLET WATER TEMPERATURE (°C) 83 FLOW PRESSURE (PSI) 20±5 WATER LINE SIZE (NPT) 3/4” DRAIN LINE SIZE (NPT) 1 1/2”
2
Page 11
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
TEMPSTAR/TEMPSTAR SDS:
RINSE TYPICAL HEATER TOTAL ELECTRICAL
VOLTS
PH HZ RATINGS AMPS CIRCUIT
208 1 50 12KW@240V 71 A 90 AMP 208 1 50 14KW@240V 78 A 100 AMP 230 1 50 12KW@240V 78 A 100 AMP 230 1 50 14KW@240V 86 A 110 AMP
208 3 50 12KW@240V 45 A 60 AMP 208 3 50 14KW@240V 49 A 70 AMP 230 3 50 12KW@240V 48 A 60 AMP 230 3 50 14KW@240V 53 A 70 AMP 380 3 50 12KW@380V 29 A 40 AMP 380* 3 50 14KW@208V 34 A 45 AMP 415 3 50 12KW@415V 26 A 35 AMP 415 3 50 14KW@415V 29 A 40 AMP 440 3 50 12KW@460V 21 A 30 AMP 440 3 50 14KW@460V 25 A 35 AMP
208 1 60 12KW@240V 69 A 90 AMP 208 1 60 14KW@240V 76 A 100 AMP 230 1 60 12KW@240V 76 A 100AMP 230 1 60 14KW@240V 84 A 110 AMP
208 3 60 12KW@240V 43 A 60 AMP 208 3 60 14KW@240V 47 A 60 AMP 230 3 60 12KW@240V 46 A 60 AMP 230 3 60 14KW@240V 51 A 70 AMP 460 3 60 12KW@480V 22 A 30 AMP 460 3 60 14KW@480V 25 A 35 AMP
* This model is wired in a wye configuration for the heaters.
TEMPSTAR LT/TEMPSTAR NB:
RINSE TYPICAL HEATER TOTAL
ELECTRICAL
VOLTS
PH HZ RATINGS AMPS CIRCUIT
208 1 50 N/A 28 A 35 AMP 230 1 50 N/A 30 A 40 AMP
208 3 50 N/A 20 A 25 AMP 230 3 50 N/A 21 A 30 AMP 380 3 50 N/A 10 A 15 AMP 415 3 50 N/A 10 A 15 AMP 440 3 50 N/A 8 A 15 AMP
208 1 60 N/A 26 A 35 AMP 230 1 60 N/A 28 A 35 AMP
208 3 60 N/A 18 A 25 AMP 230 3 60 N/A 28 A 35 AMP 460 3 60 N/A 8 A 15 AMP
TEMPSTAR S:
RINSE TYPICAL HEATER TOTAL
ELECTRICAL
VOLTS PH HZ RATINGS AMPS CIRCUIT
208 1 60 N/A 6 A 15 AMP 230 1 60 N/A 6 A 15 AMP
208 3 60 N/A 6 A 15 AMP 230 3 60 N/A 6 A 15 AMP
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than what is displayed here. Always verify with your electrical service contractor that your circuit protection is ade­quate and meets all applicable national and local codes. These numbers are provided in this manual simply for ref­erence and may change without notice at any given time.
Page 12
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
DIMENSIONS TEMPSTAR/TEMPSTAR LT/NB (SIDE MOUNTED CONTROL BOX)
4
25 1/4” (64.1 cm)
32” (81.3 cm)
17 1/2” (44.5 cm)
MACHINE OPENING
10 5/8”
(27 cm)
34” (86.4 cm)
TABLE
HEIGHT
14”
(35.6 cm)
61 3/4” (156.8 cm) WATER INLET TO
FLOOR
A- WATER INLET (3/4” NPT) B- ELECTRICAL CONNECTION POINT
C- DRAIN (1 1/2” NPT) D- STANDARD CLEARANCE BETWEEN
MACHINE AND WALL (WITH DISHTABLE) IS 4” (10.2 cm).
D
A
B
D
C
15 1/2” (39.4 cm)
76” (193 cm)
W/ DOOR
OPEN
LEGEND:
Page 13
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
DIMENSIONS TEMPSTAR/NB/LT/S (TOP MOUNTED CONTROL BOX)
5
25 1/4” (64.1 cm)
32” (81.3 cm)
17 1/2”
(44.5 cm) MACHINE OPENING
34” (86.4 cm)
TABLE
HEIGHT
76” (193 cm)
W/ DOOR OPEN
14”
(35.6 cm)
DRAIN
TO
FLOOR
64 3/8”
(163.5 cm)
60 5/8”
(154 cm)
61 3/4”
(156.8 cm)
WATER
INLET TO
FLOOR
A- WATER INLET (3/4” NPT) B- ELECTRICAL CONNECTION POINT C- DRAIN (1 1/2” NPT)
D- STANDARD CLEARANCE BETWEEN
MACHINE AND WALL (WITH DISHTABLE) IS 4” (10.2 cm).
D
A
B
B
D
C
15 1/2” (39.4 cm)
LEGEND
4 7/8” (12.4 cm)
Page 14
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
DIMENSIONS TEMPSTAR SDS
6
25 1/4” (64.1 cm)
32” (81.3 cm)
74”
(188 cm)
17 1/2”
(44.5 cm) MACHINE OPENING
7 1/4”
(18.4 cm)
34”
(86.4 cm)
TABLE
HEIGHT
76” (193 cm)
W/ DOOR OPEN
14”
(35.6 cm)
61 3/4”
(156.8 cm)
WATER
INLET TO
FLOOR
A- WATER INLET (3/4” NPT) B- ELECTRICAL CONNECTION POINT C- DRAIN (1 1/2” NPT)
D- STANDARD CLEARANCE BETWEEN
MACHINE AND WALL (WITH DISHTABLE) IS 4” (10.2 cm).
E- CHEMICAL DISPENSING SYSTEM
D
A
B
D
E
C
15 1/2” (39.4 cm)
Page 15
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
TABLE DIMENSIONS
7
TABLE DIMENSIONS
CORNER INSTALLATION
TABLE DIMENSIONS
CONNECTION TO DISHMACHINE
TABLE DIMENSIONS
STRAIGHT
THROUGH INSTALLATION
20 1/2” (52.1 cm)
OPENING
25 1/4”
(64.1 cm)
2 1/2” (6.4 cm)
4” (10.2 cm)
MINIMUM
2 1/2”
(6.4 cm)
4” (10.2 cm) MINIMUM
20 1/2” (52.1 cm)
OPENING
25 1/4”
(64.1 cm)
20 1/2” (52.1 cm)
3/4” (1.9 cm)
1 1/2” (3.81 cm) ROLL
4” (10.2 cm)
MINIMUM
2 1/2”
(6.4 cm)
25 1/4”
(64.1 cm)
20 1/2” (52.1 cm)
OPENING
25 1/4” (64.1 cm)
Page 16
8
SECTION 2:
INSTALLATION/OPERATION
INSTRUCTIONS
Page 17
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
9
VISUAL INSPECTION: Before installing the unit, check the container and machine for damage. A damaged container is an indi­cator that there may be some damage to the machine. If there is damage to both the container and machine, do not throw away the container. The dishmachine has been inspected and packed at the factory and is expected to arrive to you in new, undamaged condition. However, rough handling by carriers or others may result in there being damage to the unit while in transit. If such a sit­uation occurs, do not return the unit to Jackson; instead, contact the carrier and ask them to send a representative to the site to inspect the damage to the unit and to complete an inspection report. You must contact the carrier within 48 hours of receiving the machine. Also, contact the dealer through which you purchased the unit.
UNPACKING THE DISHMACHINE: Once the machine has been removed from the container, ensure that there are no missing parts from the machine. This may not be obvious at first. If it is discovered that an item is missing, contact Jackson immediately to have the missing item shipped to you.
LEVEL THE DISHMACHINE: The dishmachine is designed to operate while being level. This is important to prevent any damage to the machine during operation and to ensure the best results when washing ware. The unit comes with adjustable bullet feet, which can be turned using a pair of channel locks or by hand if the unit can be raised safely. Ensure that the unit is level from side to side and from front to back before making any connections.
PLUMBING THE DISHMACHINE: All plumbing connections must comply with all applicable local, state, and national plumbing codes. The plumber is responsible for ensuring that the incoming water line is thoroughly flushed prior to connecting it to any com­ponent of the dishmachine. It is necessary to remove all foreign debris from the water line that may potentially get trapped in the valves or cause an obstruction. Any valves that are fouled as a result of foreign matter left in the water line, and any expenses resulting from this fouling, are not the responsibility of the manufacturer.
CONNECTING THE DRAIN LINE: The drain for the Tempstar models covered in this manual are gravity discharge drains. All pip­ing from the 1 1/2” FNPT connection on the wash tank must be pitched (1/4” per foot) to the floor or sink drain. All piping from the machine to the drain must be a minimum 1 1/2” I.P.S. and shall not be reduced. There must also be an air gap between the machine drain line and the floor sink or drain. If a grease trap is required by code, it should have a flow capacity of 5 gallons per minute.
WATER SUPPLY CONNECTION: Ensure that you have read the section entitled “PLUMBING THE DISHMACHINE” above before proceeding. Install the water supply line (3/4” pipe size minimum) to the dishmachine line strainer using copper pipe. It is recommended that a water shut-off valve be installed in the water line between the main supply and the machine to allow access for service.
The water supply line is to be capable of 20 ±5 PSI “flow” pressure at the recom­mended temperature indicated on the data plate.
In areas where the water pressure fluctuates or is greater than the recommended pres­sure, it is suggested that a water pressure regulator be installed. The Tempstar models covered in this manual come with water pressure regulators as standard equipment. Please notify Jackson immediately if this component is not present on your machine.
Do not confuse static pressure with flow pressure. Static pressure is the line pressure in a “no flow” condition (all valves and ser­vices are closed). Flow pressure is the pressure in the fill line when the fill valve is opened during the cycle.
It is also recommended that a shock absorber (not supplied with the Tempstar model) be installed in the incoming water line. This prevents line hammer (hydraulic shock), induced by the solenoid valve as it operates, from causing damage to the equipment.
STEAM LINE CONNECTION: The steam machines come with lines by which the source steam needs to be connected. Connect all steam lines to the machine as all applicable codes provide. See machine data plate for information concerning steam flow pres­sure.
CHEMICAL DISPENSING EQUIPMENT: The Tempstar LT machine requires that a separate chemical feeder be connected to it to provide the required detergent and sanitizer. This feeder needs to be able to operate against a head of 25 PSI and provide 1.79 ml of a 10% Chlorine sanitizer per minute.
Frame with Adjustable Foot
Raise
Lower
Incoming Plumbing Y-strainer Connection
Page 18
PLUMBING CHECK: Slowly turn on the water supply to the machine after the incoming fill line and the drain line have been installed. Check for any leaks and repair as required. All leaks must be repaired prior to placing the machine in operation.
ELECTRICAL POWER CONNECTION: Electrical and grounding connections must comply with the applicable portions of the National Electrical Code ANSI/NFPA 70 (latest edition) and/or other electrical codes.
Disconnect electrical power supply and place a tag at the disconnect switch to indi­cate that you are working on the circuit.
The dishmachine data plate is located on the right side and to the front of the machine. Refer to the data plate for machine operating requirements, machine volt­age, total amperage load and serial number.
To install the incoming power lines, open the control box. This will require taking a phillipshead screwdriver and removing the four (4) screws on the front cover of the control box. Install 3/4” conduit into the pre-punched holes in the back of the con­trol box. Route power wires and connect to power block and grounding lug. Install the service wires (L1, L2, and L3 (3 phase only)) to the appropriate terminals as they are marked on the terminal block. Install the grounding wire into the lug pro­vided. Tighten the connections. It is recommended that “DE-OX” or another similar anti-oxidation agent be used on all power connections.
VOLTAGE CHECK: Ensure that the power switch is in the OFF position and apply power to the dishmachine. Check the incoming power at the terminal block and ensure it corresponds to the voltage list­ed on the data plate. If not, contact a qualified service agency to examine the problem. Do not run the dishmachine if the volt­age is too high or too low. Shut off the service breaker and mark it as being for the dishmachine. Advise all proper personnel of any problems and of the location of the service breaker. Replace the control box cover and tighten down the screws.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS (CONTINUED)
10
Incoming Power Connection
Power Block Ground Lug
Page 19
PREPARATION: Before proceeding with the start-up of the unit, verify the following:
1. The pan strainer and pump suction strainer are in place and are clean.
2. The overflow tube and o-ring are installed.
3. That the wash and rinse arms are screwed securely into place and that their endcaps are tight. The wash and rinse arms should rotate freely.
POWER UP: To energize the unit, turn on the power at the service breaker. The voltage should have been previously verified as being correct. If not, the voltage will have to be verified.
FILLING THE WASH TUB: Ensure that the delime switch is in the NORMAL position, and place the power switch into the ON position. The Tempstar should fill automatically and shut off when the appropriate level is reached (just below the pan strain­er). Verify that the drain stopper is preventing the wash tub water from leaking excessively. There may be some slight leakage from the drain hole. Verify that there are no other leaks on the unit before proceeding any further. The wash tub must be com­pletely filled before operating the wash pump to prevent damage to the component. Once the wash tub is filled, the unit is ready for operation.
