ZC6.qxd 6/6/03 4:03 pm Page 1
Configurable Power Supply
|
|
|
|
600 Watts |
XPiQ inc. |
||
ZC Series |
Intelligent Design Quality Product |
||
|
|
||
|
|
|
|
• |
Meets EN61000-3-2, -3 |
|
|
• |
|
||
|
|
Up to 5 Outputs Plus 5V Standby |
|
|
|
• |
|
|
|
Low Voltage Outputs Down to 1.8V |
|
|
|
• |
|
|
|
Hot Swap or Chassis Mount |
|
|
|
• |
|
|
|
Oring Diodes On All Outputs |
|
|
|
(Hot Swap Modules) |
|
|
|
• |
|
|
|
1U, 19” Rack Mount for 2 units |
|
|
|
• |
|
|
|
International Safety Approvals with CE (LVD) |
|
|
|
|
|
Specification
Input
AC Input Voltage |
• |
85-264 VAC |
Input Frequency |
• |
47-63 Hz |
DC Input Voltage |
• 48 VDC nominal (optional) |
|
Power Factor |
• |
0.99 |
Harmonic Current |
• |
Meets EN61000-3-2 |
Inrush Current |
• Limited to 30A peak |
|
Input Protection |
• |
Internal 15A fuse |
Output
Output Voltage |
• 1.8 VDC to 12 VDC |
|
Output Power |
• |
600W |
Output Voltage Adj |
• ±5% min, See models chart |
|
Minimum Load |
• 0 minimum load for all outputs |
|
Line/Load Regulation |
• ±2% for V1, V2 and V3, ±3% |
|
|
|
for V4 and V5 |
Ripple & Noise |
• >2.5V output: 50mV or 1% whichever |
|
|
|
is greater <=2.5V output: |
|
|
2% maximum |
Transient Response |
• 4% max deviation, 300 µs recovery |
|
|
|
time for a 25% load change |
Temperature Co-eff. |
• |
0.02%/°C |
Hold Up Time |
• |
20ms minimum |
Remote Sense |
• Up to 0.25 V compensation on V1, V2 |
|
|
|
and V3 |
Overvoltage |
• V1, V2 and V3 only, recycle |
|
Protection |
|
input to reset |
Overcurrent |
• Standard with auto recovery |
|
Protection |
|
|
Overtemperature |
• Logic high signal for overtemp |
|
Protection |
|
conditions |
Current Sharing |
• ±10% for V1, V2 and V3 with |
|
|
|
“H” option |
General
Efficiency |
• 75% typical at full load |
|
Power Density |
• |
6.8 W/in3 |
MTBF |
• 200,000 hrs per Bellcore |
|
Isolation Voltage |
• 3000 VAC Input to Output |
|
|
|
1500 VAC Input to Ground |
|
|
500 VAC Output to Ground |
Signals |
• PSU Enable, AC Fail, DC OK, |
|
|
|
Global Inhibit, overtemp |
LED Indicators |
• |
2 status indicators |
Size |
• 5.0” x 11.0” x 1.6”. |
|
Weight |
• 3.3 lbs (1.5 kgs.) |
Environmental
Operating |
• |
0°C to 70°C, Full power to 50°C |
Temperature |
|
derate from 50°C to 70°C |
|
|
at 2.5%/°C |
Cooling |
• |
3 Internal ball bearing fans |
Humidity |
• |
<95% RH, non-condensing |
Storage Temperature |
• |
-40°C to +85°C |
Safety and EMC
Safety Approvals |
• UL1950, CSA C22.2 No 950 per cUL, |
|
EN60950 CE Mark LVD |
EMI/EMC |
• EN61000-3-2, -3, EN55022 and FCC |
|
20780 part 15J Class B conducted |
|
with rack, Class A stand alone |
Immunity & Surge |
• Meets EN61000-4-4, -5 |
• |
|
PH: 508 |
429.9883 |
• |
||
|
||||||
|
||||||
|
|
|
|
FAX: 800 |
226.2100 |
|
|
www.XPiQ.com |
|
|
Email: sales@xpiq.com |
|
|
|
|
|
Holliston, MA 01746 USA |
|
||
|
|
|
|
ZC6.qxd 6/6/03 4:03 pm Page 2
|
|
ORDERING CODES |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ZC |
||||||
|
|
CODE |
V1 |
|
V2 |
|
|
V3 |
|
CODE |
|
|
|
V4 |
|
CODE |
|
V5 |
||||||||||
|
|
01 |
|
1.8 V @ 70 A |
|
2.5 V @ 50 A |
|
12 |
V @ 10A |
|
|
PA |
|
+3.3 V @ 3 A |
|
PD |
|
+1.8 V @ 3 A |
||||||||||
|
|
02 |
|
1.8 V @ 70 A |
|
3.3 V @ 50 A |
|
12 |
V @ 10A |
|
|
NA |
|
|
-3.3 V @ 3 A |
|
ND |
|
-1.8 V @ 3 A |
|||||||||
|
|
03 |
|
1.8 V @ 70 A |
|
5.0 V @ 50 A |
|
12 |
V @ 10A |
|
|
PB |
|
