(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
IMPORTANT
SAFETY RULES
Read, understand, and follow
all instructions carefully before
installing and using this product.
Krystal Clear™
Model 635T
Filter Pump
English
English
107
107
For illustrative purposes only.
Don’t forget to try these other fine Intex products: pools, pool
accessories, inflatable pools and in-home toys, airbeds and boats
available at fine retailers or visit our website.
Due to a policy of continuous product improvement, Intex reserves
the right to change specifications and appearance, which may
result in updates to the instruction manual without notice.
OWNER’S MANUAL
IMPORTANT!
DO NOT RETURN PRODUCT TO STORE
To purchase parts and accessories or to obtain non-technical assistance, Visit
For technical assistance and missing parts call us toll-free (for U.S. and Canadian Residents):
www.intexcorp.com
1-800-234-6839
Monday through Friday, 8:30am to 5:00pm Pacific Time
107-***-R0-1406
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
IMPORTANT SAFETY RULES
Read, Understand and Follow All Instructions Carefully Before Installing and Using this Product.
READ AND FOLLOW ALL INSTRUCTIONS
WARNING
• To reduce the risk of injury, do not permit children to use this product. Always supervise
children and those with disabilities.
• Children must stay away from this product and electrical cord(s).
• Assembly and disassembly by adults only.
• Risk of electric shock. Connect only to a grounding type receptacle, this product is provided
with a ground-fault circuit interrupter. If replacement of the plug or cord is needed, use only
identical replacement parts.
• Always unplug this product from the electrical outlet before removing, cleaning, servicing or
making any adjustment to the product.
• The unit is provided with a ground-fault circuit interrupter (GFCI). To test the GFCI, push the
test button. The GFCI should interrupt power. Push the reset button, power should be restored.
If the GFCI fails to operate in this manner. The GFCI is defective. If the GFCI interrupts power
to the pump without the test button being pushed, a ground current is flowing, indicating the
possibility of an electric shock. Do not use this pump. Disconnect the pump and have the
problem corrected by a qualified service representative before using.
• Do not bury the electrical cord. Locate the cord where it will not be damaged by lawn mowers,
hedge trimmers and other equipment.
• To reduce the risk of electric shock, replace damaged cord immediately. Use a qualified
electrician to replace the cord.
• To reduce the risk of electric shock, do not use extension cords, timers, plug adaptors or
converter plugs to connect unit to electric supply; provide a properly located outlet.
• Do not attempt to plug in or unplug this product while standing in water or when your hands
are wet.
• Do not use an appliance leakage current interrupter (ALCI) in place of a GFCI since the ALCI
will not protect people.
• Position this product away from the pool, so as to prevent children from climbing on it and
accessing the pool.
• Do not operate this product when the pool is occupied.
• This product is intended to be used only for the purposes described in the manual!
107
FAILURE TO FOLLOW THESE WARNINGS MAY RESULT IN PROPERTY
DAMAGE, ELECTRIC SHOCK, ENTANGLEMENT OR OTHER SERIOUS
INJURY OR DEATH.
CAUTION
This product is for use with storable pools only. Do not use with permanently-installed
pools. A storable pool is constructed so that it is capable of being readily disassembled
for storage and reassembled to its original integrity. A permanently-installed pool is
constructed in or on the ground or in a building such that it cannot be readily
disassembled for storage.
These product warnings, instructions and safety rules provided with the product represent some
common risks of water recreation devices and do not cover all instances of risk and danger.
Please use common sense and good judgement when enjoying any water activity.
SAVE THESE INSTRUCTIONS
Page 3
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
PARTS REFERENCE
Before assembling your product, please take a few minutes to check the contents
and become familiar with all the parts.
1
2
3
4
5
6
107
3
2
7
NOTE: Drawings for illustration purpose only. Actual product may vary. Not to scale.
" * ": Optional.
When ordering parts, be sure to quote the model number and part numbers.
SAVE THESE INSTRUCTIONS
Page 5
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
107
POOL OUTLET - STRAINER & PLUNGER VALVE SETUP (optional)
The strainer grid prevents large objects from jamming and/or damaging the filter pump.
