International Rectifier HFA100MD60C Datasheet

PD-2.442
L
Next Data SheetIndex
Previous Datasheet
To Order
HFA100MD60C
TM
Features
• Reduced RFI and EMI
LUG TERMINAL ANODE 1
LUG TERMINAL CATHODE
Ultrafast, Soft Recovery DiodeHEXFRED
LU G TERMINA ANODE 2
• Reduced Snubbing
• Extensive Characterization of Recovery Parameters
BASE (ISOLATED)
Description
HEXFREDTM diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors drives and other applications where switching losses are significant portion of the total losses.
Absolute Maximum Ratings (per Leg)
V
R
IF @ TC = 25°C Continuous Forward Current 83 IF @ TC = 100°C Continuous Forward Current 40 I
FSM
I
AS
E
AS
PD @ TC = 25°C Maximum Power Dissipation 180 PD @ TC = 100°C Maximum Power Dissipation 71 T
J
T
STG
Cathode-to-Anode Voltage 600 V
Single Pulse Forward Current 400 Maximum Single Pulse Avalanche Current 2.0 Non-Repetitive Avalanche Energy 220 µJ
Operating Junction and Storage Temperature Range
-55 to +150
VR = 600V
VF = 1.4V
Qrr * = 780nC
di
/dt * = 240A/µs
(rec)M
* 125°C
TO-244AB (ISOLATED)
A
W
C
Thermal - Mechanical Characteristics
R
θJC
R
θCS
Wt Weight –––– 79 (2.8) –––– g (oz)
Note: Limited by junction temperature
L = 100µH, duty cycle limited by max T
Parameter Min. Typ. Max. Units Junction-to-Case, Single Leg Conducting –––– –––– 0.70 Junction-to-Case, Both Legs Conducting –––– –––– 0.35 Case-to-Sink, Flat , Greased Surface –––– 0.10 ––––
Mounting Torque 35 (4.0) –––– 50 (5.7) Terminal Torque 50 (5.7) –––– 75 (8.5)
See Fig. 12
J
°C/W K/W
lbf•in
(N•m)
HFA100MD60C
Next Data SheetIndex
Previous Datasheet
To Order
Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
Parameter Min. Typ. Max. Units Test Conditions
V
BR
V
FM
I
RM
C
T
L
S
Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified)
t
rr
t
rr1
t
rr2
I
RRM1
I
RRM2
Q
rr1
Q
rr2
di
(rec)M
di
(rec)M
Cathode Anode Breakdown Voltage 600 ––– ––– V IR = 100µA Max Forward Voltage 1.2 1.4 IF = 50A
––– 1.4 1.6 V IF = 100A
1.1 1.3 IF = 50A, TJ = 125°C
Max Reverse Leakage Current 4.0 20 µA VR = VR Rated
1.0 4.0 mA TJ = 125°C, VR = 480V
Junction Capacitance ––– 140 250 pF VR = 200V Series Inductance ––– 7.0 ––– nH
From top of terminal hole to mounting plane
Parameter Min. Typ. Max. Units Test Conditions Reverse Recovery Time ––– 33 ––– IF = 1.0A, dif/dt = 200A/µs, VR = 30V
––– 76 115 ns TJ = 25°C ––– 130 200 TJ = 125°C IF = 50A
Peak Recovery Current ––– 8.0 15 TJ = 25°C
––– 12 22 TJ = 125°C VR = 200V
Reverse Recovery Charge ––– 300 900 TJ = 25°C
––– 780 2200 TJ = 125°C dif/dt = 200A/µs /dt1 Peak Rate of Fall of Recovery Current ––– 340 ––– TJ = 25°C /dt2 During t
b
––– 240 ––– TJ = 125°C
A
nC
A/µs
7.49 (0.295)
6.99 (0.275) (2 PLCS.)
23.55 (0.927)
20.42 (0.804)
DIA.
40.26 (1.585)
39.75 (1.565)
1
80.01 (3.150)
34.925 (1.375) REF.
63.50 (2.500)
60.96 (2.400)
2 3
92.71 (3.650)
90.17 (3.550)
20.32 (0.800)
17.78 (0.700)
1/4-20 SLOTTED HEX
15.75 (0.620)
14.99 (0.590)
3.35 (0.132)
3.02 (0.119)
LEAD ASSIGNMENTS 1 - ANODE 2 - CATHODE 3 - ANODE
OUTLINE TO-244AB (IS OLATE D)
Dimensions in Millimeters and (In ches)
Loading...
+ 3 hidden pages