Interquartz Gemini IQ330 Operating Instructions Manual

16
GEMINI SERIES
TELEPHONE
MODEL IQ330
OPERATING INSTRUCTIONS
1
1. FEATURES ....................................................................... 2
2. GENERAL CONTROLS AND INDICA T ORS .................... 3
MULTIFUNCTIONAL INDICATOR LIGHT ............................................................................. 4
RINGER VOLUME SWITCH ................................................................................................. 4
ALPHA-NUMERIC KEYPAD ................................................................................................. 4
CRADLE SWITCH ................................................................................................................ 4
RECALL KEY ........................................................................................................................ 4
BASIC OPERA TION.............................................................................................................. 5
REDIAL / PAUSE KEY .......................................................................................................... 5
HEARING-AID COMPATIBILITY ........................................................................................... 5
3. ADVANCED NETWORK OPERA TION ............................. 6
PAUSE FUNCTION WHEN DIALING.................................................................................... 6
HOLDING AND TRANSFERRING CALLS ............................................................................ 6
4. INSTALLATION................................................................. 7
UNPACKING ......................................................................................................................... 7
GENERAL SETTING-UP....................................................................................................... 7
LOCATION ............................................................................................................................ 7
WALL MOUNTING ................................................................................................................ 7
LINE CONNECTION ........................................................................................................... 10
TECHNICAL ADJUSTMENTS - FOR CORRECT OPERA TION ......................................... 10
MESSAGE WAITING LIGHT COMPATIBILITY ................................................................... 10
DATA PORT SWITCH ......................................................................................................... 11
SHARED MODE.................................................................................................................. 11
SPLIT MODE....................................................................................................................... 11
5. GENERAL CARE AND MAINTENANCE ........................ 12
CLEANING .......................................................................................................................... 12
FAILURE TO OPERA TE AND SERVICE DIFFICUL TIES.................................................... 12
6. THUNDERSTORMS ....................................................... 13
7. WARRANTY - 3 YEARS ................................................. 13
8. SERVICE CENTRES ...................................................... 14
2
1. FEATURES
Tone dialing
Super bright LED ringer lamp allows visual ringing indication
Built-in switchable Message Waiting option to suit a ny neon (80 V DC) type me ssage waiting system AND Ericsson BP250 Message W aiting (other system types optional)
User selectable ringer volume
Redial a nd Pause function s
Recall facility with flash timing 100 mS
Switchable data port allows connection to a second line to enable simultaneous voice a nd data
Compatible with direct lines, intelligent networks, PABXs and any an alog line
Call Waiting compatible
Telstra Customnet compatible
Line powered, unaffected by mains power interruption
REN (Ringer Equivalence Number) = 0.68 allows multiple parallel devices on the sa me line without loading incoming ring
Alpha-numeric keypad allows full access to services that require the entering of numerals a nd letters
Fully modular connection provides maximum ease of installation on desk or wall
3 years warranty
Hearing Aid compatibility
3
2. GENERAL CONTROLS AND INDICAT ORS
FIGURE 1 : TOP VIEW
FIGURE 1 : BOTTOM VIEW
(NOTES: EARLY VERSION WILL NOT HAVE THE DATA PORT SWITCH
FITTED, AND IS PERMANENTLY WIRED IN SHARED MODE.)
RINGER HI / LOW / OFF SWITCH
MESSAGE WAITING ON / OFF SWITCH
WALL MOUNT HOLE
HANDSET SOCKET
LINE SOCKET DATA SOCKET
MULTIFUNCTIONAL INDICATOR LIGHT
HANDSET
HANDSET CORD
REDIAL / PAUSE KEY
RECALL KEY
KEYPAD
DATA PORT (SHARED / SPLIT) SWITCH
4
MULTIFUNCTIONAL INDICATOR LIGHT
There are two different functions:
Ring Indicator: Flashes when the telephone rings with an incoming call
Message-Waiting Indicator: Illuminates when a message is waiting in your voicemail
system (depends on system compatibility). The built-in Message Waiting option suits any neon (80 VDC) type message waiting system and also the telephone has Ericsson BP250 Message W aiting built-in (other system types are optional extras).
RINGER VOLUME SWITCH
The three available positions allow selection of OFF (no sound), LOW volume, and HIGH volume of the telephone's ringing sound during an incoming call.
ALPHA-NUMERIC KEYP AD
The standard numeric digits are availa ble f or normal di aling. The alpha betic chara cters are provided to allow full access to services that require the entering of numerals and letters.
CRADLE SWITCH
Located in the handset cradle, this plastic lever is depressed by the handset (when placed in the cradle) to cut off the line. Note: Depressing this cradle lever too briefly when intending to terminate a call may result in an accidental "hookflash" that will inadvertently pla ce the call on hold. This is known as "pha ntom calls" because the held call will probably ring again at your extension within a few minutes (the other party will have hung up, so it will seem as if you were called by a phantom, hence the name "phantom calls"). If you experience this problem, when terminating your call please depress the cradle lever a little longer before making/receiving your next call (i.e. it is not a system or telephone fault).
RECALL KEY
For use with host telephone systems to invoke special network facilities such as call­hold or call-tran sfer available in your system.