International Rectifier HFA105NH60R Datasheet

PD-2.443
d
Next Data SheetIndex
Previous Datasheet
To Order
HFA105NH60R
Features
TM
LUG TERMI NAL CATHODE
Ultrafast, Soft Recovery DiodeHEXFRED
• Reduced RFI and EMI
• Reduced Snubbing
• Extensive Characterization of Recovery Parameters
a
BASE ANODE
Description
HEXFREDTM diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors drives and other applications where switching losses are significant portion of the total losses.
Absolute Maximum Ratings
Parameter Max. Units
V
R
IF @ TC = 25°C Continuous Forward Current 147 IF @ TC = 100°C Continuous Forward Current 72 I
FSM
I
AS
E
AS
PD @ TC = 25°C Maximum Power Dissipation 379 PD @ TC = 100°C Maximum Power Dissipation 152 T
J
T
STG
Cathode-to-Anode Voltage 600 V
Single Pulse Forward Current 600 Maximum Single Pulse Avalanche Current 2.0 Non-Repetitive Avalanche Energy 220 µJ
Operating Junction and Storage Temperature Range
-55 to +150
VR = 600V
VF = 1.5V
Qrr * = 1200nC
di
/dt * = 240A/µs
(rec)M
* 125°C
HALF-PAK
A
W
°C
Thermal - Mechanical Characteristics
R
θJC
R
θCS
Wt Weight –––– 26 (0.9) –––– g (oz)
Note: Limited by junction temperature
L = 100µH, duty cycle limited by max T
Parameter Min. Typ. Max. Units Junction-to-Case, Single –––– –––– 0.33 Case-to-Sink, Flat , Greased Surface –––– 0.15 ––––
Mounting Torque 15 (1.7) –––– 25 (2.8) lbf•in Terminal Torque 20 (2.2) –––– 40 (4.4) (N•m)
J
°C/W K/W
HFA105NH60R
Next Data SheetIndex
Previous Datasheet
To Order
Electrical Characteristics @ TJ = 25°C (unless otherwise specified)
Parameter Min. Typ. Max. Units Test Conditions
V
BR
V
FM
I
RM
C
T
L
S
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified)
t
rr
t
rr1
t
rr2
I
RRM1
I
RRM2
Q
rr1
Q
rr2
di
(rec)M
di
(rec)M
Cathode Anode Breakdown Voltage 600 ––– ––– V IR = 100µA Max Forward Voltage 1.3 1.5 IF = 105A
––– 1.5 1.7 V IF = 210A
1.2 1.4 IF = 105A, TJ = 125°C
Max Reverse Leakage Current 6.0 30 µA VR = VR Rated
1.5 6.0 mA TJ = 125°C, VR = 480V
Junction Capacitance ––– 200 300 pF VR = 200V Series Inductance ––– 6.0 ––– nH
From top of terminal hole to mounting plane
Parameter Min. Typ. Max. Units Test Conditions Reverse Recovery Time ––– 35 ––– IF = 1.0A, dif/dt = 200A/µs, VR = 30V
––– 90 140 ns TJ = 25°C ––– 160 240 TJ = 125°C IF = 105A
Peak Recovery Current ––– 10 18 TJ = 25°C
––– 15 30 TJ = 125°C VR = 200V
Reverse Recovery Charge ––– 450 1300 TJ = 25°C
––– 1200 3600 TJ = 125°C dif/dt = 200A/µs /dt1 Peak Rate of Fall of Recovery Current ––– 310 ––– TJ = 25°C /dt2 During t
b
––– 240 ––– TJ = 125°C
A
nC
A/µs
1/4-20 UNC-2B
4.11 (0.162)
3.86 (0.152)
14.10 (0.555)
13.59 (0.535)
12.83 (0.505)
12.57 (0.495)
2
30.40 (1.197)
29.90 (1.177)
DIA.
39.62 (1.560)
38.61 (1.520)
1
19.69 (0.775)
18.42 (0.725)
4.11 (0.162)
3.86 (0.152)
19.18 (0.755)
18.92 (0.745)
DIA.
SQ.
15.75 (0.620)
14.99 (0.590)
3.30 (0.130)
3.05 (0.120)
LEAD ASSIGNMENTS 1 - CATHODE 2 - ANODE
Dimensions in millimeters and inches
ALF- AK
H P
Loading...