Intermatic 158ET8899 User Manual

®
ELECTRONIC 7-DAY WATER ­HEATER TIME SWITCHES MODELS EH10 AND EH40
WITH BATTERY CARRYOVER
PROG
MAN
DAY
AUTO
TIME
SET
MIN
HOUR
®
Y
TTER
BA
RESET
ON
OFF
LOAD
EVENT
Fig.1
OWNER/INSTALLER INSTRUCTION MANUAL
ATTENTION: READ CAREFULLY BEFORE ATTEMPTING TO INSTALL YOUR INTERMATIC TIME SWITCH. FAIL­URE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN FOR FUTURE REFERENCE.
Set Points (Events) - 12 total (6 ON/6 OFF) - Can be assigned in any combination to weekdays, weekend days, daily or weekly operation providing up to a maximum of 84 weekly operations (42 ON/42 OFF). Battery Powered Clock Operation - 3 years minimum, AA industrial grade alkaline supplied with time switch.
Minimum ON/OFF Time - 1 Minute Maximum ON/OFF Time - 6 days 23 hours 59 minutes Shipping Weight - 2.37 Lbs. (1.05 Kg) Case - Drawn steel, 7-3/4” (19.7 cm) high, 5” (12.7cm)
wide, 3” (7.6 cm) deep; gray finish with lockable spring hasp, clear see-through viewing window and external over­ride. Knockouts - Combination of 1/2 - 3/4” (one on back and each side, two on bottom)
Wire Size - AWG #10 through #18
GENERAL SAFETY INFORMATION:
WARNING: DISCONNECT THE POWER TO THE TIME SWITCH AND THE LOADS BEFORE INSTALLING THIS TIME SWITCH.
1. Mount the time switch in the desired location using the three mounting holes which are provided. Mount the time switch at eye level, if possible, providing sufficient room to the left of the enclosure for the cover to swing open fully. (See Fig. #2). The time switch mechanism does not need to be removed from the enclosure to mount the time switch since the top mount­ing hole is a slotted type mounting hole. Secure a screw or other fastener at eye level. The head of the screw of fastener should be slightly larger than the narrow portion of the slotted hole to ensure that the time switch is securely held in place. The remaining two mounting holes provide a means to secure the time switch.
2. If you do remove the mechanism, refer to Figure #3 and remove the mechanism from the case by depressing the catch at the top of the case and pulling out. CAUTION: DO NOT TOUCH THE CIRCUIT BOARD COMPONENTS SINCE STATIC DISCHARGE COULD DAMAGE THE MICROPROCESSOR.
Mounting Holes
Snap Out Catch
Tilt Top Forward
MANUAL (MAN) - AUTOMATIC (AUTO)
(See Fig. 1)
MANUAL: Bypasses your program completely; timer will not resume program until you return switch to AUTO mode position.
AUTOMATIC: For automatically switching at ON/OFF
times; accurate to-the-minute.
PROGRAM (PROG) - RUN - TIME SET
PROGRAM: Use this position when programming.
RUN: Use this position for normal operation. Be sure to
return to RUN after setting time and program.
TIME SET: Use this position to set day and time of day.
ON/OFF - EVENT (the large push button) - Serves a dual purpose
• EVENT:
Used for programming (active only when switch
is set at PROG)
• ON/OFF: Override (active only when switch is set at
RUN); turns load ON if already off or OFF if already on. Timer automatically resumes program cycle only when slide switch is in AUTO. Note that this button is also accessible without opening the enclosure.
SPECIFICATIONS:
Clock Voltage - Model EH40 - 240V. A.C., 50/60 Hz
Power Consumption - EH10 - 1.0 W. Max. EH40 - 3.0
W. Max.. Contact Configuration - EH10 (SPST) Single pole-single throw model-EH40(DPST) Double pole-single throw model
Switch Rating (Per Pole) -
• 30 amp inductive/resistive - 120-240V. A.C., 60 Hz
• 1 H.P. 120V. A.C., 60 Hz.
• 1-1/2 H.P. 240V. A.C., 60 Hz.
• 5 amp tungsten, 120-240V. A.C., 60 Hz.