+5.0 V @ 3 A |
|
PE |
|
+2.5 V @ 3 A |
||||||||||
|
|
04 |
|
2.5 V @ 100 A |
|
- |
|
|
12 |
V @ 10A |
|
|
NB |
|
|
-5.0 V @ 3 A |
|
NE |
|
-2.5 V @ 3 A |
||||||||
|
|
05 |
|
2.5 V @ 70 A |
|
3.3 V @ 50 A |
|
12 |
V @ 10A |
|
|
|
|
PC |
|
+12.0 V @ 3 A |
|
PF |
|
+3.3 V @ 3 A |
||||||||
|
|
06 |
|
2.5 V @ 70 A |
|
5.0 V @ 50 A |
|
12 |
V @ 10A |
|
|
|
|
|
NC |
|
-12.0 V @ 3 A |
|
NF |
|
-3.3 V @ 3 A |
|||||||
|
|
07 |
|
3.3 V @ 100 A |
|
- |
|
|
12 |
V @ 10A |
|
- |
|
|
- |
|
PG |
|
+5.0 V @ 3 A |
|||||||||
|
|
08 |
|
3.3 V @ 70 A |
|
2.5 V @ 50 A |
|
12 |
V @ 10A |
|
|
|
- |
|
|
- |
|
NG |
|
-5.0 V @ 3 A |
||||||||
|
|
09 |
|
3.3 V @ 70 A |
|
5.0 V @ 50 A |
|
12 |
V @ 10A |
|
|
|
- |
|
|
- |
|
PH |
|
+5.2 V @ 3 A |
||||||||
|
|
10 |
|
5.0 V @ 100 A |
|
- |
|
|
12 |
V @ 10A |
|
- |
|
|
- |
|
NH |
|
-5.2 V @ 3 A |
|||||||||
|
|
11 |
|
5.0 V @ 70 A |
|
2.5 V @ 50 A |
|
12 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
||||||||||
|
|
12 |
|
5.0 V @ 70 A |
|
3.3 V @ 50 A |
|
12 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||
|
|
13 |
|
1.8 V @ 70 A |
|
2.5 V @ 50 A |
|
5 |
V @ 10A |
|
|
XX |
|
|
|
N/C |
|
PD |
|
+1.8 V @ 3 A |
||||||||
|
|
14 |
|
1.8 V @ 70 A |
|
3.3 V @ 50 A |
|
5 |
V @ 10A |
|
|
- |
|
|
- |
|
ND |
|
-1.8 V @ 3 A |
|||||||||
|
|
15 |
|
2.5 V @ 100 A |
|
|
|
|
5 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
|||||||||
|
|
16 |
|
2.5 V @ 50 A |
|
3.3 V @ 50 A |
|
5 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
||||||||||
|
|
17 |
|
3.3 V @ 100 A |
|
|
|
|
5 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
|||||||||
|
|
18 |
|
2.5 V @ 50 A |
|
2.5 V @ 50 A |
|
5 |
V @ 10A |
|
- |
|
|
- |
|
- |
|
- |
||||||||||
|
Notes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||
|
|
1. For module codes 13 to 18, V4 may have an unregulated output but this output is not useable. XX is the only option code available for |
||||||||||||||||||||||||||
|
|
V4 and only ±1.8V output is available for V5. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||
|
|
2. V4 is user adjustable from 2.8 VDC to 14.75 VDC codes define setpoint at factory. |
|
|
|
|
|
|
|
|||||||||||||||||||
• |
3. V5 is user adjustable from 1.7 VDC to 8.12 VDC codes define setpoint at factory. |
|
|
|
|
|
|
|
||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
PART NUMBER ORDERING SCHEME |
|
|
|
|
|
|
|
|
|
|
||||||||||||||||
|
|
Series |
|
AC or DC |
|
Hotswap or |
|
V1-V3 |
|
Polarity |
|
V4 Output |
|
Polarity of |
V5 Output |
|
Option |
|||||||||||
|
|
|
|
Input |
|
|
Chassis |
|
Code |
|
of V4 |
|
Code |
|
|
V5 |
Code |
|
Code |
|||||||||
|
|
ZC |
|
A6=AC |
|
H=Hotswap |
|
01 to 18 |
|
P = Positive |
|
A to C |
|
|
P = Positive |
D to H |
L = Low Leakage |
|||||||||||
|
|
|
|
D6=DC |
|
C=Chassis |
|
|
|
|
N = Negative |
|
|
|
N = Negative |
|
|
I = I2C Module |
||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
M = Low Leakage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
&12C |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Example: ZCA6H06NCNG is AC input, Hotswap chassis with V1 = 2.5V/70A, V2 = 5V/50A, V3 = 12V/10A, V4 = -12V/3A, V5 = -5V/3A.
Mechanical Details
* Note:
Vertical blackplane mounting may not allow for sufficient airflow. Horizontal backplane, or additional spacing with a vertical backplane is recommended.
www.XPiQ.com
PH: 508 429.9883