The plunger valve assembly prevents water from flowing into the filter pump while the
filter cartridge is being placed or cleaned. If your pool has inflatable top ring, install the
strainer, nozzle and plunger valve before inflating the pool liner top ring. The parts
numbers here onward, refer to the parts depicted in the Parts List section of this manual.
To install, do the following:
1. In a counter-clockwise motion unscrew
plunger valve union from the threaded
strainer connector (13) (see drawing 1). Be careful not to lose the step rubber
washer (10). Place the plunger valve onthe ground in a safe place.
2. In a counter-clockwise motion unscrew the
strainer nut (11) from the threaded
connector (13). Leave the flat washer (12) on the connector (13).
3. Install the strainer and plunger valve at the
lower position of pool outlet (marked "+").
From the inside of the pool liner insert the
connector (13) into one of the pre-cut holeswith the washer remaining on the
connector to be placed against the inside
of the liner wall.
4. Before assembly, lubricate the threads with
a petroleum jelly. Then, with the flat side of
the strainer nut (11) facing the outside wall
of the liner in a clockwise motion screw the
strainer nut (11) back onto the threaded
connector (13) (see drawing 2).
5. Finger tighten the strainer nut (11) onto
the threaded connector (13).
6. Grasp the plunger valve assembly. Make
sure the step washer (10) is in place.
7. In a clockwise motion screw the plunger
valve union back onto the threaded
connector (13) (see drawing 3).
8. In a clockwise motion turn the plunger
valve handle to close position. Ensure the
plunger valve is securely closed. This will
prevent water from flowing out during filling
of the pool (see drawings 4.1).
9.NOTE: Never cover the vacuum release
valve (15) unless it is damaged or leaking. Replace the vacuum release valve
immediately.
11
2
INSIDE
LINER WALL
12
1
2
LINER WALL
15
13
INSIDE
1
1
2
3
4.1
4.2
POOL
SAVE THESE INSTRUCTIONS
WATER
FLOW
Page 6
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
107
POOL INLET - NOZZLE & PLUNGER VALVE SETUP (optional)
1. In a counter-clockwise motion unscrew
plunger valve union from the threaded
strainer connector (13) (see drawing 5). Be careful not to lose the step rubber
washer (10). Place the plunger valve onthe ground in a safe place.
2. In a counter-clockwise motion unscrew the
strainer nut (11) from the threaded
connector (13). Leave the flat washer (12) on the connector (13).
3. Install the nozzle and plunger valve at the
upper position of pool inlet. From the inside
of the pool liner insert the connector (13) into one of the pre-cut holes with the
washer remaining on the connector to be
placed against the inside of the liner wall.
4. Before assembly, lubricate the threads with
a petroleum jelly. Then, with the flat side of
the strainer nut (11) facing the outside wall
of the liner in a clockwise motion screw the
strainer nut (11) back onto the threaded
connector (13) (see drawing 6).
5. Finger tighten the adjustable pool inlet
nozzle (14) and the strainer nut (11) onto the threaded connector (13).
6. Grasp the plunger valve assembly. Make
sure the step washer (10) is in place.
7. In a clockwise motion screw the plunger
valve union back onto the threaded
connector (13) (see drawing 7).
8. In a clockwise motion turn the plunger
valve handle to close position. Ensure the
plunger valve is securely closed. This will
prevent water from flowing out during filling
of the pool (see drawing 8).
9.NOTE: Never cover the vacuum release
valve (15) unless it is damaged or leaking. Replace the vacuum release valve
immediately.
10. Adjust the direction of the nozzle head
pointing away from the pool outlet for a
better circulation result (see
drawing 9).
11. The pool liner is now ready to be filled with
water. Consult the above-ground-pool
owner’s manual for the filling instructions.
11
1
LINER WALL
12
1
2
15
2
INSIDE
1314
INSIDE
LINER WALL
WATER
FLOW
5
6
7
8
9
POOL
SAVE THESE INSTRUCTIONS
Page 7
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
FILTER PUMP HOSE CONNECTION SETUP
1. Remove the Krystal Clear™ filter pump and hoses from the packaging.
2. Place the filter pump in such a manner, that you can easily assemble the hose (7)
connections to the plunger valve.Note: Some regional regulations may require the filter pump to be mounted on a
stationary platform. There are two mounting holes located in the pump base for this
reason. Consult your local authorities for filter-pump mounting requirements.