EH10 - 120V. A.C., 50/60 Hz
Lift Up To Remove
Fig.2
Ground Terminal
Knockouts
Fig. 3
3. Replace the mechanism in the case if it has been removed, making sure to engage ribs at sides of mechanism between ears at sides of case before snapping in place.
4. Lift the left side of the insulator off of the retaining post and pivot it up and away to expose the terminal screws.
5. Strip the supply and load wires by removing 1/2 inch of insulation.
DO NOT USE ALUMINUM WIRE. Insert
the wire ends under the proper terminal plates and tighten the screws firmly. Use any size wire, AWG #10 through #18. Connect ground wire to grounding terminal at bottom of case.
6. Replace the plastic insulator.
7. Follow instructions for battery installation. Be sure that the battery is functioning properly. This can be checked by seeing that the display is visible. If the display has scrambled information, check to be sure that the polarity orientation of the battery is as shown on the cover label, then press the RESET switch and hold for at least two seconds. Note that the battery can easily be replaced without removing the time switch mechanism or field wiring. Simply press in and downward (in the direction of the arrow) on the battery cover which is identified with the word “Battery”. It is recommended that the battery be replaced with a “AA” industrial grade alkaline cell at two to three
year intervals as part of the normal time switch maintenance observing battery polarity markings when installing. No other maintenance is required. Place the slide switches in the AUTO and RUN position.
8.
9. Reapply power to the time switch.
10.Press the recessed reset switch for at least two seconds. The display will show 12:00 A.M. and MO. Note that the days of the week are identified with the first two letters of the day (MO for Monday). The timer is now ready for programming. Refer to the examples which follow and enter the scheduled events
(set points) required. Assign each of the 12 set
points (EVENTS) entered to whichever day or groups of days of the week you wish an ON or OFF operation to occur.
Set Point = Event = ON = OFF
TIMER
POWER
1
LINE 1
240
Fig. 5
23
LINE 2
LINE 1
EH40
See
Pg. 7
4
56
LINE 2
LOAD
1
NEUTRAL
EH10
TIMER
POWER
234
LINE
120
LINE
Fig. 4
See
Pg. 7
LOAD
NEUTRAL
PROGRAMMING STEPS: SET CURRENT DAY AND TIME
Slide switch to TIME SET. Push DAY until current day shows, then push HOUR until current hour AM or PM shows. Now push MINUTE until current minute shows. Clock is now set. Follow same procedure after replacing battery or changing time (such as for daylight saving time).
SET YOUR PROGRAM
Slide switch to PROG. Display will look like this: (-:- -)
Press DAY until desired program period shows (see
choices in “PROGRAM PERIOD OPTIONS” section
above).
Press HOUR until desired “ON 1” hour shows (that
is, the first time each day of the program period that
you want the load to turn ON).
Press MINUTE until desired minute shows.
Press EVENT to program time for ON 1 (and to
advance to programming for OFF 1).
Press DAY again until all seven days of the week
show (or until another desired program period option shows; see “PROGRAM PERIOD OPTIONS”).
Press HOUR again until desired “OFF 1” hour shows
(that is, the first time each day of the program period that you want the devices to turn OFF).
Press MINUTE until desired minute shows.
Press EVENT to set time for OFF 1. You may now
begin setting ON 2, a second ON time, for the same program period, OR press DAY to change to a different program period.
Repeat above procedure until all desired ON/OFF
programs are set.
PLEASE NOTE: Before you program your timer, or when you remove the battery, or when you use the RESET, pressing EVENT will display the bar symbol -:-- ON 1. Repeated press­ing of EVENT will display all the way through the final bar sym­bol -:-- OFF 6. Once you program your timer, however, each actual time setting you make will replace the bar symbol. While programming, each time you press EVENT you will advance to the next EVENT.
PROGRAM PERIOD OPTIONS:
Your timer gives you up to 6 different ON and 6 different OFF settings per program period. You can use all 6 settings per peri­od, or as few as you like. Aprogram period covers one of these:
ALL 7 DAYS OF THE WEEK combined into one -
display shows: MO TU WE TH FR SA SU.
MONDAY THRU FRIDAY combined into one -
display shows: MO TU WE TH FR.
