IRIS Care Pendant User Manual

CARE PENDANT
Iris Care Pendant provides peace of mind for family members by alerting you when those who carry it need assistance.
lowe’s item #
690403
model
3455-L
1.75”
45 mm
0.60”
15 mm
2.0”
51 mm
battery (cr-2450)led
lock/unlock indicator
side backfront
key features
Superior Output Power & Over-the-Air Updates:
The Iris Care Pendant supports over-the-air updates providing for seamless upgrades and feature additions without the need for any user interaction.
While the pendant can communicate with the hub up to 130 ft. away, it is im­portant to test coverage, as results may vary based on the layout of your home.
First, configure the notification list, then press the button at the furthermost areas of the home.
The device is out of range if you do not receive a notification for each time you press the button. If this is the case consider adding Smart Plugs, which serve as range extenders.
getting started
Step 1
Step 2
Step 3
In the Iris by Lowe’s App, select the + sign, then “Devices.”
Insert the battery so the plus sign is facing you.
Close the battery door and tighten it using either your fingernails or a coin. The hub will beep when pairing is complete.
use case
• Send notifications during medical emergencies
• Peace of mind for extended independent living
• Alert contacts when device leaves the home
compatibility
The Lowe’s IRIS Care Pendant is fully ZigBee HA
1.2 certified and will work
with other open ZigBee HA
1.2-certified systems.
user guide: iris care pendant (3455-l) © 2015 lowe’s iris. all rights reserved.1 / 2
CARE PENDANT
lowe’s item #
690403
model
3455-L
approvals (english)
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference and (2) This device must accept any interference received, including interference that may cause undesired operation.
Conforms to FCC Part 15B Contains FCC ID: T3L-SS011 IC: 12192A-SS011
Industry Canada licence-exempt RSS Standards. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interfer­ence that may cause undesired operation.
Under Industry Canada regulations, this radio trans mitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equiv­alent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. This equipment is in direct contact with the body of the user under normal operating conditions. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Changes or modifications not expressly approved by Lowes, Inc. could void the user’s authority to operate the equipment.
For more information, visit IrisByLowes.com.
approvals (franÇais)
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1) l’appareil ne doit pas produire de brouillage, et (2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utili­sateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.
troubleshooting
Step 1
Using a coin, twist the rear battery door counterclockwise to detach. Remove battery and replace with a new CR-2450 battery. Reassemble and test operation.
Step 2
Remove battery. While holding down the button, reinsert battery and continue to hold for two seconds, then release the button. This will factory reset the device. Repeat the “Getting Started” steps to rejoin the ZigBee network.
for additional help
Check out support.IrisByLowes. com or call 1-855-469-IRIS (4747).
technical specifications
Power
Rated: 3V Battery: CR-2450 (1x) Battery Life: Up to 2 years
Environmental
Operating Temperature: 0° to 40°C
Shipping/Storage
Temperature: -20° to 50°C Humidity Range: 0 to 90% RH. (non-condensing)
Approvals
Wireless RF Protocol
Protocol: ZigBee HA 1.2 TX Strength: +3 dBm RF Channels: 16 Range: 130 ft. (40m) LOS
Pour plus d’informations, visitez IrisByLowes.com.
user guide: iris care pendant (3455-l) 2015 lowe’s iris. all rights reserved.2 / 2