3. Grasp the two pump hoses (7) and connect the hose nuts to the filter pump.
4. In a counter-clockwise motion unscrew the threaded filter housing collar (1) from the filter
housing. Place it in a safe place.
5. The filter pump is an airtight system. Turn the top air release valve (2) once or twice in a
counter-clockwise motion.
DO NOT remove the air release valve from the top cover, as water will expel with force
if the motor is turned on. This may cause injury.
6. Grasp and remove the filter housing cover (4). Check to see if a cartridge is inside the
housing. If yes, replace the cover, finger tighten the housing collar (1) back onto the filter
housing.
7. Gently finger tighten the sediment release valve located at the bottom of the housing to be
sure that water does not leak out.
8. When the pool is filled connect the hose from the bottom of the filter housing to the highest
strainer assembly. You will find the hose connection at the bottom of the plunger valve assembly. Use the hose nut to attach the hose.
9. Connect the second hose which is fixed to the middle of the motor housing to the remaining
liner connection.
107
WARNING
Position this product away from the pool, so as to prevent children from climbing
on it and accessing the pool.
WATER LEVEL
ADJUSTABLE POOL
INLET NOZZLE
INSIDE LINER
WALL
THREADED
STRAINER
CONNECTOR
OUTSIDE LINER
WALL
AIR RELEASE
VALVE
MOTOR
HOUSING
FILTER HOUSING
COVER
FILTER CARTRIDGE
O-RING
HOSE O-RING
POWER CORD
PLUNGER VALVE
ASSEMBLY
HOSE NUT
OUTLET HOSE
THREADED FILTER
HOUSING COLLAR
INSIDE
HOSE
W
INLET HOSE
W
O
L
F
R
E
T
A
W
W
O
L
F
R
E
T
A
(ILLUSTRATION NOT TO SCALE)
SAVE THESE INSTRUCTIONS
Page 8
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
OPERATING INSTRUCTIONS
1. Make sure the filter pump is switched off. The switch is located on the motor housing.
2. Connect the power cord to a GFCI protected electrical outlet.
WARNING
Risk of electric shock. Connect this product only to a grounding type receptacle
protected by a ground-fault circuit interrupter (GFCI). Contact a qualified electrician
if you cannot verify that the receptacle is protected by a GFCI.
IMPORTANT
To prevent air lock, open the lower plunger valve (connected inlet hose) first and
then the upper plunger valve (connected outlet hose). Open the air release valve,
wait until water starts to flow out of the air release valve, close air release valve.
3. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the
valve, allowing water to flow into the filter pump.
4. With water flowing into filter pump, the water pressure will allow the air trapped inside to
escape from the air release valve (2). When all the air has escaped water will flow out of
the valve (2). When this occurs gently finger tighten the valve (2) in a clockwise direction.NOTE: The plunger valve is equipped with a vacuum release valve that will
automatically activate to minimize the suction at the pool outlet if the outlet is blocked.
This is an additional safety feature to prevent suction entrapment. The vacuum release
valve will reset once the blockage is removed and the pump is switched off. To restart
the system the air must be removed from the filter pump per previous step.
5. To operate the filter pump on “TIMER” mode:
A. Set the timer dial to the desired operating hours. See operation time table.
See Fig. 10
B. Turn on the pump by pressing the switch to “ ” position, the filter pump is now
filtering the water and will stop after the operating hours are completed. The built-in
timer will now operate for the number of hours selected at the same time each day.
C. Operating hours can be re-adjusted if necessary. Follow step A – B.
To operate the filter pump manually (without the “TIMER” mode):A. Turn on the pump by pressing the switch to “-” position, the filter pump is now filtering
the water.
B. To turn off the pump, press the switch to “O” position.
107
FIG 10
SAVE THESE INSTRUCTIONS
6
8
4
OFF
12
TIMER
2
TIMER DIAL (HOURS)
ON
Page 9
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
OPERATING TIME TABLE
This table shows the required operating time for average use of the filter pump with AGP's.
