Intex ECO20220, ECO20230, ECO15220, ECO15230 Owner's Manual

261A
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
IMPORTANT
SAFETY RULES
Read, understand, and follow
installing and using this product.
Don’t forget to try these other fine Intex products: pools, pool accessories, inflatable pools and in-home toys, airbeds and boats available at fine retailers or visit our website. Due to a policy of continuous product improvement, Intex reserves the right to change specifications and appearance, which may result in updates to the instruction manual without notice.
OWNER’S MANUAL
©2014 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Trading Ltd.
- Intex Recreation Corp. All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle
Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.
®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen Ländern der Welt in Lizenz von/Intex Marketing Ltd. to/à/a/an Intex Trading Ltd., Intex Development Co. Ltd., G.P.O
Box 28829, Hong Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801 • Distributed in the European Union by/Distribué dans l’Union Européenne par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union
durch/Intex Trading B.V., Venneveld 9, 4705 RR Roosendaal – The Netherlands www.intexcorp.com
For illustrative purposes only.
Model ECO15220 220
230V~,
Model ECO15230 230
240V~, 6 m3 ; Model ECO20220 220 – 230V~, Model ECO20230 230 – 240V~, 8 m
3
261-*A*-R0-1508
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 2
Warnings
.........................................................................................
3
Parts References
...........................................................................
4-5
Setup Instructions
........................................................................
6-13
Product Specifications
..................................................................
8
Operating Instructions
.................................................................
14-18
LED Code Chart
.............................................................................
19
Salt & Pool Water Volumes
..........................................................
20
Intex Pools Salt Table
....................................................................
21
Intex Pools Cyanuric Acid Table............................................
......
22
Intex Pools Operating Time Table
...............................................
23
Non-Intex Pools Salt Table
............................................................
24
Non-Intex Pools Cyanuric Acid Table.......................................... 24
Non-Intex Pools Operating Time Table
........................................
24
Maintenance
....................................................................................
25-29
Long Term Storage
........................................................................
29
Troubleshooting Guide
.................................................................
30-32
Common Pool Problems
...............................................................
33
General Aquatic Safety
.................................................................
33
Limited Warranty
...........................................................................
34
TABLE OF CONTENTS
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 3
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
• To reduce the risk of injury, do not permit children to use this product. Always supervise children and those
with disabilities.
• Children must stay away from this product and electrical cord(s).
• Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children
without supervision.
• This appliance can be used by children aged from 8 years and above and persons with reduced physical,
sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Assembly and disassembly by adults only.
• The pump must be supplied through a residual current device(RCD) having a rated residual operating current
not exceeding 30mA.
• Always unplug this product from the electrical outlet before removing, cleaning, servicing or making any
adjustment to the product.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers, hedge
trimmers and other equipment.
• If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or converter plugs to
connect unit to electric supply; provide a properly located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when your hands are wet.
• Keep this product more than 2m away from the pool.
• Keep this product more than 3.5m away from the pool (for France only).
• Keep the plug of this product more than 3.5m away from the pool.
• Position this product away from the pool, so as to prevent children from climbing on it and accessing the pool.
The pump must not be used when people are in the water.
• This product is for use with storable pools only. Do not use with permanently installed pools. A storable pool
is constructed so that it may be readily disassembled for storage and reassembled to its original configuration.
• To reduce the risk of entrapment hazard, never enter the pool if suction strainer component is loose, broken, cracked, damaged or missing. Replace loose, broken, damaged, cracked or missing suction strainer
components immediately.
• Never play or swim near suction fittings. Your body or hair may be trapped causing permanent injury or
drowning.
• To prevent equipment damage and risk of injury, always turn pump off before changing the filter control valve
position.
• Never operate this product above the maximum working pressure stated on the filter tank.
• Hazardous Pressure. Improper tank valve cover assembly could cause the valve cover to blow off and cause serious injury, property damage or death.
• This product is intended to be used only for the purposes described in the manual!
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS INJURY OR DEATH.
These product warnings, instructions and safety rules provided with the product represent some common risks of water recreation devices and do not cover all instances of risk and danger. Please use common sense and
good judgement when enjoying any water activity.
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 4
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
" * ": Optional. NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
28
29
30
31
32
33
34
28
29
30 31
32
33
28
29
30
35
36
37
28
29
30
35
36
38
*
*
*
*
1
5
9
10
11
21
2
13
20
19
3
6
7
4
12
15
16
17
18
8
22
23
24
25
26
27
40
18
14
46
47
48
41
42
45
43
44
39
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 5
" * ": Optional.
