IR2131
CONTROL INTEGRATED CIRCUIT DESIGNERS MANUAL B-159
Parameter Value
Symbol Definition Min. Typ. Max. Units T est Conditions
V
IH
Logic “0” Input Voltage (OUT = LO) 2.2 — —
V
IL
Logic “1” Input Voltage (OUT = HI) — — 0.8
V
FCLR,IH
Logic “0” Fault Clear Input Voltage 2.2 — —
V
FCLR,IL
Logic “1” Fault Clear Input Voltage — — 0.8
V
SD,TH+
Shutdown Input Positive Going Threshold 1.2 1.8 2.1
V
SD,TH-
Shutdown Input Negative Going Threshold 0.9 1.5 1.8
V
IT,TH+
ITRIP Input Positive Going Threshold 250 4 85 600
V
IT,TH-
ITRIP Input Negative Going Threshold 200 4 00 550
V
OH
High Level Output Voltage, V
BIAS
- VO — — 100 VIN = 0V, IO = 0A
V
OL
Low Level Output Voltage , VO — — 100 VIN = 5V, IO = 0A
I
LK
Offset Supply Leakage Current — — 50 VB = VS = 600V
I
QBS
Quiescent VBS Supply Current — 30 10 0 VIN = 0V or 5V
I
QCC
Quiescent VCC Supply Current — 3.0 4.5 mA VIN = 0V or 5V
I
IN+
Logic “1” Input Bias Current (OUT = HI) — 190 300 VIN = 0V
I
IN-
Logic “0” Input Bias Current (OUT = LO) — 50 10 0 µA VIN = 5V
I
ITRIP+
“High” ITRIP Bias Current — 75 150 ITRIP = 5V
I
ITRIP-
“Low” ITRIP Bias Current — — 100 nA ITRIP = 0V
I
FCLR+
Logic “1” Fault Clear Bias Current — 12 5 250
FLT- CLR = 0V
I
FCLR-
Logic “0” Fault Clear Bias Current — 75 15 0 µA
FLT- CLR = 5V
I
SD+
Logic “1” Shutdown Bias Current — 75 15 0 SD = 5V
I
SD-
Logic “0” Shutdown Bias Current — — 100 nA SD = 0V
Parameter Value
Symbol Definition Min. Typ. Max. Units Test Conditions
t
on
Tur n-On Propagation Delay 0.6 1.3 2.0
t
off
Tur n-Off Propagation Delay 0.2 0.6 1.0 V
IN
= 0 & 5V
t
r
Tur n-On Rise Time — 80 150 V
S1,2,3
= 0 to 600V
t
f
Tur n-Off Fall Time — 40 100
t
itrip
ITRIP to Output Shutdown Propagation Delay 400 700 1000 VIN, V
ITRIP
= 0 & 5V
t
bl
ITRIP Blanking Time — 400 — V
ITRIP
= 1V
t
flt
ITRIP to
FAULT
Indication Delay 400 700 1000 ns V
IN
, V
ITRIP
= 0 & 5V
t
flt,in
Input Filter Time (All Six Inputs) — 3 10 — V
IN
= 0 & 5V
t
fltclr
FLT -CLR
to
FAULT
Clear Time 400 700 1000 V
IN
, VIT, V
FC
= 0&5V
t
sd
SD to Output Shutdown Propagation Delay 400 700 1000 VIN, V
SD
= 0 & 5V
DT Deadtime 400 700 1200 V
IN
= 0 & 5V
Dynamic Electrical Characteristics
V
BIAS
(VCC, V
BS1,2,3
) = 15V, V
S1,2,3
= VSS = COM, CL = 1000 pF and TA = 25°C unless otherwise specified. The
dynamic electrical characteristics are defined in Figures 4 through 5.
Static Electrical Characteristics
V
BIAS
(VCC, V
BS1,2,3
) = 15V, V
S1,2,3
= VSS = COM and TA = 25°C unless otherwise specified. The VIN, VTH and I
IN
parameters are referenced to VSS and are applicable to all six logic input leads:
HIN1,2,3
&
LIN1,2,3 . The V
O
and I
O
parameters are referenced to COM and V
S1,2,3
and are applicable to the respective output leads: HO1,2,3 or LO1,2,3.
µs
µA
mV
V