The filter pump running time should be 1 hour longer than the required operating time of the
Saltwater System.
Pool Size
INTEX ABOVE GROUND POOLS (AGP’s)
EASY SET®
POOL
CIRCULAR
METAL FRAME
POOL
18’ x 42” (549cm x 107cm)4,78618,1154
18’ x 48” (549cm x 122cm)5,455 20,647 6
18’ x 48” (549cm x 122cm)6,423 24,311 6
21’ x 52”9,533 36,082 8
Water Capacity (Calculated at 90%
for Frame Pool and 80% for Easy Set
(Gals)
& Oval Pool)
(Liters)(Hours)
Recommend
operating hours
per day
107
ULTRA FRAME
POOL
SEQUOIA SPIRIT®
POOL SET
OVAL FRAME
POOL
RECT. ULTRA
FRAME POOL
16' x 48" (488cm x 122cm)5,061 19,156 4
18’ x 48” (549cm x 122cm)6,423 24,311 6
18’ x 52” (549cm x 132cm)6,981 26,423 6
20’ x 48”7,947 30,079 6
15’8” x 49”4,440 16,805 4
16'8" x 49" (508cm x 124cm)5,061 19,156 4
18'8" x 53" (569cm x 135cm)6,981 26,423 6
20’ x 12’ x 48” (610cm x 366cm x 122cm)
15’ x 9’ x 48”3,484 13,187 4
18’ x 9’ x 52” (549cm x 274cm x 132cm)
20’ x 10’ x 52”5,611 21,238 4
24’ x 12’ x 52” (732cm x 366cm x 132cm)
4,393 16,628 4
4,545 17,203 4
8,403 31,805 6
SAVE THESE INSTRUCTIONS
Page 10
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
CLEANING OR REPLACING FILTER CARTRIDGES
It is recommended that the filter cartridge be replaced at least every 2
weeks.
1. Make sure the filter pump is turned off, then disconnect the power cord from the electrical
outlet.
2. Turn both plunger valve handles fully clockwise until they stop. This closes the valve, prevents
the water from flowing out of the pool.
3. Gently turn the top air release valve once or twice in a counter-clockwise direction. The
housing cover can now be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (1). Place it in a safe location.
5. Remove the housing cover (4).
6. Now remove the used filter cartridge.
7. Examine the inside of the filter housing.
8. If dirt or sediment is located on the bottom of the housing then:
A. In a counter-clockwise motion gently unscrew and remove the sediment valve (2) located
at the bottom of the housing. Place it in a safe place.
B. With a bucket of water or a garden hose pour water into the housing flushing out the
sediment.
C. Screw back the sediment valve (2) in a gentle clockwise motion. Do not over-tighten.
9. Place a new cartridge filter in the housing.
10. Return the housing cover (4) to its position and in a clockwise direction rescrew the housing collar (1) onto the filter housing.
11. Turn both plunger valve handles fully counter-clockwise until they stop. This opens the valve,
allowing water to flow into the filter pump.
12. When the trapped air has escaped through the air release valve gently retighten the valve (2) in a clockwise direction.
13. Reconnect the power cord.
14. Turn on the pump.
107
SAVE THESE INSTRUCTIONS
Page 11
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
107
POOL CARE & CHEMICALS
•
All pools require care to keep the water clear and hygienically clean. With proper chemical control,
your filter will help attain this objective. Consult your pool supply dealer for instructions regarding
the proper use of chlorine, algaecide and other chemical agents required for sparkling clear water.
•
Keep pool chemicals away from children.
•
Do not replenish chemicals in pool while pool is occupied. Skin or eye irritations could occur.
•
Daily pH checking and chemical treatment of the water is very important and can not be
overemphasized. Chlorine, algaecide and maintenance of proper pH levels are required when
filling the pool as well as during the season. Consult your local swimming pool supply store for
instructions.
•
The season's first filling of the pool may have brackish water requiring extra water additives and
extra filter changes. Do not allow swimming in pool until the pH level is balanced. Consult your
local swimming pool supply store for instructions.