When ordering parts, be sure to quote the model number and part numbers.
PARTS REFERENCE (continued)
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
REF. NO. DESCRIPTION QTY.
SPARE PART NO.
ECO20220/ECO20230 ECO15220/ECO15230
1 PRESSURE GAUGE 1 11224 11411 2 6-WAY VALVE SET 1 11496 11378 3 DRAIN OUTLET COVER 1 11131 11131 4 TANK O-RING 1 11379 11379 5 SCREW 2 11381 11381 6 CLAMP 1 11380 11380 7 SAND SHIELD 1 11382 11382 8 CENTER PIPE HUB 1 11814 11813
9 DRAIN VALVE CAP 1 11456 11456 10 DRAIN VALVE O-RING 1 11385 11385 11 LATERAL 10 11384 11384 12 HOSE WITH NUTS 2 11010 11010 13 SAND FILTER INTERCONNECTING HOSE 1 11536 11390 14 LEAF TRAP NUT 1 11479 11479 15 LEAF TRAP O-RING 1 11232 11232 16 BASKET 1 11260 11260 17 FILTER HOUSING NUT 1 11261 11261 18 L-SHAPE O-RING 4 11228 11228 19 SEDIMENT RELEASE VALVE 1 10460 10460 20 VALVE O-RING 1 10264 10264 21 FLOW SENSOR 1 11460 11460 22 ELECTROLYTIC CELL 1 11372 11372 23 TITANIUM ELECTRODE 1 11374 11389 24 E.C.O. ELECTRODE 1 11905 11900 25 PRE-FILTER ASSEMBLY 1 11371
11371 26 PUMP MOTOR & CONTROL 1 11914/11914BS 11912/11912BS 27 L-SHAPE O-RING 1 11439 11439
28*
PLUNGER VALVE (HOSE O-RING & STEP WASHER INCLUDED)
2 10747 10747 29* HOSE O-RING 2 10262 10262 30* STEP WASHER 2 10745 10745 31* STRAINER NUT 2 10256 10256 32* FLAT STRAINER RUBBER WASHER 2 10255 10255 33*
THREADED STRAINER CONNECTOR
2 11235 11235 34* ADJUSTABLE POOL INLET NOZZLE 1 11074 11074 35* ADAPTOR B 2 10722 10722 36* STRAINER CONNECTOR 2 11070 11070 37* POOL INLET NOZZLE 1 11071 11071 38* STRAINER GRID 1 11072 11072
39 TEST STRIPS 1 19635 19635 40 LEAF TRAP COVER 1 11480 11480 41 ELECTROLYTIC CELL NUT 1 11432 11432 42 TITANIUM ELECTRODE O-RING 1 11585 11585 43 CELL HOUSING 1 11915 11915 44 SAND FILTER PUMP MOTOR INLET O-RING 2 11457 11457 45 ELECTROLYTIC CELL NUT 1 11582 11582 46 SAND FILTER PUMP AND COMBO TANK 1 11803 11802 47 SAND FILTER PUMP TANK BASE 1 11801 11800 48 O-RING ON TITANIUM PLATES 1 11515 11515
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 6
The strainer grid prevents large objects from jamming and/or damaging the filter pump. If your pool has an inflatable top ring, install the strainer, nozzle and plunger valve before inflating the pool liner top ring. The part numbers here onward refer to the parts depicted in the Parts List section of this manual. To install, do the following:
1.
In a counter-clockwise motion unscrew plunger valve
union from the threaded strainer connector
(33) (see
drawing 1).
Be careful not to lose the step rubber
washer
(30). Place the plunger valve on the ground in
a safe place.
2.
In a counter-clockwise motion unscrew the strainer nut
(31) from the threaded connector (33). Leave the flat
washer
(32) on the connector (33).
3.
Install the strainer and plunger valve at the lower
position of pool outlet (marked "+").
From the inside of
the pool liner insert the connector
(33) into one of the
pre-cut holes with the washer remaining on the connector to be placed against the inside of the liner wall.
4.
Before assembly, lubricate the threads with a petroleum
jelly. With the flat side of the strainer nut
(31) facing
the outside wall of the liner in a clockwise motion screw the strainer nut
(31) back onto the threaded connector
(33) (see drawing 2).
5.
Finger tighten the strainer nut (31) onto the threaded
connector
(33).
6.
Grasp the plunger valve assembly. Make sure the step
washer
(30) is in place.
7.
In a clockwise motion screw the plunger valve union back onto the threaded connector (33) (see drawing 3).
8.
