International Comfort Products CRLVHLGD004A00, CRLVHLGD011A00, CRLVHLGD016A00, CRLVHLGD020A00, CRLVHLGD024A00 Installation Manual

...
CRLVHLGD004A00 CRLVHLGD011A00-­CRLVHLGD016A00, CRLVHLGD020A00-­CRLVHLGD024A00 CRLVHLGD032A00
Installation Instructions
SMALL ROOFTOP UNITS
ACCESSORY LOUVERED HAIL GUARD
GAS HEATING/ELECTRIC COOLING,
3to12---1/2TONS
PACKAGE USAGE
50TCQ08--- 12 548J*08---12 CRLVHLGD004A00
48/50TC*04,
50TCQA04
48/50TC*05--- 06
50TCQA05
48LC/50LC*04
48/50HC*04
48/50TC*07
50TCQA07
48/50LC*05--- 06
48/50HC*05---06
48/50TC*A, D 08{
48/50HC*07
48/50TC*A09{ 580J*09(A,C){/558J*09(A){ CRLVHLGD015A00
48/50TC--- D09{,
48/50TC*A,D12{,
48/50TC*D14{
48/50HC*08---12
48/50TC*D08 580J*08(D,F)/558J*08D CRLVHLGD020A00 48/50TC*D12 580J*12(D,F)/558J*12D CRLVHLGD021A00 48/50TC*D14 580J*14(D,F)/558J*14(D) CRLVHLGD022A00
50TCQA06 548J*06 CRLVHLGD023A00
48/50TC*16{
48/50HC*14
{ Round tube plate fin outdoor coil only
Rooftop Unit Model Hailguard
580J*04/558J*04,
548J*04
580J*05---06/558J*05 --- 06,
548J*05
581J*04/551J*04
580J*07/558J*07,
548J*07
581J*05---06/551J*05 --- 06
580J*08{/558J*08{
581J*07/551J*07
580J*09(D,F,K,M){/580J*12{,
580J*14 (D,F,K,M){/
558J*09(D,K){
558J*12{,
558J*14(D,K){
581J*08---12/551J*08 --- 12
50TCQ14 548J*14 CRLVHLGD024A00
580J*16{/558J*16{
581J*14/551J*14
CRLVHLGD011A00
CRLVHLGD012A00
CRLVHLGD013A00
CRLVHLGD014A00
CRLVHLGD016A00
CRLVHLGD032A00
ICP PACKAGE USAGE
Rooftop Unit Model{ Hailguard
RHS090---120 CRLVHLGD004A00
RGS/RAS036, RHS036 CRLVHLGD011A00
RGS/RAS048--- 060
RHS048, RGH/RAH036 RGS/RAS072, RHS072,
RGH/RAH048---060
RGS/RAS090, 091, RGH /RAH072 CRLVHLGD014A00
RGS/RAS101 CRLVHLGD015A00
RGS/RAS102, RGS/RAS121.120,
RGS/RAS150, RGH/RAH090 102, 120
{ Round tube plate fin outdoor coil only
RHS060 CRLVHLGD023A00 RHS150 CRLVHLGD024A00
RGS/RAS180, RGH/RAH150 CRLVHLGD032A00
CRLVHLGD012A00
CRLVHLGD013A00
CRLVHLGD016A00
PACKAGE CONTENTS
QTY CONTENTS
1 Outside coil side panel
1 Outside coil end panel
1 Control box side panel*
10 Plastic inserts*
Varies based on kit Screws
* CRLVHLGD024A00 and 032A00
SAFETY CONSIDERATIONS
Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment.
Untrained personnel can perform basic maintenance functions of cleaning coils and filters and replacing filters. All other operations should be performed by trained service personnel. When working on air-conditioning equipment, observe precautions in the literature, tags and labels attached to the unit, and other safety precautions that may apply.
Follow all safety codes. Wear safety glasses and work gloves.
Recognize safety information. This is the safety--alert symbol
instructions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, and CAUTION. These words are used with the safety--alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies a hazard which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
ELECTRICAL OPERATION HAZARD
Failure to follow this warning could result in personal injury or death.
Before performing service and maintenance operations on unit, turn off main power switch to unit. If gas unit, shut off gas supply before shutting off main power. TAG DISCONNECT SWITCH WITH A SUITABLE LOCK AND WARNING LABEL.
IMPORTANT: Read these instructions completely before attempting to install the accessory louvered hail guard.
. When you see this symbol on the unit and in
!
WARNING
GENERAL
Louvered hail guard packages are designed to protect the rooftop unit condenser coil from hail and general contact damage. Excessive damage to rooftop unit outdoor coils can result in diminished performance due to reduced air flow over the heat transfer surfaces.
INSTALLATION
(FOR ALL KITS EXCEPT
CRLVHLGD024A00 AND 032A00)
1. Verify the correct hail guard part number is provided for the desired rooftop unit size. See Package Usage section above.
2. Remove the screws in the top panel of the rooftop unit above the condenser coil. Save the screws.
3. Remove the screws at the base of the outdoor coil where the hailguard panel will be installed. Save the screws.
4. Align the hailguard panel with the respective section of the outdoor coil and insert the top edge of the panel under the lip of the top panel. (See Fig.
1.)
5. Re--insert top and bottom screws from Steps 2 and 3 to hold the hailguard in place.
6. Insert side screws from the kit through the holes in the side(s) of the hailguard panels. The provided self tapping screws may be required for these screws.
Fig. 1 -- Typical Louvered Hailguard Installation
(3--5 Ton Unit Shown)
2