•
Keep spare filter cartridges on hand. Replace cartridges every two weeks.
•
Chlorinated water may damage lawns, gardens or shrubbery as children play in the pool and splash water outside the pool. Lawn areas underneath the pool liner will be destroyed. Note that
some types of grass may grow through the liner.
•
Filter run time depends on pool size, weather and usage level. Experiment with various run times
so as to produce clean clear water.
CAUTION
Concentrated chlorine solutions may damage the pool liner. Always follow the
chemical manufacturer’s directions, and the health and hazard warnings.
LONG TERM STORAGE
1. Before emptying your pool for long term storage, or relocation, be sure the water is directed
towards an acceptable drain water receptacle away from the house. Check local regulations for
specific directions regarding disposal of swimming pool water.
2. Disconnect power cord from electrical outlet.
3. Now, drain the pool.
4. When the pool is empty, disconnect all hoses from pump and plunger valves and remove the
strainers from the pool wall.
5. Drain all water from the filter pump.
6. Leave filter pump pieces & hoses outside to thoroughly air dry.
7. Remove both plunger valves from the threaded strainer connector (13). Be careful not to lose the step rubber washer (10).
8. Coat the following O-rings and washers with petroleum jelly for long term storage:
• Air release valve & sediment O-rings (3).
• Filter housing cover O-ring (5).
• Pump hose O-rings (9).
• Strainer valve assembly step washers (10).
• Flat strainer rubber washers (12).
9. Discard the used filter cartridge. Put aside 1 or 2 new cartridges for next season’s use.
10. It is best to place all dry pieces in the original packaging for storage or place them in an airtight
plastic bag.
11. Store the unit and accessories in a dry place. The storage's temperature should be controlled,
between 32 degrees Fahrenheit (0 degrees Celsius) and 104 degrees Fahrenheit (40 degrees
Celsius) storage location.
IMPORTANT
It is best to store away your poolsystem in its original packaging.
SAVE THESE INSTRUCTIONS
Page 12
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
TROUBLESHOOTING GUIDE
TROUBLECAUSESOLUTION
FILTER MOTOR FAILS
TO START
FILTER DOESN’T
CLEAN POOL
FILTER DOESN’T
PUMP WATER OR
THE WATER FLOW
IS VERY SLOW
PUMP DOESN’T
WORK
TOP COVER
LEAKING
• The motor is not plugged in.
• The GFCI circuit breaker is
tripped.
• Motor too hot and overload
protection shut motor off.
• Improper chlorine or pH
levels.
• Filter cartridge is dirty.
• Damaged cartridge.
• Excessively dirty pool.
• The strainer screen is
restricting the water flow.
• Clogged inlet or discharge.
• An air leak on the intake line.
• Scale or buildup on cartridge.
• Excessively dirty pool.
• Dirty filter cartridge.
• The nozzle and strainer
connection are reversed.
• The vacuum release valve
on the plunger valve is
activated.
• The vacuum release valve
on the plunger valve is leaking.
• Low water level.
• Strainer screen plugged up.
• An air leak on the intake hose.
• Faulty motor or the impeller is jammed.
• An air lock inside the cartridge chamber.
• O-ring missing.
•
Cover or air release valve are not tight.
• Filter cord must be plugged into a 3 wire
outlet that is protected by a Class A
Ground Fault Circuit Interrupter.
• Reset circuit breaker. If circuit breaker trips
repeatedly, your electrical system may
have a defect. Turn off circuit breaker and
call an electrician to correct the problem.
• Let motor cool down.
• Adjust the chlorine and pH level. Consult
your local swimming pool supply stores.
• Clean or replace cartridge.
• Check the cartridge for holes. Replace if
damaged.
• Operate the filter for longer periods.
• Clean the strainer screen at the inlet.
• Clear any obstructions in the intake hose by discharging it
inside pool wall.
• Tighten hose nuts, check hoses for damage, check pool
water level.
• Clean cartridge more often.
• Clean inside the plunger valve.
• Pull valve handle to full upright position.