In a clockwise motion turn the plunger valve handle to
close position. Ensure the plunger valve is securely
closed. This will prevent water from flowing out during filling of the pool
(see drawings 4).
POOL OUTLET - STRAINER & PLUNGER VALVE SETUP (optional)
2
32
33
INSIDE
LINER WALL
31
3
1
2
1
2
1
30
4
INSIDE
LINER WALL
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 7
POOL INLET - NOZZLE & PLUNGER VALVE SETUP (optional)
1.
In a counter-clockwise motion unscrew plunger valve
union from the threaded strainer connector
(33) (see
drawing 5).
Be careful not to lose the step rubber
washer
(30). Place the plunger valve on the ground in
a safe place.
2.
In a counter-clockwise motion unscrew the strainer
nut
(31) from the threaded connector (33). Leave the
flat washer
(32) on the connector (33).
3.
Install the nozzle and plunger valve at the upper
position of pool inlet.
From the inside of the pool liner
insert the connector
(33) into one of the pre-cut holes
with the washer remaining on the connector to be placed against the inside of the liner wall.
4.
Before assembly, lubricate the threads with a
petroleum jelly. With the flat side of the strainer nut
(31)
facing the outside wall of the liner in a clockwise
motion screw the strainer nut
(31) back onto the
threaded connector
(33) (see drawing 6).
5.
Finger tighten the adjustable pool inlet nozzle (34) and
the strainer nut
(31) onto the threaded connector (33).
6.
Grasp the plunger valve assembly. Make sure the step
washer
(30) is in place.
7.
In a clockwise motion screw the plunger valve union back onto the threaded connector (33) (see
drawing 7)
.
8.
In a clockwise motion turn the plunger valve handle
to close position. Ensure the plunger valve is securely
closed. This will prevent water from flowing out during filling of the pool
(see drawing 8).
9
. Adjust the direction of nozzle head pointing away from
the pool outlet for a better circulation result
(see
drawing 9)
.
10.
The pool liner is now ready to fill with water. Consult
the above-ground-pool owner’s manual for filling
instructions.
9
5
2
1
7
1
2
8
INSIDE
LINER WALL
6
32
33 34
INSIDE
LINER WALL
31
WATER
FLOW
Pool
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 8
PRODUCT SPECIFICATIONS
SETUP INSTRUCTIONS
The sand filter removes suspended particles and sanitize your pool. Pool chemistry is a specialized area and you should consult your local pool service specialist for details.
TOOLS REQUIRED: One (1) Phillips screwdriver Pump location and mounting:
• Thesystemmustbeinstalledonasolidlevelandvibration-freebase.
• Providealocationprotectedfromtheweather,moisture,
flooding and freezing temperature.
• Provideadequateaccess,spaceandlightingforroutine
maintenance.
• Pumpmotorrequiresfreecirculationofairforcooling.
Do not install the pump in a damp or non-ventilated location.
A team of 2 or more people is recommended for setting up this product.
Motor pre-filtering assembly setup:
1.
Remove the sand filter and its accessories from the
packaging carefully and inspect for any visible damage.
2.
In a counter-clockwise motion unscrew the leaf trap cover
(14) from the pre-filter housing. Take out the basket (16) and
filter housing nut
(17) (see drawing 10).
3.
Connect the pre-filter housing to the motor water inlet.
Note: Align the connector in the pre-filter housing with the
water inlet on the motor
(see drawing 11).
10
11
14
17
16
40
Model: ECO20220/ECO20230 ECO15220/ECO15230 Wattage: 770 W 470 W
Ideal Salt Level: 3000 ppm (parts per million) 3000 ppm Maximum Sanitizer Output/hour: 11 grams/hour 7 grams/hour E.C.O. Cell Output Current: 800mA 500mA
Maximum working pressure:
2 bar (30 psi) 2 bar (30 psi)
Effective filtering area: 0.13 m
2
(1.44 ft2) 0.1 m2 (1.1 ft2)
Maximum Flow Rate: 8140 liters/hour
(2150 gallons/hour)
6055 liters/hour
(1600 gallons/hour)
Recommended filtering media quantity:
No. 20 silica sand 45 Kg (100 Lbs) or glass sand 32 Kg (70 Lbs).
No. 20 silica sand 25 Kg (55 Lbs) or glass sand 18 Kg (40 Lbs).
Recommended filtering
media (Not included) :
No. 20 silica sand or glass sand. Particle size range 0.45 to 0.85 mm (0.018 to 0.033 inches). Uniformity Coefficient less than 1.75.