SATURDAY AND SUNDAY combined into one -
display shows: SA SU
- 2 -
EACH INDIVIDUAL DAY OF THE WEEK -
display shows only that day.
BLANKDAY EXPLANATION - “BLANKDAY”
follows Sunday after last push of DAY button (when the lower slide switch is set at PROGRAM). The purpose of the BLANKDAY is to disable a program
setting on a day. Program periods with days “combined into one” help you make settings for those multiple days quickly and conve­niently while using only one ON/OFF pair. When you set such a program period, all settings will be identical for every day of that period.
PERSONAL
DAY CHECKS ON TIMES OFF TIMES DISPLAYED DAYS & TIMES DISPLAYED
EXAMPLE 1 MO TU WE TH FR SA SU 5:00 PM 10:00 PM ON 1 MO TU WE TH FR SA SU 5:00 PM
EXAMPLE 2 MO TU WE TH FR
10:00 PM SA SU 4:00 PM 8:00 PM ON 2 SA SU 4:00 PM
EXAMPLE 3 MO TU WE TH FR 6:00 AM 9:30 AM ON 1 MO TU WE TH FR 6:00 AM
MO TU WE TH FR 5:30 PM 11:15 PM ON 2 MO TU WE TH FR 5:30 PM
SA SU 3:00 PM 10:00 PM ON 3 SA SU 3:00 PM
EXAMPLE 4 MO TU WE TH 8:00 PM 11:30 PM ON 1 MO TU WE TH 8:00 PM
FR SA 5:00 PM 2:20 PM ON 2 SU 7:00 PM
SU 7:00 PM 10:30 PM ON 3 FR 5:00 PM
EVENTS
6:00 PM 10:00 PM ON 1 MO TU WE TH FR 6:00 PM
PROGRAM EXAMPLES
OFF 1
OFF 1 MO TU WE TH FR
OFF 2 SA SU 8:00 PM
OFF 1 MO TU WE TH FR 9:30 AM
OFF 2 MO TU WE TH FR 11:15 PM
OFF 3
OFF 1 MO TU WE TH 11:30 PM
(DAY AFTER) OFF 2 SU 10:30 PM
OFF 3 ON 4 OFF 4 ON 5 “BLANKDAY” -:- ­OFF 5 WE 11:30 PM ON 6 “BLANKDAY” -:- ­OFF 6 TH 11:30 PM
SA SU 10:00 PM
MO 11:30 PM SA 5:00 PM TU 11:30 PM
NOTE: “-:- -” follows Sunday after last push of DAY button (when the slide switch is set at PROG). The purpose of the
-:- - is to cancel a program setting on that day.
REVIEW YOUR PROGRAM
Slide switch to PROG. Press EVENT button to advance display to each ON or OFF setting. Check days and times displayed. To make a change, follow instructions under “SET YOUR PROGRAM”. To delete a displayed set point, press DAY button until “-:- -” is displayed.
GENERAL FEATURES AND HINTS FOR TROUBLE­FREE USE
BUTTON: When you press a button, there is an advance
of one time unit; holding a button down advances contin­uously until released.
MAINTENANCE: With the exception of battery replace-
ment at 2-3 year intervals, your Intermatic timer is maintenance-free.
AFTER THE INSTALLATION IS COMPLETED, THE
LOCKABLE HASP SHOULD BE MOVED TO THE UP POSITION TO ENGAGE THE COVER WHEN IT IS CLOSED.
If within one (1) year from the date of purchase, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it free of charge. The warranty does not apply to (a) damage caused by accident, abuse, mis handling or dropping: (b) units which have been subject to unau­thorized repair, opened, taken apart; (c) units not used in accor­dance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. This warranty service is available by either (a) returning the prod­uct to the dealer from whom the unit was purchased, or (b) mail ing postage prepaid to the authorized service station listed below. Please be sure to wrap the product securely when mailing to avoid damage. Intermatic Plaza, Spring Grove, Illinois 60081-9698.
INTERMA
158ET8805 PRINTED IN U.S.A.