• Install the nozzle at the upper position of the pool inlet,
and the strainer at the lower position of the pool outlet.
• Turn off pump, clear any debris or obstruction in the
outlet, remove all air from the filter pump and turn
pump on again.
• Turn off pump, if water leaking from the vacuum release
valve, then release valve needs to be replaced. Contact
Intex Service Center immediately to order replacement. You
may cover release valve with the cap temporarily if you
ensure that the strainer cover / strainer grid is installed and
you Do Not run the pump while pool is occupied.
• Fill pool to correct water level.
• Clean strainer screens at pool inlet.
• Tighten hose nuts, check hose for damage.
• Clear any sticks or leaves in the intake hose.
• Turn and pull valve handle to full upright position.
• Remove cover & check for O-ring.
• Tighten cover or valve (Manually).
English
107
HOSE LEAKING
AIR LOCK
• Hose nuts are not well-fitted.
• Hose o-ring dislodged when
connecting the hose.
• Hose broken.
• There’s air trapped in the
pump housing and inlet
hose.
• The inlet and outlet hoses
connection are reversed.
IMPORTANT
If you continue to experience difficulty, please contact our Consumer Service Department
for assistance. See separate “Authorized Service Centers” sheet.
SAVE THESE INSTRUCTIONS
• Tighten or reinstall hose nut.
• Put the o-ring back into the groove.
• Replacea new hose.
• Open air release valve, wait until water starts to flow
out of the air release valve, close air release valve.
• The lower position of pool outlet connects to filter
pump water inlet. The upper position of pool inlet
connects to filter pump water outlet.
Page 13
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
COMMON POOL PROBLEMS
TROUBLE DESCRIPTION CAUSE SOLUTION
ALGAE
COLORED
WATER
FLOATING
MATTER IN
WATER
• Greenish water.
• Green or black
spots on pool liner.
• Pool liner is
slippery and/or
has a bad odor.
• Water turns blue,
brown, or black
when first treated
with chlorine.
• Water is cloudy or
milky.
• Chlorine and pH
levels need
adjustment.
• Copper, iron or
maganese in water
being oxidized by
the added chlorine.
This is common.
• "Hard water" caused
by a too high pH level.
• Chlorine content is
low.
• Foreign matter in
water.
• Super chlorinate with shock
treatment. Correct pH to your
pool store's recommended
level.
• Vacuum pool bottom.
• Maintain proper chlorine
level.
• Adjust pH level to the
recommended level.
• Run filter until water is clear.
• Clean cartridge frequently.
• Correct the pH level. Check
with your pool dealer for
advice.
• Adjust the chlorine level.
• Clean or replace your filter.
107
CHRONIC LOW
WATER LEVEL
SEDIMENT
ON POOL
BOTTOM
SURFACE
DEBRIS
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this
device must accept any interference, including interference that may cause undesired operation of the device.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
• Level is lower than
on previous day.
• Dirt or sand on
pool floor.
• Leaves, insects
etc.
• Rip or hole in pool
liner or hoses.
• The drain valves are
loose.
• Heavy use, getting in
and out of pool.
• Pool too close to
trees.
• Repair with a patch kit.
• Finger tighten all caps.
• Use Intex pool vacuum to
clean bottom of pool.
• Use Intex pool skimmer.
SAVE THESE INSTRUCTIONS
Page 14
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
GENERAL AQUATIC SAFETY
Water recreation is both fun and therapeutic. However, it involves inherent
risks of injury and death. To reduce your risk of injury, read and follow all
product, package and package insert warnings and instructions. Remember,
however, that product warnings, instructions and safety guidelines cover some
common risks of water recreation, but do not cover all risks and dangers.
For additional safeguards, also familiarize yourself with the following general
guidelines as well as guidelines provided by nationally recognized Safety
Organizations:
• Demand constant supervision. A competent adult should be appointed as a
“lifeguard” or water watcher, especially when children are in and around the pool.
• Learn to swim.
• Take the time to learn CPR and first aid.
• Instruct anyone who is supervising pool users about potential pool hazards and
about the use of protective devices such as locked doors, barriers, etc.
• Instruct all pool users, including children what to do in case of an emergency.