WARE PREPARATION: Proper preparation of ware will help ensure good results and less re-washes. If not done properly, ware may not come out clean and the efficiency of the dishmachine will be reduced. It is important to remember that a dishmachine is not a garbage disposal and that simply throwing unscraped dishes into the machine simply defeats the purpose altogether of washing the ware. Scraps should be removed from ware prior to being loaded into a rack. Pre-rinsing and pre-soaking are good ideas, especially for silverware and casserole dishes. Place cups and glasses upside down in racks so that they do not hold water during the cycle. The dishmachine is meant not only to clean, but to sanitize as well, to destroy all of the bacteria that could be harmful to human beings. In order to do this, ware must be properly prepared prior to being placed in the machine.
DAILY MACHINE PREPARATION: Refer to the section entitled “PREPARATION” at the top of this page and follow the instruc­tions there. Afterwards, check that all of the chemical levels are correct and/or that there is plenty of detergent available for the expected workload.
WARM-UP CYCLES: For a typical daily start-up, it may be necessary to run the machine through 3 cycles to ensure that all of the cold water is out of the system and to verify that the unit is operating correctly. To cycle the machine, ensure that the power is on and that the tub has filled to the correct level. Lift the doors and the cycle light will illuminate. When the light goes out, close the doors, the unit will start, run through the cycle, and shut off automatically. Repeat this two more times. The unit should now be ready to proceed with the washing of ware.
WASHING A RACK OF WARE: To wash a rack, open the doors completely (being careful for hot water that may drip from the doors) and slide the rack into the unit.
Close the doors and the unit will start automatically. Once the cycle is completed, open the door (again watching for the drip­ping hot water) and remove the rack of clean ware. Replace with a rack of soiled ware and close the doors. The process will then repeat itself.
OPERATIONAL INSPECTION: Based upon usage, the pan strainer may become clogged with soil and debris as the workday progresses. Operators should regularly inspect the pan strainer to ensure it has not become clogged. If the strainer does, it will reduce the washing capability of the machine. Instruct operators to clean out the pan strainer at regular intervals or as required by work load.
SHUTDOWN AND CLEANING: At the end of the workday, close the doors. When the unit completes the cycle, turn the power switch to the OFF position and open the doors. Remove and clean the pan strainer. Remove the drain stopper from the tub and allow the tub to drain (NOTE: the wash tank water will be hot so caution is advised). Once the wash tub is drained, remove the pump suction strainer. Remove soil and debris from the strainer and set to the side. Unscrew the wash and rinse arms from their manifolds. Remove the endcaps and flush the arms with water. Use a brush to clean out the inside of the arms. If the noz­zles appear to be clogged, use a toothpick to remove the obstruction. Wipe the inside of the unit out, removing all soil and scraps. Reassembly the wash and rinse arms and replace them in the unit. The arms only need to be hand tight, do not use tools to tighten them down. Reinstall the drain stopper and strainers and close the doors.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
OPERATION INSTRUCTIONS
11
Page 20
Detergent usage and water hardness are two factors that contribute greatly to how efficiently your dishmachine will operate. Using detergent in the proper amount can become, in time, a source of substantial savings. A qualified water treatment spe­cialist can tell you what is needed for maximum efficiency from your detergent, but you should still know some basics so you’ll understand what they are talking about.
First, you must understand that hard water greatly effects the performance of the dishmachine. Water hardness is the amount of dissolved calcium and magnesium in the water supply. The more dissolved solids in the water, the greater the water hard­ness. Hard water works against detergent, thereby causing the amount of detergent required for washing to increase. As you use more detergent, your costs for operating the dishmachine will increase and the results will decrease. The solids in hard water also may build-up as a scale on wash and rinse heaters, decreasing their ability to heat water. Water temperature is important in removing soil and sanitizing dishes. If the water cannot get hot enough, your results may not be satisfactory. This is why Jackson recommends that if you have installed the machine in an area with hard water, that you also install some type of water treatment equipment to help remove the dissolved solids from the water before it gets to the dishmachine.
Second, hard water may have you adding drying agents to your operating cycle to prevent spotting, when the real problem is deposited solids on your ware. As the water evaporates off of the ware, the solids will be left behind to form the spotting and no amount of drying agent will prevent this. Again, using treated water will undoubtedly reduce the occurrences of this prob­lem.
Third, treated water may not be suitable for use in other areas of your operation. For instance, coffee made with soft water may have an acid or bitter flavor. It may only be feasible to install a small treatment unit for the water going into the dishmachine itself. Discuss this option with your qualified water treatment specialist.
Even after the water hardness problems have been solved, there still must be proper training of dishmachine operators in how much detergent is to be used per cycle. Talk with your water treatment specialist and detergent vendor and come up with a complete training program for operators. Using too much detergent has as detrimental effects as using too little. The proper amount of detergent must be used for job. It is important to remember that certain menu items may require extra detergent by their nature and personnel need to be made aware of this. Experience in using the dishmachine under a variety of conditions, along with good training in the operation of the machine, can go a long way in ensuring your dishmachine operates as effi­ciently as possible.
Certain dishmachine models require that chemicals be provided for proper operation and sanitization. Some models even require the installation of third-party chemical feeders to introduce those chemicals to the machine. Jackson does not recom­mend or endorse any brand name of chemicals or chemical dispensing equipment. Contact your local chemical distributor for questions concerning these subjects.
Some dishmachines come equipped with integral solid detergent dispensers. These dispensers are designed to accommodate detergents in a certain sized container. If you have such a unit, remember to explain this to your chemical distributor upon first contacting them.
As explained before, water temperature is an important factor in ensuring that your dishmachine functions properly. The data plate located on each unit details what the minimum temperatures must be for either the incoming water supply, the wash tank and the rinse tank, depending on what model of dishmachine you have installed. These temperatures may also be followed by temperatures that Jackson recommends to ensure the highest performance from you dishmachine. However, if the minimum requirements are not met, the chances are your dishes will not be clean or sanitized. Remember, a dish can look clean, but it may not be sanitized. Instruct your dishmachine operators to observe the required temperatures and to report when they fall below the minimum allowed. A loss of temperature can indicate a much larger problem such as a failed heater or it could also indicate that the hot water heater for your operation is not up to capacity and a larger one may need to be installed.
There are several factors to consider when installing your dishmachine to ensure that you get the best possible results from it and that it operates at peak efficiency for many years. Discuss your concerns with your local chemical distributor and water treatment specialist before there is a problem.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
DETERGENT CONTROL
12
Page 21
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
13
FALSE PANEL INSTALLATION
1. Remove the rack assembly from the unit.
2. False panel will mount inside the dishmachine.
3. Position panel in unit on side to be closed.
4. Hold panel against side of dishmachine and push up.
5. Panel will clip in at the top, inside unit.
6. Holes in false panel will line up with rack assembly holes.
7. Re-install screws for rack assembly which will secure false panel to unit.
8. Re-assemble the rack track in an “L” shape for a corner oper­ation.
Bottom of side panel.
Insert this side first.
False panel positioned in unit.
Rack rail removed & reposi­tioned for a corner operation.
False Panel
Page 22
14
SECTION 3:
PREVENTATIVE MAINTENANCE
Page 23
The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However, this does not mean that some items will not wear out in time. Jackson highly recommends that any maintenance and repairs not specifically discussed in this manual should be performed by QUALIFIED SERVICE PERSONNEL ONLY. Performing main­tenance on your dishmachine may void your warranty if it is still in effect, so if you have a question or concern, do not hesitate to contact one of the QUALIFIED SERVICE AGENCIES listed in the back of this manual.
There are many things that operators can do to prevent catastrophic damage to the dishmachine. One of the major causes of component failure has to do with prescrapping procedures. A dishmachine is not a garbage disposal; any large pieces of mate­rial that are put into the machine shall remain in the machine until they are either broken up (after spreading out on your ware!) or physically removed. Strainers are installed to help catch debris, but they do no good if they are clogged. Have operators reg­ularly inspect the pan strainers to ensure (1) that they are free of soil and debris and (2) they are laying flat in the tub.
When cleaning out strainers, do NOT beat them on waste cans. The strainers are made of metal and can be forgiving; but once severe damage is done, it is next to impossible for the strainer to work in the way it was designed to. Wipe out strainers with a rag and rinse under a faucet if necessary. For stubborn debris, a toothpick should be able to dislodge any obstructions from the perforations. Always ensure that strainers are placed back in the machine before operation and that they lay flat in the tub.
You may wish to learn more about how your water hardness will effect the performance of your machine. Hard water makes dishmachines work harder and decreases efficiency.
Again, it is important to remind operators that trying to perform corrective maintenance on the dishmachine could lead to larg­er problems or even cause harm to the operator. If a problem is discovered; secure the dishmachine using proper shut down procedures as listed in this manual and contact a QUALIFIED SERVICE AGENCY.
Some problems, however, may having nothing to do with the machine itself and no amount of preventative maintenance is going to help. A common problem has to do with temperatures being too low. Verify that the water temperatures coming to your dishmachine match the requirements listed on the machine data plate. There can be a variety of reasons why your water tem­perature could be too low and you should discuss it with a QUALIFIED SERVICE AGENCY to determine what can be done.
By following the operating and cleaning instructions in this manual, you should get the most efficient results from your machine. As a reminder, here are some steps to take to ensure that you are using the dishmachine the way it was designed to work:
1. Ensure that the water temperatures match those listed on the machine data plate.
2. Ensure that all strainers are in place before operating the machine.
3. Ensure that all wash and/or rinse arms are secure in the machine before operating.
4. Ensure that drains are closed/sealed before operating.
5. Remove as much soil from dishes by hand as possible before loading into racks.
6. Do not overfill racks.
7. Ensure that glasses are placed upside down in the rack.
8. Ensure that all chemicals being injected to machine have been verified as being at the correct concentrations.
9. Clean out the machine at the end of every workday as per the instructions in the manual.
10. Always contact a QUALIFIED SERVICE AGENCY whenever a serious problem arises.
11. Follow all safety procedures, whether listed in this manual or put forth by local, state or national codes/regulations.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 3: PREVENTATIVE MAINTENANCE
PREVENTATIVE MAINTENANCE
15
Page 24
16
SECTION 4:
TROUBLESHOOTING SECTION
Page 25
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 4: TROUBLESHOOTING
COMMON PROBLEMS
17
WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service technician. Many of the tests require that the unit have power to it and live electrical components be exposed. USE EXTREME CAUTION WHEN TESTING THE MACHINE.
Problem: Dishmachine will not fill after the door is close. Power “ON” light is illuminated.
1. Faulty rinse solenoid valve. Repair or replace valve as required.
2. Faulty door switch. Verify the wiring of the switch; if correct, replace the switch.
3. Fouled/faulty high level probe. Clean probe if fouled. If clean, and still not working, replace.
Problem: Dishmachine will not fill after the door is closed. Power “ON” light is not illuminated.
1. Service breaker tripped. Reset. If the breaker trips again, contact an electrician to verify the amp draw of the machine.
2. Machine not connected to power source. Verify that the machine has been properly connected to the power source.
3. Faulty power source. Verify the wiring of the switch; if correct, replace switch.
Problem: Dishmachine will not run after the door is closed. Power “ON” light is illuminated and the unit is filling.
1. Timer motor is faulty. Verify that the timer is rotating. If not, check to see that the motor is receiving power. If so, replace the motor and/or timer assembly.
2. Wash motor faulty/damaged. Verify that the wash motor is getting power. If so, replace the motor.
3. Wash motor contactor faulty. Check for continuity; if contacts are open, replace the contactor.
Problem: Dishmachine runs continuously in the wash cycle.
1. Machine is in Delime mode. Flip NORMAL/DELIME switch to NORMAL mode.
2. Timer motor is faulty. Verify that the timer is rotating. If not, check to see that the motor is receiving power. If so, replace the motor and/or timer assembly.
3. Cam timer jammed by obstruction. Remove obstruction.
Problem: Wash or rinse heater does not work.
1. Faulty heater element. Check element for continuity; if open, replace the heater.
2. Faulty heater contactor. Replace the contactor.
3. Misadjusted/faulty thermostat(s). Verify operation and setting of thermostats, replace if necessary.
Problem: Dishmachine fill slowly and/or the rinse is weak.
1. Clogged or obstructed rinse arms. Remove and clean the rinse arms.
2. Low incoming water pressure. Adjust the water pressure regulator to ensure that there is 20±5 PSI flow.
3. Y-strainer is clogged. Clean out the Y-strainer.
Problem: Rinse water not reaching required temperature.
1. Faulty rinse heater. Check element for continuity; if open, replace heater.
2. Misadjusted/faulty thermostat(s). Verify operation and setting of thermostats, replace if necessary.
3. Rinse thermometer is defective. Replace thermometer.
Problem: Wash water is not reaching required temperature.
1. Faulty wash heater. Check element for continuity; if open, relace the heater.
2. Misadjusted/faulty thermostat(s). Verify operation and setting of thermostats, replace if necessary.
3. Wash thermometer is defective. Replace thermometer.
Page 26
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 4: TROUBLESHOOTING
COMMON PROBLEMS
18
WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service technician. Many of the tests require that the unit have power to it and live electrical components be exposed. USE EXTREME CAUTION WHEN TESTING THE MACHINE.
Problem: Doors will not close completely.
1. Improper spring tension. Adjust spring tension as required by loosening (not removing) spring bolt nuts and adjusting the tension. Tighten nuts back when done.
2. Obstruction in door channel. Remove the obstruction.
3. Doors are not square with frame. Adjust the frame to accommodate the doors.
Problem: Water leaks at the wash pump.
1. Wash pump seal defective. Replace the seal.
2. Petcock or pump drain (if equipped) not shut/tight. Close or tighten.
3. Loose hoses (hose clamps) on the wash pump. Tighten the hose clamps.
Problem: Will not rinse during autocycle.
1. Defective rinse solenoid. Repair or replace the rinse solenoid as required.
2. Faulty fill microswitch. Replace microswitch.
3. No water to the machine. Verify that there is water a 20 ±5 PSI connected to the machine.
Problem: Dishes are not coming clean.
