![](/html/07/077a/077abee78be7d2e7a66deee8045e421eede0d91a990dfdb74a2f0ea81c1429ce/bg1.png)
TempStar® HH/GPX
Models
TempStar® HH/GPX
Project
Item
Quantity
CSI Section 11400
Approval
Date
TempStar® HH/GPX
Standard Features
• Multi-cycle timer (Extra Heavy,
Heavy, Medium, Normal)
• Built-in pressure regulator and
gauge
• Extended 15 second high tempera-
ture rinse provides superior cover age and rapid drying
• 20-3/4" wideX 27" high (527 mm X
686 mm) opening accommodates
18" X 26" (457 mm X 660 mm) sheet
pans and 60 quart mixing bowls
• Auto-ll / auto-start
• Safety door switch
• External gas booster heater
- Capable of minimum 70˚F (21˚C)
degree temperature rise
- Recirculates water through stain less steel coils in wash tank to
maintain 150˚F (66˚C) degree
minimum temperature
• Hi-limit thermostat and low water
protection
• Top mounted controls for ease of
installation
• Unique lower counter-rotating
wash arms and upper wash arm
provide optimum spray coverage
and superior cleaning action
• Unique split-door design for insta-
llations with low ceiling heights
• Large scrap tray
• Self-draining stainless steel pump
• Detergent/rinse additive signal
connection fuse box
• Delime/manual wash switch
• Adjustable bullet feet
• Uses standard 20” X 20”
(508 mm X 508 mm) racks
• Front dress panel
Mandatory Specs
Specify incoming water
temperature
Specify how far booster
will be placed from unit
Specify altitude for proper
booster size
Options
Water Hammer Arrestor
Flanged Feet
Drain Quench System
Scaltrol
False Panel
Safety Door Interlock
Accessories
36-Compartment Rack
4-1/8” tall (105 mm)
5-5/8” tall (143 mm)
7” tall (178 mm)
Combination Rack
Peg Rack
Sheet Pan Rack - for 18” X 26”
(457 mm X 660 mm) baking
pans
Specifications
Uses 1.36 gallons (5 liters) of 180˚F (82˚C)
water per rack
Total automatic normal cycle - 62 seconds
53 racks per hour normal cycle
2 hp wash pump motor
Single point connections for all utilities
SHIP PING AD DRESS
6209 North U.S. Hi ghway 25E
Gray , KY 40 734
MAILING ADDR ESS
P.O. Box 106 0
Barbourville , KY 40906
Built-in water pressure regulator and
pressure gauge
Field convertible from straight through
to corner and vice versa
Heavy duty stainless steel construction
Tel: 1-888-8 00-5672
Fax: 606-523 -1799
info@jackson msc.com
www.jacksonm sc.com
![](/html/07/077a/077abee78be7d2e7a66deee8045e421eede0d91a990dfdb74a2f0ea81c1429ce/bg2.png)
TempStar® HH/GPX
25 [637mm]
17 [432mm]
C
E
1 [25mm]
DRAIN
HEIGHT
11-3/4”
(298 mm)
4 [102mm]
C
1
25
[642mm]
4
32 [813mm]
MODEL NO.
TempStar® HH/GPX
4 [102mm]
3
86
[2202mm]
4
73 [1856mm]
3 [77mm]
3
7
[194mm]
4
MACHINE DIMENSIONS
HEIGHT WIDTH DEPTH WEIGHT CLASS CUBE HEIGHT WIDTH DEPTH
76-3/4”
(1949 mm)
25-1/4”
(641 mm)
25-1/4”
(641 mm)
DIMENSION REQUIREMENTS
Minimum Ceiling Height (Recommended)
Wall Clearance (Minimum)
Standard Table Height
Inside Clearance
88” (2 meters)
4” (102 mm)
34” (864 mm)
27” (686 mm)
OPERATING CAPACITY
Racks per Hour
OPERATING CYCLE (seconds)
Normal 45 15 2 62
Medium 103 15 2 120
Heavy 163 15 2 180
Extra Heavy 283 15 2 300
Normal53Medium28Heavy19Extra Heavy
Wash Rinse
Dwell Total Cycle
11
OPERATING TEMPERATURES
Wash (Minimum) 150˚F (66 °C)
Rinse (Minimum) 180˚F (82 °C)
APPROXIMATE TOTAL LOAD AMPS
AMPS
115V/60HZ/1PH
208V/60HZ/1PH
208V/60HZ/3PH 13
230V/60HZ/1PH 13
230V/60HZ/3PH 13
25
13
1
25
[639mm]
4
3 [79mm]
C
D
A
1
15
[387mm]
4
B
18 [456mm]
E
3
11
[298mm]
4
A
11
10
3
[298mm]
4
1
3
[92mm]
2
3
[274mm]
4
LEGEND
A - DRAIN 1 1/2” NPT
B - WATER INLET 1/2” NPT
C - ELECTRICAL CONNECTION
D - OUTLET TO BOOSTER
HEATER 3/4” NPT
E - INLET FROM BOOSTER
HEATER 3/4” NPT
All vertical dimensions are +/- 1/2"
due to adjustable bullet feet.
27 [687mm]
34 [861mm]
16
3
[426mm]
4
5 [126mm]
SHIPPING INFORMATION
420 lbs
(191 kg)
92.5
74.9
cu. ft.
79”
(2007 mm)
33”
(838 mm)
GAS REQUIREMENTS
Maximum Minimum
Natural Gas (Inches-water column) 10.5 (267 mm) 5.0 (127 mm)
LP Propane Gas (Inches-water column) 13.0 (330 mm) 11.0 (292 mm)
Gas Booster Capacity (BTU)
Input 105,000
Output 84,800
WATER REQUIREMENTS
Inlet Tempterature
40˚F / (4˚C) Rise 140˚F (60˚C)
70˚F / (21˚C) Rise 110˚F (43˚C)
Gallons per Hour 72.1 gal (273 L)
Waterline Size IPS (Minimum-inches) 3/4”
Drainline Size IPS (Minimum-Inches) 1-1/2”
Flow Pressure (PSI) 15-25
Wash Tank Capacity 8 gal (30 L )
Booster Tank Capacity 3 gal (11 L )
Pump Capacity (GPM) 73 gal (276 L )
WASH PUMP MOTOR
Wash Pump Motor 2 hp
HOW TO SPECIFY:
TempStar® HH/GPX
34 [866mm]
49”
(1245 mm)
SHIP PING AD DRESS
6209 North U.S. Hi ghway 25E
Gray , KY 40 734
MAILING ADDR ESS
P.O. Box 106 0
Barbourville , KY 40906
Tel: 1-888-8 00-5672
Fax: 606-523 -1799
info@jackson msc.com
www.jacksonm sc.com
07610-002-66 -62 (02/10)