FULL ONE YEAR WARRANTY
This warranty is made by: Intermatic Incorporated,
AUTHORIZED SERVICE STATION
INTERMATIC INCORPORATED
4720 West Montrose Avenue
Chicago, Illinois 60641
SPRING GROVE, ILLINOIS 60081-9698
TIC INCORPORA
TED
-
-
®
MINUTERIE ÈLECTRONIQUES DE 7 JOURS MODÈLE EH10 ET EH40 avec pile de secours
INSTRUCTIONS D’INSTALLATION ET MODE D’EMPLOI
ATTENTION: LIRE ATTENTIVEMENT LA PRÉSENTE NOTICE AVANT D’ÉFFECTUER L’INSTALLATION DE LA MINUTERIE INTERMATIC. LE NON-RESPECT DES INSTRUCTIONS RISQUE D’OCCASIONNER DES BLESSURES ET/OU DES DÉGATS MATÉRIELS! CONSERVER LA PRÉSENTE NOTICE POUR RÉFÉRENCE ULTÉRIEURE.
MANUEL-AUTOMATIQUE- (Voir Fig. 1)
MANUAL: Mettez le commutateur en cette position pour
contourner entièrement votre programme; la minuterie ne reprend la programmation que lorsque le commutateur est remis en position AUTOMATIC (AUTOMATIQUE).
AUTOMATIC: Mettez le commutateur en cette position pour
des horaires ON/OFF d’une précision à la minute.
PROGRAMMATION-EXÉCUTION-RÉGLAGE D’HORAIRE
PROGRAM (PROGRAMMATION): Mettez le commutateur en
cette position pour la programmation.
RUN (EXÉCUTION): Mettez le commutateur en cette position
pour un fonctionnement normale.
TIME SET (RÉGLAGE D’HORAIRE): Mettez le commutateur
en cette position pour programmer l’heure.
BOUTON DOUBLE-FONCTION
Programmation EVENT (ÉVÉNEMENT) (fonction activée
seulement lorsque le commutateur est mis en position
PROGRAM)
Reprise de contrôle ON/OFF (fonction activée seulement
lorsque le commutateur est mis en position RUN); active la marche des dispositifs s’ils sont déjà en arrêt ou leur arrêt s’ils sont déjà en marche. La minuterie reprend automatiquement le programme à partir du prochain cycle.
SPÉCIFICATIONS
Tension de l’Horloge
Consommation d’electricite
Configuration des contacts
Valeurs Nominales des Contacts (par pole)
30 A. Inductif/Resistif 120/240 VAC, 60 Hz
1 CH, 120 V
1-1/2 CH, 240 VAC, 60 Hz
5 A. Tungstene 120/240 VAC, 60 Hz
Points Reglables (Evenements) Votre minuterie fournit jusqu’a 6
differents relages d’arret par periode de programmation. Vous pouvez les utiliser tous le 6 en une seule periode ou n’en utiliser que le nombre qui vous convient.
Dispositif de pile de secours 3 ans minimum. Duree Marche/Arret min. - 1 min. Duree Marche/Arret max. - 6 jours, 23 heures, 59 min. Poids a l’expédition - 2.37 lbs (1.05 kg) Boîtier - Acier embouti 7-3/4 po (19.7 cm) de haut, 5 po (12.7 cm)
de large, 3 po (7.6 cm) de profondeur; fini gris avec fermeture à clé.
Debouchures - Combinasion 1/2 - 3/4” (Voir Fig. 2) Fils - Pour realiser toutes les connexions utiliser des conducteurs
encuivre.
EH10 - 120 VCA, 50/60 Hz EH40 - 240 VCA, 50/60 Hz
EH10 - 1.0 Watts max. EH40 - 3.0 Watts max.
Model EH10 Unipolaire/Unidirectionnel Model EH40 Bipolaire/Unidirectionnel
AC, 60 Hz
INSTRUCTIONS GÉNÉRALES DE SÉCURITÉ
AVERTISSEMENT: Couper le courant à la source avant d’installler la minuterie et les dispositifs commandés ou avant d’effecteur une intervention quelconque.
1. Se conformer à tous les codes électriques et de sécurité locaux.
2 Si l’interrupteur de coupure du courant n’est pas visible
pendant le travail, le verrouiller en posiiton d’arrêté et y apposer une étiquette en vue de prévenir toute mise en marche accidentelle.