1. Machine temperatures are not up to the minimum requirements. Verify that incoming water, rinse water, and wash water match the required temperatures as listed on the machine data plate.
2. No detergent/too much detergent. Adjust detergent concentration as required for the amount of water held by the machine.
3. Solid dispenser canister is empty. Replace the canister.
Page 27
19
SECTION 5:
PARTS SECTION
Page 28
10
29
30
6
11
39
40
42
1
35
34
36
6
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TOP MOUNTED CONTROL BOX ASSEMBLY WITH UNIVERSAL TIMER
20
14 1518 33
Page 29
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TOP MOUNTED CONTROL BOX ASSEMBLY WITH UNIVERSAL TIMER (CONTINUED)
21
ITEM QTY DESCRIPTION Mfg. No.
1 1 Control Box Weldment 05700-003-30-14 2 1 Timer Bracket 05700-003-02-08 5 2 Locknut, 6-32 S/S Hex w/Nylon Insert 05310-373-03-00 6 2 Contactor, 4 Pole 05945-109-01-69 7 1 Terminal Block 05940-011-48-27 8 19 Locknut, 10-24 S/S Hex w/Nylon Insert 05310-373-01-00 9 1 Contactor, Wash Motor 208-230, 30Amp 05945-002-74-20 10 1 Switch, 8 Button 05930-001-99-51 11 6 Holder, Keystone 05940-002-21-87 12 1 Timer, Universal 05945-003-07-48 13 1 Relay, All Voltages 05945-111-47-51
1 Relay, (415V, 3PH, 5 Wire Only) 05945-111-89-75 14 1 Light, Green 05945-111-44-43 15 1 Light, Red 05945-111-44-45 16 1 Temperature Gauge, Wash 96" Lead 06685-111-68-48 17 1 Temperature Gauge, Rinse 48" Lead 06685-111-68-49 18 1 Light, Yellow 05945-111-44-44 19 1 Decal Wash 150F. Deg. Min. 09905-002-97-61 20 1 Decal Wash 180F. Deg. Min. 09905-002-97-62 21 1 Ground Lug 05940-200-76-00 22 1 Bracket, Liquid Level Control Board 05700-002-13-22 23 1 Liquid Level Control Board 06680-200-08-21 24 6 Tricnut, 6-32 N/A 25 3 Screw, 6-32 x 5/8” 05305-011-39-85 26 1 Spacer, Switch Panel Temp 05700-002-50-02 27 3 Plug, 1/2” 05975-011-47-81 28 2 Grommet, 7/8” Split 05975-200-40-00 29 1 Bushing, Snap 05975-210-05-00 30 1 Clamp, Hose, .25-.312 05975-002-61-43 31 1 Decal, Warning-Disconnect Power 09905-100-75-93 32 Cover, Top Mount Control Box 05700-002-23-03 33 1 Decal, Control Box 09905-003-21-90 34 4 Lockwasher, Int. Tooth #10 05311-273-03-00 35 4 Screw, 10-32 x 3/8” Phillips Truss Head 05305-173-12-00 36 1 Decal, Copper Conductors 09905-011-47-35 37 1 Decal, Ground 09905-011-86-86 38 1 Decal, L1, L2 09905-002-78-67 39 1 Bracket, Fuse Strip 05700-002-42-03 40 1 Fuse Holder, 6 Pole 05920-002-42-13 41 2 Screw, 6-32 x 3/8” W/ Ext. Tooth Washer 05305-002-25-91 42 1 Decal, Dispenser Connection 09905-003-34-09
Page 30
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TOP MOUNTED CONTROL BOX ASSEMBLY (MECHANICAL TIMER)
22
21 20
1
2
3
4
5
6
7
98 10 11 12 13 14
19
18
17
16
15
Page 31
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TOP MOUNTED CONTROL BOX ASSEMBLY (MECHANICAL TIMER) (CONTINUED)
23
ITEM QTY DESCRIPTION Mfg. No.
1 1 Control Box Weldment 05700-002-29-76 2 1 Ground Lug 05940-200-76-00 3 1 Terminal Block 05940-011-48-27 3 1 Terminal Block (415V, 3PH, 5 Wire Only) 05940-002-42-24 4 1 Contactor, Wash Motor 208-230 05945-002-74-20 4 1 Contactor, Wash Motor (380, 415, 440, 460 Volt Units) 05945-002-65-00 4 1 Overload, 1.7-2.6 (380, 415, 440, 460 Volt Units) 05945-002-65-02 5 1 Relay, All Voltages 05945-111-47-51 5 1 Relay, (415V, 3PH, 5 Wire Only) 05945-111-89-75 6 1 Counter 05990-111-47-42 7 1 Plate, Counter Mounting 05700-002-37-71 8 1 Decal, Control Box 09905-002-31-85 9 1 Light, Yellow 05945-111-44-44 10 1 Light, Green 05945-111-44-43 11 1 Light, Red 05945-111-44-45 12 1 Temperature Gauge, Wash 96" Lead 06685-111-68-48 13 1 Temperature Gauge, Rinse 48" Lead 06685-111-68-49 14 1 Switch, Power 05930-002-29-13 15 1 Timer, 60 Hz All Voltages 05945-303-31-00 15 1 Timer, 50 Hz All Voltages 05945-306-14-00 16 1 Liquid Level Control Board 06680-200-08-21 17 1 Bracket, Liquid Level Control Board 05700-002-13-22 18 2 Heater Contactor (All Voltages) (Not used on Tempstar S) 05945-109-01-69 18 2 Heater Contactor (415V, 3PH, 5 Wire Only) 05945-002-64-96 19 1 Magnetic Reed Switch 05930-011-47-50 20 1 Normal Delime Switch 05930-301-21-18 21 1 Fuse Holder 05920-401-03-14
Other components not shown:
Cover, Top Mount Control Box 05700-002-23-03 Decal, Warning-Disconnect Power 09905-100-75-93 Screw, 10-32 x 3/8” Phillips Truss Head 05305-173-12-00 Leg, Control Box 05700-002-33-05 Screw, 1/4”-20 x 2 3/4” Hex Head Cap 05305-274-13-00 Washer, 1/4”-20 ID S/S 05311-174-01-00 Locknut, 1/4”-20 S/S Hex w/Nylon Insert 05310-374-01-00 Connector, 1/2”, 90° Plastic 05975-011-45-14 Connector, 3/4”, 45° Plastic 05975-011-47-74 Connector, 1/2”, 45° Plastic 05975-011-45-23 Connector, 1/2”, 90° Metal 05975-111-01-00 Grommet, 1/2” OD x 3/8” ID 05325-011-46-73 Grommet, 7/8” Split 05975-200-40-00 Plug, 1/2” 05975-011-47-81 Decal, Delime/Normal 09905-011-34-96 Decal, L1, L2, L3 09905-101-12-66 Decal, Copper Conductors 09905-011-47-35 Decal, Ground 09905-011-86-86
Associated Hardware:
Locknut, 6-32 S/S Hex w/Nylon Insert 05310-373-03-00 Locknut, 10-24 S/S Hex w/Nylon Insert 05310-373-01-00 Screw, 6-32 x 5/8” 05305-011-39-85 Screw, 6-32 x 3/8” Phillips Round Head 05305-171-02-00
Page 32
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
SIDE MOUNTED CONTROL BOX ASSEMBLY
24
1
2, 21
3
CONTROL BOX FRONT COVER
4
5
6
7, 8
INNER CONTROL BOX LAYOUT
9, 22
11, 22
10, 22
12, 22
13, 14
12, 22
15, 16
17
18, 23, 24
19
CONTROL BOX BOTTOM LAYOUT
21, 22
20
The mounting screws for the control box front cover (10-32 X 1/2” Slotted Truss Head Screws) may be ordered using Mfg. No.: 05305-011-39-85.
Bracket, Side Mount Electrical Box
05700-041-65-68
Cover, Dielectric Control Panel 05700-021-50-89
Page 33
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
SIDE MOUNTED CONTROL BOX ASSEMBLY (CONTINUED)
25
ITEM QTY DESCRIPTION Mfg. No.
1 1 Power Switch 05930-301-21-18 2 1 Cycle Counter 05990-111-47-42 3 1 Normal/Delime Switch 05930-301-46-00 4 1 Power Light 05945-504-06-18 5 1 High Limit Light 05945-504-07-18 6 1 Cycle Light 05945-504-08-18 7 1 Decal, Control Box Cover 09905-021-64-41 8 1 Control Box Cover 05700-031-91-45 9 1 Relay, Top Mount, Control 05945-111-47-51 10 1 Fuse Holder 05920-401-03-14 11 1 Timer, 60 Hz 05945-303-31-00 11 1 Timer, 50 Hz 05945-306-14-00 12 2 Contactor, 220V, 4 Pole (1 for Tempstar NB models) 05945-109-01-69 13 1 Liquid Level Control Board 06680-200-08-21 14 2 Screw, 6-32 x 5/8" Long 05305-011-39-85 15 1 Wash Motor Contactor 05945-109-03-69 15 1 Wash Motor Contactor 05945-002-14-78 16 3 Screw, 10-32 x 3/8" Panhead 05305-173-26-00 17 1 Overload (460 Volt Unit) 05945-002-65-01 18 1 3 Pole Terminal Block 05940-011-48-27 19 1 Control Box Weldment 05700-041-47-55 20 1 Circuit Breaker, 2 AMP (460 Volt Unit) 05925-111-64-18 21 1 Transformer, (460-440 Volt Unit) 05950-111-65-93 21 1 Transformer, (380 Volt Unit) 05950-111-64-17 22 9 Screw, 6-32 x 3/8" Long 05305-171-02-00 23 3 Locknut, 10-24 w/Nylon Insert 05310-373-01-00 24 1 Ground Lug 05940-200-76-00
Other components not shown:
Connector, 1/2”, 90° Plastic 05975-011-45-14 Connector, 3/4”, 45° Plastic 05975-011-47-74 Connector, 1/2”, 45° Plastic 05975-011-45-23 Connector, 1/2”, 90° Metal 05975-111-01-00 Grommet, 1/2” OD x 3/8” ID 05325-011-46-73 Grommet, 7/8” Split 05975-200-40-00 Plug 05975-011-47-81 Decal, Delime/Normal 09905-011-34-96 Decal, L1, L2, L3 09905-101-12-66 Decal, Copper Conductors 09905-011-47-35 Decal, Ground 09905-011-86-86
Page 34
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
SDS SIDE MOUNTED CONTROL BOX ASSEMBLY
26
Cover, Dielectric Control Panel 05700-021-50-89
Bracket, Side Mount Electrical Box
05700-041-65-68
6
14
15
19
20
23
22
11
12
13
10
16
17
18
9
8
7
1
2
3
4
5
25
21
24
26
27
Page 35
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
SDS SIDE MOUNTED CONTROL BOX ASSEMBLY (CONTINUED)
27
ITEM QTY DESCRIPTION Mfg. No.
1 1 Control Box Cover Weldment 05700-021-60-43 2 1 Decal, Control Box Cover 09905-021-50-13 3 1 Light, Amber 05945-504-06-18 4 1 Light, Green 05945-504-08-18 5 1 Light, Red 05945-504-07-18 6 1 Manual Wash Switch 05930-301-46-00 7 2 Screw, 4-40 x 1/4" Phillips Panhead 05305-011-36-92 8 1 Cycle Counter 05990-111-47-42 9 1 Wash Switch 05930-301-21-18 10 4 Screw, 10-32 x 3/8" Phillips Panhead 05305-173-04-00 11 1 Cover, Electrical Box Panel 05700-011-49-23 12 1 Frame, Electrical Box Cover Panel 05700-011-49-22 13 1 Board, PC Rinse 06680-111-50-55 14 1 Board, PC Detergent 06680-111-50-54 15 8 Screw, 6-32 x 3/8" Long 05305-171-02-00 16 1 Bracket, PC Board 05700-011-49-24 17 4 Lockwasher, #10 Internal Tooth 05311-011-59-51 18 4 Locknut, 10-24 w/Nylon Insert 05310-373-01-00 19 1 Control Box Weldment 05700-041-47-55 20 2 Relay, Top Mount, Control 05945-111-47-51 21 2 Contactor, 220V, 4 Pole 05945-109-01-69 22 1 Timer, 60 HZ 05945-303-31-00 23 1 Liquid Level Control Board 06680-200-08-21 24 1 Contactor, 220V, 2 Pole 05945-109-03-69 24 1 Wash Motor Contactor (460 Volt Unit) 05945-002-14-78 24 1 Overload (460 Volt Unit) 05945-002-33-42 25 1 Transformer 05950-400-01-35 25 1 Transformer (380 Volt Unit) 05950-111-64-17 25 1 Transformer (460 Volt Unit) 05950-111-65-93 26 1 Ground Lug 05940-200-76-00 27 1 3 Pole Terminal Block 05940-011-48-27 28* 1 Fuse Holder (460 Volt Unit) 05940-401-03-14 29* 1 Circuit Breaker, 2 AMP (460 Volt Unit) 05925-111-64-18
Other components not shown:
Connector, 1/2”, 90° Plastic 05975-011-45-14 Connector, 3/4”, 45° Plastic 05975-011-47-74 Connector, 1/2”, 45° Plastic 05975-011-45-23 Connector, 1/2”, 90° Metal 05975-111-01-00 Grommet, 1/2” OD x 3/8” ID 05325-011-46-73 Grommet, 7/8” Split 05975-200-40-00 Plug, 1/2” 05975-011-47-81 Decal, Delime/Normal 09905-011-34-96 Decal, L1, L2, L3 09905-101-12-66 Decal, Copper Conductors 09905-011-47-35 Decal, Ground 09905-011-86-86
Page 36
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
HOOD ASSEMBLY
28
1
2
3, 5
4
6
7
8 9 10
Switch Box Weldment
05700-002-14-34
SDS Switch Box Weldment
05700-002-30-98
Magnetic Reed Switch
05930-003-05-84
ITEM QTY DESCRIPTION Mfg. No.