• Always use common sense and good judgement when enjoying any water activity.
• Supervise, supervise, supervise.
107
For additional information on safety, please visit
• The Association of Pool and Spa Professionals: The Sensible Way to Enjoy Your
Aboveground/Onground Swimming Pool www.nspi.org
• American Academy of Pediatrics: Pool Safety for Children www.aap.org
• Red Cross www.redcross.org
• Safe Kids www.safekids.org
• Home Safety Council: Safety Guide www.homesafetycouncil.org
• Toy Industry Association: Toy Safety www.toy-tia.org
SAFETY IN YOUR POOL
Safe swimming depends on constant attention to the rules. The "NO DIVING" sign
within this manual can be posted near your pool to help keep everyone alert to the
danger. You may also wish to copy and laminate the sign for protection from the
elements.
SAVE THESE INSTRUCTIONS
Page 15
(107) MODEL 635T FILTER PUMP ENGLISH 7.5” X 10.3” PANTONE 295U 06/21/2013
English
107
LIMITED WARRANTY
Your Krystal Clear™ Filter-Pump has been manufactured using the highest quality
materials and workmanship. All Intex products have been inspected and found free of
defects prior to leaving the factory. This Limited Warranty applies only to the Krystal Clear™
Filter-Pump and accessories listed below.
The provisions of this Limited Warranty apply only to the original purchaser and is not
transferable. This Limited Warranty is valid for the period noted below from the date of
the initial retail purchase. Keep your original sales receipt with this manual, as proof of
purchase will be required and must accompany warranty claims or the Limited Warranty is
invalid. Krystal Clear™ Filter-Pump Warranty – 1 Year Hoses, Plunger Valves & Fittings Warranty – 180 days
If a manufacturing defect is found within the periods noted above, please contact the
appropriate Intex Service Center listed in the separate “Authorized Service Centers” sheet.
The Service Center will determine the validity of the claim. If the Service Center directs you
to return the product, please carefully package the product and send with shipping and
insurance prepaid to the Service Center. Upon receipt of the returned product, the Intex
Service Center will inspect the item and determine the validity of the claim. If the provisions
of this warranty cover the item, the item will be repaired or replaced at no charge.
PARTS LIST
Any and all disputes regarding the provisions of this Limited Warranty shall be brought
before an informal dispute settlement board and unless and until the provisions of
these paragraphs are carried forth, no civil action may be instituted. The methods and
procedures of this settlement board shall be subject to the rules and regulations set forth by
the Federal Trade Commission (F.T.C.). IMPLIED WARRANTIES ARE LIMITED TO THE
TERMS OF THIS WARRANTY AND IN NO EVENT SHALL INTEX, THEIR AUTHORIZED
AGENTS OR EMPLOYEES BE LIABLE TO THE BUYER OR ANY OTHER PARTY FOR
DIRECT OR CONSEQUENTIAL DAMAGES OR LIABILITIES. Some states, or
jurisdictions do not allow the exclusion or limitation of incidental or consequential damages,
so the above limitation or exclusion may not apply to you.
This Limited Warranty does not apply if the products are subject to negligence,
abnormal use or operation, accident, improper operation, improper voltage or current
contrary to operating instructions, or to damage by circumstances beyond Intex’s control,
including but not limited to, ordinary wear and tear and damage caused by exposure to fire,
flood, freezing, rain, or other external environmental forces. This Limited Warranty applies
only to those parts and components sold by Intex. The Limited Warranty does not cover
unauthorized alterations, repairs or disassembly by anyone other than Intex Service
Center personnel.
DO NOT GO BACK TO THE PLACE OF PURCHASE FOR RETURN
OR REPLACEMENT. IF YOU ARE MISSING PARTS OR NEED
ASSISTANCE, PLEASE CALL US TOLL-FREE (FOR U.S. AND
CANADIAN RESIDENTS): 1-800-234-6839 OR VISIT OUR WEBSITE:
WWW.INTEXSTORE.COM.
Proof of Purchase must accompany all returns or the warranty claim will be invalid.
SAVE THESE INSTRUCTIONS
Page 16
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.