Limited Warranty: see “Limited Warranty”
HOW THE ELECTROCATALYTIC OXIDATION WORKS
The Electrocatalytic Oxidation (E.C.O.) is an Advanced Oxidation Processes (AOPs). When direct current is applied to the electrocatalytic oxidation electrodes, water will be discharged to generate “hydroxyl radicals”. The hydroxyl radical is a powerful oxidant, which oxidizes organic contaminants, and destroys bacteria and algae. Hydroxyl radicals in combination with free
available chlorine provide the strongest and safest pool water sanitation.
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 9
4.
In a clockwise motion screw filter housing nut (17) onto the motor water inlet (See
drawings 12.1 & 12.2)
.
5.
Replace the basket (16) and leaf trap cover (14) back to the pre-filter housing (See
drawings 13.1 & 13.2)
.
SETUP INSTRUCTIONS (continued)
13.2
14.1
14.2
14.3
12.2
12.1
17
17
13.1
16
14
40
115 mm
Sand tank installation:
1.
Place the tank support base at the selected location.
2.
Place the tank on the tank support base (See drawing 14.1).
3. Connect the motor pre-filtering assembly unit to the tank support base
(See drawing 14.2)
.
NOTE: Ensure the pre-filter housing water inlet hose connection is facing towards the pool.
IMPORTANT: Some countries, especially in the European community, require the product to be secured to the ground or to a base in a permanent upright position. Check your local authorities to determine if there is a regulation in your area regarding above-the-ground swimming pool filter-pumps. If yes, then the product can be mounted to a platform using the two holes located in the base. See drawing 14.3. The product can be mounted on a cement base or onto a wooden platform to prevent accidental falling over.
• Themountingholesare6.4mmindiameterandspaced115mmapart.  • Usetwoboltsandlocknutswithamaximumof6.4mmindiameter.
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 10
SETUP INSTRUCTIONS (continued)
Sand loading:
IMPORTANT: Use No. 20 silica sand or glass sand with particle size range 0.45 to 0.85 mm (0.018 to 0.033 inches) and a Uniformity Coefficient less than 1.75.
NOTE: Before loading the tank with sand, ensure the center pipe hub assembly is securely in place at the bottom of the tank, and vertically centered inside the tank.
1.
Place the sand shield
(7) over the top of the center pipe. Pour the sand into the tank at a
slow rate.
(see drawing 15).
2.
Fill the tank approximately half way, remove the sand shield (7). (see drawing 16).
3.
Evenly distribute the sand inside the tank, then fill the tank with some water to provide a
cushioning effect when the remaining sand is poured in. This prevents the center pipe hub
(8)
from excessive shock
(see drawing 17). Place the sand shield (7) back and continue to pour
the sand into the tank.
4.
Sand shall be filled between the “MAX” and “MIN” marked gauge on the center pipe. Evenly
spread and level out the sand by hand
(see drawings 17 & 18).
5.
Remove the sand shield
(7).
6.
Wash away all sand around the top edge of the tank.
15
7
16
7
MAX
MIN
MAX
MIN
18
8
MAX
MIN
17
8
261A
SAVE THESE INSTRUCTIONS
(261IO) Sand Filter Pump & Saltwater System with Electrocatalysis Oxidation (14” & 16”) ENGLISH 7.5” X 10.3” PANTONE 295U 08/04/2014
English
Page 11
6-way valve installation:
1.
Lower the 6-way valve over the tank slowly, and ensure the bypass pipe protruding
underneath the 6-way valve fits securely into the center pipe hub
(8) top opening (see
drawing 19)
.
IMPORTANT: There are three hose connection ports on the 6-way valve, ensure the outlet connection (from filter to the pool) on the valve is facing towards the pool, and the inlet connection (from motor to valve) is aligned with the motor outlet (see drawing 20).
2.
Remove the clamp bolt, and install the clamp around the tank and 6-way valve flanges, then
replace the clamp bolt and use a phillips screwdriver (not included) to tighten it.
(see
drawing 21)
.
SETUP INSTRUCTIONS (continued)
WARNING
Improper tank valve and clamp assembly could cause the valve and clamp to blow off and cause serious injury, property damage or death.
3.
Connect the sand filter interconnecting hose (13) between the 6-way valve inlet and motor
outlet,
and insert the electrolytic cell (22) into the 6-way valve outlet. Hand tighten them
securely (
see drawings 22 and 23).
22
23
4.
Screw and tighten the flow sensor (21) to the electrolytic cell (22), then plug in the
electrolytic cell line cord and tighten the nut (
see drawings 24 and 25).
13
22
6
19
20
WATER
INLET
WATER
OUTLET
21
8
24
25
21
22
Loading...