1 1 Hood Weldment (Tempstar/Tempstar LT/Tempstar NB) 05700-041-94-39 1 1 Hood Weldment (Tempstar SDS) 05700-041-47-87 2 1 Left Front Hood Support 05700-021-33-18 3 1 Right Front Hood Support 05700-021-33-17 4 1 Double Door Guide, Front Left 05700-021-33-20 5 1 Double Door Guide, Front Right 05700-021-33-19 6 1 Guide, Right Rear 05700-021-84-70 7 1 Guide, Left Rear 05700-021-84-71 8 28 Screw, 1/4"-20 x 1/2" Long 05305-274-02-00 9 28 Locknut, 1/4"-20 with Nylon Insert 05310-374-01-00 10 28 Washer, 1/4"-20 ID, S/S, Flat 05311-174-01-00
Page 37
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
HOOD ASSEMBLY (BOLTED SINGLE SUPPORT DESIGN)
29
ITEM QTY DESCRIPTION Mfg. No.
1 1 Hood Weldment (Tempstar/Tempstar LT/Tempstar NB) 05700-002-29-79 1 1 Hood Weldment (Tempstar SDS) 05700-002-36-91 2 2 Hood Support 05700-002-78-99 3 6 Bolt, 1/4”-20 x 1/2” Long 05305-274-21-00 4 6 Washer, Flat, SS, 1/4”-20 ID 05311-174-01-00 5 6 Locknut, 1/4”-20 with Nylon Insert (Not Shown) 05310-374-01-00 6 4 Block Spacer 05700-002-81-02
1
2
3
4
Page 38
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
CANTILEVER ARM/DOOR ASSEMBLIES
30
3
5
2
1
6
9
15, 16
17, 18
19, 11, 12
2019, 11, 21
22
23, 18
7
8
4
24, 18
14
1310, 11, 12
3d
3b
3f
3c
3a
3e
Page 39
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
CANTILEVER ARM/DOOR ASSEMBLIES (CONTINUED)
31
ITEM QTY DESCRIPTION Mfg. No.
1 1 Cantilever Arm 05700-031-50-67 2 2 Spring Pin, 1/4" x 1 1/8" 05315-407-06-00 3 2 Yoke Assembly 05700-000-75-77 3a 1 Cotter Pin 05315-207-01-00 3b 1 Yoke 05700-000-75-78 3c 1 Clevis Pin, 5/16” x 1 3/8” 05315-700-01-00 3d 2 Nylon Washer 05311-369-03-00 3e 1 Bushing 03120-100-03-00 3f 2 Locknut, 3/8”-16 S/S Hex Center 05310-256-04-00 4 2 Rod, Spring 05700-002-29-38 5 2 Spring 005340-109-02­00 6 2 Bolt, Cantilever Hanger Eye 3/8"-16 05306-956-05-00 7 2 Washer, 3/8" ID x 7/8" OD S/S 05311-176-02-00 8 4 Nut, 3/8"-16 S/S Hex 05310-276-01-00 9 2 Connector, Cantilever Arm 05700-011-90-99 10 2 Screw, 1/4"-20 x 1 1/2" Long S/S 05305-274-23-00 11 4 Washer, 1/4" S/S 05311-174-01-00 12 4 Locknut, 1/4"-20 S/S Hex with Nylon Insert Low Profile 05310-374-02-00 13 2 Sleeve, Cantilever Arm 05700-000-85-69 14 2 Plug, Cantilever Arm 05340-011-35-00 15 1 Magnet, Reed Switch 05930-111-51-68 16 2 Locknut, 8-32 S/S Hex with Nylon Insert 05310-272-02-00 17 1 Door, Right Side (Complete Assembly) 05700-002-30-88 17A 1 Right Door Weldment with Studs 05700-002-29-85 18 6 Door, Guides 05700-111-33-59 19 2 Screw, 1/4"-20 x 1/2" Long S/S 05305-274-02-00 20 2 Spacer, PB Bolt 05700-000-29-40 21 4 Locknut, 1/4"-20 S/S Hex with Nylon Insert 05310-374-01-00 22 2 Door Connector Bracket 05700-021-33-39 23 1 Door, Front (Complete Assembly) 05700-002-30-89 23A 1 Door Only, Front 05700-002-29-83 24 1 Door, Left Side (Complete Assembly) 05700-002-30-87 24A 1 Door Only, Left Side 05700-002-29-86 25 4 Door Connecting Plate 05700-002-20-78 26* 2 Bracket, Cantilever Arm Support 05700-031-88-00 27* 6 Wear Button, 1/2" Dia. UHMW 05700-011-88-01
Bracket, Cantilever Arm Support
09515-003-15-64
Wear Button, 1/2" Dia. UHMW
05700-011-88-01
Page 40
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TUB ASSEMBLY
32
12
10, 11
2 3
4
7 8
13
14, 11
15
5 9
3
16
6
32
31, 30
22 2321
24
25 27, 28
37
34
36
35
26
33
1
29
17
16
18
19
20
Pump Support Bracket Complete Assembly
05700-002-00-46
Nut, 1/4”-20 Serrated Nut
05310-011-66-49
Bracket, Motor Support Weldment
05700-002-68-31
Pump Support Adjustable Bracket
05700-002-20-41
* Represents an item not shown.
Page 41
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TUB ASSEMBLY (CONTINUED)
33
ITEM QTY DESCRIPTION Mfg. No.
1 1 Tub Weldment 05700-002-12-59 2 1 Rack Assembly 05700-002-01-00 3 2 Bulk Head Plug 04730-609-05-00 4 1 See Page Entitled “Wash Motors” N/A 5 1 Gasket 05700-111-35-03 6 1 O-ring 05330-400-05-00 7 4 Bolt, Hex 3/8”-16 x 1 1/4" Long 05305-276-10-00 8 1 Lower Wash Manifold Weldment 05700-031-46-00 9 1 Suction Strain Weldment 05700-001-22-23 10 1 Suction Strain Bracket 05700-001-22-24 11 8 Locknut, 1/4"-20 with Nylon Insert 05310-374-02-00 12 1 Strainer Weldment 05700-021-50-07 13 1 Wash Overflow Weldment 05700-001-25-69 * 1 Support, Ball Stop Lift 05700-002-91-55 * 1 Ball Stop Lift 05700-002-91-54 * 1 Shim, Overflow Support 05700-002-96-48 14 1 Overflow Support Bracket 05700-001-27-55 15 1 O-Ring 05330-400-05-00 16 2 Clamp, Hose 1 5/16” to 2 1/4” 04730-719-01-37 17 1 Discharge Hose 05700-011-88-24 18 1 Nipple 05700-021-34-84 19 1 Pump Support Bracket Assembly 05700-002-00-46 20 1 Clamp, Hose 5 5/8" to 6" 04730-011-34-90 21 1 Connector, 1/2” 90° 05975-111-01-00 22 4 Nut, 3/8"-16 S/S Hex 05310-276-01-00 23 4 Lockwasher 3/8” 05311-276-01-00 24 1 See Page Entitled “Wash Heaters/Rinse Heaters” N/A
See page 27 to order phase conversion kits for the heater. 25 1 Probe, High Water 06680-200-02-68 26 5 Locknut, 6-32 with Nylon Insert 05310-373-03-00 27 4 Lockwasher, 5/16", S/S, Split 05311-275-01-00 28 4 Nut, Hex, 5/16"-18, S/S 05310-275-01-00 29 4 Locknut, 10-24 with Nylon Insert 05310-373-01-00 30 1 Cover, Wash Heater 05700-031-47-57 31 1 Decal, Warning-Disconnect Power 09905-100-75-93 32 1 Decal, High Limit 09905-011-84-32 33 1 Thermostat Bracket 05700-011-81-64 34 1 Wash Heater Gasket 05330-011-47-79 35 1 Thermostat, Regulating 05930-510-02-79
1 Kit, Wash Thermostat Replacement
(Includes: thermostat, brass fitting, 2 jumper wires & instructions) 06401-003-18-22 36 1 Thermostat, High Limit 05930-011-49-43 37 1 Fitting, 1/4" Imperial Brass 05310-924-02-05
Items for side-mounted control box not shown:
* 1 Gauge Bracket (Side Mount Control Box Only) 05700-011-48-08 * 1 Thermometer, Wash (Side Mount Control Box Only) 06685-111-40-38 * 1 Thermometer, Rinse (Side Mount Control Box Only) 06685-111-40-39
Page 42
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
STEAM TUB ASSEMBLY
34
12
10, 11
2 3
4
7 8
13
14, 11, 15
5 9
3
16
6
22, 2321
24
25 27, 28
24
26
1
29
17
16
18
19
20
Pump Support Bracket Complete Assembly
05700-002-00-46
Nut, 1/4”-20 Serrated Nut
05310-011-66-49
Bracket, Motor Support Weldment
05700-002-68-31
Pump Support Adjustable Bracket
05700-002-20-41
* Represents an item not shown.
Page 43
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
STEAM TUB ASSEMBLY (CONTINUED)
35
ITEM QTY DESCRIPTION Mfg. No.
1 1 Tub Weldment 05700-002-09-26 2 1 Rack Assembly 05700-002-01-00 3 2 Bulk Head Plug 04730-609-05-00 4 1 See page entitled “Wash Motors” N/A 5 1 Gasket 05700-111-35-03 6 1 O-ring 05330-400-05-00 7 4 Bolt, Hex 3/8”-16 x 1 1/4" Long 05305-276-10-00 8 1 Lower Wash Manifold Weldment 05700-031-46-00 9 1 Suction Strain Weldment 05700-001-22-23 10 1 Suction Strain Bracket 05700-001-22-24 11 8 Locknut, 1/4"-20 with Nylon Insert 05310-374-02-00 12 1 Strainer Weldment 05700-021-50-07 13 1 Wash Overflow Weldment 05700-001-25-69 * 1 Support, Ball Stop Lift 05700-002-91-55 * 1 Ball Stop Lift 05700-002-91-54 * 1 Shim, Overflow Support 05700-002-96-48 14 1 Overflow Support Bracket 05700-001-27-55 15 1 O-Ring 05330-400-05-00 16 2 Clamp, Hose 1 5/16” to 2 1/4” 04730-719-01-37 17 1 Discharge Hose 05700-011-88-24 18 1 Nipple 05700-021-34-84 19 1 Pump Support Bracket Assembly 05700-002-00-46 20 1 Clamp, Hose 5 5/8" to 6" 04730-011-34-90 21 1 Connector, 1/2” 90 Deg. 05975-111-01-00 22 4 Nut, 3/8"-16 S/S Hex 05310-276-01-00 23 4 Lockwasher 3/8” 05311-276-01-00 24 1 Fitting, 1/4" Imperial Brass 05310-924-02-05 25 1 Probe, High Water 06680-200-02-68 26 1 Thermostat, Regulating 05930-510-02-79
1 Kit, Wash Thermostat Replacement
(Includes: thermostat, brass fitting, 2 jumper wires & instructions) 06401-003-18-67 27 1 Cover, Wash Heater 05700-031-47-57 28 1 Decal, Warning-Disconnect Power 09905-100-75-93 29 2 Locknut, 10-24 with Nylon Insert 05310-373-01-00 30 3 Locknut, 6-32 with Nylon Insert 05310-373-03-00
Page 44
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
FRAME ASSEMBLY
36
Front Panel 05700-002-36-65
Bolt, 1/4”-20 x 1/2”
05305-274-02-00
Locknut, 1/4”-20 S/S Hex with Nylon Insert
05310-374-02-00
Bullet Foot
05340-108-01-03
Frame Weldment 05700-031-48-01
Flanged Bullet Foot 05340-002-34-86
Page 45
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
RINSE TANK ASSEMBLY
37
4
5
9
11
12
2, 3
1
6 10
7, 8
See page entitled
“WASH HEATERS/RINSE
HEATERS”.
ITEM QTY DESCRIPTION Mfg. No.
1 1 Booster Tank Weldment 05700-001-22-02 2 2 Locknut, 10-24 with Nylon Insert 05310-373-01-00 3 2 Washer, #10 S/S Flat 05311-173-01-00 4 1 Decal, Warning - Disconnect Power 09905-100-75-93 5 1 Booster Tank Cover Weldment 05700-001-29-30 6 6 Nut, Hex, 5/16"-18 05310-275-01-00 7 4 Locknut, 1/4"-20 with Nylon Insert 05310-374-01-00 8 4 Washer, 1/4" ID, S/S, Flat 05311-174-01-00 9 1 Thermostat, Rinse 05930-510-03-79
1 Kit, Rinse Thermostat Replacement
(Includes: thermostat, brass fitting, 2 jumper wires & instructions) 06401-011-66-55 10 6 Washer, 5/16” I.D. 05311-175-01-00 11 1 Gasket, Rinse Heater 05330-200-02-70 12 1 Fitting, 1/4" Imperial Brass 05310-924-02-05
See page 27 to order phase conversion kits for the heater.