3. Le boîtier de cette minuterie doit être mis à la terre.
4. Ne pas dépasser la capacité maximale de courant de cette minuterie.
5. Toujours remettre en place l’isolateur de borne en plastique avant de mettre la minuterie sous tension.
INSTALLATION
1. Monter la minuterie à l’endroit voulu au moyen des trois trous de montage prévus à cette effet. Monter la minuterie à hauteur des yeux, si possible, ef en laissant suffisamment de place à la gauche du boîtier pour permettre au couvercle de s’ouvrir complètement. (Voir Fig. 2) Il n’est pas nécessaire de retirer le mécanisme de la minuterie de son boîtier pour effectuer le montage étant donné que le trou de montage supérieur est du type à fente. Placer une vis ou un autre dispositif de fixation dans la parol à hauteur des yeux. La tête de la vis ou du dispositif doit être lègérement plus grosse que la partie étroite du trou de montage de façon à ce que la minuterie soit fermement fixée à son emplacement. Les deux autres trous de montage sont accessibles sans qu’il soit nécessaire de démonter le mécanisme de la minuterie. Ils assureront un montage permanent et stable de la minuterie.
2. Si l’on retire le mécanisme de la minuterie de son boîtier, procéder comme indiqué à la Figure 3 en pesant sur l’ergot qui dépasse du haut du boîtier et en tirant sur ce dernier. ATTENTION: NE PAS TOUCHER LES COMPOSANTS DE LA PLAQUETTE DE CIRCUIT. UNE DÉCHARGE D’ÉLECTRICITÉ STATIQUE RISQUE D’ENDOMMAGER LE MICROPORCESSEUR.
3. Replacer le mécanisme dans le boîtier le cas échéant.
4. Soulever le côté gauche de l’isolateur du point d’attache et le faire pivoter vers le haut et vers l’extérieur pour exposer la barrette à bornes.
5. Dénuder les fils d’alimentation et de charge en enlevant 1/2 po (1.2 cm) d’isolant. NE PAS UTILISER DE FILS D’ALUMINUM. (Voir Fig. 4 ou 5.) Insérer les extrémités des fils dans les plaques de borne appropriées et resserrer lels vis fermement. Utiliser des fils AWG #10 à 18. Relier le fil de terre à la borne prévue à cet effet en bas du boîtier.
6. Replacer l’isolatteur en plastique.
7. S’assurer que la pile fonctionne bien. Ceci peut se faire en s’assurant que, l’affichage est bien allumé. Si l’affichage donne des informations brouillées, peser sur l’interrupteur de RAZ (RESET) et le maintenir enfoncé pendant trois à cinq secondes. On notera que la pile est montée en usine et qu’elle se remplace facilement sans avoir, à démonter le mécanisme de la minuterie ni le câblage. Il suffit de peser vers l’intérieur et vers le bas (dans la direction de la flèche) sur le couvercle de la pile (où est inscrit le mot “Battery”). Il est recommandé de remplacer la pile par une pile industrielle de type soin de respectter les indications de polaritté de la pile. Ceci fait partie de l’entretien normal de la minuterie et aucun autre entretien n’est requis.
8. Placer les sélecteurs en position AUTO (automatique) et RUN.
9. Remettre la minuterie sous tension.
10.Peser sur l’interrupteur de RAZ (RESET) pendant trois à cinq secondes. L’affichage indique alors 12:00 A..M. 1. La minuterie est prête à être programmée. Se reporter au tableau ci-bas et entrir les événements aux heures voulues. Assigner chacun des entrées à n’importe quel(s) jour(s) de la semaine où l’on desire que la minuterie mette un dispositif commandé sous tension ou hors tension. On notera que la programmation de deux arrêts consécutifs permet à l’utilisateur de mettre un dispositif sous tension manuellement, après les heures normales de travail par exemple, et de laisser la minuterie le mettre hors tension automatiquement. Ceci permet d’économiser de l’énergie après les heures normales d’occupation des locaux tout en permettant une extinction ou un arrêt automatique du dispositif. On notera de même qu’il est possible de programmer plusieurs arrêts consécutifs, ce qui offre alors plusieurs heures d’extinction ou d’arrêt autotmatique des dispositifs.
AA
standard tous les deux ou trois ans en prenant
- 3 -
Loading...