Page 46
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
COIL ASSEMBLY
38
Stand C, Steam Coil Support
05700-002-08-52
Steam Coil Weldment
05700-021-41-38
Stand D, Steam Coil Support
05700-002-08-53
Stand B, Steam Coil Support
05700-002-08-51
Adapter, Steam Coil Nut
2 per assembly
05310-011-17-85
Washer, Steam Coil
2 per assembly
05700-001-17-87
Gasket, Steam Coil
4 per assembly
05700-001-17-86
Stand A, Steam Coil Support
05700-002-08-50
Complete Steam Coil Assembly
05700-002-08-62
Page 47
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
INCOMING STEAM PLUMBING ASSEMBLIES
39
Union, 3/4’’ NPT, Black Iron
04730-912-01-01
Elbow, 3/4” 90° Street 04730-011-87-37
Elbow, 3/4” 90° Street
04730-011-87-37
Steam Trap, 3/4” NPT F&T
06680-500-02-77
Nipple, Close, 3/4’’ NPT, Black Iron
04730-907-01-00
Bushing, Reducing, 3/4’’ to 1/2’’ 04730-911-02-34
Bushing, Reducing, 3/4’’ to 1/2’’ 04730-911-02-34
Elbow, 90° 3/4” NPT Black Iron
04730-011-87-37
Union, 3/4’’ NPT, Black Iron 2 per assembly 04730-912-01-01
3/4” NPT Black Iron Pipe
05700-002-20-83
Gate Valve, 3/4” NPT
04820-100-19-00
Bracket, Steam Plumbing Support
05700-002-20-83
Y-Strainer, 3/4” NPT Black Iron
04730-217-01-32
Solenoid Valve, Steam Plumbing, 220V
04820-002-01-32
Nipple, Close, 3/4’’ NPT, Black Iron
4 per Assembly
04730-907-01-00
To order this complete assembly, use part number: 05700-002-01-55
To order this complete assembly, use part number: 05700-002-01-60
Page 48
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
WASH MOTORS
40
The Tempstar models covered in this manual come supplied with various wash motor assemblies (a wash motor assembly includes the wash motor and the pump end), depending on the characteristics of the machine. To ensure that you order the correct wash motor assembly for the model you are servicing, please refer to the following table:
Model
Volts Hz Phase Wash Motor Assembly
Tempstar/Tempstar NB 208 50 1 06105-002-19-87 Tempstar/Tempstar NB 208 50 3 06105-002-19-87 Tempstar/Tempstar NB 208 60 1 06105-002-69-78 Tempstar/Tempstar NB 208 60 3 06105-002-69-78 Tempstar/Tempstar NB 230 50 1 06105-002-19-87 Tempstar/Tempstar NB 230 50 3 06105-002-19-87 Tempstar/Tempstar NB 230 60 1 06105-002-69-78 Tempstar/Tempstar NB 230 60 3 06105-002-69-78 Tempstar/Tempstar NB 380 50 3 06105-002-41-24 Tempstar/Tempstar NB 415 50 3 06105-002-41-24 Tempstar/Tempstar NB 440 50 3 06105-002-41-24 Tempstar/Tempstar NB 460 60 3 06105-121-64-21
Tempstar LT 208 50 1 06105-002-19-87 Tempstar LT 208 50 3 06105-002-19-87 Tempstar LT 208 60 1 06105-002-69-78 Tempstar LT 208 60 3 06105-002-69-78 Tempstar LT 230 50 1 06105-002-19-87 Tempstar LT 230 50 3 06105-002-19-87 Tempstar LT 230 60 1 06105-002-69-78 Tempstar LT 230 60 3 06105-002-69-78 Tempstar LT 380 50 3 06105-002-41-24 Tempstar LT 415 50 3 06105-002-41-24 Tempstar LT 440 50 3 06105-002-41-24 Tempstar LT 460 60 3 06105-121-64-21
Tempstar SDS 208 50 1 06105-002-19-87 Tempstar SDS 208 50 3 06105-002-19-87 Tempstar SDS 208 60 1 06105-002-69-78 Tempstar SDS 208 60 3 06105-002-69-78 Tempstar SDS 230 50 1 06105-002-19-87 Tempstar SDS 230 50 3 06105-002-19-87 Tempstar SDS 230 60 1 06105-002-69-78 Tempstar SDS 230 60 3 06105-002-69-78 Tempstar SDS 380 50 3 06105-002-41-24 Tempstar SDS 415 50 3 06105-002-41-24 Tempstar SDS 440 50 3 06105-002-41-24 Tempstar SDS 460 60 3 06105-121-64-21
Tempstar S 208 60 1 06105-002-69-78 Tempstar S 208 60 3 06105-002-69-78 Tempstar S 230 60 1 06105-002-69-78 Tempstar S 230 60 3 06105-002-69-78
Important note: When servicing a wash motor, it is important to refer to the wiring schematic found on the motor, to ensure that the motor is wired correctly. Different manufacturers of motors may not use the same wire color codes and therefore, your new motor, which may have been built by someone different than who built your original motor, may not connect using the same wires. Always refer to the wiring diagrams on the motor you are installing. If the motor you are installing has had the schemat­ic removed, contact Jackson MSC immediately for technical support.
Page 49
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
MOTOR & PUMP ASSEMBLY
41
Impeller Assembly, 60HZ
05700-002-81-86
Impeller Assembly, 50HZ
05700-002-41-49
Mechanical Seal, 60HZ 05330-002-34-22
Seal, 50HZ 05330-002-06-21
Other parts not shown.
Drain Plug, 60HZ
04730-002-81-89
Bracket, 50HZ
05700-002-06-22
Shaft Adapter, 50HZ
05700-011-95-49
Case O-Ring, 60HZ
05330-002-81-83
Seal Plate, 60HZ 05700-002-81-87
Gasket, 50HZ
05330-002-41-48
Case Capscrew, 60HZ
05305-002-81-88
Pump Casing 60HZ
05700-002-85-01
Motor Only, 60HZ 06105-002-79-61
Motor Only, 50HZ 06105-002-85-36
Complete Pump & Motor Assembly, 60HZ
06105-002-69-78
Pump Only Assembly, 60HZ
(Area indicated within box, Casing is included)
05700-002-79-51
Complete Pump & Motor Assembly, 50HZ
06105-002-19-87
Pump Only Assembly, 50HZ
(Area indicated within box, Casing is included)
05700-002-85-38
Pump Casing (Not shown), 50HZ
05700-002-41-50
Shim Kit, 60HZ
05700-002-82-58
Page 50
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
WASH HEATERS/RINSE HEATERS
42
The Tempstar models covered in this manual come supplied with various heaters, depending on the characteristics of the machine. To ensure that you order the correct heater for the model you are servicing, please refer to the following table:
Model Volts Hz Phase Wash Heater Rinse Heater (12 KW) Rinse Heater (14 KW)
Tempstar 208 50 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 208 50 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 208 60 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 208 60 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 230 50 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 230 50 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 230 60 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 230 60 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar 380 50 3 04540-002-44-31 04540-002-44-32 04540-121-63-38 Tempstar 415 50 3 04540-002-43-09 04540-002-43-10 04540-002-77-24 Tempstar 440 50 3 04540-121-65-99 04540-100-01-15 04540-121-63-39 Tempstar 460 60 3 04540-121-65-99 04540-100-01-15 04540-121-63-39
Tempstar LT 208 50 1 04540-121-47-39 Tempstar LT 208 50 3 04540-121-47-39 Tempstar LT 208 60 1 04540-121-47-39 Tempstar LT 208 60 3 04540-121-47-39 Tempstar LT 230 50 1 04540-121-47-39 Tempstar LT 230 50 3 04540-121-47-39 Tempstar LT 230 60 1 04540-121-47-39 Tempstar LT 230 60 3 04540-121-47-39 Tempstar LT 380 50 3 04540-002-44-31 Tempstar LT 440 50 3 04540-121-65-99 Tempstar LT 460 60 3 04540-121-65-99
Tempstar NB 208 50 1 04540-121-47-39 Tempstar NB 208 50 3 04540-121-47-39 Tempstar NB 208 60 1 04540-121-47-39 Tempstar NB 208 60 3 04540-121-47-39 Tempstar NB 230 50 1 04540-121-47-39 Tempstar NB 230 50 3 04540-121-47-39 Tempstar NB 230 60 1 04540-121-47-39 Tempstar NB 230 60 3 04540-121-47-39 Tempstar NB 380 50 3 04540-002-44-31 Tempstar NB 415 50 3 04540-002-43-09 Tempstar NB 440 50 3 04540-121-65-99 Tempstar NB 460 60 3 04540-121-65-99
Tempstar SDS 208 50 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 208 50 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 208 60 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 208 60 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 230 50 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 230 50 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 230 60 1 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 230 60 3 04540-121-47-39 04540-121-47-40 04540-121-63-38 Tempstar SDS 380 50 3 04540-002-44-31 04540-002-44-32 04540-121-63-38 Tempstar SDS 415 50 3 04540-002-43-09 04540-002-43-10 04540-002-77-24 Tempstar SDS 440 50 3 04540-121-65-99 04540-100-01-15 04540-121-63-39 Tempstar SDS 460 60 3 04540-121-65-99 04540-100-01-15 04540-121-63-39
Page 51
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR INCOMING PLUMBING/OUTLET PLUMBING ASSEMBLY
43
TEMPSTAR INCOMING PLUMBING
TEMPSTAR/TEMPSTAR SDS
OUTLET PLUMBING
15
4
9
10
16
1
7
3
2
6
5
4
4
8
9
10
11
10
14
13
17
13
9
18
12
12
10
Tube Length Chart
Item # Length (Inches)
11 3/4" x 36 1/4" Long 14 3/4" x 3 3/4" Long 16 3/4" x 30 3/4" Long 18 3/4" x 2 7/8" Long
Lower Outlet
Plumbing Assembly
5700-003-20-36
Upper Outlet
Plumbing Assembly
5700-003-20-37
Page 52
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR INCOMING PLUMBING/OUTLET PLUMBING ASSEMBLY/WPRK KIT OPTION
44
ITEM QTY DESCRIPTION Mfg. No.
1 1 Water Pressure Regulator, 3/4" NPT 06685-011-58-22 2 1 Valve, Ball, 1/4" NPT 04810-011-72-67 3 1 Gauge, Pressure, 0-100 PSI 06685-111-88-34 4 2 Nipple, Close, 3/4" NPT 04730-207-34-00 5 1 Tee, Brass, 3/4" NPT x 3/4" NPT x 1/4" NPT 04730-211-04-00 6 1 Valve, Solenoid, 3/4" NPT 04810-100-03-18 7 1 Nipple, Brass, 3/4" NPT x 2" Long 04730-207-46-00 8 1 Elbow, 3/4" NPT, Brass, Street 04730-206-04-34 9 3 Union, 3/4" NPT, Brass 04730-212-05-00
O-ring 05330-003­10 6 Adapter, 3/4" Male 04730-401-11-01 11 1 Tube, Copper See Chart 12 2 Elbow, 3/4" CU x CU, 90° 04730-406-16-01 13 2 Adapter, 3/4", 604-2 04730-401-10-01 14 1 Tube, Copper See Chart 15 1 Vacuum Breaker, 3/4" NPT 04820-002-53-77 16 1 Tube, Copper See Chart 17 1 Elbow, 3/4" NPT, 90°, Brass 04730-206-13-00 18 1 Tube, Copper See Chart
When servicing plumbing components, take care not to damage the threads of each individual item. Damaged threads can cause leaks and loss of pressure, which could adversely effect the performance of the Tempstar dishmachine. It is strongly rec­ommended that teflon thread tape, used in conservative amounts, be applied to threads when joining components together. It is not advised to use thread sealing compounds, sometimes referred to as “pipe dope”. Compounds can be ejected from the threads during the tightening process and become lodged in key components, thereby rendering them useless. Some of the components include the solenoid valve and the pressure gauge isolation ball valve.
Water Arrestor, 1/2” 06685-100-05-00
Tee, 3/4” x 3/4” x 1/2” 04730-211-06-00
Nipple, 3/4” NPT, Close, Brass
04730-207-34-00
WPRK KIT OPTION
Page 53
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR LT & TEMPSTAR NB INCOMING PLUMBING ASSEMBLY
45
ITEM QTY DESCRIPTION Mfg. No.
1 1 Vacuum Breaker, 3/4" NPT 04820-002-53-77 2 1 Elbow, Brass, Street, 3/4" NPT 04730-206-04-34 3 1 Nipple, Brass, 3/4" NPT x 3" Long 04730-011-38-29 4 1 Union, Brass, 3/4" NPT 04730-212-05-00 5 3 Nipple, Close, Brass, 3/4" NPT 04730-207-34-00 6 1 Valve, Solenoid, 3/4" NPT 04810-100-03-18 7 1 Tee, Brass, 3/4" NPT x 3/4" NPT x 1/4" NPT 04730-211-04-00 8 1 Pressure Gauge, 0-100 PSI 06685-111-59-66 9 1 Valve, Ball, Bronze, 1/4" NPT 04810-011-72-67 10 1 Water Pressure Regulator, 3/4" NPT 06685-011-58-22
2
3
4 5 6
7
5
5
81 9
10
Page 54
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS INCOMING PLUMBING ASSEMBLY
46
ITEM QTY DESCRIPTION Mfg. No.
1 1 Gauge, Pressure, 0-100 PSI 06685-111-88-34 2 1 Valve, Ball, 1/4" NPT 04810-011-72-67 3 1 Tee, 1/4" x 1/4" x 1/4" Brass 04730-011-51-20 4 2 Nipple, 1/4" Close Brass 04730-207-02-00 5 1 Regulator, Pressure 06685-111-48-54 6 1 Gauge, Pressure, 0-100 PSI 1/8" 06685-011-48-32 7 1 Reducer, 1/4" Male x 3/8" Female Brass 04730-011-59-40 8 1 Fitting, 3/8" Y-Branch 04730-111-58-21 9 1 Valve, Solenoid, 3/4" NPT 04810-100-03-18 10 2 Nipple, Close, 3/4" NPT 04730-207-34-00 11 1 Tee, Brass, 3/4" NPT x 3/4" NPT x 1/4" NPT 04730-211-04-00 12 1 Water Pressure Regulator, 3/4" NPT 06685-011-58-22
1
2
3
4
6
5
78
9
10
11
10
12
Please refer to page 41, for component numbers 7 through 14 to connect to the Booster Tank. Refer to page 43 for the Outlet Plumbing Assembly.
Page 55
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
3/4” SOLENOID VALVE & 3/4” NPT VACUUM BREAKER REPAIR PARTS KITS
47
Screw
Data Plate
Coil & Housing
Valve Bonnet
Spring 06401-003-07-40
Plunger 06401-003-07-40
O-Ring 06401-003-07-42
Diaphragm
Retainer
Diaphragm 06401-003-07-42
Screen
Retainer
Mesh Screen
Valve Body
Complete 110 Volt Solenoid Valve Assembly
04810-100-53-00
Coil & Housing only
06401-003-07-43
Complete 240 Volt Solenoid Valve Assembly
04810-100-03-18
Coil & Housing only
06401-003-07-44
Complete Vacuum Breaker Assembly
04820-002-53-77
Components of Repair Kit
06401-003-06-24
Cap Screw
Data Plate
Cap
O-Ring
Plunger
Body
Cap Retainer
Page 56
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
WASH & RINSE ARM/MANIFOLD ASSEMBLIES
13
18
20
11
12
15
14
2, 3, 4
7
16, 8
6, 10
5
9
7
1
DETAIL “B”
WASH ARMS & MANIFOLD
DET
AIL “A”
FINAL RINSE ARMS & MANIFOLD
10
10
10
10
5
17
17
16
2, 3, 19
9, 17
9, 17
1
Rinse Injector Weldment
1 per machine
05700-021-47-65
Rinse Injector Gasket
2 per machine
05330-111-42-81
Plug, 1/8” NPT, Brass
3 per Rinse Injector
04730-209-07-37
48
Page 57
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
WASH & RINSE ARM/MANIFOLD ASSEMBLIES (CONTINUED)
49
ITEM QTY DESCRIPTION Mfg. No.
1 1 Upper Manifold 05700-031-34-82 2 4 Nut, 3/8"-16 S/S Hex 05310-276-01-00 3 4 Lockwasher,3/8 05311-276-01-00 4 2 Bolt, Hex 3/8”-16 x 7/8" Long 05306-011-36-95 5 2 O Ring 05330-111-35-15 6 1 Positioning Bracket, Manifold Tube 05700-011-34-63 7 1 Tube, Wash Manifold 05700-131-15-07 8 2 Gasket, Manifold 05700-111-35-03 9 2 Wash Arm 05700-021-35-93 10 5 Locknut, 1/4"-20 S/S Hex with Nylon Insert 05310-374-01-00 11 2 Clip, Retaining, Rinse Head Bushing 05340-112-01-11 12 4 Rinse Arm Washer 05330-011-42-10 13 2 Bushing, Rinse Head 05700-021-33-84 14 2 Rinse Arm 05700-031-49-58 15 4 Plug, Rinse Arm 04730-609-04-00 16 1 Lower Wash Manifold 05700-031-46-00 17 2 Bearing Assembly 05700-021-35-97 17a 1 Hub Nut 05700-011-35-94 17b 1 Hub Bushing 05700-011-35-96 17c 1 Hub Spindle 05700-011-35-95 17d 1 Ring, Retainer 05340-011-37-81 17e 15 3/16" Stainless Steel Ball 03120-100-02-00 17f 20 1/8" Stainless Steel Ball 03120-011-37-82 18 1 Rinse Manifold Assembly 05700-021-47-61 19 2 Bolt, Hex 3/8”-16 x 1 1/4" Long 05305-276-10-00 20 2 Bearing, Rinse Head 03120-002-72-24
17b
17a
17c
17f
17e
17d
9
1 or 16
EXPLODED VIEW OF
ITEM 17
Page 58
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS DISPENSER ASSEMBLY
50
1
2
3
4
5
6
7
8
1
See section entitled “Cam
Holder Assembly”.
9
10
11
See section entitled “Dispenser
Plumbing Assembly”
13
12
See section entitled
“Feeder Pump”.
14
15
16
See section entitled
“Lower Dispenser
Assembly”.
Page 59
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS DISPENSER ASSEMBLY (CONTINUED)
51
ITEM QTY DESCRIPTION Mfg. No.
1 3 Screw, 6-32 x 3/4" Long 05305-171-07-00 2 1 Lockwasher, #6, External Tooth 05311-271-02-00 3 1 Rinse Cylinder Bracket 05700-011-59-72 4 1 Rinse Additive Screen 05930-011-48-66 5 1 Rinse Cylinder Cover 09515-011-49-01 6 1 Rinse Additive Cylinder 09515-031-49-00 7 1 Decal, Rinse Additive 09905-011-59-80 8 1 Rinse Aid Nozzle 04730-011-50-03 9 1 Detergent Screen 05335-011-48-65 10 1 Detergent Spray Nozzle 04730-011-50-04 11 1 Detergent Flush Pipe 05700-011-51-52 12 1 Decal, Detergent Additive 09905-011-59-79 13 3 Light, Red 05945-011-48-96 14 1 Motor, Feeder Pump 06105-111-51-02 15 1 Dispenser Molding 09515-031-48-62 16 1 Sonalert 05945-011-48-97
ITEM QTY DESCRIPTION Mfg. No.
17 2 Locknut, 4-40 05310-279-06-00 18 1 Lockwasher, 4-40 05311-011-59-71 19 1 Screw, 4-40 x 3/4" Long 05305-011-59-64 20 1 Spring, .023 Wire 05340-111-58-02 21 1 Magnet, 3/16" x 1" Long Bar 05930-011-48-81 22 1 Holder, Cam Magnet 05340-011-48-80 23 1 Cam Holder 05340-011-59-62 24 1 Switch, 5A 05930-011-48-83 25 2 Screw, 4-40 x 3/8" Long 05305-011-59-70
17
18
19
20
21
23
22
24
25
CAM HOLDER ASSEMBLY
Page 60
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS DISPENSER ASSEMBLY (CONTINUED)
52
26
27
28
29
FEEDER PUMP
30
31
32
33
34
35
36
37 & 38
37 & 38
DISPENSER PLUMBING ASSEMBLY
ITEM QTY DESCRIPTION Mfg. No.
26 1 Plate, Solenoid Valve Mounting 05700-031-58-16 27 1 Plate, Pump Mounting 05700-011-57-88 28 1 Peristaltic Pump 04320-111-51-03 29 2 Ferrule Nut, Chemical Tube Connector 04730-609-16-00
Page 61
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS DISPENSER ASSEMBLY (CONTINUED)
53
ITEM QTY DESCRIPTION Mfg. No.
39 1 Decal, Dispenser Front 09905-021-50-18 40 1 Dispenser Mounting Plate 05700-031-50-12 41 2 Screw, 6-32 x 3/8" Long 05305-171-07-00 42 1 Switch, Float 05930-011-48-98 43 1 Reservoir 09515-031-48-63 44 3 Screw, 10-32 x 1/2" Long 05305-011-39-36 45 3 Lockwasher, #10 External Tooth 05311-273-03-00 46 1 Reservoir Clip 05700-021-49-26 47 1 Jam Nut, 1/8"-27 05310-011-58-00 48 1 Rinse Additive Pickup Tube 05700-011-50-14 49 1 Ferrule Nut, Chemical Tube Connector 04730-609-16-00 50 1 Panel, Dispenser Sliding Cover 05700-011-51-19 51 1 Fitting, Liquid Tight 05975-011-49-03 52 1 Elbow, 1/4" NPT x 3/8" Compression 04730-111-59-34 53 1 Insert, 3/8" Tubing P/P 04730-111-59-35
39
40
41
42
43
44 & 45
47
46
49 48
50
51
53
52
LOWER DISPENSER ASSEMBLY
ITEM QTY DESCRIPTION Mfg. No.
30 2 1/4" NPT Vacuum Breaker 04810-011-51-62 31 2 Elbow, 3/8" Comp. X 1/4" NPT, 90°, Brass 04730-111-58-18 32 2 Nipple, 1/4" x 6" Brass 04730-011-79-29 33 1 Plug, Hunky 05975-011-59-49 34 2 Valve, Solenoid 04810-011-48-99 35 1 Grommet, 1.25" O.D. x 1.00" I.D. 05975-111-58-01 36 1 Fitting, Liquid Tight 05975-011-49-03 37 12 Screw, 10-32 x 1/2" Long 05305-011-39-36 38 12 Lockwasher, #10 External Tooth 05311-273-03-00
Page 62
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
TEMPSTAR SDS DISPENSER ASSEMBLY (CONTINUED)
54
ITEM QTY DESCRIPTION Mfg. No.
54 1 Thermal Barrier Box Assembly 05700-021-48-14 55 1 Thermal Box Top Weldment 05700-021-50-64 56 1 Thermal Box Bottom Weldment 05700-021-50-65 57 1 Foam, 1" Thick 05640-011-49-07 58 3 Screw, 10-32 x 3/8" Phillips Pan Head 05305-173-26-00 59 3 Lockwasher, #10 Internal Tooth 05311-273-03-00 60 1 Valve, Check 04820-111-51-14 61 1 Fitting, Outlet Elbow 04820-111-51-18 62 1 Nut, P/P For 1/8” Tubing 04730-011-59-45
Other components not shown:
- - Sensor, Detergent 06680-011-49-83
- - Kit, Detergent Sensor Mounting 04730-111-51-17
- - Gasket, 1/8” Thick 05330-021-51-08
54 55 56 57 58 59
60, 61, 62
Page 63
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
SAFETY DOOR INTERLOCK (SDI) /EXHAUST FAN CONTROL/TRANSFORMER MOUNTING BOX
55
Safety Door Interlock Box Bottom
05700-001-21-26
Safety Door Interlock Box Cover
05700-001-21-27
Other Safety Door Interlock (SDI) components (not shown):
DESCRIPTION Mfg. No.
Pipe Clamp (found on the side of the machine) 05700-000-35-05 Solenoid, Electrical Interlock Option 04810-100-61-33 Relay 05945-111-47-51
Exhaust Fan
Control
Delay Timer
05945-011-65-44
Exhaust Fan
Control
2” Din Rail
05700-002-36-09
Exhaust Fan
Control
Terminal Board
05940-011-84-41
415/440/460V
Transformer
05950-111-65-93
380V Transformer
05950-111-64-17
2 Amp Circuit Breaker
05925-111-64-18
Transformer Mounting Bracket
05700-031-62-82
Transformer Mounting Box
05700-002-10-01
Transformer Mounting Box Top
(not shown)
05700-000-78-53
Page 64
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
FALSE PANEL INSTALLATION
56
1. Loosen the rack assembly from the unit.
2. False panel will mount to the rack; inside the dishmachine.
3. Position panel in unit on side to be closed.
4. Hold panel against side of dishmachine and push up.
5. Panel will clip inside the unit under the edge of the hood.
6. Holes in false panel will line up with rack assembly holes.
7. Re-install screws for rack assembly which will secure false panel to unit.
8. Re-assemble the rack track in an “L” shape for a corner opera­tion.
Bottom of side panel.
Insert this side first.
False panel positioned in unit.
Rack rail removed & reposi­tioned for a corner operation.
Left & Front False Panel
Weldment
05700-002-75-52
Right False Panel Weldment
(Use with Overflow Tube Lifter)
05700-002-98-85
Left & Front False Panel Kit
05700-002-75-59
Right False Panel Kit
(Use with Overflow Tube Lifter)
05700-002-98-86
Page 65
A GO*BOX is a kit of the most needed parts for a particular model or model family to successfully effect a repair in the first call 90% or more of the time.
The following components may be ordered together using the following Mfg. No.: 06401-002-15-00.
ITEM QTY DESCRIPTION Mfg. No.
1 1 Contactor, Rinse/Wash Heater 05945-109-01-69 2 1 Contactor, Wash Motor 05945-002-74-20 3 1 Gauge, Pressure, 0-100 PSI 06685-111-88-34 4 1 Thermometer, 96" Capillary 06685-111-68-49 5 1 Thermometer, 48" Capillary 06685-111-68-48 6 1 Thermostat, Rinse Operating 06401-140-00-33 7 1 Thermostat, Wash Operating 06401-140-00-32 8 1 Thermostat, Hi-Limit 05930-011-49-43 9 1 Liquid Level Control 06680-200-08-21 10 1 Probe, water level sensing 06680-200-02-68 11 1 Magnet,Door 05930-111-51-68 12 6 Glide, Door Edge 05700-111-33-59 13 2 O-Ring Wash Manifold 05330-111-35-15 14 1 Relay,Control 240V 50/60Hz 05945-111-47-51 15 1 Seal, Mechanical Pump (S/S Pumps) 05330-002-34-22 16 1 O-Ring, Wash Pump Gasket 05330-002-81-83 17 1 Switch, Door, Magnetic Reed 05930-111-51-69 18 2 Snap Ring, Retaining, Rinse Arm 05340-112-01-11 19 1 Bearing Assembly, Wash Arm 05700-021-35-97 20 1 Switch, Power Push Button 05930-002-29-13 21 1 Timer, Universal 05945-003-33-10 22 4 Washer, Rinse Arm Nylatron 05330-011-42-10 23 1 Vacuum Breaker 3/4" Brass 04820-002-53-77 24 1 Valve, Solenoid, 3/4", 220V 04810-100-03-18
* 1 Pump & Motor Assembly, S/S 06105-002-69-78
Special pricing available when purchased with above GO*BOX. Call for details.
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
GO*BOX COMPONENTS
57
Page 66
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 5: PARTS SECTION
58
DRAIN QUENCH ASSEMBLY
From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” Reducer. Position the bulb of the thermostat so that it rests approximately 1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.
Thermostat 05930-003-13-65
Solenoid Valve 04810-100-09-18
To Cold Water Supply
Nipple, Close, 1/2” NPT (Not Shown) 04730-207-15-00
Valve, Check, 1/2” (Not Shown) 04820-002-55-77
Lid, Drain Quench 05700-002-67-16
Box, Drain Quench 05700-002-69-96
Reducer, 1-1/2” to 1/2” 04730-002-55-75
Tee, 1-1/2” x 1-1/2” x 1-1/2”
04730-011-69-93
Modified Compression
Fitting
05700-001-16-52
Reducer, 1-1/2” x 1/4”
04730-002-55-76
To Dishmachine Drain
Nipple, 1-1/2” NPT
04730-207-40-00
Elbow, 1-1/2” 90° Street
04730-206-32-00
Drain Quench
Assembly
06401-002-59-52
Page 67
59
SECTION 6A:
ELECTRICAL SCHEMATICS
FOR TOP MOUNT UNITS
Page 68
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT W/ CYCLE SWITCHES) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
60
Page 69
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT W/ CYCLE SWITCHES) 460 VOLT - 60 HERTZ -THREE PHASE
61
Page 70
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & NB (TOP MOUNT W/ CYCLE SWITCHES) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
62
Page 71
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & NB (TOP MOUNT W/ CYCLE SWITCHES) 460 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
63
Page 72
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT UNIVERSAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
64
Page 73
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT UNIVERSAL TIMER) 380-440-460 VOLT - 50/60 HERTZ - THREE PHASE
65
Page 74
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (TOP MOUNT UNIVERSAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
66
Page 75
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (TOP MOUNT UNIVERSAL TIMER) 380-415-440-460 VOLT - 50/60 HERTZ - THREE PHASE
67
Page 76
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT MECHANICAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
68
Page 77
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT MECHANICAL TIMER) 380-440-460 VOLT - 50/60 HERTZ - THREE PHASE
69
Page 78
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (TOP MOUNT MECHANICAL TIMER) 415 VOLT - 50/60 HERTZ - THREE PHASE - 5 WIRE
70
Page 79
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (TOP MOUNT MECHANICAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
71
Page 80
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (TOP MOUNT MECHANICAL TIMER) 380-415-440-460 VOLT - 50/60 HERTZ - THREE PHASE
72
Page 81
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR S (TOP MOUNT MECHANICAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
73
Page 82
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR S (TOP MOUNT UNIVERSAL TIMER) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
74
Page 83
75
SECTION 6B:
ELECTRICAL SCHEMATICS
FOR SIDE MOUNT UNITS
Page 84
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (SIDE MOUNT) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
76
Page 85
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (SIDE MOUNT) 380 VOLT - 50 HERTZ - THREE PHASE
77
Page 86
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR (SIDE MOUNT) 440-460 VOLT - 50/60 HERTZ - THREE PHASE
78
09905-031-66-00
Page 87
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (SIDE MOUNT) 208-230 VOLT - 50/60 HERTZ - SINGLE & THREE PHASE
79
Page 88
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR LT & TEMPSTAR NB (SIDE MOUNT) 380-440-460 VOLT - 50/60 HERTZ - THREE PHASE
80
Page 89
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR SDS 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE
81
Page 90
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR SDS 380-440-460 VOLT - 50/60 HERTZ - THREE PHASE
82
Page 91
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR SDS 380-415 VOLT - 50 HERTZ - THREE PHASE - 5 WIRE
83
Page 92
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
TEMPSTAR SDS DISPENSER SCHEMATIC
84
09905-011-48-52
Page 93
85
SECTION 6C:
ELECTRICAL SCHEMATICS
FOR OPTIONS
Page 94
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
SDI OPTION
86
Page 95
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 6: ELECTRICAL SCHEMATICS
87
EXHAUST FAN HOOKUP/DRAIN QUENCH OPTIONS
Page 96
88
SECTION 7:
JACKSON MAINTENANCE &
REPAIR CENTERS
Page 97
ALABAMA
JONES-McLEOD APPLIANCE SVC
1616 7TH AVE. NORTH BIRMINGHAM, AL 35203 (205) 251-0159 800-821-1150 FAX: (205) 322-1440 service@jones-mcleod.com
JONES-McLEOD APPLIANCE SVC
854 LAKESIDE DRIVE MOBILE, AL 36693 (251) 666-7278 800-237-9859 FAX: (251) 661-0223
ALASKA
RESTAURANT APPLIANCE SERVICE
7219 ROOSEVELT WAY NE SEATTLE, WA 98115 (206) 524-8200 800-433-9390 FAX: (206) 525-2890 info@restappl.com
ARIZONA
AUTHORIZED COMMERCIAL FOOD EQMT. SVC
4832 SOUTH 35TH STREET PHOENIX, AZ 85040 (602) 234-2443 800-824-8875 FAX: (602) 232-5862 acsboss@aol.com
GCS SERVICE INC.
PHOENIX, AZ (602) 474-4510 800-510-3497 FAX: (602) 470-4511
ARKANSAS
BROMLEY PARTS & SVC
10TH AND RINGO P.O. BOX 1688 LITTLE ROCK, AR 72202 (501) 374-0281 800-482-9269 FAX: (501) 374-8352 service@bromleyparts.com parts@bromleyparts.com
GCS SERVICE,INC.
3717 CHERRY ROAD MEMPHIS, TN 38118 (901) 366-4587 800-262-9155 FAX: (901) 366-4588
CALIFORNIA
BARKERS FOOD MACHINERY SERVICES
5367 SECOND STREET IRWINDALE, CA 91706 (626) 960-9390 800-258-6999 FAX: (626) 337-4541 service@barkers.com
GCS SERVICE INC.
LOS ANGELES, CA (213) 683-2090 800-327-1433 FAX: (213) 683-2099
GCS SERVICE INC.
SANTA ANA, CA (714) 542-1798 800-540-0719 FAX: (714) 542-4787
GCS SERVICE INC.
S. SAN FRANCISCO, CA (650) 635-0720 800-969-4427 FAX: (650) 871-4019
COMMERCIAL APPLIANCE SERVICE, INC.
6507 PACIFIC AVENUE, SUITE 102 STOCKTON, CA 95207 (916) 567-0203 (800) 464-2222 (916) 567-0266 FAX
GCS SERVICE INC.
SAN DIEGO, CA (858) 549-8411 800-422-7278 FAX: (858) 549-2323
INDUSTRIAL ELECTRIC SVC.
5662 ENGINEER DRIVE HUNTINGTON BEACH, CA 92649 (714) 379-7100 (800-457-3783 FAX: (714) 379-7109
P & D APPLIANCE SVC
100 SOUTH LINDEN AVE. S. SAN FRANCISCO, CA 94080 (650) 635-1900 800-424-1414 FAX: (650) 635-1919 pndappl@aol.com
P & D APPLIANCE
4220-C ROSEVILLE ROAD NORTH HIGHLANDS, CA 95660 (916) 974-2772 800-824-7219 FAX:(916) 974-2774
COMMERCIAL APPLIANCE SERVICE, INC.
281 LATHROP WAY, #100 SACRAMENTO, CA 95815 (916) 567-0203 (800) 464-2222 (916) 567-0324 FAX
COLORADO
GCS SERVICE INC.
SHERIDAN, CO (303) 371-9054 800-972-5314 FAX: (303) 371-4754
HAWKINS COMMERCIAL APPLIANCE SERVICE
3000 S. WYANDOT ST. ENGLEWOOD, CO 80110 (303) 781-5548 (800) 624-2117 FAX: (303) 761-5561 johns@hawkinscommercial.com
METRO APPLIANCE SERVICE
1640 S BROADWAY DENVER, CO 80210 (303) 778-1126 800-525-3532 FAX: (303) 778-0268 metroappls@aol.com
CONNECTICUT
GCS SERVICE INC.
HARTFORD, CT (860) 549-5575 800-423-1562 FAX: (860) 527-6355
SUPERIOR KITCHEN SER­VICE INC.
22 THOMPSON ROAD WINDSOR, CT 06088 (888) 590-1899 (888) 590-1996 FAX
DELAWARE
FOOD SERVICE EQMT.
2101 PARKWAY SOUTH BROOMALL, PA 19008 (610) 356-6900 FAX: (610) 356-2038 dancerule@aol.com
GCS SERVICE INC.
PHILADELPHIA, PA (215)925-6217 800-441-9115 FAX: (215) 925-6208
ELMER SCHULTZ SERVICE
36 BELMONT AVE. WILLMINGTON, DE 19804 (302) 655-8900 800-225-0599 FAX: (302) 656-3673 elmer2@erols.com
EMR SERVICE DIVISION
106 WILLIAMSPORT CIRCLE SALISBURY, MD 21804 (410) 543-8197 FAX: (410) 548-4038
FLORIDA
COMMERCIAL APPLIANCE SERVICE
8416 LAUREL FAIR CIRCLE BLDG 6, SUITE 114 TAMPA, FL 33610 (813) 663-0313 800-282-4718 FAX: (813) 663-0212 commercialappliance@world­net.att.net
GCS SERVICE INC
MIAMI, FL (305) 621-6666 800-766-8966 FAX: (305) 621-6656
GCS SERVICE INC
ORLANDO, FL (407) 841-2551 800-338-7322 FAX: (407) 423-8425
NASS PARTS AND SERVICE, INC.
1144 BELVILLE ROAD, UNIT 359 DAYTONA BEACH, FL 32114 (386) 226-2642 (800) 432-2795 (386) 736-7695 FAX
GCS SERVICE INC
TAMPA, FL (813) 626-6044 800-282-3008 FAX: (813) 621-1174
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS
ALABAMA TO FLORIDA
89
Page 98
JONES-McLEOD APPLIANCE SVC
854 LAKESIDE DRIVE MOBILE, AL 36693 (251) 666-7278 800-237-9859 FAX: (251) 661-0223 service@jones-mcleod.com
NASS PARTS AND SERVICE, INC.
1108 SOUTH WOODS AVENUE ORLANDO, FL 32805 (407) 425-2681 (800) 432-2795 (407) 425-3463 FAX
NASS PARTS AND SERVICE, INC.
1376 HEIDE AVENUE PALM BAY, FL 32907 (321) 952-2012 (800) 432-2795 (321) 953-0266 FAX
GEORGIA
GCS SERVICE INC
ATLANTA, GA (770) 452-7322 800-334-3599 FAX: (770) 452-7473
HERITAGE FOODSERVICE GROUP OF ATLANTA
2100 NORCROSS PKWY. SUITE 130 NORCROSS, GA 30071 (770) 368-1465 866-388-9837 FAX: (866) 388-9838
WHALEY FOODSERVICE REPAIRS
109-A OWENS INDUSTRIAL DRIVE SAVANNAH, GA 31405 (912) 447-0827 888-765-0036 FAX: (912) 447-0826
PIERCE PARTS & SERVICE
2422 ALLEN ROAD MACON, GA 31216 (478) 781-6003 800-368-2512 FAX: (478) 781-7186
HAWAII
FOOD EQMT. PARTS & SERVICE CO.
300 PUUHALE RD. HONOLULU, HI 96819 (808) 847-4871 FAX: (808) 842-1560 fepsco@hula.net
IDAHO
RESTAURANT APPLIANCE SVC.
7219 ROOSEVELT WAY NE SEATTLE, WA 98115 (206) 524-8200 800-433-9390 FAX: (206) 525-2890 info@restappl.com
RON'S SERVICE
703 E 44TH STREET STE 10 GARDEN CITY, ID 83714 (208) 375-4073 FAX: (208) 375-4402
ILLINOIS
CONES REPAIR SVC.
2408 40TH AVE. MOLINE, IL 61265 (309) 797-5323 800-716-7070 FAX: (309)797-3631 jackb@cones.com
EICHENAUER SERVICES INC.
130 S OAKLAND ST. DECATUR, IL 62522 (217) 429-4229 800-252-5892 FAX: (217) 429-0226 esi@esiquality.com
GCS SERVICE INC.
ELMHURST, IL (630) 941-7800 800-942-9689 FAX: (630) 941-6048
GCS SERVICE INC.
ST. LOUIS, MO (314) 683-7444 800-284-4427 FAX: (314) 638-0135
GENERAL PARTS, INC.
248 JAMES STREET BENSONVILLE, IL 60106 (630) 595-3300 (800) 880-3604 FAX: (630)595-0006
INDIANA
GCS SERVICE INC.
INDIANAPOLIS, IN (317) 545-9655 800-727-8710 FAX: (317) 549-6286
B622 LA PAS TRAIL INDIANAPOLIS, IN 46268 (317) 290-8060 (800) 410-9794 (317) 290-8085 FAX
IOWA GOODWIN TUCKER GROUP
2900 DELAWARE AVENUE
DES MOINES, IA 50317 (515) 262-9308 800-372-6066 FAX: (515) 262-2936 parts@goodwintucker.com
CONES REPAIR SVC.
1056 27TH AVENUE SW CEDAR RAPIDS, IA 52404 (319) 365-3325 800-747-3326 FAX: (319) 365-0885
KANSAS
GCS SERVICE INC.
KANSAS CITY, MO (816) 920-5999 800-229-6477 FAX: (816) 920-7387
GENERAL PARTS, INC.
1101 E. 13TH STREET KANSAS CITY, MO 64106 (816) 421-5400 (800) 279-9967 (816) 421-1270 FAX
KENTUCKY
CERTIFIED SERVICE CENTER
127 DISHMAN LANE BOWLING GREEN, KY 42101 (270) 783-0012 (877) 907-0012 FAX: (270) 783-0058
CERTIFIED SERVICE CENTER RAMCO BUSINESS PARK
4283 PRODUCE ROAD LOUISVILLE, KY 40218 (502) 964-7007 800-637-6350 FAX: (502) 964-7202 cwalker@certifiedsc.com droenigk@certifiedsc.com
CERTIFIED SERVICE CENTER
1051 GOODWIN DRIVE LEXINGTON, KY 40505 (606) 254-8854 800-432-9269 FAX: (606) 231-7781 jatkins@certifiedsc.com
GCS SERVICE INC.
LOUISVILLE, KY (502) 367-1788 800-752-6160 FAX: (502) 367-0400
GCS SERVICE INC.
LEXINGTON, KY (606) 255-0746 800-432-9260 FAX: (606) 255-0748
LOUISIANA
HERITAGE SERVICE GROUP
1532 RIVER OAKS WEST NEW ORLEANS, LA 70123 (504) 734-8864 (800) 499-2351 (504) 733-2559 FAX
MAINE
GCS SERVICE INC.
CHELSEA, MA (617) 889-9393 800-225-1155 FAX: (617) 889-1222
MASSACHUSETTS RESTAU­RANT SUPPLY
34 SOUTH STREET SOMERVILLE, MA 02143 (617) 868-1930 800-338-6737 FAX: (617) 686-5331
PINE TREE FOOD EQUIP­MENT
175 LEWISTON ROAD GRAY, ME 04039 (207) 657-6400 (800) 540-5427 (207) 657-5464 FAX
MARYLAND
EMR SERVICE DIVISION
700 EAST 25TH STREET BALTIMORE, MD 21218 (410) 467-8080 800-879-4994 FAX: (410) 467-4191 baltparts@emrco.com
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS
FLORIDA TO MARYLAND
90
Page 99
EMR SERVICE DIVISION
106 WILLIAMSPORT CIRCLE SALISBURY, MD 21804 (410) 543-8197 888-687-8080 FAX: (410) 548-4038 baltparts@emrco.com
EMR SERVICE DIVISION
5316 Sunnyside Ave. Beltsville, MD 20715 (301) 931-7000 800-348-2365 FAX: (301) 931-3060 baltparts@emrco.com
GCS SERVICE INC.
SILVER SPRING, MD (301) 585-7550 (DC) (410) 792-0338 (BALT) (800) 638-7278 FAX: (301) 495-4410
MASSACHUSETTS
ACE SERVICE CO.
95 HAMPTON AVE. NEEDHAM, MA 02494 (781) 449-4220 800-225-4510 MA & NH FAX: (781) 444-4789 taceservice@aol.com
MASSACHUSETTS RESTAU­RANT SUPPLY
34 SOUTH STREET SOMERVILLE, MA 02143 (617) 868-1930 800-338-6737 FAX: (617) 868-5331
GCS SERVICE INC.
CHELSEA, MA (617) 889-9393 800-225-1155 FAX: (617) 889-1222
GCS SERVICE INC.
HARTFORD, CT (860) 549-5575 800-723-1562 FAX: (860) 527-6355
SUPERIOR KITCHEN SER­VICE INC.
399 FERRY STREET EVERETT, MA 02149 (617) 389-1899 (888) 590-1899 (617) 389-1996 FAX
MICHIGAN
GCS SERVICE INC.
LIVONIA, MI (248) 426-9500 800-772-2936 FAX: (248) 426-7555
JACKSON SERVICE COMPA­NY
3980 BENSTEIN RD. COMMERCE TWSHP, MI 48382 (248) 363-4159 800-332-4053 FAX: (248) 363-5448
GCS SERVICE INC.
GRAND RAPIDS, MI (616) 241-0200 800-823-4866 FAX: (616) 241-0541
MINNESOTA
GCS SERVICE INC.
MINNEAPOLIS, MN (612) 546-4221 800-345-4221 FAX: (612) 546-4286
GENERAL PARTS, INC.
11311 HAMPSHIRE AVENUE SOUTH BLOOMINGTON, MN 55438­2456 (952) 944-5800 (800) 279-9980 (800) 279-9980 FAX
MISSISSIPPI
GCS SERVICE INC.
JACKSON, MS (601) 956-7800 800-274-5954 FAX: (601) 956-1200
GCS SERVICE INC.
MEMPHIS, TN (901) 366-4587 800-262-9155 FAX: (901) 366-4588
MISSOURI
GCS SERVICE INC.
KANSAS CITY, MO (816) 920-5999 800-229-6477 FAX: (816) 920-7387
GCS SERVICE INC.
ST. LOUIS, MO (314) 638-7444 800-284-4427 FAX: (314) 638-0135
KAEMMERLIN PARTS & SVC.
2728 LOCUST STREET ST. LOUIS, MO 63103 (314) 535-2222 FAX: (314) 535-6205 petek@kps.stl.com
GENERAL PARTS, INC.
1101 EAST 13TH STREET KANSAS CITY, MO 64106 (816) 421-5400 (800) 279-9967 (816) 421-1270 FAX
MONTANA
RESTAURANT APPLIANCE SVC.
7219 ROOSEVELT WAY NE SEATTLE, WA 98115 (206) 524-8200 800-433-9390 FAX: (206) 525-2890 info@restappl.com
NEBRASKA
GOODWIN - TUCKER GROUP
7535 D STREET OMAHA, NE 68124 (402) 397-2880 800-228-0342 FAX: (402) 397-2881 askme@goodwintucker.com
NEVADA
HI TECH COMMERCIAL SER­VICE
1840 STELLA LAKE STREET NORTH LAS VEGAS, NV 89106 (702) 649-4616 (877) 924-4832 FAX: (702) 649-4607 larry@hitechnv.com
5454 LOUIE LANE RENO, NV 89511 (775) 852-9696 FAX: (775) 852-5104
GCS SERVICE INC.
LAS VEGAS, NV (702) 450-3495 800-500-9060 FAX: (702) 450-3491
NEW HAMPSHIRE
GCS SERVICE INC.
CHELSEA, MA (617)889-9393 800-225-1155 FAX: (617) 889-1222
ACE SERVICE CO.
95 HAMPTON AVE. NEEDHAM, MA 02494 (781) 449-4220 800-225-4510 MA & NH FAX: (781) 444-4789 taceservice@aol.com
MASSACHUSETTS RESTAU­RANT SUPPLY
34 SOUTH STREET SOMERVILLE, MA 02143 (617) 868-1930 800-338-6737 FAX: (617) 868-5331
NEW JERSEY
JAY HILL REPAIRS
90 CLINTON RD. FAIRFIELD, NJ 07004 (973) 575-9145 800-836-0643 FAX: (973) 575-5890 jhrepair@aol.com
GCS SERVICE INC.
EAST RUTHERFORD, NJ (973) 614-0003 800-399-8294 FAX: (973) 614-0230
GCS SERVICE INC.
PHILADELPHIA, PA (215) 925-6217 800-441-9115 FAX: (215) 925-6208
ELMER SCHULTZ SERVICES
201 W. WASHINGTON AVE. PLEASANTVILLE, NJ 08232 (609) 641-0317 800-378-1641 FAX:(609) 641-8703 elmer2@erols.com
NEW YORK
APPLIANCE INSTALLATION AND SERVICE CORP.
1336 MAIN STREET BUFFALO, NY 14209 (716) 884-7425 800-722-1252 FAX: (716) 884-0410 ais@worldnet.att.net
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS
MARYLAND TO NEW YORK
91
Page 100
B.E.S.T. INC.
3003 GENESEE STREET BUFFALO, NY 14225 (716) 893-6464 800-338-5011 FAX: (716) 893-6466 bestserv@aol.com
DUFFY'S EQUIPMENT SVC.
3138 ONEIDA STREET SAUQUOIT, NY 13456 (315) 737-9401 800-443-8339 FAX: (315) 737-7132 duffyequip@aol.com
NORTHERN PARTS & SVC.
21 NORTHERN AVENUE PLATTSBURGH, NY 12903 (518) 563-3200 800-634-5005 FAX: (800) 782-5424 info@northernparts.com
GCS SERVICE INC.
BROOKLYN, NY (718) 486-5220 800-969-4271 FAX: (718) 486-6772
ALL SERVICE KITCHEN
EQUIPMENT REPAIR 10 CHARLES ST. NEW HYDE PARK, NY 11040 (516) 378-1176 FAX: (516) 378-1735
ALL ISLAND REPAIRS
40-9 BURT DRIVE DEER PARK, NY 11729 (631) 242-5588 FAX: (631) 242-6102
NORTH CAROLINA
AUTHORIZED APPLIANCE
SERVICECENTER 1020 TUCKASEEGEE RD. CHARLOTTE, NC 28208 (704) 377-4501 (800) 532-6127 FAX:(704) 377-4504
AUTHORIZED APPLIANCE
SERVICECENTER 800 N. PERSON ST. RALEIGH, NC 27604 (919) 834-3476 FAX:(919) 834-3477
AUTHORIZED APPLIANCE SERVICECENTER
904 S. MARSHALL ST. WINSTON-SALEM, NC 27403 (336) 725-5396 FAX:(336) 721-1289
AUTHORIZED APPLIANCE SERVICECENTER
104 HINTON AVE. WILMINGTON, NC 28403 (910) 313-1250 FAX:(910) 313-6130
WHALEY FOODSERVICE
8334-K ARROWRIDGE BLVD CHARLOTTE, NC 28273 (704) 529-6242 FAX: (704) 529-1558 info@whaleyfoodservice.com
WHALEY FOODSERVICE REPAIRS
203-D CREEK RIDGE RD. GREENSBORO, NC 27406 (336) 333-2333 FAX: (336) 333-2533 info@whaleyfoodservice.com
WHALEY FOODSERVICE REPAIRS
335-105 SHERWEE DRIVE RALEIGH, NC 27603 (919) 779-2266 FAX: (919) 779-2224 info@whaleyfoodservice.com
WHALEY FOODSERVICE REPAIRS
6418-101 AMSTERDAM WAY WILMINGTON, NC 28405 (910) 791-0000 FAX: (910) 791-6662 info@whaleyfoodservice.com
NORTH DAKOTA
GCS SERVICE INC.
MINNEAPOLIS, MN (612) 546-4221 800-345-4221 FAX: (612) 546-4286
GENERAL PARTS, INC.
10 SOUTH 18TH STREET FARGO, ND 58103 (701) 235-4161 (800) 279-9987 (701) 235-0539 FAX
OHIO
CERTIFIED SERVICE CENTER
890 REDNA TERRACE CINCINNATI, OH 45215 (513) 772-6600 800-543-2060 FAX: (513) 612-6600 sbarasch@certifiedsc.com
CERTIFIED SERVICE CENTER
171J-K NORTH HAMILTON RD. COLUMBUS, OH 43213 (614) 751-3769 (866) 862-1252 FAX: (614) 751-5792 jadkins@certifiedsc.com
CERTIFIED SERVICE CENTER
6025 N. DIXIE DRIVE DAYTON, OH 45414 (937) 898-4040 (800) 257-2611 FAX: (937) 898-4177 dharvey@certifiedsc.com
COMMERCIAL PARTS & SVC. OF COLUMBUS
5033 TRANSAMERICA DRIVE COLUMBUS, OH 43228 (614) 221-0057 800-837-8327 FAX: (614) 221-3622
GCS SERVICE INC.
COLUMBUS, OH (614) 476-3225 800-282-5406 FAX: (614) 476-1196
ELECTRICAL APPLIANCE REPAIR SVC.
5805 VALLEY BELT ROAD CLEVELAND, OH 44131 (216) 459-8700 800-621-8259 FAX: (216) 459-8707 tomr@electapplrep.com
OKLAHOMA
HAGAR RESTAURANT EQMT.
1229 W MAIN STREET OKLAHOMA CITY, OK 73106 (405) 235-2184 800-445-1791 FAX: (405) 236-5592
OREGON
RON'S SERVICE
16364 SW 72ND AVE PORTLAND, OR 97224 (503) 624-0890 800-851-4118 FAX: (503) 684-6107 lrobinson@ronsservice.com
PENNSYLVANIA
A.I.S. COMMERCIAL PARTS & SERVICE
1816 WEST 26TH STREET ERIE, PA 16508 (814) 456-3732 800-332-3732 FAX: (814) 452-4843 aiserie@aol.com
ELMER SCHULTZ SVC.
540 NORTH 3RD STREET PHILADELPHIA, PA 19123 (215) 627-5400 FAX: (215) 627-5408 elmer2@erols.com
GCS SERVICE INC.
PHILADELPHIA, PA (215) 925-6217 800-441-9115 FAX: (215) 925-6208
GCS SERVICE INC.
HARRISBURG, PA (717) 564-3282 800-367-3225 FAX: (717) 564-9286
GCS SERVICE INC.
PITTSBURGH, PA (412) 787-1970 800-738-1221 FAX: (412) 787-5005
K & D PARTS AND SERVICE CO.
1833-41 N CAMERON STREET HARRISBURG, PA 17103 (717) 236-9039 800-932-0503 FAX: (717) 238-4367 kdparts-service@paonline.com
CLARK SERVICE & PARTS
306 AIRPORT DRIVE BOX 10 SMOKETOWN, PA 17576 (717) 392-5590 (717) 392-5735
Tempstar LT/NB/S/SDS Technical Manual 7610-011-86-35
Issued: 12-07-2007 Revised: N/A
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS
NEW YORK TO PENNSYLVANIA
92
Loading...